 共查询到20条相似文献,搜索用时 46 毫秒
1.
Prussian blue (PB) is an electrochromic material, which can be used as a signal transducer in the formation of optical urea biosensors. The previous researches in electrochromic properties of PB demonstrated the optical PB response to ammonium ions, which occurs when ammonium ions are interacting with PB layer at a constant 0.2 V vs Ag|AgCl|KClsat potential. In this work PB optical dependence on ammonium ions concentration was applied in the formation of electrochromic urea biosensor. Biosensor was formed by modifying the optically transparent indium tin oxide (ITO) coated glass electrode (glass/ITO) with Prussian blue layer and immobilizing urease (glass/ITO/PB‐urease). Calibration curve showed the linear dependency (R2=0.995) between the change of maximal absorbance (ΔA) and urea concentration in concentration range varying from 3 mM to 30 mM. The highest sensitivity (4 ΔA M?1) of glass/ITO/PB‐urease biosensor is in the concentration range from 7 mM to 30 mM. It was determined that working principle of the glass/ITO/PB‐urease biosensor is not related to pH changes occurring during enzymatic hydrolysis of urea.  相似文献   

2.
An improved urea enzyme electrode is applied for the determination of urea in blood samples. The electrode is based on the enzymatic hydrolysis of urea, and potentiometric detection of the ammonium ion produced. A silicone rubber-based nonactin ammonium ion-selective electrode serves as the sensor. The selectivity coefficients of this electrode were 6.5 for NH4+/K+; 750 for NH4+/Na+, and much higher for other cations. The reaction layer of the electrode was made of urease enzyme chemically immobilized on polyacrylic gel. The prepared gel was stable at 4° for over four months. The electrodes retained their activity for over one month. A three-electrode system, which allowed dilution to a constant interference level, was applied to avoid interfering effects in blood samples. Analyses of blood sera showed good agreement with a standard spectrophotometric method. Routine clinical assays of blood urea are feasible.  相似文献   

3.
An optical biosensor for urea based on urease enzyme immobilised on functionalised calcium carbonate nanoparticles (CaCO3-NPs) was successfully developed in this study. CaCO3-NPs were synthesised from discarded cockle shells via a simple and eco-friendly approach, followed by surface functionalisation with succinimide ester groups. The fabricated biosensor is comprised of two layers. The first (bottom layer) contained functionalised NPs covalently immobilised to urease, and the second (uppermost layer) was alginate hydrogel physically immobilised to the pH indicator phenolphthalein. The biosensor provided a colorimetric indication of increasing urea concentrations by changing from colourless to pink. Quantitative urea analysis was performed by measuring the reflectance intensity of the colour change at a wavelength of 633.16 nm. The determination of urea concentration using this biosensor yielded a linear response range of 30–1000 mM (R2 = 0.9901) with a detection limit of 17.74 mM at pH 7.5. The relative standard deviation of reproducibility was 1.14%, with no signs of interference by major cations, such as K+, Na+, NH?+, and Mg2+. The fabricated biosensor showed no significant difference with the standard method for the determination of urea in urine samples.  相似文献   

4.
The urease enzyme of Helicobacter pylori was isolated from biopsy sample obtained from antrum big curvature cell extracts. A new urea biosensor was prepared by immobilizing urease enzyme isolated from Helicobacter pylori on poly(vinylchloride) (PVC) ammonium membrane electrode by using nonactine as an ammonium ionophore. The effect of pH, buffer concentration, and temperature for the biosensor prepared with urease from H. pylori were obtained as 6.0, 5 mM, and 25 °C, respectively. We also investigated urease concentration, stirring rate, and enzyme immobilization procedures in response to urea of the enzyme electrode. The linear working range of the biosensor extends from 1 × 10(-5) to 1 × 10(-2) M and they showed an apparent Nernstian response within this range. Urea enzyme electrodes prepared with urease enzymes obtained from H. pylori and Jack bean based on PVC membrane ammonium-selective electrode showed very good analytical parameters: high sensitivity, dynamic stability over 2 months with less decrease of sensitivity, response time 1-2 min. The analytical characteristics were investigated and were compared those of the urea biosensor prepared with urease enzyme isolated from Jack bean prepared at the same conditions. It was observed that rapid determinations of human serum urea amounts were also made possible with both biosensors.  相似文献   

5.
Magalhães JM  Machado AA 《Talanta》1998,47(1):183-191
Potentiometric biosensors based on urease (E.C. 3.5.1.5.) immobilized on chitosan membranes coupled to all-solid-state nonactin ammonium ion selective electrodes are described. The enzyme was immobilized on the chitosan membranes by four procedures: (A) adsorption; (B) adsorption followed by reticulation with dilute aqueous glutaraldehyde solution; (C) activation with glutaraldehyde followed by contact with the enzyme solution; and (D) activation with glutaraldehyde, contact with the enzyme solution and reduction of the Schiff base with sodium borohydride. The response characteristics of the biosensors obtained with these enzymatic membranes were determined and compared. The biosensor with best response characteristics, obtained by procedure (B), showed the following characteristics of response to urea: (i) linearity in the 10(-4) to 10(-2) M range; (ii) slope of up to 56 mV per decade; (iii) response time between 30 s and 2 min; and (iv) lifetime of 2 months. This biosensor was tested in the determination of urea in blood serum samples.  相似文献   

6.
《Analytical letters》2012,45(5):283-293
Abstract

The enzyme urease was immobilized in a layer of acrylamide polymer on the surface of a Beckman cationic electrode sensitive to ammonium ion. The substrate urea diffuses to the enzyme electrode and reacts with the immobilized enzyme to produce ammonium ion at the surface of the glass electrode. By placing a thin film of cellophane around the enzyme gel layer to prevent leaching of urease into the surrounding solution, an electrode could be used continuously for over 21 days at 25[ddot]C with no loss of activity.  相似文献   

7.
Different modifications of the zeolites Na+‐Beta and LTA were applied for improving the working characteristics of a urea biosensor. The bioselective membrane of the biosensor was based on urease and different zeolites co‐immobilized with bovine serum albumin on the surface of a pH‐FET. It was shown that the biosensors modified with the zeolites H+‐Beta30 and H+‐Beta50 are characterized by increased sensitivity to urea. The influence of the zeolite concentration on the sensitivity of the biosensors was studied. The optimal concentration of the zeolites H+‐Beta30 and H+‐Beta50 in the bioselective membrane was 15 %. Different variants of co‐immobilization of urease and zeolite H+‐Beta30 were studied and the optimal method was selected. Thus, a general conclusion is that the urea biosensor sensitivity can be improved using zeolite H+‐Beta30 for urease immobilization in the bioselective membrane.  相似文献   

8.
A fiber-optic biosensor for urea is described. This biosensor is based on the immobilization of urease at the sensing tip of a fluorescence-based ammonia gas-sensing fiber-optic chemical sensor. Urease is immobilized on a Teflon membrane by the well known bovine serum albumin (BSA)/glutaraldehyde cross-linking method. The indicator solution for this biosensor is composed of 0.145 M sodium chloride, 5.00 mM ammonium chloride, 9.4 μM 2′,7′-bis(carboxyethyl)-5 (and 6)-carboxyfluorescein and 0.9 μM 5 (and 6)-carboxyfluorescein. The steady-state and dynamic response properties of the sensor have been established. Results show that the urease/BSA protein layer has a significant effect on sensor response and recovery times. Also, the fluorescence-based sensor has been found to be faster than a conventional potentiometric ammonia gas-sensing electrode. In addition, the fluorescence sensor responds significantly quicker than a similar absorbance-based fiber-optic urea biosensor. The utility of the resulting urea biosensor for the determination of urea in diluted serum samples is demonstrated.  相似文献   

9.
《Analytical letters》2012,45(5):790-806
Abstract

A new absorbance-based enzymatic biosensor for determination of urea (in the range 0.01 to 6.7 mM) is described. Quantification using cresol red dye, immobilized in the nanofilm coatings assembled on alginate microspheres to immobilize the urease enzyme, has been accomplished using ratiometric absorbance measurements. The effect of salt concentration in polyelectrolyte nanofilms (on the stability of dye molecules) and buffer pH (on the enzyme stability) are reported. The results demonstrate excellent stability of sensing assay within alginate microspheres. Urea-sensing experiments demonstrate the potential to develop an optical urea sensor that is stable over a month.  相似文献   

10.
A possibility of efficient urease adsorption on silicalite for the purpose of biosensor creation was investigated. The procedure of urease adsorption on silicalite is notable for such advantages as simple and fast performance and non‐use of toxic or auxiliary compounds. Optimal conditions for modifying transducer surfaces with silicalite and subsequent urease adsorption on these surfaces were selected. The working parameters of the created biosensor were optimized. The developed biosensor with adsorbed urease was characterized by good intra‐reproducibility (RSD – 4.5 %), improved inter‐reproducibility (RSD of urea determination is 9 %) and operational stability (less than 10 % loss of activity after 10 days). Besides, the developed method for enzyme adsorption on silicalite was compared with the traditional methods of urease immobilization in biosensorics. Working conditions of the produced biosensor (pH and ionic strength) were shown to be close to those of the biosensor based on urease immobilized in GA vapor. For these reasons, it was concluded that the method of enzyme adsorption on silicalite is well‐suited for biosensor standardization aimed at its further manufacture.  相似文献   

11.
《Analytical letters》2012,45(15):1345-1357
Abstract

A new type of potentiometric ammonia gas sensor is employed in the preparation of selective bio-electrodes for urea and glutamine. The bio-electrodes are constructed by immobilizing the enzyme urease and intact porcine kidney cells, respectively, at the surface of a disposable ammonium selective polymer membrane electrode-based ammonia gas sensor. The resulting electrodes have favorable response properties when compared to corresponding devices previously assembled with costly commercial gas sensors. Preliminary studies with the urea electrode demonstrate its usefulness for the rapid determination of urea in serum samples.  相似文献   

12.
Nickel oxide nanoparticle (NiO?NP) and polypyrrole (PPy) composite were deposited on a Pt electrode for fabrication of a urea biosensor. To develop the sensor, a thin film of PPy?NiO composite was deposited on a Pt substrate that serves as a matrix for the immobilization of enzyme. Urease was immobilized on the surface of Pt/PPy?NiO by a physical adsorption. The response of the fabricated electrode (Pt/PPy?NiO/Urs) towards urea was analyzed by chronoamperometry and cyclic voltammetry (CV) techniques. Electrochemical response of the bio‐electrode was significantly enhanced. This is due to electron transfer between Ni2+ and Ni3+ as the electro‐catalytic group and the reaction between polypyrrole and the urease‐liberated ammonium. The fabricated electrode showed reliable and demonstrated perfectly linear response (0.7–26.7 mM of urea concentration, R2= 0.993), with high sensitivity (0.153 mA mM?1 cm?2), low detection of limit (1.6 μM), long stability (10 weeks), and low response time (~5 s). The developed biosensor was highly selective and obtained data were repeatable and reproduced using PPy‐NiO composite loaded with immobilized urease as urea biosensors.  相似文献   

13.
A simple optical fibre biosensor based on immobilised enzyme for monitoring of trace heavy metal ions has been developed. The biosensor recognition system was designed based on the inhibition of urease activity, where the urease is immobilised on ultrabind membrane. The studies of inhibition by the heavy metal ions Hg(II), Ag(I), Cu(II), Ni(II), Zn(II), Co(II) and Pb(II) were performed using a fibre-optic biosensor configuration, where the pH change resulting from the bio-catalytic hydrolysis of urea was monitored at the wavelength 615 nm spectroscopically, using commercial pH indicator strip before and after the exposure to the heavy metal ions. The immobilised urease was regenerated by l-cysteine. The linear response range between 1×10-9–1×10-5 M and the limit of detection 1×10-9 M (0.2 g/L) for Hg(II) ions was achieved by employing the flow method. The optimisation of experimental parameters, including flow method, is also discussed.  相似文献   

14.
In this article, a mathematical model was developed to describe and optimize the configuration of the urea biosensor. The biosensor is based on interdigitated gold microelectrodes modified with a urease enzyme membrane. The model presented here focuses on the enzymatic reaction and/or diffusion phenomena that occur in the enzyme membrane and in the diffusion layer. Numerical resolution of differential equations was performed using the finite difference technique. The mathematical model was validated using experimental biosensor data. The responses of the biosensor to various conditions were simulated to guide experiments, improve analytical performance, and reduce development costs.  相似文献   

15.
《Analytical letters》2012,45(11):969-975
Abstract

An enzyme electrode specific for the substrate urea is described. The electrode consists of a layer of urease polymerized directly on to the surface of the gas diffusion membrane of an ammonia probe by means of glutaraldehyde. The calibration curves obtained when the electrode is allowed to measure in buffered solutions are discussed in terms of enzyme activity and pH-gradients in the membrane.  相似文献   

16.
In this work, urea detection techniques based on the pH sensitivity of CdSe/ZnS QDs were developed using three types of sol-gel membranes: a QD-entrapped membrane, urease-immobilized membrane and double layer consisting of a QD-entrapped membrane and urease-immobilized membrane. The surface morphology of the sol-gel membranes deposited on the wells in a 24-well microtiter plate was investigated. The linear detection range of urea was in the range of 0-10 mM with the three types of sol-gel membranes. The urea detection technique based on the double layer consisting of the QD-entrapped membrane and urease-immobilized membrane resulted in the highest sensitivity to urea due to the Michaelis-Menten kinetic parameters. That is, the Michaelis-Menten constant (Km =2.0745 mM) of the free urease in the QD-entrapped membrane was about 4-fold higher than that (Km =0.549 mM) of the immobilized urease in the urease-immobilized membrane and about 12-fold higher than that (Km =0.1698 mM) of the immobilized urease in the double layer. The good stability of the three sol-gel membranes for urea sensing over 2 months showed that the use of sol-gel membranes immobilized with QDs or an enzyme is suitable for biomedical and environmental applications.  相似文献   

17.
《Analytical letters》2012,45(9):457-464
Abstract

A new ammonium ion selective electrode has been developed and found to be capable of measuring ammonium ion in the presence of other cations. The electrode's selectivity over other cations is reported as well as its response time to step changes in ammonium ion activity. In addition, blood serum samples have been analyzed for urea content by treatment with urease with no special sample pre-treatment required.  相似文献   

18.
A biosensor for the determination of urea in human serum was fabricated using a combination of inkjet printed polyaniline nanoparticles and inkjet printed urease enzyme deposited sequentially onto screen-printed carbon paste electrodes. Chronocoulometry was used to measure the decomposition of urea via the doping of ammonium at the polyaniline-modified electrode surface at -0.3 V vs. Ag/AgCl. Ammonium could be measured in the range from 0.1 to 100 mM. Urea could be measured by the sensor in the range of 2-12 mM (r(2)=0.98). The enzyme biosensor was correlated against a spectrophotometric assay for urea in 15 normal human serum samples which yielded a correlation coefficient of 0.85. Bland-Altman plots showed that in the range of 5.8-6.6 mM urea, the developed sensor had an average positive experimental bias of 0.12 mM (<2% RSD) over the reference method.  相似文献   

19.
Radomska A  Glab S  Koncki R 《The Analyst》2001,126(9):1564-1567
A spectrophotometric flow-injection analysis (FIA) system for monitoring clinical hemodialysis is demonstrated. The role of a dialysate urea detector incorporated in this bioanalytical system is played by an optical flow-through biosensor based on Prussian Blue film with chemically linked urease forming a monomolecular layer of the enzyme. This pH-enzyme optode-FIA system is useful for the selective determination of post-dialysate urea in the range of concentration corresponding to its level in real clinical samples (2-16 mmol l(-1)). This bioanalytical system allows the analysis of about 15 samples of spent dialysate per hour. The operational and storage stabilities of the applied biosensor are longer than 2 weeks and 2 months, respectively. Clinical evaluation of the bioanalytical system was performed.  相似文献   

20.
Ion-selective electrode with cellulose triacetate membrane containing nonactin is employed for the potentiometric detection of ammonia produced in biocatalytic reaction in flow-injection system with enzyme reactor. The elimination of interferences occurring in the presence of alkali metal ions was achieved by covering a nonactin membrane with outer hydrophobic gas permeable membrane. The obtained flow-injection response to ammonia indicates a possibility of ammonia determination down to 10 microM ammonia. In the flow-injection system for urea determination 200 microl of 10-fold diluted blood serum sample was injected into carrier stream of distilled water merged with TRIS buffer, passed through the urease flow-through reactor and then after merging with NaOH stream delivered to the detector. It was found in several series of natural blood serum samples, that the correction for endogenous ammonia in such a determination is not indispensable.  相似文献   