首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel flower like 3D nickel/manganese dioxide (Ni/MnO2) nanocomposite was synthesized by a kind of simple electrochemical method and the formation mechanism of flower like structure was also researched. In addition, morphology and composition of the nanocomposite were characterized by scanning electron microscope (SEM), transmission electron microscopy (TEM), and X‐ray photoelectron spectroscopy (XPS). Then the Ni/MnO2 nanocomposites were applied to fabricate electrochemical non‐enzymatic glucose sensor. The electrochemical investigation for the sensor indicated that it possessed an excellent electrocatalytic property for glucose, and could applied to the quantification of glucose with a linear range from 2.5×10?7 to 3.5×10?3 M, a sensitivity of 1.04 mA mM?1 cm?2, and a detection limit of 1×10?7 M (S/N=3). The proposed sensor also presented attractive features such as interference‐free, and long‐term stability. The present study provided a general platform for the one‐step synthesis of nanomaterials with novel structure and can be extended to other optical, electronic and magnetic nanocompounds.  相似文献   

2.
《Analytical letters》2012,45(16):2993-3001
Abstract

A novel optical sensor (optode) is described for the determination of thiocyanate using methyltrioctylammonium chloride immobilized on triacetylcellulose membrane. The response to thiocyanate is the result of adsorption of [Co(SCN)4]2? on sensing membrane, which caused the colorless membrane to change to blue. This optode can readily be regenerated by using 0.02 mol/l sodium oxalate solution. The linear range of the method was 3.44×10?5 to 8.61×10?4 mol/l of thiocyanate with a limit of detection 1.51×10?5 mol/l. The relative standard deviation for eight replicate measurements of 8.61×10?5 and 4.30×10?4 mol/l of thiocyanate was 3.45 and 1.23%, respectively. The sensor was successfully applied for the determination of thiocyanate in saliva of smokers, nonsmokers and various water samples.  相似文献   

3.
Abstract

Penicillin acylase from E. coli (FC 3.5.1.11) was found to hydrolyse N-phenylacetylated 1-aminoalkylphosphonic acids and their esters. Enzyme preferentially converts the R-form of the substrates: the ratios of the bimolecular rate constants of penicillin acylase-catalysed hydrolysis of R-and S- forms of 1-(N-phenylacetaminol-ethylphosphonic acid and its dimethyl- and diisopropyl- esters are 58000, 2600, 1800; these derivatives were shown to have the greatest values of the catalytic constants for enzymatic hydrolysis of all known substrates of penicillin acylase: 237, 148, and 134 s; corresponding values of Michaelis constants are 3.7×10?5, 6.8×10?4, and 6.2×10?4 M. The kinetics of the enzymatic hydrolysis of 1-(N-phenylacetaminol-ethylphosphonic acid was investigated up to high degrees of conversion. The inhibition of penicillin acylase by high concentrations of the R-form of the substrate (with substrate inhibition constant 0.07 Ml and competitive inhibition by the reaction product phenylacetic acid (Ki=3.5×10?5 M) was observed. Penicillin acylase was shown to possess quite broad substrate specificity among N-acylated 1-aminoalkylphosphonic acids and was found to be capable of hydrolysing 1-(N-phenylacetaminol-substituted 2-phenylethyl-, 1-phenylmethyl- and 3-methylbutylphosphonic acids with high efficiency and enantioselectivity.  相似文献   

4.
《Analytical letters》2012,45(18):3046-3057
Abstract

Nano-MnO2/chitosan composite film modified glassy carbon electrode (MnO2/CHIT/GCE) was fabricated and a DNA probe was immobilized on the electrode surface. The immobilization and hybridization events of DNA were characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The EIS was applied to the label-free detection of the target DNA. The human immunodeficiency virus (HIV) gene fragment was successfully detected by this DNA electrochemical sensor. The dynamic detection range was from 2.0 × 10?11 to 2.0 × 10?6 mol/L, with a detection limit of 1.0 × 10?12 mol/L.  相似文献   

5.
《Analytical letters》2012,45(1):24-35
Abstract

A highly‐sensitive sequence‐selective DNA sensor based on HRP‐labeled probe to detect specific K‐ras gene which is highly associated with colorectal cancer has been reported. Capture probe modified with–SH was first chemically adsorbed on the gold electrode through self‐assembly. Then, the hybridization of a complementary nucleic acid (target DNA:K‐ras gene) and HRP labeled oligonucleotide detection probe occurred in a sandwich way. Finally, H2O2 electroreduction current catalyzed by HRP was measured amperometrically in the presence of hydroquinon as mediator. The sequence selectivity is double guaranteed by the complementary hybridization of target DNA with capture and detection probes. The experimental conditions were optimized. The linear range is 1.17×10?11~1.17×10?7 mol l?1 with a detection limit of 5.85×10?12 mol l?1. The electrode with capture probe can be reused after regeneration in boiling water.  相似文献   

6.
《Analytical letters》2012,45(2):381-392
Abstract

A selective molecular imprinting-chemiluminescence sensor is developed for the determination of prulifloxacin by using a prulifloxacin-imprinted polymer as recognition material and the cerium(IV)/sodium thiosulfate/prulifloxacin chemiluminescence reaction as the detection system. The linear response range of the sensor is from 8.0 × 10?8 to 7.0 × 10?6 mol L?1 with a detection limit of 2.0 × 10?8 mol L?1. The relative standard deviation for 5.0 × 10?7 mol L?1prulifloxacin solution is 1.3% (n = 7). This sensor has been applied to the determination of prulifloxacin in urine samples, and the results obtained are satisfactory.  相似文献   

7.
Tripropylamine (TPA) is a highly toxic and carcinogenic compound, therefore, TPA concentration in water must be monitored to protect health and the environment. In this paper, an electrochemiluminescent (ECL) sensor was fabricated by immobilising Ru(bpy)32+‐modified CuO nanoparticles (NPs) on a TiO2 nanotube array (TN) electrode. Compared to an ECL sensor fabricated by immobilising Ru(bpy)32+ on a TN only electrode, the as‐prepared sensor displays a 30 % enhanced ECL signal and a detection limit of 9.6×10?10 M at a signal‐to‐noise ratio=3 with the concentration of TPA in a range 1×10?9 to 1×10?5 M. The results from this study indicated a new approach for the enhancement of performance of ECL sensor in detecting TPA in water.  相似文献   

8.
《Analytical letters》2012,45(8):1491-1499
ABSTRACT

Glassy Carbon Electrodes coated with stearic acid provide an amperometric sensor for detection of paraquat, the active ingredient of the herbicide Gramoxone. The linear dynamic range of the sensor for Paraquat is 1.02 × 10?3 mol dm?3 to 1.02 × 10?2 mol dm?3 with the minimum detection limit 6.37 × 10?4 mol dm?3.  相似文献   

9.
《Analytical letters》2012,45(5):895-907
Abstract

An amperometric biosensor for the determination of phenols is proposed using a crude extract of sweet potato (Ipomoea batatas (L.) Lam.) as an enzymatic source of polyphenol oxidase (PPO; tyrosinase; catechol oxidase; EC 1.14.18.1). The biosensor is constructed by the immobilization of sweet potato crude extract with glutaraldehyde and bovine serum albumin onto an oxygen membrane. This biosensor provides a linear response for catechol, pyrogallol, phenol and p-cresol in the concentration ranges of 2.0×10?5-4.3×10?4mol L?1, 2.0×10?5-4.3×10?4 mol L?1, 2.0×10?5-4.5×10?4 mol L?1 and 2.0×10?5-4.5×10?4mol L?1, respectively. The response time was about 3–5 min for the useful response range, and the lifetime of this electrode was excellent for fifteen days (over 220 determinations for each enzymatic membrane). Application of this biosensor for the determination of phenols in industrial wastewaters is presented.  相似文献   

10.
《Analytical letters》2012,45(3-4):353-362
Abstract

A bacterial electrode for sulfate was developed by coupling a strain of the bacterium Desulfovibrio desulfuricans with a sulfide selective electrode. This bacterium reduces sulfate to sulfide by a complex multistep enzymatic reaction sequence. The response of this sensor to sulfate is Nernstian in the concentration range of 4 × 10?5 to 7 × 10?4 M. The electrode functions for a period up to 10 days when stored in growth medium under a nitrogen atmosphere. However, it is necessary to keep the sensor in an oxygen-free environment at all times, because oxygen irreversibly inhibits the required enzymes. Although this limits the practical utility of this sensor, alternative configurations for a more practical analytical system are proposed.  相似文献   

11.
A novel electrochemically treated ZrOCl2 doped carbon paste composite electrode was easily prepared by directly incorporating ZrOCl2 into graphite powder after with an electrochemical treatment for the first time. This sensor showed sensitive voltammetric sensing for daidzein. The surface morphology and electrochemical properties of the electrode were investigated by scanning electron microscopy and cyclic voltammetry. The electrochemical behavior of daidzein was investigated in detail. Under the optimized conditions, the response currents were linearly related to daidzein concentrations in the range of 3×10?8 to 2×10?6 mol L?1 with a detection limit of 1×10?8 mol L?1 in phosphate buffer solution with pH 2.5. The proposed sensor was also applied to the determination of daidzein in pueraria, pharmaceutical preparations and human uric sample with satisfactory results.  相似文献   

12.
A new strategy for trace analysis was proposed by preparing a molecularly imprinted polymer (MIP) sensor. The template molecules of clopyralid were determined based on “gate-controlled” electrochemiluminescence (ECL) measurement. A dense polymer film was electropolymerized on an electrode surface to fabricate the MIP–ECL sensor. The process of template elution and rebinding acted as a gate to control the flux of probes, which pass through the cavities and react on the electrode surface. ECL measurement was conducted in the luminol–H2O2 system. A linear relationship between ECL intensity and clopyralid concentrations in the range of 1?×?10?9 mol/L to 8?×?10?7 mol/L exists, and the detection limit was 3.7?×?10?10 mol/L. The prepared sensor was used to detect clopyralid in vegetables. Recoveries of 97.9 % to 102.9 % were obtained. The sensor showed highly selective recognition, high sensitivity, good stability, and reproducibility for clopyralid detection.  相似文献   

13.
The determination of KRAS was performed using electrochemical sensing devices based on graphite and graphene pastes, modified with a phthalocyanine-boron dipyrromethene (BODIPY) and azulenes dyes. The limits of quantification for KRAS were 1.54?×?10?4?µg/mL using the sensor based on the phthalocyanine-BODIPY dye and graphite, 2.64?×?10?7?µg/mL using the sensor based on 2,6-bis((E)-2-(furan-2-yl)vinyl)-4-(4,6,8-trimethylazulen-1-yl)pyridine/TiO2Pt/reduced graphene oxide, and 3.84?×?10?3?µg/mL using the sensor based on 2,6-bis((E)-2-(thiophen-3-yl)vinyl)-4-(4,6,8-trimethylazulen-1-yl)pyridine/TiO2Pt/reduced graphene oxide. Recovery measurements demonstrated the suitable analytical performance of these sensors for the early detection of colon cancer by the analysis of whole blood samples.  相似文献   

14.
《Analytical letters》2012,45(17):3100-3112
Abstract

A novel hemoglobin (Hb) biosensor based on the remarkable synergistic effects of cerium dioxide (CeO2) and multiwalled carbon nanotubes (MWNTs) for detection of hydrogen peroxide (H2O2) is presented. The Hb/CeO2/MWNTs/CHIT nanocomposite was nanoengineered by selected matched material components and optimized composition ratio to produce a superior H2O2 sensor. The preparation method is quite simple and practical. This composite matrix combined the advantages of MWNTs, CeO2 nanoparticles, and chitosan (CHIT), with good electron-transfer ability, attractive biocompatibility, and fine film-forming ability, which could increase Hb attachment quantity and H2O2 detection sensitivity. In the optimum pH 7.0 phosphate buffer, the electrocatalytic response exhibited a linear dependence on H2O2 concentration in a wide range from 5.0 × 10?6 to 4.6 × 10?4 mol L?1 with a detection limit of 6.5 × 10?7 mol/L (3σ).  相似文献   

15.
《Electroanalysis》2006,18(21):2070-2078
A highly selective potentiometric sensor for thiocyanate ion based on the use of a newly synthesized organo‐palladium ion exchanger complex dispersed in a plasticized poly(vinyl chloride) membrane is described. The sensor displays a Nernstian response (?57.8±0.2 mV decade?1) over a wide linear concentration range of thiocyanate (1.0×10?6–1.0×10?1 mol L?1 ), low detection limit (6.3×10?7 mol L?1), fast response (20 s), stable potential readings (±0.4 mV), good reproducibility (±0.9%), long term stability (8 weeks), high precision (±0.7%) and applicability over a wide pH range (4–10). Negligible interferences are caused by F?, Cl?, I?, Br?, NO3?, NO2?, CN?, SO42?, S2O32?, PO43?, citrate, acetate and oxalate ions. Under hydrodynamic mode of operation (FIA), the calibration slope is ?51.1±0.1 mV decade?1, the linear response range is 1.0×10?5–1.0×10?1 mol L?1 SCN? and the sample throughput is 40–45 per hour. The sensor is satisfactory used for manual and flow injection potentiometric determination of SCN? in the saliva and urine of cigarette smokers and non smokers. The data agree fairly well with results obtained by the standard spectrophotometric technique. Direct potentiometry and potentiometric titration of SCN? with Ag+ are also monitored with the sensor.  相似文献   

16.
A biomimetic sensor containing the oxo‐bridged dinuclear manganese‐phenanthroline complex incorporated into a cation‐exchange polymeric film deposited onto glassy carbon electrode for detection of sulfite was studied. Cyclic voltammetry at the modified electrode in universal buffer showed a two electron oxidation/reduction of the couple MnIV(μ‐O)2MnIV/MnIII(μ‐O)2MnIII. The sensor exhibited electrocatalytic property toward sulfite oxidation with a decrease of the overpotential of 450 mV compared with the glassy carbon electrode. A plot of the anodic current versus the sulfite concentration for potential fixed (+0.15 V vs. SCE) at the sensor was linear in the 4.99×10?7 to 2.49×10?6 mol L?1 concentration range and the concentration limit was 1.33×10?7 mol L?1. The mediated mechanism was derived by Michaelis? Menten kinetics. The calculated kinetics values were Michaelis? Menten rate constant= =1.33 µmol L?1, catalytic rate constant=6.06×10?3 s?1 and heterogeneous electro‐chemical rate constant=3.61×10?5 cm s?1.  相似文献   

17.
Responses of organic fluorophore, perylenediimide derivative N,N′-di[3-[2-(3-thienyl)ethyl]phenyl]perylene-3,4,9,10-bis-(dicarboxyimide) (PDI1) was investigated in polymer matrix of polyvinyl chloride (PVC) by emission spectrometry. Its response to Fe(III) ions was evaluated in terms of the effect of pH. The properties of time dependent response, reversibility, limit of detection, linear concentration range for the metal ion and repeatability characteristics of the sensing element also have been studied. The offered sensor exhibited remarkable fluorescence intensity quenching at pH 6.0 in the concentration range of 1 × 10?6 to 2.5 × 10?3 M Fe(III) ions. The reproducibility of the sensor membrane was investigated by alternately changing the solution between 1 × 10?4 M Fe(III) in Na2HPO4 (4 × 10?2 M) and NaH2PO4 buffer (2 × 10?3 M).  相似文献   

18.
《Analytical letters》2012,45(16):2972-2984
Abstract

The first asymmetric potentiometric Gd(III) microsensor is reported here. N-(2-Pyridyl)-N′-(4-nitrophenyl)thiourea (PyTu4NO2) was found to have a very selective and sensitive behavior toward Gd(III) ions, in comparison to other lanthanide ions as well as inner transition and representative metal ions and hence was used as a sensing material in the construction of a Gd(III) microelectrode. The Gd(III) sensor exhibits a Nernstian slope of 17.46 ± 0.3 mV per decade over the concentration range of 1.0 × 10?8 to 1.0 × 10?3 M and a detection limit of 3.0 × 10?9 M of Gd(III) ions. The potentiometric response of the sensor is independent of the solution pH in the range of 4.0–9.0. It manifests advantages of low detection limit and fast response time (10–15 s).  相似文献   

19.
《Analytical letters》2012,45(8):1556-1568
Abstract

A reagentless H2O2 sensor based on the direct electron transfer of myoglobin (Mb) doped in multiwalled carbon nanotubes enhanced grafted collagen matrix is proposed. The formal potential of the immobilized Mb was ?0.358 V with a surface coverage of 4.0×10?10 mol cm?2. The electrode process was surface‐controlled with an electron transfer rate constant of 9.7 s?1. The proposed biosensor displayed an excellent electrocatalytic response to the reduction of H2O2 with a linear range from 0.6 to 39.0 µM. Owing to the good biocompatibility and high enzyme loading of the matrix the biosensor exhibited acceptable stability and reproducibility.  相似文献   

20.
A new electrochemical sensor based on Fe3O4@SiO2‐PANI‐Au nanocomposite was fabricated for modification of glassy carbon electrode (Fe3O4@SiO2‐PANI‐Au GCE). The Fe3O4@SiO2‐PANI‐Au nanocomposite was characterized by TEM, FESEM‐EDS‐Mapping, XRD, and TGA methods. The Fe3O4@SiO2‐PANI‐Au GC electrode exhibited an acceptable sensitivity, fast electrochemical response, and good selectivity for determination of quercetin. Under optimal conditions, the linear range for quercetin concentrations using this sensor was 1.0×10?8 to 1.5×10?5 mol L?1, and the limit of detection was 3.8×10?9 mol L?1. The results illustrated that the offered sensor could be a possible alternative for the measurement of quercetin in food samples and biological fluids.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号