首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《Analytical letters》2012,45(1-3):137-145
A sensitive flow injection chemiluminescence (CL) method is proposed for the determination of bovine serum albumin (BSA) using Copper(II)-Alizarin Red S (ARS) complex as an efficient chemiluminescent probe. The detection is based on the binding of the copper(II)-ARS complex to proteins and the catalytic activity of copper(II)-ARS in the luminol-H2O2 CL system. Under the selected conditions, the CL intensity is linear with the concentration of BSA in the range of 5.0 × 10?11 to 1.0 × 10?9 mol · L?1. The detection limit was 2.0 × 10?11 mol · L?1. The method is successfully applied to the determination of protein in urine.  相似文献   

2.
《Analytical letters》2012,45(12):1857-1867
Abstract

A new flexible minisensor based on MnO2/graphite/epoxy resin composite for the potentiometric determination of hydrogen peroxide was developed in this work. Under optimum experimental conditions, such as 25°C, 4 h of conditioning time in 0.1 mol L?1 NH3‐NH4 + buffer solution (pH 8.5) and a composition of 10/60/30% w/w MnO2/graphite/epoxy resin, respectively, the minisensor presented a Nernstian response for H2O2 in the concentration range from 6.0×10?7 to 1.0×10?3 mol L?1, with a slope of ?58.5±0.2 mV/pH2O2 with a detection limit of 1.6×10?8 mol L?1 H2O2. The useful lifetime of the proposed minisensor was at least 6 months (over 670 determinations for each composite), the response time was smaller than 1.5 min, and it was successfully applied in the determination of hydrogen peroxide in bleach and pharmaceutical products.  相似文献   

3.
A composite electrode was fabricated from Cu2O powder, carboxyl-functionalized multi-wall carbon nanotubes (MWCNT-COOH), and paraffin oil in the proportions 51:17:32 (w/w). This composite electrode was used for amperometric detection (CZE–AD) in simultaneous capillary zone electrophoretic analysis of chlorogenic acid, rutin, sucrose, glucose, mannose, and fructose in tobacco samples. Under the optimum conditions, the six analytes could be separated in 100 mmol L?1 NaOH buffer within 30 min. Good linearity was achieved in the range 1 × 10?7–1 × 10?4 mol L?1 for the two polyphenols and 5 × 10?6–1 × 10?3 mol L?1 for the four sugars. The detection limits (S/N = 3) for the polyphenols and sugars were as low as 10?8 mol L?1 and 10?6 mol L?1, respectively.  相似文献   

4.
A novel flow injection procedure has been developed for the determination of tannic acid based on the inhibition of the chemiluminescences in luminol-H2O2-Manganese tetrasulfonatophthalocyanine (MnTSPc) system by tannic acid. The method is simple, rapid and sensitive with a detection limit of 8 × 10−10 mol·L−1 and a linear range of 7 × 10−9–5 × 10−6 mol·L−1. The relative standard deviation is 1.9% for eleven measurements of 5 × 10−7 mol·L−1 tannic acid. The method has been successfully applied to the determination of tannic acid in real Chinese gall and hop pellets samples.  相似文献   

5.
《Analytical letters》2012,45(9):1086-1097
A new automated method is reported for the determination of H2O2 in real samples. The method is based on the quenching effect of the analyte on the reaction between tris(2-carboxyethyl)phosphine (TCEP) and Ellman's reagent (DTNB). All necessary steps were accomplished under flow conditions using a hybrid sequential injection (SI)/flow injection (FI) setup. The sensitivity was enhanced by applying a stopped-flow step (120 s) in order to promote the reaction between H2O2 and TCEP. The proposed analytical protocol was validated for linearity (10–75 µmol L?1), limits of detection (c L = 1.0 µmol L?1), quantitation (c Q = 3.3 µmol L?1), precision (s r = 1.3–1.7%), accuracy, and selectivity. It was then applied successfully to the analysis of H2O2 in spiked rainwater and snow samples.  相似文献   

6.
In the present work, a novel flow-injection chemiluminescence method based on CdTe quantum dots (QDs) was developed for the determination of nitrite. Weak chemiluminescence (CL) signals were observed from a CdTe QDs–H2O2 system under basic conditions. The addition of a trace amount of hemoglobin (Hb) caused the CL from the CdTe QDs–H2O2 system to increase substantially. In the presence of nitrite, the ferrous Hb reacted with the nitrate to form ferric Hb and NO. The NO then bound to ferrous Hb to generate iron nitrosyl Hb. As a result, the CL signal from the CdTe QDs–H2O2–Hb system was quenched. Thus, a flow-injection CL analytical system for the determination of trace nitrite was established. Under optimum conditions, there was a good linear relationship between CL intensity and the concentration of nitrite in the range 1.0?×?10?9 to 8.0?×?10?7 mol L?1 (R 2?=?0.9957). The limit of detection for nitrite using this system was 3.0?×?10?10 mol L?1 (S/N?=?3). This method was successfully applied to detect nitrite in water samples.
Figure
The scheme of the mechanism of the CL system  相似文献   

7.
《Analytical letters》2012,45(5):885-897
Hemoglobin (Hb) was successfully immobilized on a gold electrode modified with gold nanoparticles (AuNPs) via a molecule bridge 1,6-hexanedithiol (HDT). The AFM images suggested that the HDT/gold electrode could adsorb more AuNPs. UV-vis spectra indicated that Hb on AuNPs/HDT film retained its near-native secondary structures. The electrochemical behaviors of the sensor were characterized with cyclic voltammetric techniques. The resultant electrode displayed an excellent electrocatalytical response to the reduction of hydrogen peroxide (H2O2). The linear relationship existed between the catalytic current and the H2O2 concentration ranging from 5.0 × 10?8 to 1.0 × 10?6 mol · L?1. The detection limit (S/N = 3) was 1.0 × 10?8 mol · L?1.  相似文献   

8.
《Analytical letters》2012,45(11):1721-1734
Abstract

A novel approach to assemble an H2O2 amperometric biosensor was introduced. The biosensor was constructed by entrapping horseradish peroxidase (HRP) labeled nano‐scaled particulate gold (nano‐Au) (HRP‐nano‐Au electrostatic composite) in a new silica sol‐gel/alginate hybrid film using glassy carbon electrode as based electrode. This suggested strategy fully merged the merits of sol‐gel derived inorganic‐organic composite film and the nano‐Au intermediator. The silica sol‐gel/alginate hybrid material can improve the properties of conventional sol‐gel material and effectively prevent cracking of film. The entrapment of HRP in the form of HRP‐nano‐Au can not only factually prevent the leaking of enzyme out of the film but also provide a favorable microenvironment for HRP. With hydroquinone as an electron mediator, the proposed HRP electrode exhibited good catalytic activity for the reduction of H2O2. The parameters affecting both the qualities of sol‐gel/alginate hybrid film and the biosensor response were optimized. The biosensor exhibited high sensitivity of 0.40 Al mol?1 cm?2 for H2O2 over a wide linear range of concentration from 1.22×10?5 to 1.46×10?3 mol L?1, rapid response of <5 s and a detection limit of 0.61×10?6 mol L?1. The enzyme electrode has remarkable stability and retained 86% of its initial activity after 45 days of storage in 0.1 mol L?1 Tris‐HCl buffer solutions at pH 7.  相似文献   

9.
The boron-doped diamond (BDD) presents attractive electrochemical sensing characteristics that are useful in analytical applications based on voltammetry and amperometry. It has a wide potential window in aqueous solutions enabling the quantification of the fungicide trifloxystrobin, measured at +1744 mV (versus Ag/AgCl), by square-wave anodic voltammetry in a Britton–Robinson (BR) buffer (0.04 mol L?1; pH 4.00)/acetonitrile 70/30% v/v. The activation of the electrode was made using galvanostatic chronopotentiometry and cyclic voltammetry (CV). The linear analyte addition curve, Ip (µA) = (1.0 × 10–1 ± 4.8 × 10–6) C (mol L?1) + (8.8 × 10–2 ± 1.1 × 10–3); R2 = 0.997, was obtained using amplitude of 40 mV, frequency of 30 Hz, step potential of 20 mV. The instrumental limit of detection (LOD) was 1.4 × 10–7 mol L?1 (0.058 mg L?1) and the dynamic linear range covered three decades (up to 1 × 10–5 mol L?1 or 4.1 mg L?1). The samples were analysed with recoveries about 80% in orange juice samples and from 92.4% to 104.0% in water samples. A study to evaluate potential interferences was made in the presence of other fungicides. Diagnostic studies indicated that oxidation of trifloxystrobin in aqueous medium at the surface of the BDD is irreversible, involving two steps, each one with two electrons. The UV degradation of trifloxystrobin was evaluated using the proposed electrochemical method and the kinetics of degradation established with half-life of 1.07 min.  相似文献   

10.
《Analytical letters》2012,45(12):2171-2185
Abstract

The electrooxidative behavior of citalopram (CTL) in aqueous media was studied by cyclic voltammetry (CV) and square-wave voltammetry (SWV) at a glassy-carbon electrode. The electrochemical behaviour of CTL involves two electrons and two protons in the irreversible and diffusion controlled oxidation of the tertiary amine group. The maximum analytical signal was obtained in a phosphate buffer (pH = 8.2). For analytical purposes, an SWV method and a flow-injection analysis (FIA) system with amperometric detection were developed. The optimised SWV method showed a linear range between 1.10 × 10?5–1.20 × 10?4 mol L?1, with a limit of detection (LOD) of 9.5 × 10?6 mol L?1. Using the FIA method, a linear range between 2.00 × 10?6–9.00 × 10?5 mol L?1 and an LOD of 1.9 × 10?6 mol L?1 were obtained. The validation of both methods revealed good performance characteristics confirming applicability for the quantification of CTL in several pharmaceutical products.  相似文献   

11.
《Analytical letters》2012,45(11):2001-2012
Abstract

A simple, rapid, injection chemiluminescence method is described for the determination of prulifloxacin, a commonly used antibiotic. A strong chemiluminescence signal was detected when a mixture of the analyte and tris-(4,7-diphenyl-1,10-phenanthrolinedisulfonic acid)ruthenium(II) was injected into cerium(IV) sulfate. The chemiluminescence signal is proportional to the concentration of prulifloxacin in the range 4.0 × 10?8–9.0 × 10?6 mol L?1. The detection limit is 1.0 × 10?8 mol L?1, and the relative standard deviation is 2.2% (n = 11) for the determination of 8.0 × 10?7 mol L?1 prulifloxacin. The proposed method was successfully applied to the determination of prulifloxacin in pharmaceutical preparations in capsules, spiked serum, and urine samples.  相似文献   

12.
The preparation of a carbon ceramic electrode modified with SnO2 (CCE/SnO2) using tin dibutyl diacetate as precursor was optimized by a 23 factorial design. The factors analyzed were catalyst (HCl), graphite/organic precursor ratio, and inorganic precursor (dibutyltin diacetate). The statistical treatment of the data showed that only the second-order interaction effect, catalyst × inorganic precursor, was significant at 95% confidence level, for the electrochemical response of the system. The obtained material was characterized by scanning electron microscopy (MEV), X-ray diffraction (XRD), RAMAN spectroscopy, XPS spectra, and voltammetric techniques. From the XPS spectra, it was confirmed the formation of the Si–O–Sn bond by the shift in the binding energy values referred to Sn 3d3/2 due to the interaction of Sn with SiOH species. The incorporation of SnO2 provided an increment of the electrode response for levofloxacin, with Ipa = 147.0 μA for the ECC and Ipa = 228.8 μA for ECC/SnO2, indicating that SnO2 when incorporated into the silica network enhances the electron transfer process. Under the optimized working conditions, the peak current increased linearly with the levofloxacin concentration in the range from 6.21×10?5 to 6.97×10?4 mol L?1 with quantification and detection limits of 3.80×10?5 mol L?1 (14.07 mg L?1) and 1.13×10?5 mol L?1 (4.18 mg L?1), respectively.  相似文献   

13.
刘宁高伟  宋俊峰 《中国化学》2006,24(11):1657-1661
Voltammetry using solid electrodes usually suffers from the contamination due to the deposition of the redox products of analytes on the electrode surface. The contamination has resulted in poor reproducibility and overelaborate operation procedures. The use of the chemical catalysis of oxidant on the reduction product of analyte not only can eliminate the contamination of analyte to solid electrodes but also can improve the faradaic response of analyte. This work introduced both the catalysis of oxidant K2S2O8 and the enhancement of surfactant Triton X-100 on the faraday response of amiodarone into an adsorptive stripping voltammetry at a carbon paste electrode for the determination of amiodarone. The method exhibits high sensitivity, good reproducibility and simple operation procedure. In 0.2 mol·L^-1 HOAc-NaOAc buffer (pH=5.3) containing 2.2×10^-2 mol·L^-1 K2S2O8 and 0.002% Triton X-100, the 2.5th-order derivative stripping peak current of the catalytic wave at 0.3 V (vs. Ag/AgCl) is rectilinear to amiodarone concentration in the range of 2.0×10^-10-2.3×10^-8 mol·L^-1 with a detection limit of 1.5×10^-10 mol·L^-1 after accumulation at 0 V for 30 s.  相似文献   

14.
《Analytical letters》2012,45(11):1797-1807
Fe3O4 magnetic nanoparticles were synthesized by chemical co-precipitation with sodium citrate as a surfactant and were used with chitosan to construct a novel hydrogen peroxide sensor. The electrochemical behavior of hydrogen peroxide at the sensor was investigated by cyclic voltammetry. The composite film electrocatalyzed the reduction of hydrogen peroxide, and the peak current increased linearly with concentration from 1.00 × 10?5 to 1.00 × 10?3 mol · L?1 (R = 0.9974) with a detection limit of 1.53 × 10?6 mol · L?1. This novel nonenzyme sensor provided good sensitivity, stability, and precision with potential applications.  相似文献   

15.
Concentration effect of silver nanoparticles (AgNPs) on the photophysical properties of ciprofloxacin (Cip) have been investigated using optical absorption and fluorescence techniques. When performed AgNPs solution was added to the Cip solution, metal-enhanced fluorescence intensity and a blue-shift of 20 nm in the maximum emission spectra of Cip has been observed. The enhanced intensity of this system is strongly dependent on the AgNPs concentration and largest at the 6.0 × 10?6 mol L?1. With increase of AgNPs concentration, quenching of fluorescence is observed. Stern–Volmer quenching constants have been calculated at four temperatures. The results show the quenching constants are directly correlated with temperature. It indicates the quenching mechanism is the dynamic quenching in nature rather than static quenching. From which we determined the activation energy for the quenching of Cip-AgNPs to be about 31.1 kJ mol?1. In addition, in the presence of optimum AgNPs concentration, a sensitive fluorimetric method for the determination of ciprofloxacin at the range 5.0 × 10?7–3.0 × 10?5 mol L?1 and the detection limit of 2 × 10?8 mol L?1 in solution is proposed.  相似文献   

16.
《Analytical letters》2012,45(5):858-866
A procedure was developed for the determination of polyethylene glycol monoester acrylate (PEGMA) and polyethylene glycol diester acrylate (PEGDA) by reversed-phase high performance liquid chromatographic (RP-HPLC) with UV detector. Sample was well separated on an SinoChrom ODS-BP (C-18) column (200 × 4.6 mm i.d., 5 μm) with mobile phases composed of acetonitrile-phosphate buffer solution (0.05 mol · L?1 pH = 6.86) in the ratio of 42:58 (v/v). The PEGMA and PEGDA were detected by UV detector at 205 nm, and quantitatively analyzed with an external standard of methyl acrylate. For PEGMA, the linear response ranged from 0.40 × 10?5 mol · L?1 to 2.00 × 10?3mol · L?1 (r2 > 0.999), the detection limit was 0.12 × 10?5 mol · L?1, the recovery rate was found to be 93.4%–99.7%. For PEGDA, the linear response ranged from 0.20 × 10?5 mol · L?1 to 1.00 × 10?3mol · L?1 (r2 > 0.999), the detection limit was 0.04 × 10?5 mol · L?1, the recovery rate was found to be 99.1% ~ 105.8%. This quantitative method can also be used in the HPLC analysis of other α,β-unsaturated esters.  相似文献   

17.
《Analytical letters》2012,45(15):2537-2547
A promising nanotechnological material, zirconia nanoparticles modified with SiO2, was used as a medium for the immobilization of laccase to construct a novel biosensor that exhibits sensitive amperometric response to catechol in 0.1 mol · L?1 phosphate buffer (pH 6.0) using cyclic voltammetry. The linear response to catechol was from 1.0 × 10?6 to 1.0 × 10?4 mol · L?1 and the detection limit was 3.5 × 10?7 mol · L?1 at a signal-to-noise ratio of 3. The biosensor exhibited good stability, precision, and few interferences.  相似文献   

18.
《Analytical letters》2012,45(16):2445-2454
A novel voltammetric sensor using multi-wall carbon nanotubes (MWNTs) coupled with Nafion modified glassy carbon electrode (GCE) was developed for the detection of methylparaben (MP). The sensor exhibited good electrocatalytic activity toward the oxidation of MP in the phosphate buffer solution (PBS, pH 6.5). It displayed good sensitivity, repeatability, reproducibility, and long-term stability. Under the optimized conditions, the anodic peak current was linear with the concentration of MP in the range of 3 × 10?6 mol L?1 to 1 × 10?4 mol L?1. The detection limit was 1 × 10?6 mol L?1. The proposed method was successfully applied to determine MP in cosmetics with satisfactory results.  相似文献   

19.
《Analytical letters》2012,45(5):822-836
Abstract

A spectrophotometric method for the determination of vancomycin base, (VCM), and vancomycin hydrochloride, (HVCM), based on the reaction with copper (II) ions, is presented. The obtained detection limit is about 4.5×10?5 mol L?1. The working analytical range falls between 1.0×10?3 mol L?1 and 1.0×10?2 mol L?1. Recovery studies in presence of excipients were performed. The recovery results were compared with HPLC. For HVCM the proposed method presented similar recovery to that of HPLC, 100.4% vs. 100.2%, but better precision, 1.9% vs. 6.1%. In the VCM case the recovery is quite better, 100.5% vs. 89.6%, with a little smaller precision, 2.1% vs. 1.3%.  相似文献   

20.
《Analytical letters》2012,45(13):2091-2104
A carbon composite electrode modified with copper (II) phosphate immobilized in a polyester resin (Cu3(PO4)2-Poly) was proposed for the voltammetric determination of catechin in teas. The modified electrode allows the determination of catechin (CAT) at lower potential than that observed at an unmodified electrode. Several parameters that can influence the voltammetric response of the proposed electrode such as carbon composite composition, pH of electrolyte, and others were investigated. The peak current was proportional to the concentration of catechin in the range from 9.9 × 10?8 to 1.2 × 10?6 mol L?1, with a detection limit of 5.8 × 10?8 mol L?1. The stability and repeatability of the electrode for the determination of catechin were discussed, and the modified electrode was applied with success in the determination of catechin in teas.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号