首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Du M  Yang T  Ma S  Zhao C  Jiao K 《Analytica chimica acta》2011,(2):9921-174
Electrochemical activities of typically electrochemical targets at three kinds of modified carbon electrodes, i.e. carbon ionic liquid electrode (CILE), graphene/carbon paste electrode (CPE), and ionic liquid-functionalized graphene (IL-graphene)/CPE, were compared in detail. The redox processes of the probes at IL-graphene/CPE were faster than those at CILE and graphene/CPE from cyclic voltammetry. An electrochemical method for the simultaneous determination of guanine and adenine was described with detection limits of 6.5 × 10−8 mol L−1 (guanine) and 3.2 × 10−8 mol L−1 (adenine). Single A → G mutation of sequence-specific DNA could be discriminated by the IL-graphene/CPE.  相似文献   

2.
《Analytical letters》2012,45(13):2266-2280
A novel electrochemical immunosensor was developed for the determination of prostate-specific antigen based on immobilization of appropriate antibodies on gold nanoparticles and a poly-(2,6-pyridinediamine) modified electrode. The nanocomposite of ferrocene monocarboxylic acid hybridized graphene oxide was prepared by a π-π stacking interaction and was used as the electrochemical probe. A sandwich-type complex immunoassay was applied with polyclonal prostate-specific antigen antibodies labeled with the nanocomposite of ferrocene monocarboxylic acid hybridized graphene oxide. In order to improve the sensitivity, a potentiostatic method was used to reduce graphene oxide. Cyclic voltammetry and differential pulse voltammetry were employed to characterize the assembly process and the performance of the immunosensor. Under optimal conditions, the peak current of the immunosensor increased with concentration, showing a linear relationship between the peak current and the logarithm of the prostate-specific antigen concentrations in a wide range of 2.0 pg mL?1 to 10.0 ng mL?1 with a low detection limit of 0.5 pg mL?1. The immunosensor was used for the determination of prostate-specific antigen in serum.  相似文献   

3.
This study describes a simple and label-free electrochemical impedance spectroscopic (EIS) method for sequence-specific detection of DNA by using single-walled carbon nanotubes (SWNTs) as the support for probe DNA. SWNTs are confined onto gold electrodes with mixed self-assembly monolayers of thioethanol and cysteamine. Single-stranded DNA (ssDNA) probe is anchored onto the SWNT support through covalent binding between carboxyl groups at the nanotubes and amino groups at 5′ ends of ssDNA. Hybridization of target DNA with the anchored probe DNA greatly increases the interfacial electron-transfer resistance (Ret) at the double-stranded DNA (dsDNA)-modified electrodes for the redox couple of Fe(CN)63−/4−, which could be used for label-free and sequence-specific DNA detection. EIS results demonstrate that the utilization of SWNTs as the support for probe DNA substantially increases the surface loading of probe DNA onto electrode surface and thus remarkably lowers the detection limit for target DNA. Under the conditions employed here, Ret is linear with the concentration of target DNA within a concentration range from 1 to 10 pM with a detection limit down to 0.8 pM (S/N = 3). This study may offer a novel and label-free electrochemical approach to sensitive sequence-specific DNA detection.  相似文献   

4.
The surface of graphene oxide was modified by bis(3-aminopropyl)-terminated polyethylene glycol to produce a composite graphene–polyethylene glycol. The graphene oxide/polyethylene glycol maximum absorption peak in the ultraviolet–visible spectrum was redshifted, and transmission electron microscope images showed that graphene oxide was cleaved into small nanosheets to form graphene oxide/polyethylene glycol. The dispersibility of graphene oxide/polyethylene glycol in physiological solution was higher than for graphene oxide. The optimum composite of graphene oxide/polyethylene glycol was used as a quencher in a fluorescence resonance energy transfer aptasensor for the determination of lysozyme detection. The results showed that graphene oxide/polyethylene glycol rapidly and efficiently quenched the fluorescence of the dye-labeled aptamer. The fluorescence was recovered by adding lysozyme to the system. The aptamer fluorescence intensity exhibited a strong linear dependence on the lysozyme concentration from 50 to 300?nM, and the lysozyme detection limit was approximately 11?nM. This method was used for the determination of lysozyme in egg whites, demonstrating that this approach is a promising alternative for the determination of lysozyme.  相似文献   

5.
Herein, we present the electrochemical co-deposition of Al3+/graphene composites directly from an aqueous mixture containing graphene oxide (GO) and Al3+. The obtained Al3+/graphene composites with good electrochemical activity were regarded as an appropriate immobilization platform for double-stranded DNA (dsDNA). The nontoxic redox probe xanthurenic acid (XA) was successfully applied to recognize single-stranded DNA and dsDNA. We illustrated that the scission of dsDNA caused by GO combining with some metal ions could be detected by monitoring the electrochemical signals of XA.  相似文献   

6.
We report on an aptamer with high affinity against Salmonella typhimurium (S. typhimurium) and selected from an enriched oligonucleotide pool by a whole-cell SELEX process in a method for the fluorimetric determination of S. typhimurium using a graphene oxide platform. In the absence of target, the fluorescence was fairly weak as result of the FAM-labeled aptamer adjacent to graphene oxide. If, however, the fluorophore is released from the graphene oxide due to the formation of the target/aptamer complexes, fluorescence intensity is substantially increased. Under the optimum conditions, the assay displays a linear response to bacteria in the concentration range from 1?×?103 to 1?×?108 CFU·mL?1, with a detection limit of 100 CFU·mL?1. The method is selective in that fluorescence is not much enhanced in case of other bacteria. This aptasensor displays higher sensitivity and selectivity than others and is believed to possess a large potential with respect to the rapid detection of bacteria.
Figure
A useful fluorescence aptasensor based on a graphene oxide platform was constructed for Salmonella typhimurium detection, which has a great potential application in rapid detection of pathogen as it has high sensitivity and selectivity.  相似文献   

7.
In this study, highly hydrophilic and photoluminescent sheets of reduced graphene oxide decorated with carbon dots (C-dots@RGO), methylene blue (MB), and a probe DNA have been used for the detection of DNA. The photoluminescence of C-dots@RGO is quenched by MB, which is restored in the presence of a target DNA. The combination of the C-dots@RGO, MB, and a DNA probe is selective for perfectly matched DNA over mismatched DNA, mainly because relative to single-stranded DNA, double-stranded DNA intercalates more strongly with MB, but interacts more weakly with RGO. In the presence of a target DNA, MB intercalates with the as-formed double-stranded DNA and is released from the surface of C-dots@RGO, leading to “turn-on” photoluminescence. The practicality of this assay has been validated by the determination of tumor suppressor gene BRCA1, with linearity over the concentration range from 25 to 250 nM and a limit of detection (LOD, at a signal-to-noise ratio of 3) of 14.6 nM. The C-dots@RGO probe provides higher specificity towards target DNA than towards common salts, carbohydrates, amino acids, and proteins found in real samples. Having the advantages of simplicity, cost-effectiveness, selectivity, and sensitivity, the DNA-P/C-dots@RGO–MB probe on microwells has been successfully employed for the detection of DNA, suggesting its potential for multiple analyses of DNA targets when various DNA probes are employed.  相似文献   

8.
A nonlabeling electrochemical detection method for analyzing the polymerase-chain-reaction-amplified sequence-specific p16 INK4A gene, in which the basis for the covalent immobilization of deoxyribonucleic acid (DNA) probe is described, has been developed. The self-assembly process was based on the covalent coupling of glutaraldehyde (GA) as an arm molecule onto an amino-functional surface. The p16 INK4A gene was used as the model target for the methylation detection of early cancer diagnosis. An amino-modified DNA probe was successfully assembled on the GA-coupling surface through the formation of Schiff base under potential control. The hybridization of amino-modified DNA probes with the target was investigated by means of electrochemical measurements, including cyclic voltammetry and square wave voltammetry. Furthermore, the functions of GA coupling for sequence-specific detection were compared with those obtained based on mercaptopropionic acid. Hybridization experiments indicated that the covalent coupling of GA was suitable for the immobilization of DNA probe and was sensitive to the electrochemical detection of single-base mismatches of label-free DNA targets in hybridization. Moreover, reported probe-modified surfaces exhibited excellent stability, and the hybridization reactions were found to be completely reversible and highly specific for recognition in subsequent hybridization processes. The strategy provided the potential for taking full advantage of existing modified electrode technologies and was verified in microarray technology, which could be applied as a useful and powerful tool in electrochemical biosensor and microarray technology.  相似文献   

9.
10.
Interfacing DNA oligonucleotides with graphene-based materials, especially graphene oxide, has produced many new sensors and devices. Since graphene oxide is an excellent fluorescence quencher, fluorescently labeled DNAs (probes) are nearly fully quenched upon adsorption. Addition of the complementary DNA results in probe desorption and fluorescence enhancement. Aside from its analytical applications, this system provides a fascinating topic for biointerface science. DNA can be adsorbed by graphene oxide via π–π stacking and hydrogen bonding, while it must overcome electrostatic repulsion at the same time. The mechanism of DNA-induced probe desorption has also been a topic of extensive discussion. In this article, DNA adsorption and desorption reactions and interactions with graphene oxide and related materials (e.g. graphene) are reviewed based on the current understandings. A few representative applications based on these processes are also described briefly.  相似文献   

11.
A simple and sensitive voltammetric sensor for esculetin, based on electrochemically reduced graphene oxide film modified glassy carbon electrode, was reported for the quantitative determination of esculetin in the Chinese traditional herbal drug Viola yedoensis Makino. Electrochemical impedance spectroscopy and scanning electron microscopy were employed to study the characteristic of the graphene oxide film. The electrochemical behavior of esculetin on this sensor was investigated in pH 3.0 phosphate buffer solution by cyclic voltammetry. Significant advantages were achieved by the excellent conductivity and the high surface‐to‐volume ratio of electrochemically reduced graphene oxide. A calibration plot of oxidation peak currents versus esculetin concentrations was linear in the range of 4.0 ξ 10‐8 mol L‐1 to 5.0 ξ 10‐6 mol L‐1 with a detection limit of 2.0 ξ 10‐8 mol L‐1. The practical application of the present sensor was demonstrated by determining the concentration of esculetin in real sample with no interference.  相似文献   

12.
Yan Wang  Ming Yin 《Mikrochimica acta》2009,166(3-4):243-249
Microfluidic chip capillary electrophoresis with laser-induced fluorescence detection is employed for direct determination of trace nitric oxide in human blood using diaminorhodamines as the fluorescence probe. Factors influencing the separation and detection processes were systematically studied. Complete and fast separation of the highly fluorescent triazole formed was achieved within 45 s, and the relative standard deviations values of migration time and peak area were less than 3%. The detection limit of NO was 3.0 nmol.L-1 (at a signal-to-noise ratio of 3) and the liner range was from 1.0?×?10-8?mol.L-1 to 3.0?×?10-6?mol.L-1. The method has been applied to the determination of NO in serum of healthy persons and patients suffering from diseases, with recoveries varying from 92.65 to 98.43%.  相似文献   

13.
In this work, europium-decorated graphene quantum dots (Eu-GQDs) were prepared by treating three-dimensional Eu-decorated graphene (3D Eu-graphene) via a strong acid treatment. Various characterizations revealed that Eu atoms were successfully complexed with the oxygen functional groups on the surface of graphene quantum dots (GQDs) with the atomic ratio of 2.54%. Compared with Eu free GQDs, the introduction of Eu atoms enhanced the electron density and improved the surface chemical activities of Eu-GQDs. Therefore, the obtained Eu-GQDs were used as a novel “off-on” fluorescent probe for the label-free determination of Cu2+ and l-cysteine (L-Cys) with high sensitivity and selectivity. The fluorescence intensity of Eu-GQDs was quenched in the presence of Cu2+ owing to the coordination reaction between Cu2+ and carboxyl groups on the surface of the Eu-GQDs. The fluorescence intensity of Eu-GQDs recovered with the subsequent addition of L-Cys because of the strong affinity of Cu2+ to L-Cys via the Cu–S bond. The experimental results showed that the fluorescence variation of the proposed approach had a good linear relationship in the range of 0.1–10 μM for Cu2+ and 0.5–50 μM for L-Cys with corresponding detection limits of 0.056 μM for Cu2+ and 0.31 μM for L-Cys. The current approach also displayed a special response to Cu2+ and L-Cys over the other co-existing metal ions and amino acids, and the results obtained from buffer-diluted serum samples suggested its applicability in biological samples.  相似文献   

14.
A fluorometric method for quantity analysis of biothiols was developed using a graphene oxide (GO)-based “molecular beacon”-like probe, which consisted of FITC labeled thymine (T)-rich single-stranded DNA (ssDNA), GO and Hg2+ ions. The labeled ssDNA containing T–T mismatches would self-hybridize to duplex in the presence of Hg2+, which can avoid its adsorption on GO and the fluorescence of this GO-based probe was recovered. The fluorescence of the probe quenched after the addition of biothiols such as glutathione (GSH) and cysteine (Cys) owing to thiol groups can selectively competitive ligation of Hg2+ ions with T–T mismatches. In the present work, the GO-based probe was used for the determination of GSH and Cys. Under the optimal conditions, a linear correlation was established between fluorescence intensity ratio I0/I and the concentration of GSH in the range of 2.0 × 10−9–5.0 × 10−7 mol L−1 with a detection limit of 1.0 × 10−9 mol L−1. The linear range for Cys is from 5.0 × 10−9 to 4.5 × 10−7 mol L−1 with a detection limit of 2.0 × 10−9 mol L−1. The proposed method was applied to the determination of GSH in human serum and cell extract samples with satisfactory results.  相似文献   

15.
Chemical sensors relying on graphene-based materials have been widely used for electrochemical determination of metal ions and have demonstrated excellent signal amplification. This study reports an electrochemically reduced graphene oxide (ERGO)/mercury film (HgF) nanocomposite-modified pencil graphite electrode (PGE) prepared through successive electrochemical reduction of graphene oxide (GO) sheets and an in situ plated HgF. The ERGO-PG-HgFE, in combination with dimethylglyoxime (DMG) and square-wave adsorptive cathodic stripping voltammetry (SW-AdCSV), was evaluated for the determination of Ni2+ in tap and natural river water samples. A single-step electrode pre-concentration approach was employed for the in situ Hg-film electroplating, metal-chelate complex formation, and non-electrolytic adsorption at –0.7 V. The current response due to nickel-dimethylglyoxime [Ni(II)-DMG2] complex reduction was studied as a function of experimental paratmeters including the accumulation potential, accumulation time, rotation speed, frequency and amplitude, and carefully optimized for the determination of Ni2+ at low concentration levels (μg?L?1) in pH 9.4 of 0.1 M NH3–NH4Cl buffer. The reduction peak currents were linear with the Ni2+ concentration between 2 and 16?μg?L?1. The limits of detection and quantitation were 0.120?±?0.002?µg?L?1 and 0.401?±?0.007?µg?L?1 respectively, for the determination of Ni2+ at an accumulation time of 120?s. The ERGO-PG-HgFE further demonstrated a highly selective stripping response toward Ni2+ determination compared to Co2+. The electrode was found to be sufficiently sensitive to determine metal ions in water samples at 0.1?µg?L?1, well below the World Health Organization standards.  相似文献   

16.
Graphene/zinc oxide nanocomposite was synthesised via a facile, green and efficient approach consisted of novel liquid phase exfoliation and solvothermal growth for sensing application. Highly pristine graphene was synthesised through mild sonication treatment of graphite in a mixture of ethanol and water at an optimum ratio. The X-ray diffractometry (XRD) affirmed the hydrothermal growth of pure zinc oxide nanoparticles from zinc nitrate hexahydrate precursor. The as-prepared graphene/zinc oxide (G/ZnO) nanocomposite was characterised comprehensively to evaluate its morphology, crystallinity, composition and purity. All results clearly indicate that zinc oxide particles were homogenously distributed on graphene sheets, without any severe aggregation. The electrochemical performance of graphene/zinc oxide nanocomposite-modified screen-printed carbon electrode (SPCE) was evaluated using cyclic voltammetry (CV) and amperometry analysis. The resulting electrode exhibited excellent electrocatalytic activity towards the reduction of hydrogen peroxide (H2O2) in a linear range of 1–15 mM with a correlation coefficient of 0.9977. The sensitivity of the graphene/zinc oxide nanocomposite-modified hydrogen peroxide sensor was 3.2580 μAmM−1 with a limit of detection of 7.4357 μM. An electrochemical DNA sensor platform was then fabricated for the detection of Avian Influenza H5 gene based on graphene/zinc oxide nanocomposite. The results obtained from amperometry study indicate that the graphene/zinc oxide nanocomposite-enhanced electrochemical DNA biosensor is significantly more sensitive (P < 0.05) and efficient than the conventional agarose gel electrophoresis.  相似文献   

17.
We describe the fabrication of a sensitive label-free electrochemical biosensor for the determination of sequence-specific target DNA. It is based on a glassy carbon electrode (GCE) modified with graphene, gold nanoparticles (Au-NPs), and polythionine (pThion). Thionine was firstly electropolymerized on the surface of the GCE that was modified with graphene by cyclic voltammetry. The Au-NPs were subsequently deposited on the surface of the pThion/graphene composite film by adsorption. Scanning electron microscopy and electrochemical methods were used to investigate the assembly process. Differential pulse voltammetry was employed to monitor the hybridization of DNA by measuring the changes in the peak current of pThion. Under optimal conditions, the decline of the peak current is linearly related to the logarithm of the concentration of the target DNA in the range from 0.1 pM to 10 nM, with a detection limit of 35 fM (at an S/N of 3). The biosensor exhibits good selectivity, acceptable stability and reproducibility.
Figure
A label-free DNA biosensor based on Au-NPs/pThion/graphene modified electrode has been fabricated. Differential pulse voltammetry (DPV) was employed to monitor DNA hybridization event by measurement of the peak current changes of pThion.  相似文献   

18.
《Analytical letters》2012,45(14):2350-2360
A sensitive and selective fluorescent aptasensor for adenosine triphosphate (ATP) was fabricated, composed of unbound SYBR Green I, graphene oxide, and a label-free detection probe. When ATP and complementary DNA of a signal probe were introduced, π-stacking interactions repelled the probe from the graphene oxide and formed a DNA-SYBR Green I duplex structure, triggering an increase in the fluorescence. ATP was determined over a linear range of 10 to 700 nM with a detection limit of 1 nM. The method displayed good selectivity, and is currently the most sensitive ATP fluorescence method. Furthermore, prominent fluorescence signals were also obtained in cellular assays. Consequently, the biosensor may have significant applications in protein, pathogenic microorganisms, and small molecule detection.  相似文献   

19.
We report on the development of a sensitive and selective deoxyribonucleic acid (DNA) demethylase (using MBD2 as an example) activity assay by coupling the fluorescence quenching of graphene oxide (GO) with the site-specific cleavage of HpaII endonuclease to improve the selectivity. This approach was developed by designing a single-stranded probe (P1) that carries a binding region to facilitate the interaction with GO, which induces fluorescence quenching of the labeled fluorophore (FAM, 6-carboxyfluorescein), and a sensing region, which contains a hemi-methylated site of 5′-CmCGG-3′, to specifically recognize the target (T1, a 32-mer DNA from the promoter region of p53 gene) and hybridize with it to form a P1/T1 duplex. After demethylation with MBD2, the duplex can be specifically cleaved using HpaII, which releases the labeled FAM from the GO surface and results in the recovery of fluorescence. However, this cleavage is blocked by the hemi-methylation of this site. Thus, the magnitude of the recovered fluorescence signal is related to the MBD2 activity, which establishes the basis of the DNA demethylase activity assay. This assay can determine as low as ∼(0.05 ± 0.01) ng mL−1 (at a signal/noise of 3) of MBD2 with a linear range of 0.2–300 ng mL−1 and recognize MBD2 from other possibly coexisting proteins and cancer cell extracts. The advantage of this assay is its ability to avoid false signals and no requirement of bisulfite conversion, PCR amplification, radioisotope labeling, or separation.  相似文献   

20.
We report on a novel graphene-based nanoarchitecture modified with plasma-polymerized propargylamine (G-PpPG) and its application in electrochemical sensors for DNA. Films of G-PpPG were characterized by X-ray photoelectron spectroscopy and electrochemical impedance spectroscopy. The presence of graphene enhances the electrochemical activity of the films, and the high density of amino groups (deposited at a low plasma input power) on their surface assists in the immobilization of probe DNA on the water-swollen polymeric network. By contrast, the degree of hybridization of the total complementary target DNA to the probe DNA remains unchanged when G-PpPG nanofilms prepared at higher input power. No substantial non-specific adsorption of totally mismatched target DNA on the polymer films is observed because of the complete coverage of the probe DNA. The detection limit for total complementary target DNA is approximately 1.84 nmol?·?L?1. The dynamic range extends from 0.1 to 1,000 nmol?·?L?1. The new nanocomposite may also be used to immobilize other probe DNA sequences, and this makes the approach potentially applicable to the detection of other oligomers. Figure
Preparing the DNA sensor made from the graphene-based nanoarchitecture modified by using PpPG (G-PpPG) includes the following processes: (a) Modifying the Au electrode with the graphene nanosheet, (b) depositing the PpPG film onto the Au electrode coated with graphene, (c) immobilizing the probe DNA onto the G-PpPG film, and (d) hybridizing the MM0 target with the G-PpPG film immobilized with P1  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号