首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《Analytical letters》2012,45(6):981-993
Abstract

The behaviour of DL-N-acetylhomocysteine thiolactone (citiolone) at a hanging mercury drop electrode is studied by cathodic stripping voltammetry (c.s.v.) as an example for determination of thiolactones. Voltammetric response is only obtained at pH> 9.3, when the cyclic structure of thiolactone is open. A spectrometric study is made in order to ascertain this behaviour. Under the recommended conditions and at pH> 9.3, the sulfur containing group can form mercury complexes and citiolone can be determined from the stripping peak that appears at about -0.470 V within the concentration range 3.5 10?7- 1 10?9 mol l?1. Calibration functions are reported and detection limits calculated. The interference of several organic compounds is reported.  相似文献   

2.
A simple adsorptive cathodic stripping voltammetry method has been developed for antimony (III and V) speciation using 4‐(2‐thiazolylazo) – resorcinol (TAR). The methodology involves controlled preconcentration at pH 5, during which antimony(III) – TAR complex is adsorbed onto a hanging mercury drop electrode followed by measuring the cathodic peak current (Ip,c) at ?0.39 V versus Ag/AgCl electrode. The plot of Ip,c versus antimony(III) concentration was linear in the range 1.35×10?9–9.53×10?8 mol L?1.The LOD and LOQ for Sb(III) were found 4.06×10?10 and 1.35×10?9 mol L?1, respectively. Antimony(V) species after reduction to antimony(III) with Na2SO3 were also determined. Analysis of antimony in environment water samples was applied satisfactorily.  相似文献   

3.
《Electroanalysis》2006,18(12):1202-1207
A new type of current sensor, Langmuir–Blodgett (LB) film of calixarene on the surface of glassy carbon electrode (GCE) was prepared for determination of mercury by anodic stripping voltammetry (ASV). An anodic stripping peak was obtained at 0.15 V (vs. SCE) by scanning the potential from ?0.6 to +0.6 V. Compared with a bare GCE, the LB film coated electrode greatly improves the sensitivity of measuring mercury ion. The fabricated electrode in a 0.1 M H2SO4+0.01 M HCl solution shows a linear voltammetric response in the range of 0.07–40 μg L?1 and detection limit of 0.04 μg L?1 (ca. 2×10?10 M). The high sensitivity, selectivity, and stability of this LB film modified electrode demonstrates its practical application for a simple, rapid and economical determination of Hg2+ in a water sample.  相似文献   

4.
《Analytical letters》2012,45(9):1741-1753
Abstract

An electroanalytical methood, based on derivative chronopotentiometry of the complex of beryllium(II) with 4-[(4-diethylamino-2-hydroxy-phenyl)-azo]-5-hydroxy-naphthalene-2,7-disurphonic acid (Beryllon II) accumulated adsorptively on the surface of a hanging mercury drop electrode, has been developed for determining trace beryllium in food. The dependences of the peak height on the dt/dE vs. E curve on the pre-concentration time, preconcentration potential and the constant reducing current are discussed. In 0.15 mol/1 NHs+0.05 mol/1 NH4Cl, 4×10?7 mol/l Beryllon II, and at a preconcentration potential of -0.30 V (ve. SCE), the limit of detection and linear range are 1 × l0?10 mol/l and 3 × 10?10 -2 × l0?7 mol/l, Iwpectively. The relative standard error of the method is 2.3% for 6 × 10?8 mol/l Be(II). The method WBB applied to samples of food. The electrode procees hae been diecueeed.  相似文献   

5.
《Electroanalysis》2005,17(17):1540-1546
The accumulation voltammetry of mercury(II) was investigated at a carbon paste electrode chemically modified with silica gel functionalized with 2,5‐dimercapto‐1,3,4‐thiadiazole (DTTPSG‐CPE). The repetitive cyclic voltammogram of mercury(II) solution in the potential range ?0.2 to +0.8 V (vs. Ag/AgCl), (0.02 mol L?1 KNO3 ; v=20 mV s?1) show two peaks one at about 0.0 V and other at 0.31 V. However, the cathodic wave peak, around 0.0 V, is irregular and changes its form in each cycle. This peak at about 0.0 V is the reduction current for mercury(II) accumulated in the DTTPSG‐CPE. The anodic wave peak at 0.31 V is well‐defined and does not change during the cycles. The resultant material was characterized by cyclic and differential pulse anodic stripping voltammetry performed with the electrode in differents supporting electrolytes. The mercury response was evaluated with respect to pH, electrode composition, preconcentration time, mercury concentration, “cleaning” solution, possible interferences and other variables. The precision for six determinations (n=6) of 0.05 and 0.20 mg L?1 Hg(II) was 2.8 and 2.2% (relative standard deviation), respectively. The method was satisfactory and used to determine the concentration of mercury(II) in natural waters contaminated by this metal.  相似文献   

6.
A hanging copper amalgam drop electrode (HCADE) is used for the determination of traces of iodide by cathodic stripping voltammetry. The cathodic stripping peak of copper(I) iodide from the HCADE is better defined than that of mercury(I) iodide from a hanging mercury drop electrode. Optimum conditions and interferences are reported. With a 3-min deposition time at ?0.1 V vs. SCE, the calibration plot is linear up to 2 × 10?6 mol dm?3 iodide. The detection limit for iodide with the HCADE under voltammetric conditions is 4 × 10?8 mol dm?3; this is lowered to 8 × 10?9 mol dm?3 by using the differential pulse stripping technique.  相似文献   

7.
The electrochemical behaviour of dacarbazine [5-(3,3-dimethyl-1-triazenyl) imidazole-4-carboxamide; DTIC] was investigated by Tast and differential pulse polarography (d.p.p.) at the dropping mercury electrode, by cyclic and differential pulse voltammetry at the hanging mercury drop electrode and by anodic voltammetry at the glassy carbon electrode. Calibration graphs were obtained for 2×10?8?2×10?5 M DTIC by d.p.p., for 5×10?9?1×10?5 M by adsorptive stripping voltammetry ar a hanging mercury drop electrode, and for 1?10×10?5 M by high-performance liquid chromatography with oxidative amperometric detection at a glassy carbon electrode. The methods are compared and applied to determine DTIC added to blood serum after a simple clean-up procedure.  相似文献   

8.
An electroanalytical method, based on derivative chronopotentiometry of the iron complex with 2-(5′-bromo-2′- pyridylazo)-5-diethylaminophenol (5-Br-PADAP) accumulated adsorptively on the surface of a hanging mercury drop electrode, for determining trace iron in food has been developed. The dependences of the peak height on the dt/dE vs. E curve on the preconcentration time, preconcentration potential and electrode area are discussed. Optimum experimental conditions include 0.005 mol 1?1 NH3NH4Cl, 2 × 10?7 mol 1?1 5-Br-PADAP and a preconcentration potential of ?0.40 V (vs. SCE). Under these conditions, the detection limit and the linear range are 2 × 10?9 and 6.7 × 10?9?1.7 × 10?7 mol 1?1, respectively. The relative standard error of the method is 1.5% for 6.7 × 10?8 mol 1?1 Fe(III). The method was applied to samples of microwave digested food.  相似文献   

9.
《Analytical letters》2012,45(15):2965-2975
ABSTRACT

Albendazole is determined by differential-pulse adsorptive cathodic stripping voltammetry at a hanging mercury drop electrode using the reduction peak of its copper(II) complex at ?0.28V at an accumulation potential 0.0V vs. Ag/AgCl electrode. The optimum conditions of pH, accumulation potential and accumulation time were studied. The calibration graph for the determination of albendazole was linear in the range 3.0X10?8 - 9X10?7M with a relative standard deviation of 2.8%. The detection limit was 1.0X10?8M after 180s accumulation at 0.0V. The effect of common excipients and metal ions on the peak height of albendazole was studied. The presence of Cu2+ ions forms a stable complex with albendazole which is strongly adsorbed at the mercury electrode surface. The method was applied to the determination of the drug in commercially available dosage forms.  相似文献   

10.
The behaviour of 2-mercaptoethanol at a hanging mercury drop electrode by cathodic stripping voltammetry (c.s.v.) is studied. The stripping curves are recorded by three scanning modes: rapid-scan direct-current, differential-pulse and fundamental harmonic alternating-current polarography. Under the recommended conditions, pre-electrolysis is done at a potential of 0.0 V vs. Ag/AgCl for 3 min in a medium of pH 6.7 or 8 (Britton-Robinson buffer). Then after 1 min, stripping is done at a scan rate of 6.6 mV s?1 preferably in the differential-pulse mode. The stripping peak at about ?0.4 V is used to determine 2-mercaptoethanol within the concentration range 3 × 10?8/2-8 × 10?7 mol l?1. Calibration functions are reported; the standard additions method is preferred near the limit of detection. The interferences of several organic compounds are described.  相似文献   

11.
《Analytical letters》2012,45(15):2743-2753
Abstract

The electrochemical behavior of 6-MP was studied by cyclic voltammetry at a hanging copper amalgam dropping electrode (HCADE). It was found that 6-MP could form a complex with the Cu(II) stripped from the HCADE, showing a new peak at ?0.19V in the medium of 0.1mol/L LiClO4-0.5mol/L HClO4 solution. The mechanism of the reaction was proposed. This new peak was sensitive and could be used for the determination of trace 6-MP by differential pulse adsorption cathodic stripping voltammetry (DPAdCSV). The linear range was from 3.6×10?10 to 5.3×10?6 mol/L, and the detection limit was about 1.2×10?10 mol/L (S/N=3). The method was also successfully applied to the determination of 6-MP in pharmaceutical tablets.  相似文献   

12.
《Analytical letters》2012,45(6):1143-1158
Abstract

A sensitive and reliable stripping voltammetry method was developed to determine the presence of Ceftiofur antibiotic drug. This method is based on the adsorptive accumulation of the drug at a hanging mercury drop electrode and then the initiation of a negative sweep that yielded well‐defined cathodic peaks at ?0.65 V (1 C) and ?1.00 V (2 C) vs. Ag/AgCl reference electrode. To achieve high sensitivity, various experimental and instrumental variables were investigated such as supporting electrolyte, pH, accumulation time and potential, drug concentration, scan rate, convection rate, and working electrode area. The monitored adsorptive current of peak 1 C was directly proportional to the concentration of Ceftiofur; it shows a linear response in the range from 0.50×10?8 to 8.00×10?8 mol L?1 (correlation coefficient=0.998); and the limit of detection is 6.00×10?10 mol L?1 at an accumulation time of 300 s. The applicability of this approach was illustrated by the determination of Ceftiofur in pharmaceutical preparations and bovine serum.  相似文献   

13.
In this paper a carbon ionic liquid electrode (CILE) was fabricated by using ionic liquid 1‐ethyl‐3‐methylimidazolium ethylsulphate ([EMIM]EtOSO3) as the modifier and further used as the working electrode for the sensitive anodic stripping voltammetric detection of Pb2+. The characteristics of the CILE were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). In pH 4.5 NaAc‐HAc buffer Pb2+ was accumulated on the surface of CILE due to the extraction effect of IL and reduced at a negative potential (‐1.20 V). Then the reduced Pb was oxidized by differential pulse anodic stripping voltammetry with an obvious stripping peak appeared at ?0.67 V. Under the optimal conditions Pb2+ could be detected in the concentration range from 1.0 × 10?8 mol/L to 1.0 × 10?6 mol/L with the linear regression equation as Ip(μA) = ?0.103 C (μmol/L) + 0.0376 (γ = 0.999) and the detection limit as 3.0 × l0?9 mol/L (3σ). Interferences from other metal ions were investigated and Cd2+ could be simultaneously detected in the mixture solution. The proposed method was further applied to the trace levels of Pb2+ detection in water samples with satisfactory results.  相似文献   

14.
The behaviour of the vanadium(V) complex with 5-Br-PADAP at a mercury electrode was investigated in HOAcNaOAc. The adsorption phenomena were observed by linear-sweep voltammetry. The mechanism of the electrode reaction was found to be the irreversible reduction of the V(V) in the complex adsorbed on the surface of the electrode to the V(IV) complex with 5-Br-PADAP. In 0.02 mol l?1 HOAc-0.012 mol l?1 NaOAc (pH 4.5) and 1 × 10?6 mol l?1 5-Br-PADAP, the detection limits of linear-sweep adsorption voltammetry and 1.5th-order derivative adsorption voltammetry are 5 × 10?10 and 2.5 × 10?11 mol l?1 , respectively. The method was applied to samples of ore (Geological Deposit).  相似文献   

15.
Molybdenum(VI) in seawater is determined by means of potentiostatic adsorption of the 8-quinolinol complex onto a mercury film electrode at ?0.2 V vs. SCE and subsequent reduction of the complex by means of constant-current stripping in 5 M calcium chloride medium with a fully automated stripping analyzer. A single stripping peak at –0.42 V vs. SCE was obtained. The molybdenum(VI) concentration in reference seawater NASS-1, with a certified value of 11.5 ± 1.9 μg 1?1, was found to be 8.9 ± 1.3 μg 1?1 (n = 10).  相似文献   

16.
Reaction of 2-bromo-1,3-bis(bromomethyl)benzene (1) with 1,2,3-triazole and benzotriazole yields 2-bromo-1,3-bis(triazol-1-ylmethyl)benzene (2) and 2-bromo-1,3-bis(benzotriazol-1-ylmethyl)benzene (3), isolated as white solids, air stable at room temperature, and characterized by elemental analysis, mass spectra, IR, and NMR (1H, 13C) spectroscopy. The molecular structure of 3 was determined by single-crystal X-ray diffraction. These ligands were evaluated for determination of ultra-trace concentrations of nickel by adsorptive stripping voltammetry. The method is based on adsorptive accumulation of the Ni(II)-L complex onto a hanging mercury drop electrode, followed by reduction of the adsorbed species by voltammetric scan using square wave modulation. However, only with 2 was a signal observed at ?0.81?V. Under the best experimental conditions (pH 5.5; ligand concentration 0.30?μmol?L?1; adsorptive potential (E ads) ?0.70?V and adsorptive time (t ads) 80 s), the peak current is proportional to the Ni(II) concentration to 15.0?μg?L?1, with a 3 detection limit of 0.2?μg?L?1. The proposed method was validated by determining Ni(II) in certified reference waste water (SPS–WW1) with satisfactory results.  相似文献   

17.
Polarographic (d.c.) measurements showed that complex ions of uranium(VI) with catechol adsorb on the dropping mercury electrode. This effect is used to determine uranium(VI) directly in sea water. Optimal conditions include pH 6.8, 2 × 10?3 M catechol, and a collection potential between ?0.1 and ?0.4 V (vs. Ag/AgCl) at a hanging mercury drop electrode. The cathodic scan is made with the linear-scan or differential-pulse mode (d.p.c.s.v.). The detection limit with the d.p.c.s.v, mode is 3 × 10?10 M after a collection period of 2.5 min. Between pH 6 and 8, the peak height increases with pH and with catechol concentration up to 5 × 10?3 M. There is linear relationship between the collection time and the measured peak height until the drop surface becomes saturated. With a collection period of 3 min, the reduction current increases linearly with the metal concentration up to about 5 × 10?3 M U(VI). The maximum adsorption capacity of the mercury drop is 4.4 × 10?10 mol cm2; each complex ion then occupies 0.38 nm2, equivalent to the size of about one catechol molecule. Interference by high concentrations of Fe(III) is overcome by selectively adsorbing U(VI) at a collection potential near the reduction potential of Fe(III). Organic surfactants reduce the peak height for uranium by up to 75% at unnaturally high concentrations only (4 mg l?1 Triton X-100). Competition by high concentrations of Cu(II) for space on the surface of the drop is eliminated by addition of EDTA.  相似文献   

18.
《Analytical letters》2012,45(8):1411-1423
Abstract

The electrochemical behaviour of the bilirubin in many kinds of supporting electrolytes on a glassy carbon electrode (GCE) and a hanging mercury drop electrode (HMDE) was investigated by means of anodic or cathodic differential pulse voltammetry. The influences of different methods of pre-treatment of the glassy carbon electrode was also discussed. In Na2B4.O7-KH2PO4 buffer solution, the linear range was 2×10?9-1×10?9 mol/l and the detection limit was 3.3×10?9 mol/l by anodic differential pulse voltammetry at GCE. A linear relationship holds between the peak current and the concentration of bilirubin in a concentration range of 1×10?9-4×10?7 mol/l with good precision and accuracy, and the limit of detection was 2×10?10 mol/l, when cathodic differential pulse adsorption voltammetry at HMDE was used.  相似文献   

19.
《Analytical letters》2012,45(7):1128-1143
Abstract

The spectrophotometric behavior of uranium (VI) with L-3-(3, 4-dihydroxy phenyl) alanine (LDOPA) reagent revealed that the uranium can form a ML2 complex with LDOPA in solution. Thus a highly sensitive adsorptive stripping voltammetric protocol for measuring of trace uranium, in which the preconcentration was achieved by adsorption of the uranium-LDOPA complex at hanging mercury drop electrode (HMDE), is described. Optimal conditions were found to be a 0.02 M ammonium buffer (pH 9.5) containing 2.0 × 10?5 M (LDOPA), an accumulation potential of ? 0.1 V (versus Ag/AgCl) and an accumulation time of 120 sec.

The peak current and concentration of uranium accorded with linear relationship in the range of 0.5–300 ng ml?1. The relative standard deviation (at 10 ng ml?1) is 3.6% and the detection limit is 0.27 ng ml?1. The interference of some common ions was studied. Applicability to different real samples is illustrated. The attractive behavior of this reagent holds great promise for routine environmental and industrial monitoring of uranium.  相似文献   

20.
The reduction and reoxidation processes of the Fe(II)/Fe(Hg) system in thiocyanate solutions at stationary mercury electrodes have been investigated by cyclic voltammetric, anodic stripping and controlled potential electrolysis methods. In 0.1 M NaSCN and 0.4 M NaClO4 solution containing 1×10?3M Fe(II), the voltammogram on the first cycle at. 0.05 V s?1 gives two consecutive cathodic peaks near ?1.2 and ?1.39 V with a hysteresis on the reversal, and an anodic wave with two large peaks near ?0.58 and ?0.05 V and two small peaks near ?0.52 and ?0.43 V, respectively. The multicyclic voltammogram under the same conditions in the potential region between 0.00 and ?1.50 V gives a cathodic wave with a principal peak near ?1.02 V and two small peaks near ?0.02 and ?0.53 V, respectively, and an anodic wave with a principal peak near ?0.72 V, three small peaks near ?0.64, ?0.52 and ?0.40 V, and with a shoulder near ?0.05 V, respectively. The variation of the shape of the voltammogram on the second and subsequent runs is due to the formation of S2? and CN? during the process of electroreduction of Fe(II). A mechanism is proposed which involves an initial reduction of Fe(II)?SCN? produced in an activation step at a mercury electrode, followed by the chemical redox reaction of a part of Fe(0)?SCN? in the species giving FeS and CN?, and takes into account the influence of FeS and CN? on the further reduction and reoxidation of iron. Both FeS and CN? stimulate further reduction, and reoxidation of iron. The hysteresis of the cathodic wave on the first cycle arises from the fact that Fe(II) is reduced more easily at the mercury electrode covered with FeS than at a pure mercury electrode.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号