首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 244 毫秒
1.
Local ion activity changes in close proximity to the surface of an oxygen depolarized cathode (ODC) were measured by scanning electrochemical microscopy (SECM). While the operating ODC produces OH? ions and consumes O2 and H2O through the electrocatalytic oxygen reduction reaction (ORR), local changes in the activity of OH? ions and H2O are detected by means of a positioned Pt microelectrode serving as an SECM tip. Sensing at the Pt tip is based on the pH‐dependent reduction of PtO and obviates the need for prior electrode modification steps. It can be used to evaluate the coordination numbers of OH? ions and H2O, and the method was exploited as a novel approach of catalyst activity assessment. We show that the electrochemical reaction on highly active catalysts can have a drastic influence on the reaction environment.  相似文献   

2.
At present, a highly sensitive hydrogen peroxide (H2O2) sensor is fabricated by ferrocene based naphthaquinone derivatives as 2,3‐Diferrocenyl‐1,4‐naphthoquinone and 2‐bromo‐3‐ferrocenyl‐1,4‐naphthoquinone. These ferrocene based naphthaquinone derivatives are characterized by H‐NMR and C‐NMR. The electrochemical properties of these ferrocene based naphthaquinone are investigated by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) on modified glassy carbon electrode (GCE). The modified electrode with ferrocene based naphthaquinone derivatives exhibits an improved voltammetric response to the H2O2 redox reaction. 2‐bromo‐3‐ferrocenyl‐1,4‐naphthoquinone show excellent non‐enzymatic sensing ability towards H2O2 response with a detection limitation of 2.7 μmol/L a wide detection range from 10 μM to 400 μM in H2O2 detection. The sensor also exhibits short response time (1 s) and good sensitivity of 71.4 μA mM?1 cm?2 and stability. Furthermore, the DPV method exhibited very high sensitivity (18999 μA mM?1 cm?2) and low detection limit (0.66 μM) compared to the CA method. Ferrocene based naphthaquinone derivative based sensors have a lower cost and high stability. Thus, this novel non‐enzyme sensor has potential application in H2O2 detection.  相似文献   

3.
Abstract

A number of challenges arise when using ferrocene as a component of electrochemical biosensors, including solubility in aqueous solutions. Therefore, entrapment of the biotin-ferrocene molecules within the chitosan film provides a route for immobilization on an electroactive surface such as an electrode while making the system water compatible. The use of the chitosan-ferrocene bioconjugate thin film on the electrode surface produces a signal that can be monitored in aqueous media. Herein, we discuss a series of modified ferrocene molecules that contain various linkers that provide non-covalent entanglement points to the chitosan medium. The electrochemical analysis and electron microscopy results show marked differences in the ferrocene loaded chitosan polymers when the termini of the ferrocene-linker vary between –SH and –NH2. The –SH modified systems showed increased reversible and robust electrochemical signals relative to the –NH2 congeners. Further studies showed that non-covalent impregnation strategy used is robust to degradation and less than 1% of the ferrocene molecules were leached over time. These results indicate that there are specific considerations needed when using chitosan-ferrocene systems as components in sensor arrays in future studies.  相似文献   

4.
A microelectrode array microprobe with a choline sensing site and an on‐probe reference electrode was constructed by depositing permselective polymer films and choline oxidase (ChOx) on one microelectrode, and iridium oxide (IrOx) on another, both of which were coated previously with a nanostructured Pt deposit. Scanning electron microscopy (SEM) of the nanostructured Pt layer revealed a unique pillar‐like, “nanograss” structure. Polyphenylenediamine (PPD) and Nafion were coated sequentially on the working (i. e. sensing) electrode surface to serve as the permselective polymer films. The microsensor exhibited high sensitivity to choline (123±13 μA mM?1 cm?2), low detection limit (3.2±0.8 μM), and fast response time (3–5 s). The choline sensor also was tested at physiological concentrations of electroactive interfering species common to brain extracellular fluid (i. e. ascorbic acid, dopamine, DOPA, and DOPAC) and showed excellent selectivity. Selectivity likely was aided by the relatively low potential of 0.35 V vs. IrOx that was made possible by the enhanced H2O2 electrooxidation activity of the underlying nanostructured Pt‐coated working electrode. Thus, Pt “nanograss” appears to be an excellent electrode surface modification for creation of high performance electroenzymatic biosensors.  相似文献   

5.
The carbon cavity microelectrode (CME), exhibiting a volume of 4×10?6 cm3, offers a genuine alternative for immobilizing and connecting enzymes in aqueous electrolytes by powder of insoluble redox materials. In the present work, the electrochemical behavior of two redox species such as ferrocene (Fc) and tetrathiafulvalene (TTF) was investigated with CME to evaluate their potentialities in the electrical wiring of enzymes. For this purpose, powder of two enzymes, glucose oxidase (GOx) and horseradish peroxidase (HRP), was independently mixed with an insoluble redox material and forced to fill the single micro cavity of a carbon electrode covered by an inert insulator. The presence of the electroactive species, as well as the enzyme wiring was investigated by cyclic voltammetry. The amperometric detection of glucose was carried out by potentiostating the TTF/GOx and the Fc/GOx microelectrodes at 0.25 and 0.35 V respectively. The amperometric detection of H2O2 by the TTF/HRP microelectrode was performed at ?0.1 V vs. SCE.  相似文献   

6.
《Electroanalysis》2017,29(11):2483-2490
In this study, the first application of a capillary zone electrophoresis‐electrochemical detection (CE‐ECD) method for concurrent determination of hydrogen peroxide (H2O2) and ascorbic acid (AA), was developed using the Pt nanoparticles (PtNPs) modified Pt micro‐disk electrode (PtME). The electrocatalytic activity of the modified electrode for H2O2 and AA was characterized by cyclic voltammetry. Under optimized experimental conditions, highly linear calibration plots were observed for both H2O2 and AA, with concentration linear ranges of 0.8 μM to 0.8 mM and 1.0 μM to 0.8 mM. Detection limits of 0.2 μM H2O2 and 0.5 μM AA were determined on the basis of the signal‐to‐noise characteristics (S/N=3) of an electropherogram. Compared with the unmodified PtME, the sensitivity was promoted in that PtNPs/PtME provided an increased effective electrode surface and high catalytic activity toward H2O2 and AA. Using this method, the added H2O2 and AA in Mizone, a kind of functional drink, were detected, and the concentration of AA was found to be 2.33 mM (n =3). The recovery rates were 95.3 % for H2O2 and 98.7 % for AA. The novel approach provided a wide linear range, low detection limit, good reproducibility and stability. It will provide a new insight into the balance of reactive oxygen species and antioxidant in biological systems.  相似文献   

7.
A green chemistry method to nano‐roughen a Pt disk microelectrode has been successfully developed via electrochemical alloying‐dealloying in an ionic liquid bath comprising of ZnCl2 and 1‐ethyl‐3‐methylimidazolium chloride. The nano‐roughened Pt layer possesses bark‐like nanoporous structures characteristic of nano‐sized aggregates separated by nano‐cracks whose width ranging from around 50 to 200 nm. The nano‐roughened microelectrode possesses high surface area and diffusional properties typical of a microelectrode. Electrochemical oxidation and reduction of nitrite have been studied as an example for demonstrating that the nano‐roughened microelectrode is a promising technique for electroanalysis and electrocatalysis applications.  相似文献   

8.
《Electroanalysis》2004,16(16):1318-1323
The electrochemical behavior of NO2 at Au/Nafion, Pt/Nafion and Pt‐Au/Nafion electrodes was investigated by using electrochemical and SEM methods, respectively. It was found that the Pt‐Au/Nafion electrode showed higher electrocatalytic activity than Pt/Nafion and Au/Nafion electrodes. The net current density of Au/Nafion electrode decayed significantly during the reaction, though it showed high initial value. Pt/Nafion and Pt‐Au/Nafion electrodes, on the contrary, showed good stability. A quantitative determination of NO2 concentration was carried out at Pt‐Au/Nafion electrode and a satisfactory linear relationship was found for the NO2 concentration in the range of 0–100 ppm.  相似文献   

9.
《Electroanalysis》2005,17(13):1160-1170
Analysis of aqueous solutions containing chlorinated phenol pollutants was accomplished by capillary electrophoresis with direct and indirect amperometric detection using a boron‐doped diamond microelectrode. The microelectrode was prepared by (i) coating a thin film of boron‐doped polycrystalline diamond on a sharpened platinum wire (76‐μm diameter) and (ii) sealing the coated wire in a polypropylene pipet tip. The diamond microelectrode, used in end‐column detection, exhibited a low and stable background current with low peak‐to‐peak noise and good electrochemical activity for the pollutants without any conventional pretreatment. The electrode performance was evaluated in terms of the linear dynamic range, sensitivity, limit of quantitation, and response precision for the detection of several priority pollutants (2‐chlorophenol, 3‐chlorophenol, 4‐chlorophenol, 2,4‐dichlorophenol, 2,4,6‐trichlorophenol, and pentachlorophenol). The diamond microelectrode gave good detection figures of merit for these contaminants in the direct amperometric mode with no evidence of any electrode fouling. As an example, the concentration limit of quantitation for 2‐chlorophenol was 100 nM or 13 ppb (S/N=3) and the relative standard deviation of the peak height for 9 injections was 4.7±0.5% (est. 1.1 nL inj.). The separation efficiency was greater than 100 000 plates/m for all seven solutes. The microelectrode was also employed for the indirect detection of the chlorinated phenols. In this approach, which is useful for detecting electroinactive solutes, ferrocene carboxylic acid was added to the run buffer as the electrophore. Good detection figures of merit were also achieved for the separation and detection of 2‐chlorophenol, 3‐chlorophenol, and 2,4‐dichlorophenol in this mode, although the linear dynamic range was not as wide and the limit of quantitation was not as low as in direct amperometry. For example, the concentration limit of quantitation for these pollutants was in the mid micromolar range (1–10 ppm) with excellent response reproducibility of 3.2±0.8%, or less.  相似文献   

10.
Ionic liquids provide high viscosity solvent environments with interesting voltammetric characteristics and new electrochemical mechanisms. Here, a gold‐gold dual‐plate microtrench electrode is employed in generator‐collector mode to enhance viscosity‐limited currents in ionic liquids due to fast feedback within small inter‐electrode gaps (5 μm inter‐electrode gap, 27 μm microtrench depth) and to provide a mechanistic diagnosis tool. Three redox systems in the ionic liquid BMIm+BF4? are investigated: (i) ferrocene oxidation, (ii) oxygen reduction, and (iii) 2‐phenyl‐naphthyl‐1,4‐dione reduction. Both transient and steady state voltammetric responses are compared. Asymmetric diffusion processes, reaction intermediates, and solubility changes in the ionic liquid are revealed.  相似文献   

11.
We report here a nonenzymatic sensor by using a nanoporous platinum electrode to detect glucose directly. The electrode was fabricated by electrochemical deposition and dissolution of PtZn alloy in zinc chloride‐1‐ethyl‐3‐methylimidazolium chloride (ZnCl2‐EMIC) ionic liquid. Both SEM and electrochemical studies showed the evidences for the nanoporous characteristics of the as‐prepared Pt electrodes. Amperometric measurements allow observation of the electrochemical oxidation of glucose at 0.4 V (vs. Ag/AgCl) in pH 7.4 phosphate buffer solution. The sensor also demonstrates significant reproducibility in glucose detection; the higher the roughness factor of the Pt electrode, the lower the detection limit of glucose. The interfering species such as ascorbic acid and p‐acetamidophenol can be avoided by using a Pt electrode with a high roughness factor of 151. Overall, the nanoporous Pt electrode is promising for enzymeless detection of glucose at physiological condition.  相似文献   

12.
《Electroanalysis》2017,29(6):1518-1523
A sensitive and selective amperometric H2O2 biosensor was obtained by utilizing the electrodeposition of Pt flowers on iron oxide‐reduced graphene oxide (Fe3O4/rGO) nanocomposite modified glassy carbon electrode (GCE). The morphology of Fe3O4/rGO and Pt/Fe3O4/rGO was characterized by transmission electron microscopy (TEM) and scanning electron microscopy (SEM), respectively. The step‐wise modification and the electrochemical characteristics of the resulting biosensor were characterized by cyclic voltammetry (CV) and chronoamperometry methods. Thanks to the fast electron transfer at the Pt/Fe3O4/rGO electrode interface, the developed biosensor exhibits a fast and linear amperometric response upon H2O2. The linear range of Pt/Fe3O4/rGO is 0.1∼2.4 mM (R2=0.998), with a sensitivity of 6.875 μA/mM and a detection limit of 1.58 μM (S/N=3). In addition, the prepared biosensor also provides good anti‐interferent ability and long‐term stability due to the favorable biocompatibility of the electrode interface. The proposed sensor will become a reliable and effective tool for monitoring and sensing the H2O2 in complicate environment.  相似文献   

13.
Pt-Ni alloy nanoparticles were produced by casting 2 or 10 mM H2PtCl6 solutions on a Ni column. The apparent particle size for the resultant Pt-Ni alloys increased with the concentration of the H2PtCl6 solution, while the content of Pt in the alloy decreased. The potential sweeps of 5 cycles in an H2SO4 aqueous solution for Pt-Ni (2 mM)/Ni and Pt-Ni (10 mM)/Ni electrodes led to electrochemical behavior similar to a polycrystalline Pt electrode, suggesting the formation of a few thin Pt layers on each Pt-Ni alloy surface. In electrochemical measurements, both Pt-Ni/Ni electrodes showed more negative onset potential of methanol oxidation and slower degradation of oxidation current of methanol than the polycrystalline Pt electrode. X-ray photoelectron spectroscopy of both Pt-Ni/Ni electrodes showed the shift of Pt4f peaks to a higher binding energy, suggesting that the increase in the d vacancy in the balance band 5d orbital of Pt contributed to the improved electrocatalytic activity and durability of the Pt-Ni/Ni electrodes.  相似文献   

14.
Abstract

The hydrolysis of cephanone in water, cetyl trimethyl ammonium bromide (CTAB) micelle, and CTAB/n‐C5H11OH/H2O O/W microemulsion was studied through UV‐VIS absorption spectroscopy. The mechanism of the hydrolysis and the effects of both the acidity of the media and the composition of O/W microemulsion on the hydrolysis were studied. The results show that the hydrolysis rate of cephanone increases with the acidity. Compared with water, CTAB micelle and CTAB/n‐C5H11OH/H2O O/W microemulsion suppress this hydrolysis. The inhibition of the hydrolysis of cephanone by CTAB micelle and CTAB/n‐C5H11OH/H2O O/W microemulsion is related to the location of cephanone in the interphases of CTAB micelles and CTAB/n‐C5H11OH/H2O O/W microemulsion droplets.  相似文献   

15.
WO3 has been prepared via thermal decomposition of ammonium paratungstate. The obtained oxide has been characterized by X‐ray diffraction (XRD) spectroscopy. The particle size was found to increase with increasing calcination temperature. The modified Pt/WO3/GC electrode has been prepared and characterized using various analytical and electrochemical techniques. The electrochemical oxidation of ethylene glycol (EG) on the modified electrode was investigated and compared with that of a Pt/GC electrode in acidic solution. The presence of WO3 enhanced the electrode activity towards EG oxidation. The enhancement factor was found to depend on the ratio of WO3:Pt as well as on the calcination temperature during WO3 preparation  相似文献   

16.
《Electroanalysis》2006,18(23):2314-2323
Some dithiophosphonate derivatives were synthesized and the electrochemical reduction mechanism was investigated by cyclic voltammetry (CV), square wave voltammetry (SWV) and chronoamperometry (CA) in 0.1 M tetrabutylammoniumtetrafluoroborate (TBATFB) in acetonitrile at platinum (Pt) and gold (Au) electrodes. Dithiophosphonates showed a cyclic voltammetric reduction peak at about ?1.1 V at Pt and ?1.3 V at Au electrode (vs. Ag/Ag+) in this media. It was also shown that dithiophosphonates can be determined quantitatively in acetonitrile using a calibration graph. The number of electrons transferred were calculated as 2 using ferrocene as a reference compound at the UME electrode. Mechanism of dithiophosphonates was also examined on Pt and Au electrodes and electrochemical reduction of dithiophosphonates seems to follow an EC mechanism with an irreversible electron transfer step. The reaction product in the bulk electrolysis experiment was isolated and identified using proton‐coupled P‐31 NMR, 13C‐NMR and IR spectroscopy. The adsorption tests for dithiophosphonates were revealed that no strong or weak adsorption phenomena exist on both Pt and Au electrodes. Simulation curves were acquired by DigiSim 3.03 version to investigate the reduction mechanism and to estimate the kinetic parameters for electrochemical and chemical steps.  相似文献   

17.
End-column electrochemical detection based on either the use of a 25 μm microdisk electrode or a 0.5 mm macrodisk electrode has been compared with respect to performance and influence on non-aqueous capillary electrophoretic separations. Despite the much higher coulometric efficiency obtained with the larger disk electrode, the microdisk electrode configuration offers comparable limits of detection (LOD) for the neutral and positively charged ferrocene compounds employed in conjunction with a non-aqueous acetonitrile-based buffer. The LODs for ferrocene were found to be 4.0 × 10–8 M and 6.7 × 10–8 M for the microdisk and macrodisk detector, respectively. In addition, both detector arrangements showed different relative responses for neutral and positively charged analytes. The macroelectrode-based detector introduced additional zone broadening while this was not found to be the case with the microelectrode arrangement. Using the microelectrode detector, the band broadening in an electro-osmotically driven flow system was compared to that in a gravity flow-based system. It was demonstrated that the zone broadening under gravity flow conditions was approximately twice as large as under electro-osmotic flow conditions for a typical set of experimental parameters.  相似文献   

18.
End-column electrochemical detection based on either the use of a 25 μm microdisk electrode or a 0.5 mm macrodisk electrode has been compared with respect to performance and influence on non-aqueous capillary electrophoretic separations. Despite the much higher coulometric efficiency obtained with the larger disk electrode, the microdisk electrode configuration offers comparable limits of detection (LOD) for the neutral and positively charged ferrocene compounds employed in conjunction with a non-aqueous acetonitrile-based buffer. The LODs for ferrocene were found to be 4.0 × 10–8 M and 6.7 × 10–8 M for the microdisk and macrodisk detector, respectively. In addition, both detector arrangements showed different relative responses for neutral and positively charged analytes. The macroelectrode-based detector introduced additional zone broadening while this was not found to be the case with the microelectrode arrangement. Using the microelectrode detector, the band broadening in an electro-osmotically driven flow system was compared to that in a gravity flow-based system. It was demonstrated that the zone broadening under gravity flow conditions was approximately twice as large as under electro-osmotic flow conditions for a typical set of experimental parameters. Received: 1 June 1998 / Revised: 20 August 1998 / Accepted: 24 August 1998  相似文献   

19.
《Analytical letters》2012,45(14):1717-1722
Abstract

An electrode consisting of platinized reticulated vitreous carbon (Pt/RVC) which behaves as a conventional platinized platinum electrode is described. The Pt/RVC electrode has been used to study the products of CO2 reduction by Had at potentials below 0.0V vs. NHE in acidic solution. Formic acid is proposed as the main product of this reaction.  相似文献   

20.
An aluminum electrode modified with gold atoms was introduced as a novel electrode. Gold atoms were deposited both chemically and electrochemically onto the aluminum electrode to make an aluminum/gold (Al/Au) modified electrode (ME). The experimental results showed that the Al/Au modified electrode prepared by chemical deposition, exhibits much more current than the electrochemical deposition method. The electrochemical behavior of the Al/Au modified electrode was studied by cyclic voltammometry. This modified electrode showed two pairs of peaks, a1c1 and a2c2, with surface‐confined characteristics in a 0.5 M phosphate buffer. The dependence of Epa of the second peak (a2c2) on pH shows a Nernestian behavior with a slope of 55 mV per unit pH. The effect of different supporting electrolytes, solution's pH and different scan rates on electrochemical behavior of Al/Au modified electrode was studied. Au deposited electrochemically on a Pt electrode (Pt/Au) was also used as another modified electrode. A comparative study of electrochemical behavior of bare Al, Pt/Au and Al/Au modified electrodes showed that both Pt/Au and Al/Au electrodes have the ability of electrocatalytic oxidation of S2O32?, but the electrocatalytic oxidation on the latter was better than the former. The kinetics of the catalytic reaction was investigated by using cyclic voltammetry and chronoamperometry techniques. The average value of the rate constant for the catalytic reaction and the diffusion coefficient were evaluated by means of chronoamperometry technique.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号