首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
As a self-regulating heating device, positive temperature coefficient ceramic heater was employed for hot embossing and thermal bonding of poly(methyl methacrylate) microfluidic chip because it supplied constant-temperature heating without electrical control circuits. To emboss a channel plate, a piece of poly(methyl methacrylate) plate was sandwiched between a template and a microscopic glass slide on a positive temperature coefficient ceramic heater. All the assembled components were pressed between two elastic press heads of a spring-driven press while a voltage was applied to the heater for 10 min. Subsequently, the embossed poly(methyl methacrylate) plate bearing negative relief of channel networks was bonded with a piece of poly(methyl methacrylate) cover sheet to obtain a complete microchip using a positive temperature coefficient ceramic heater and a spring-driven press. High quality microfluidic chips fabricated by using the novel embossing/bonding device were successfully applied in the electrophoretic separation of three cations. Positive temperature coefficient ceramic heater indicates great promise for the low-cost production of poly(methyl methacrylate) microchips and should find wide applications in the fabrication of other thermoplastic polymer microfluidic devices.  相似文献   

2.
A water-soluble phospholipid polymer having an active ester group in the side chain, poly[2-methacryloyloxyethyl phosphorylcholine (MPC)-co-n-butyl methacrylate (BMA)-co-p-nitrophenyloxycarbonyl polyethyleneglycol methacrylate (MEONP)(PMBN), was used for the immobilization of an enzyme on a plastic microchip. The MPC polymers with BMA units were adsorbed onto the poly(methyl methacrylate)(PMMA) microchip, and the active ester group in the MEONP unit reacted with the amino groups of the proteolytic enzyme, trypsin. Trypsin was immobilized on the sample reservoir, and catalyzed the hydrolysis of the fluorescently labeled ArgOEt to Arg. The consequent separation of product from the substrate, and their detection, were integrated on the microchip and this meant that all procedures from the enzymatic activity to product detection were completed in less than three minutes.  相似文献   

3.
Plastic microchips are very promising analytical devices for the high-speed analysis of biological compounds. However, due to its hydrophobicity, their surface strongly interacts with nonpolar analytes or species containing hydrophobic domains, resulting in a significant uncontrolled adsorption on the channel walls. This paper describes the migration of fluorescence-labeled amino acids and proteins using the poly(methyl methacrylate) microchip. A cationic starch derivative significantly decreases the adsorption of analytes on the channel walls. The migration time of the analytes was related to their molecular weight and net charge or pI of the analytes. FITC-BSA migrated within 2 min, and the theoretical plate number of the peak reached 480,000 plates/m. Furthermore, proteins with a wide range of pI values and molecular weights migrated within 1 min using the microchip.  相似文献   

4.
Wall coating for capillary electrophoresis on microchips   总被引:2,自引:0,他引:2  
Dolník V 《Electrophoresis》2004,25(21-22):3589-3601
This review article with 116 references describes recent developments in the preparation of wall coatings for capillary electrophoresis (CE) on a microchip. It deals with both dynamic and permanent coatings and concentrates on the most frequently used microchip materials including glass, poly(methyl methacrylate), poly(dimethyl siloxane), polycarbonate, and poly(ethylene terephthalate glycol). Characterization of the channel surface by measuring electroosmotic mobility and water contact angle of the surface is included as well. The utility of the microchips with coated channels is demonstrated by examples of CE separations on these chips.  相似文献   

5.
Chen G  Li J  Qu S  Chen D  Yang P 《Journal of chromatography. A》2005,1094(1-2):138-147
A novel method for bonding poly(methyl methacrylate) (PMMA) electrophoresis microchips at the temperature below the glass transition temperature of PMMA based on in situ polymerization has been demonstrated. Methyl methacrylate (MMA) containing initiators was allowed to prepolymerize in an 85 degrees C water bath for 8 min and 15 min to produce a bonding solution and a dense molding solution, respectively. The channel plate of the PMMA microchip was fabricated by the UV-initiated polymerization of the molding solution between a nickel template and a PMMA plate at room temperature. Prior to bonding, the blank cover was coated with a thin layer of the bonding solution and was bonded to the channel plate at 95 degrees C for 20 min under the pressure of binder clips. The attractive performance of the PMMA chips bonded by the new approach has been demonstrated by separating and detecting dopamine, catechol, three cations, and three organic acids in connection with end-column amperometric detection and contactless conductivity detection.  相似文献   

6.
塑料芯片毛细管电泳电化学检测系统及其性能评价   总被引:2,自引:0,他引:2  
近年来,高分子芯片毛细管电泳技术发展迅速,以聚甲基丙烯酸甲酯(PMMA)为代表的塑料电泳芯片由于其低廉的制作成本与良好的电渗性能,已经成为芯片电泳技术发展的一个重要方向,电化学检测具有灵敏度高、选择性好和易于微型化等优点,因此在塑料芯片电泳领域中具有较好的应用前景。  相似文献   

7.
A novel fiberglass-packed channel in a microchip has been fabricated for flow injection analysis (FIA) based on the in situ polymerization of methyl methacrylate (MMA). MMA prepolymer molding solution containing an ultraviolet initiator was sandwiched between a poly(methyl methacrylate) (PMMA) cover plate and a PMMA base plate bearing a glycerol-permeated fiberglass bundle and exposed to UV light. During the UV-initiated polymerization, the fiberglass bundle was embedded in the PMMA substrate to form a fiberglass-packed microchannel. When the glycerol in the fiberglass bundle was flushed away with water, the obtained porous fiberglass-packed microchannel could serve as an electroosmotic pump and a FIA channel. Scanning electron micrographs offer insights into the fiber-based microchip. The analytical performance of the FIA system has been demonstrated by detecting catechol in connection with end-column amperometric detection. The fiber- based microchips can be fabricated by the new approach without the need for complicated and expensive lithography-based microfabrication techniques, indicating great promise for the low-cost production of microchips, and should find a wide range of applications.  相似文献   

8.
In this work, a piece of glass fiber was inserted into the channel of a poly(methyl methacrylate) (PMMA) electrophoresis microchip to enhance the electroosmotic flow (EOF) and the separation efficiency. The EOF value of the glass fiber-containing microchannel at pH 8.2 was determined to be 4.17 x 10(-4)cm2 V(-1)s(-1). The performance of the new microchip was demonstrated by its ability to separate and detect three purines coupled with end-column amperometric detection. In addition, a piece of trypsin-immobilized glass fiber was inserted into the channel of a PMMA microchip to fabricate a core-changeable microfluidic bioreactor that can be regenerated by changing the fiber. The in-channel fiber bioreactor has been coupled with matrix-assisted laser desorption ionization time-of-flight mass spectrometry for the digestion and peptide mapping of bovine serum albumin and myoglobin.  相似文献   

9.
Wang J  Zhang Y  Okamoto Y  Kaji N  Tokeshi M  Baba Y 《The Analyst》2011,136(6):1142-1147
Online automatic transient isotachophoresis concentration of DNA-aptamer and its thrombin complex by using one kind of pseudo-terminating electrolyte buffer in a cross-channel poly(methyl methacrylate) microchip is reported. Sample injection, transient concentration and separation were done continuously and controlled by a sequential voltage switching program, time-consuming steps and complicated chip design were not required. Peak resolution between DNA-aptamer and its thrombin complex was influenced by this novel pseudo-terminating electrolyte buffer, which was prepared by the addition of chemical component with slow mobility into the same buffer as leading electrolyte buffer. 1100-fold signal enhancement of thrombin complex was achieved by this transient isotachophoresis on a standard cross-form microchip. The concentration effect or standing time of transient isotachophoresis was proved to be influenced by the concentration of leading electrolyte ion and the concentration of pseudo-terminating electrolyte buffer ion (glycine). The transient concentration was followed by on-chip nondenaturing gel electrophoresis in methylcellulose solution for the size-based separation. The detection limit, taken as the lowest thrombin concentration at threefold S/N, was determined to be 0.5 amol in mass by this method.  相似文献   

10.
A novel method based on in-situ surface polymerization of methyl methacrylate (MMA) has been developed for rapid fabrication of poly(methyl methacrylate) (PMMA) electrophoresis microchips with sharp inlet tips. Prepolymerized MMA containing an ultraviolet (UV) initiator was directly sandwiched between a nickel template and a PMMA plate. The image of the relief on the nickel template was precisely replicated in the synthesized PMMA layer on the surface of the commercially available PMMA plate during UV-initiated polymerization at room temperature. The chips were subsequently assembled by thermal bonding of channel plates and cover sheets. The sample was directly introduced into the separation channel through a sharp inlet tip, which was placed in the sample vial, without use of an injection cross. The attractive performance of the novel PMMA microchips has been demonstrated by using contactless conductivity detection for determination of several inorganic ions. Such rapid and simple sample introduction leads to highly reproducible signals with relative standard deviations of less than 5% for peak responses. These new approaches significantly simplify the process of fabricating PMMA devices and show great promise for high-speed microchip analysis.   相似文献   

11.
A sol-gel method was employed to fabricate a poly(methyl methacrylate) (PMMA) electrophoresis microchip that contains a hydrophilic channel wall. To fabricate such a device, tetraethoxysilane (TEOS) was injected into the PMMA channel and was allowed to diffuse into the surface layer for 24 h. After removing the excess TEOS, the channel was filled with an acidic solution for 3 h. Subsequently, the channel was flushed with water and was pretreated in an oven to obtain a sol-gel-modified PMMA microchip. The water contact angle for the sol-gel-modified PMMA was approximately 27.4 degrees compared with approximately 66.3 degrees for the pure PMMA. In addition, the electro-osmotic flow increased from 2.13x10(-4) cm2 V(-1) s(-1) for the native-PMMA channel to 4.86x10(-4) cm2 V(-1) s(-1) for the modified one. The analytical performance of the sol-gel-modified PMMA microchip was demonstrated for the electrophoretic separation of several purines, coupled with amperometric detection. The separation efficiency of uric acid increased to 74,882.3 m(-1) compared with 14,730.5 m(-1) for native-PMMA microchips. The result of this simple modification is a significant improvement in the performance of PMMA for microchip electrophoresis and microfluidic applications.  相似文献   

12.
Yang W  Sun X  Pan T  Woolley AT 《Electrophoresis》2008,29(16):3429-3435
Developments in biology are increasing demands for rapid, inexpensive, and sensitive biomolecular analysis. In this study, polymer microdevices with monolithic columns and electrophoretic channels were used for biological separations. Glycidyl methacrylate-co-ethylene dimethacrylate monolithic columns were formed within poly(methyl methacrylate) microchannels by in situ photopolymerization. Flow experiments in these columns demonstrated retention and then elution of amino acids under conditions optimized for sample preconcentration. To enhance analyte selectivity, antibodies were immobilized on monoliths, and subsequent lysozyme treatment blocked nonspecific adsorption. The enrichment capability and selectivity of these affinity monoliths were evaluated by purifying fluorescently tagged amino acids from a mixture containing green fluorescent protein (GFP). Twenty-fold enrichment and 91% recovery were achieved for the labeled amino acids, with a >25 000-fold reduction in GFP concentration, as indicated by microchip electrophoresis analysis. These devices should provide a simple, inexpensive, and effective platform for trace analysis in complex biological samples.  相似文献   

13.
A dynamic coating using methylcellulose (MC) and a nonionic detergent (polysorbate 20) was developed, which controlled protein adsorption onto the surface of microchannels on a microchip made of poly(methyl methacrylate) (PMMA). Optimum concentration of polysorbate 20 in combination with the range of MC concentrations controlled the protein adsorption onto the microchannel surface, and increased the solubility of the protein samples while facilitating the injection of high concentrations of MC solutions into the microchannels. Higher concentrations of nonionic detergent increased the EOF mobility as opposed to the electrophoretic mobility and caused the electrophoresis to fail. Nondenaturing microchip electrophoresis of protein samples with molecular masses ranging from 20 to 100 kDa were completed in 100 s. Also, successful separation of a BSA sample and its complex with anti-BSA mAb ( 220 kDa) was achieved on a PMMA microchip. The separation exhibited high reproducibility in both migration time (RSD = 1%) and peak area (RSD = 10-15%).  相似文献   

14.
Microchip electrophoresis (MCE), a first-generation micrototal analysis system, has emerged during the miniaturization phase of food analysis. Based on the micellar electrokinetic chromatography mode, a simple and fast MCE method with light emitting diode-induced fluorescence detection was developed for quantitative analysis of amino acids in three different kinds of functional foods, viz. sports beverages, jelly-form beverages, and tablet-form functional foods. In contrast to the glass microchip, we improved the separation of amino acids on a poly(methyl methacrylate) (PMMA) chip by addition of cationic starch derivatives. 4-fluoro-7-nitro-2,1,3-benzoxadiazole, which has a short labeling time for amino acids, was used as the fluorescently labeled dye. This MCE method takes less than 10 min of total analysis time including sample preparation and analysis of amino acids in functional foods on a PMMA chip. The results show that this approach has the potential to be a fast and simple method for amino acid analysis in functional foods.  相似文献   

15.
Weng X  Bi H  Liu B  Kong J 《Electrophoresis》2006,27(15):3129-3135
A novel method of chiral separation based on protein-stationary phase immobilized in a poly(methyl methacrylate) microfluidic chip was developed. BSA conjugated with the shortened carboxylic single-walled carbon nanotubes (SWNTs) was employed as the chiral selector. Successful separation of tryptophan enantiomers was achieved in less than 70 s with a resolution factor of 1.35 utilizing a separation length of 32 mm. This is the first example of chiral separation based on SWNTs-BSA conjugates as stationary phase immobilized in microchip channel. The stability of the stationary phase in the channel was examined by microchip electrophoresis with laser-induced fluorescence detection. Factors that influenced the chiral separation resolution were examined. Under the optimized conditions, the proposed modified chip revealed adequate repeatability concerning run-to-run. These results show that the use of SWNTs-BSA conjugates within microfluidic channels hold great promise for a variety of analytical schemes.  相似文献   

16.
Thrombin generation in blood serves as an important marker for various hemostasis-related diseases and conditions. Analytical techniques currently utilized for determining the thrombin potential of patients rely primarily on the enzymatic activity of thrombin. Microfluidic-based ACE using fluorescently labeled aptamers as affinity probes could provide a simple and efficient technique for the real-time analysis of thrombin levels in plasma. In this study, aptamers were used for the analysis of thrombin by affinity microchip CGE. The CGE used a poly(methyl methacrylate) (PMMA) microfluidic device for the sorting of the affinity complexes with a linear polyacrylamide (LPA) serving as the sieving matrix. Due to the fact that the assay was run under nonequilibrium electrophoresis conditions, the presence of the sieving gel was found to stabilize the affinity complex, providing improved electrophoretic performance compared to free-solution electrophoresis. Two fluorescently labeled aptamer affinity probes, HD1 and HD22, which bind to exosites I and II, respectively, of thrombin were investigated. With an electric field strength of 300 V/cm, two well-resolved peaks corresponding to free aptamer and the thrombin-aptamer complex were obtained in less than 1 min of separation time with a run-to-run and chip-to-chip reproducibility (RSD) of migration times <10% using both aptamers. HD22 affinity assays of thrombin produced baseline-resolved peaks with favorable efficiency due to its higher binding affinity, whereas HD1 assays showed poorer resolution of the free aptamer and complex peaks. HD22 was used in determining the level of thrombin in human plasma. Assays were performed directly on plasma that was diluted to 10% v/v. Thrombin was successfully analyzed by microchip CGE at a concentration level of 543.5 nM for the human plasma sample.  相似文献   

17.
Liu D  Zhou X  Zhong R  Ye N  Chang G  Xiong W  Mei X  Lin B 《Talanta》2006,68(3):616-622
Microchip electrophoresis is a promising technique for analysis of bio-molecules. It has the advantages of fast analysis, high sensitivity, high resolution and low-cost of samples. Plastic chip has the potential of mass production for clinical use for its advantages in biocompatibility and low cost. In this work, the method for fabrication of poly(methyl methacrylate) (PMMA) chip was described, and conditions for DNA separation were investigated with the chip. The PMMA microchip was used for detection of multiplex PCR products of 18 and 36 cases with SARS and hepatitis B virus infection under optimized separation conditions. Microchip electrophoresis showed higher sensitivity, higher resolution and less time consumption when compared with gel electrophoresis. The microchip electrophoresis with PMMA chip provided a rapid, sensitive and reliable method for analysis of multiplex PCR products.  相似文献   

18.
We developed a novel channel wall coating on a poly(methyl methacrylate) (PMMA) microchip using methylcellulose (MC) as a coating reagent to suppress electroosmotic flow (EOF) following the strong analytes adsorption via hydrophobic interaction with channel walls of PMMA. Our coating was obtained by first rinsing channel walls with MC-containing aqueous solution followed by evaporation. The coating made the hydrophilic channel wall lowering EOF by two orders of magnitude (1.2 x 10(-5)cm(2)V(-1)s(-1)) as well as reducing the hydrophobic adsorption. On the coated channel walls, we successfully separated sodium dodecyl sulfate-protein complexes with high reproducibility and efficiency using dextran as a lower viscosity protein separation medium.  相似文献   

19.
The precise design and operational control of the separation process of liquid matrices is key to the performance of on-chip liquid analysis. Present research attempts from the engineering point of view to investigate of the process occurring in the microfluidic channels for chip design with the best separation efficiency. An one-dimensional model of electrokinetic sample motion was developed to simulate the separation process of sample containing amino acids (tryptophan, tyrosine, proline, methionine) that migrate in a buffer solution through a straight separation channel made of poly(methyl methacrylate) within a microfluidic chip under different conditions. On the basis of the simulations by the finite-difference method the effects of the channel size, the chip material, the applied voltage difference and the test solution pH on separation rate are discussed. It was found that for the channel length of 2 cm the resolution of peaks is optimal and the fastest time of amino acids separation is 4 s.  相似文献   

20.
Liu J  Wang J  Chen Z  Yu Y  Yang X  Zhang X  Xu Z  Liu C 《Lab on a chip》2011,11(5):969-973
A three-layer poly (methyl methacrylate) (PMMA) electrophoresis microchip integrated with Pt microelectrodes for contactless conductivity detection is presented. A 50 μm-thick PMMA film is used as the insulating layer and placed between the channel plate (containing the microchannel) and the electrode plate (containing the microelectrode). The three-layer structure facilitates the achievement of a thin insulating layer, obviates the difficulty of integrating microelectrodes on a thin film, and does not compromise the integration of microchips. To overcome the thermal and chemical incompatibilities of polymers and photolithographic techniques, a modified lift-off process was developed to integrate Pt microelectrodes onto the PMMA substrate. A novel two-step bonding method was created to assemble the complete PMMA microchip. A low limit of detection of 1.25 μg ml(-1) for Na(+) and high separation efficiency of 77,000 and 48,000 plates/m for Na(+) and K(+) were obtained when operating the detector at a low excitation frequency of 60 kHz.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号