首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
By electrospray ionization (ESI) mass spectrometry, micelle solutions of sodium cholate were investigated in detail in the presence and absence of ethanol. The average aggregation number could be evaluated from the spectra acquired under conditions where soft collisions adequate to measure the micelle solution were induced, and the value agreed well with that obtained previously by other methods. From the dependence on ethanol content, it was also found that the average aggregation number in aqueous solution without organic solvent could be reliably estimated. The ESI method proved to be a useful tool for determining the micelle mass in the original aqueous phase.  相似文献   

2.
Mass spectrometry (MS) is an effective analytical tool for high-throughput screening (HTS) in the drug discovery field. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) MS is a high-throughput platform that has achieved analysis times of sub-seconds-per-sample. Due to the high-throughput analysis speed, methods are needed to increase the analyte signal while decreasing the variability in IR-MALDESI-MS analyses to improve data quality and reduce false-positive hits. The Z-factor is used as a statistic of assay quality that can be improved by reducing the variation of target ion abundances or increasing signal. Herein we report optimal solvent compositions for increasing measured analyte abundances with direct analysis by IR-MALDESI-MS. We also evaluate normalization strategies, such as adding a normalization standard that is similar or dissimilar in structure to the model target drug, to reduce the variability of measured analyte abundances with direct analyses by IR-MALDESI-MS in both positive and negative ionization modes.  相似文献   

3.
On-line electrochemistry/electrospray ionization mass spectrometry (EC/ESI-MS) was developed using a microflow electrolytic cell. This technique was applied to electrochemical oxidation of caffeic acid (CAF) which is known to be a highly antioxidative agent. Effects of electrolytic potentials on ion intensities of product ions and on electrolytic currents were examined at different pHs. Dimer products were detected at electrolytic potentials of E = 0.7 V (vs. Ag/AgCl) and trimer products at 1.0 V at pH 9. Dimer products were distinguished from hydrogen-bonded complexes by MS/MS experiments. Hydrogen/deuterium exchange experiments determined the number of hydroxyl and carboxyl groups in the Dimers formed by electrolysis. The mechanism of oxidative polymerization of CAF is discussed with speculation as to the structure of the dimer product.  相似文献   

4.
Summary Pyrolysis-field ionization mass spectrometry (Py-FIMS) was used for the first time to directly characterize Chinese coals and their extracts. The summed mass spectra (about 30 magnetic scans) of four coal samples and the dimethylformamide extracts of two very different coals were registered between 50° and 750°C using linear heating in high vacuum (10–3 Pa) and approximately 6 min temperature rise time. Utilizing temperature-programmed pyrolysis and FI as soft ionization mode, the spectra displayed almost exclusively molecular ions of the evolved products. The thermograms, i.e. the intensities of the total ion current and selected ions were plotted versus the scan number, heating time and temperature. In general, two maxima in these thermograms were observed, which were different for the coals and reflected their carbon/hydrogen content. Comparing the mass spectra of the low temperature part (first maximum) with summed spectra of the extracts shows an interesting similarity. In contrast, the high temperature part (second maximum) indicates the products of thermo-degradation. The applied method is a fast and convenient tool for the characterization of evolved volatiles and thermal degradation products of coals and coal extracts.
Kennzeichnung von Kohlen mit direkter Pyrolyse und Feldionisations-Massenspektrometrie
  相似文献   

5.
This work describes the synchronized dual-polarity (DP) electrospray ionization (ESI) method and demonstrates the first DP ESI mass spectra obtained using two mass spectrometers. Stable double Taylor cones were produced by applying two counter electric voltages with opposite polarities to one electrosprayer. The development of double Taylor cones required higher extraction voltages than conventional ESI, but DP ESI worked effectively at liquid flow rate range three times wider than conventional ESI. Using pure methanol, the emission currents of the two cones were neutralized and no current was drawn from the sprayer. Synchronized DP mass spectra were obtained using electrospray calibrants dissolved in methanol solution of low water content. For bovine insulin with conventional electrospray solution, the gas-assisted electrospray delivered satisfactory sensitivity and stability for routine mass analyses.  相似文献   

6.
Rapid screening of clenbuterol in urine was performed by combining desorption electrospray ionization (DESI) and tandem mass spectrometry (MS/MS). Optimization experiments were carried out including the selection of substrates, spray solutions, nebulizing gas pressures, high-voltage power supplies and flow rates of spray solution. The limit of detection (LOD), defined as the lowest quantity that can be detected, was 5.0 pg for the pure compound. Using DESI coupled with solid-phase extraction (SPE), the linear response range was from 10 to 400 ng/mL (R(2) = 0.993) and the concentration LOD for urine sample was 2.0 ng/mL. The analysis for one spiked urine sample was achieved within 4 min. In addition to the fast analysis speed, MS/MS provided structural information for the confirmation of clenbuterol. Urine samples from different people were investigated and the recoveries were within 100 +/- 20%. The developed method can potentially be used for screening of clenbuterol in doping control.  相似文献   

7.
8.
Nanoscale capillary liquid chromatography (nCLC) and capillary zone electrophoresis (CZE) have been combined with quadrupole mass spectrometry via an electrospray ionization (ESI) interface. These methodologies have been applied to the separation and determination of a variety of sulfonamides. CZE/ESI/MS is the more rapid and sensitive technique, but nCLC/ESI/MS shows promise for the analysis of dilute samples. Ultimately, the two techniques provide complementary methods of analysis. The detection limits of these techniques in the full-scan mode are in the low picomole range. Dissociation of the sulfonamides can be induced by increasing the skimmer voltage. This provides a limited means of discriminating between compounds of identical molecular weight but, more important, provides fragments that could be used to confirm the presence of analyte within a sample.  相似文献   

9.
10.
In vivo skin analysis by Desorption Electrospray Ionization was characterized on healthy human volunteers by directing pneumatically assisted electrospray directly onto their fingertips. In order to eliminate the risk of electric shock, a high ohmic resistor was built into the system. Positive ion DESI-MS analysis yields low intensity spectra, while negative ion spectra feature a number of various biogenic carboxylic acids. Compounds of external origin and excreted molecules were found to have different analysis kinetics, with the exception of highly hydrophobic species. The difference was demonstrated in the case of nicotine and cotinine. Pharmacokinetic studies were performed using a rat animal model. The kinetics of the anesthetic ketamine was followed by DESI, and results were in agreement with off-line HPLC-MS blood analysis. Using a similar approach for N,N'-dimethylthiourea (DMTU), a novel method was developed for the real-time quantification of oxidative stress. DMTU was administered to the animals, and the ratio of the molecule and its oxidized form was monitored from the skin surface. The ratio was found to be highly sensitive to experimentally induced diabetes mellitus type I and angiotensin-induced chronic oxidative stress. It was concluded that the method has a number of potential applications in the fields of forensics, pharmacology and clinical chemistry.  相似文献   

11.
A newly developed high-throughput desorption electrospray ionization (DESI) source was characterized in terms of its performance in quantitative analysis. A 96-sample array, containing pharmaceuticals in various matrices, was analyzed in a single run with a total analysis time of 3 min. These solution-phase samples were examined from a hydrophobic PTFE ink printed on glass. The quantitative accuracy, precision, and limit of detection (LOD) were characterized. Chemical background-free samples of propranolol (PRN) with PRN-d7 as internal standard (IS) and carbamazepine (CBZ) with CBZ-d10 as IS were examined. So were two other sample sets consisting of PRN/PRN-d7 at varying concentration in a biological milieu of 10% urine or porcine brain total lipid extract, total lipid concentration 250 ng/μL. The background-free samples, examined in a total analysis time of 1. 5 s/sample, showed good quantitative accuracy and precision, with a relative error (RE) and relative standard deviation (RSD) generally less than 3% and 5%, respectively. The samples in urine and the lipid extract required a longer analysis time (2. 5 s/sample) and showed RSD values of around 10% for the samples in urine and 4% for the lipid extract samples and RE values of less than 3% for both sets. The LOD for PRN and CBZ when analyzed without chemical background was 10 and 30 fmol, respectively. The LOD of PRN increased to 400 fmol analyzed in 10% urine, and 200 fmol when analyzed in the brain lipid extract.  相似文献   

12.
Non-covalent interactions between met- and leu-enkephalins and their antisense peptides were studied by electrospray ionization mass spectrometry. Mixtures of sense and antisense peptides gave both the corresponding homodimers and heterodimers. The relative abundance ratios of the heterodimer to that of the homodimer of the sense peptide and the relative stability constants of the heterodimers were compared with the corresponding values from mixtures of the sense peptides and a control peptide. The results show that there is a preferential interaction between the sense and antisense peptides compared with that between the sense and control peptides.  相似文献   

13.
The known thermal and hydrolytic stability of bismuth-sulfur bonds indicates that biological targets for bismuth likely involve thiol or thiolate functionalities, such as in L-cysteine. Complexes of bismuth with cysteine or other thiol-carboxylic acid ligands have been isolated and characterized providing a preliminary view of the potential participation of these functional groups in the biochemical mechanisms involving bismuth. A broader assessment of bismuth-thiolate interactions has been possible using electrospray ionization mass spectrometry (ESI-MS). A wide range of complexes has been observed containing mercaptosuccinic acid, 2-mercaptopropionic acid, 3-mercaptopropionic acid, and/or 2-amino-3-mercaptopropionic acid (cysteine). The identification of various multibismuth multiligand cluster ions defines new chemistry for bismuth.  相似文献   

14.
Sartans and related analogues with 5‐oxo‐l, 2, 4‐oxadiazole ring and tetrazole ring are investigated in detail using collision‐induced dissociation (CID) method in positive ion mode by electrospray ionization tandem mass spectrometry (ESI‐MSn). It is found that the protonated sartans and related analogues tend to form the N‐substituted‐3‐substituted phenanthridin‐6‐amine ion which has a large conjugative structure. The possible fragmentation pathways were proposed for the first time, and the key structure of product ions was confirmed by high resolution tandem mass spectrometry and theoretical calculation. It is very helpful for understanding the intriguing roles of sartans analogues in fragmentation reactions and enriching the knowledge of the gas‐phase chemistry of the oxadiazole and tetrazole ring. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

15.
16.
Rezenom YH  Dong J  Murray KK 《The Analyst》2008,133(2):226-232
We have used an infrared laser for desorption of material and ionization by interaction with electrosprayed solvent. Infrared laser-assisted desorption electrospray ionization (IR LADESI) mass spectrometry was used for the direct analysis of water-containing samples under ambient conditions. An ion trap mass spectrometer was modified to include a pulsed Er:YAG laser at 2.94 microm wavelength coupled into a germanium oxide optical fiber for desorption at atmospheric pressure and a nanoelectrospray source for ionization. Analytes in aqueous solution were placed on a stainless steel target and irradiated with the pulsed IR laser. Material desorbed and ablated from the target was ionized by a continuous stream of charged droplets from the electrosprayed solvent. Peptide and protein samples analyzed using this method yield mass spectra similar to those obtained by conventional electrospray. Blood and urine were analyzed without sample pretreatment to demonstrate the capability of IR LADESI for direct analysis of biological fluids. Pharmaceutical products were also directly analyzed. Finally, the role of water as a matrix in the IR LADESI process is discussed.  相似文献   

17.
Glycerol is widely used as protein stabilizer, in both local and commercial preparations, so it has become necessary to develop methods for mass spectrometric analysis of protein preparations in the presence of glycerol. However, this stabilizing agent may cause signal suppression when present in high concentrations, and is also known to induce protein supercharging even at low concentrations. This work reports the use of electrospray ionization (ESI) mass spectrometry to characterize glycerol-mediated protein oligomerization. This phenomenon seems to involve the formation of strong non-covalent interactions between protein and glycerol involving close contact between the monomers, leading to formation of protein oligomers adducted with glycerol molecules under the characteristic analytical conditions of the ESI interface. At high orders of oligomerization a lower number of glycerol molecules is required to maintain the high oligomeric states than for the dimers and trimers, and it is possible that for the higher oligomers the monomers become so close to one another that non-covalent bonds between the side chains of the amino acid residues in the proteins may be established.  相似文献   

18.
Editorial Comment Last month we presented, as a Special Feature, a set of five articles that constituted a Commentary on the fundamentals and mechanism of electrospray ionization (ESI). These articles produced some lively discussion among the authors on the role of electrochemistry in ESI. Six authors participated in a detailed exchange of views on this topic, the final results of which constitute this month's Special Feature. We particularly hope that younger scientists will find value in this month's Special Feature, not only for the science that it teaches but also what it reveals about the processes by which scientific conclusions are drawn. To a degree, the contributions part the curtains on these processes and show science in action. We sincerely thank the contributors to this discussion. The give and take of intellectual debate is not always easy, and to a remarkable extent this set of authors has maintained good humor and friendships, even when disagreeing strongly on substance. Graham Cooks and Richard Caprioli Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

19.
20.
A multiple sprayer electrospray ion source for high-throughput analysis is described. The ion source is comprised of multiple electrospray capillaries, each with an ion lens located near the tip. The electric potentials applied to the ion lenses are used to control the sprayers. The use of ion lenses eliminates the need for mechanical blocking devices to selectively enable or disable the sprayers, and results in a less expensive and more reliable set-up. Sprayers can be enabled or disabled within approximately 50-250 ms when the lens potentials are controlled manually. For simultaneous operation of multiple electrospray capillaries, it is advantageous to orient the capillaries so that the spray from each passes directly in front of the entrance aperture of the mass spectrometer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号