首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Polychlorinated naphthalenes (PCNs) are candidates for inclusion in the Stockholm Convention on persistent organic pollutants. PCNs are structurally and toxicologically similar to 2,3,7,8-tetrachlorodibenzo-p-dioxin (2,3,7,8-TCDD) and its analogues. Intake in food is considered to be an important human exposure pathway for PCNs. In this preliminary study, cheese and butter samples were analysed for PCNs, polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polychlorinated biphenyls (PCBs) using an isotope dilution gas chromatography high-resolution mass spectrometry method. The aim of this study was to evaluate the PCN concentrations in the cheese and butter samples and to compare them with the PCDD, PCDF and PCB concentrations. The PCN concentrations were 5.6–103 pg g?1 of wet weight in the seven cheese samples tested and 5.0–199 pg g?1 of wet weight in the seven butter samples tested. The mass concentrations of lower chlorinated congeners were greater than those of the higher chlorinated congeners. Congeners of CN45/36, CN27/30 and CN33/34/37 were much more abundant than other congeners found in tetrachlorinated PCNs. Congeners of CN51, CN66/67 and CN73 were determined to be the predominant congeners in penta-, hexa- and heptachlorinated homologs, respectively. The PCNs contributed around 5% of the total PCN, PCDD, PCDF and PCB toxic equivalence (TEQ) values. CN73 was found to be the dominant PCN congener and contributed more than 40% to the PCN TEQ value. Congeners CN66/67, CN69 and CN63 were also found at relatively high levels. The PCB congener CB118 was the predominant congener (by mass-based concentration) of the 12 dioxin-like PCBs (dl-PCBs). The PCBs contributed 53.8% of the total TEQ, and congener CB126 contributed more than any other compound that was analysed to the total TEQ. The PCDDs and PCDFs contributed 11.6% and 29.7% of the total TEQ values, respectively.  相似文献   

2.
13C-labeled compounds are often employed as surrogate or internal standards to monitor the performance of extraction and instrumental analysis procedures for their unlabeled counterparts. However, labeled and unlabeled counterparts most often coelute chromatographically with overlapping mass ion fragments, posing a challenge to the accurate quantification of these compounds. In the present study, an analytical scheme, using coeluting unlabeled and 13C-labeled polychlorinated biphenyl (PCB) congeners as the model compounds, was developed with a low-resolution tandem mass spectrometer (MS/MS) to determine the appropriate ranges of PCB congener concentrations that satisfy the no-interference condition. Interferences from unlabeled PCBs to quantitation of labeled counterparts could be minimized when 13C-labeled PCB congeners were quantified in the MS/MS mode within a certain concentration range. In addition, good agreements between the measured and theoretically predicted quantitation errors were observed for all labeled PCB congeners except PCB 180. The exception with labeled PCB 180 was mainly attributed to the occurrence of instrumental analytical uncertainty, as analytical error was also observed with absence of unlabeled PCB 180. These results indicate that MS/MS techniques can serve as a useful tool to minimize interferences with quantitation of isotopically labeled compounds from their unlabeled counterparts, which possess partially overlapping ion fragment profiles.  相似文献   

3.
The orthogonality of three columns coupled in two series was studied for the congener specific comprehensive two-dimensional GC separation of polychlorinated biphenyls (PCBs). A non-polar capillary column coated with poly(5%-phenyl–95%-methyl)siloxane was used as the first (1D) column in both series. A polar capillary column coated with 70% cyanopropyl-polysilphenylene-siloxane or a capillary column coated with the ionic liquid 1,12-di(tripropylphosphonium)dodecane bis(trifluoromethane-sulfonyl)imide were used as the second (2D) columns. Nine multi-congener standard PCB solutions containing subsets of all native 209 PCBs, a mixture of 209 PCBs as well as Aroclor 1242 and 1260 formulations were used to study the orthogonality of both column series. Retention times of the corresponding PCB congeners on 1D and 2D columns were used to construct retention time dependences (apex plots) for assessing orthogonality of both columns coupled in series. For a visual assessment of the peak density of PCBs congeners on a retention plane, 2D images were compared. The degree of orthogonality of both column series was, along the visual assessment of distribution of PCBs on the retention plane, evaluated also by Pearson's correlation coefficient, which was found by correlation of retention times tR,i,2D and tR,i,1D of corresponding PCB congeners on both column series. It was demonstrated that the apolar + ionic liquid column series is almost orthogonal both for the 2D separation of PCBs present in Aroclor 1242 and 1260 formulations as well as for the separation of all of 209 PCBs. All toxic, dioxin-like PCBs, with the exception of PCB 118 that overlaps with PCB 106, were resolved by the apolar/ionic liquid series while on the apolar/polar column series three toxic PCBs overlapped (105 + 127, 81 + 148 and 118 + 106).  相似文献   

4.
Kanechlor (KC)-300, 400, 500 and 600, Japanese polychlorinated biphenyl (PCB) products, and their equivalent mixture were analyzed by using a gas chromatograph (GC) equipped with an SE-54 capillary column/electron capture detector (ECD) and a GC/mass spectrometer in the selected ion monitoring mode (MS-SIM). All peaks were assigned to the composing congeners based on the data on peak assignment of Clophen A-30, 40, 50, 60 and Aroclor 1016, 1242, 1254, 1260 [1] and on the relative retention time values of 209 PCB congeners [2]. The weight percentage of the congener(s) which corresponds to each peak in the mass chromatograms was calculated by comparison of its height with that of certified reference standard with the same molecular weight. Each weight percentage of PCB congener(s) corresponding to each ECD peak was obtained by summing up the percent contribution values of the PCB congeners co-eluting. The results showed that it was possible to use KC products and their equivalent mixture as secondary reference standards for congener-specific PCB quantification.  相似文献   

5.
Adsorption of 10 PCB congeners in aqueous solutions on glass-fibre filters taken from different boxes but of the same type were not significantly different. The standard deviations using filters from the same box were below 10% at concentration levels of 4.1?ng?L?1. At this level, the adsorption of dissolved PCB at the filters was in the range of 5–20% depending on the congener. This led to a procedure for determination of dissolved and particle-bound congener in authentic landfill leachate, which included correction for adsorption losses. The procedure was based on filtration through glass-fibre filters, followed by trapping of the PCB in the eluate on solid-phase extraction (SPE) disks. After separate supercritical fluid (SFE) extractions, with carbon dioxide, of the filters as well as of the SPE disks, the extracts were analysed on a two-column capillary GC-ECD system. Corrections for congener adsorption on glass-fibre filters were made, from which corrected distribution constants between particle-bound and dissolved PCB congener in the water phase could be obtained for authentic landfill leachate. These values (104–105) agreed well with those obtained by others.  相似文献   

6.
Complete PCB congener distributions in a panel of Aroclor mixtures were previously obtained by combining data from several HRGC systems. In that study quantitation of minor components may have been unreliable due to single level calibration against high levels of individual congener standards. Two lots of Aroclor 1254 had markedly different congener distributions. In this study, the design and performance of a congener-specific PCB analysis method employing GC-MS-SIM detection of congeners separated on a DB-XLB capillary column are discussed. Quantitation is carried out against a 6-level inclusive standard curve of a mixture of 144 congeners found in Aroclors. A separate procedure to measure trace levels of PCB 126 in Aroclors using the same system, combined with levels initially acquired for other congeners, facilitates estimation of TEQ values (Toxic Equivalencies of the PCB mixtures to 2,3,7,8-TCDD). PCB congener profiles of 15 Aroclor 1254 mixtures are presented. These profiles show that the less common, high TEQ variety of Aroclor 1254 was manufactured by an atypical, two-stage chlorination process that was apparently used during the final 1% of Aroclor 1254 production (ca. 1974–1976).  相似文献   

7.
Abstract

Four bacterial isolates belonging to the genera Pseudomonas and Alcaligenes were obtained by the enrichment method, using biphenyl as the sole carbon source, from the soil, which underwent long-time contamination with technical mixtures of PCB. Kinetics of PCB degradation by individual isolates was measured using n-hexane extraction of the cultivation media in proper time intervals and analysed by congener specific gas chromatography with electron capture detection. All isolates exhibit interesting biodegradative potential. Specific degradation of individual congeners with respect to the number and position of chlorine substituents is discussed. The influence of glucose, biphenyl and 3-chlorobenzoic acid on the PCB degradation has been assessed.  相似文献   

8.
Abstract

The anaerobic degradation of PCB in loamy and clayey soils containing indigeneous microflora was studied. The anaerobic conditions were created by an argon atmosphere in the flasks containing soil flooded by a liquid medium with glucose. GC-ECD analysis of soil extracts after 40 day incubation showed, in addition to the concentration changes of the less chlorinated PCB congeners, a significant decrease in the concentration of highly chlorinated congeners in both soils. The results indicate that in both soil types reductive dehalogenation of PCB congeners was encountered.  相似文献   

9.
Summary 6 Non-o,o'-Cl and 20 mono-o,o'-Cl substituted PCB congeners were identified in Main fish by GC-MS. For risk and hazard assessment the concentrations of these PCB's congeners were transformed into the corresponding TCDD equivalents (TE). It was found that the concentrations of the analysed coplanar PCB congeners in fish expressed in TE are by a factor of about 300 higher than those of the polychlorinated dibenzo-p-dioxins (PCDD's) and polychlorinated dibenzofuranes (PCDF's) in fish. Therefore, more attention must be directed towards the analysis of PCB's.Part III: see [2]  相似文献   

10.
A total of 196 out of 209 polychlorobiphenyl (PCB) congeners were resolved using GC×GC-TOFMS with a non-polar/ionic liquid column series consisting of poly(50%-n-octyl-50%-methyl)siloxane and (1,12-di(tripropylphosphonium)dodecane bis(trifluoromethansulfonyl)amide) in the first and second dimension, respectively. It has been found that 13 PCB congeners overlap in five doublets (CB12+CB13, CB62+CB75, CB70+CB76, CB97+CB125 and CB153+CB168) and one triplet (CB90+CB101+CB113). All toxic, "dioxin like" congeners were separated with no interferences from any PCB congener. The 109 PCBs present in Aroclor 1242 and the 82 PCBs present in Aroclor 1260 were resolved GC×GC-TOFMS analysis on this column set.  相似文献   

11.
Abstract

Polychlorinated biphenyls (PCBs) are toxic, perssstent, global environmental contaminants which were formulated as complex mixtures of congeners. Many methods have been developed in the past to analyze PCB in transformer oil samples for regulatory purposes. The most important consideration in the cleanup procedure is the ability to remove the oil from the sample matrix, since trace amount of oil will interfere with the subsequent GC-MS analysis. Electron capture detection (ECD) has been the most common method for gas chromatographic analysis of PCBs because of its high sensitivity toward halogenated compounds. ECD can also respond to some non-PCB compound resulting in biased concentrations of PCB. In this work, a two-stage cleanup method, using DMSO liquid/liquid extraction and HPLC column chromatography. has been applied to two types of transformer oil. Five internal standards have been selected to show their performance in the presence of different oil matrices. The comparison of the PCB quantification at different conditions for GC-MS and GC-ECD will be demonstrated.  相似文献   

12.
A simple dual-column gas chromatographic system with a six-port switching valve has been used to separate the atropisomers of PCB congeners 84, 91, and 95 in technical PCB formulations and in extracts of soil and river sediment. A capillary column coated with a methylphenylsiloxane stationary phase (CP-Sil 8) was used as the first column, for retention window selection, and a permethylated β-cyclodextrin (ChirasilDex) capillary column as the main separation column. Because peak overlap could not be eliminated by optimization of column temperature, the enantiomeric ratios of PCB congeners could not be determined from the original chromatograms. The correct enantiomer ratio was determined from the peak areas obtained by deconvolution of the chromatograms. Whereas the PCB atropisomers considered were present in equal concentrations in the technical PCB formulations, analysis of a river sediment sample confirmed different residual concentrations of the atropisomers of congener 95.  相似文献   

13.
14.
Abstract

The bioaccumulation of PCBs has been studied for 60 Brown trout in Lake Geneva (Switzerland). The contamination level (1–3 ppm in wet weight, 10–30 ppm in lipid weight) is rather high.

Bioaccumulation curves (concentration as a function of the weight of the fish) have been established for 6 congeners and total PCBs. The total concentration of PCBs in wet weight increased with the weight of the fish; highly-chlorinated congeners (I.U.P.A.C. nr. 180, 2,3,4,5,2′,4′,5′-heptachlorobiphenyl) presented a faster, and lightly-chlorinated (I.U.P.A.C. nr. 28, 2,4,4′-trichlorobiphenyl) a slower, bioaccumulation tendency.

The total concentration of PCBs in lipid weight was constant, the concentration of congener 28 increasing and of congener 180 decreasing with the weight of the fish. This is attributed to the antagonistic effects of “growth and lipid dilution” and of the decrease of elimination kinetics as a function of the weight (and age) of the fish.

The partitioning theory and the pharmacokinetic approach are complementary methods for analysing this field data.  相似文献   

15.
Results from polychlorinated biphenyls (PCB) analyses of mussel tissue extracts by immunoassay (PCB RaPID Assay®) and conventional gas chromatography-electron-capture detection (GC-ECD) are described and compared. Mussels from natural populations with diverse concentrations of PCBs, mussel tissue fortified with technical Aroclor® 1254 and a certified reference material are included.A strong correlation is reported between “total” PCBs quantified by both techniques (r2=0.95, n=27). Immunoassay results, however, exhibited lower values compared to GC-ECD, particularly when GC results are corrected for procedural recovery. A reduced antibody response, due to differences in the congener composition between the mussel extracts and Aroclor® 1254 (used to raise and calibrate the ELISA), provides the most likely explanation for this difference. Non-parametric statistical analyses confirmed that, although differing from Aroclor® 1254, PCB congener compositions in the mussel extracts most closely resemble that of Aroclor® 1254. At very high PCB concentrations (>30 μg g−1 dry weight), however, ELISA results are statistically different (P<0.01) from GC-ECD results, which is likely to be related to the solvation capacity of ELISA diluent. Similarity analysis showed high correlations between the most prominent congeners in Aroclor® 1254 and immunoassay results. This analysis did not, however, identify a specific chlorine substitution pattern to which the immunoassay preferentially responded.Whilst GC-ECD affords the capability to quantify individual congeners of different reactivity and toxicity, the data reported do indicate that immunoassay offers a rapid and inexpensive alternative method for estimation of “total” PCBs at environmentally significant levels. It is, however, necessary to remove extraneous lipids to reduce matrix effects in the immunoassay.  相似文献   

16.
Three HRGC systems (1: 30m DB-XLB capillary with MS-SIM detection; 2: 60m DB-XLB capillary with full-scan, ion-trap MS detection; and 3: Parallel dual-column DB-17 and series-coupled HP5/HT5 with ECD detection) were used to completely characterize multiple lots of 8 different-numbered Aroclor mixtures by quantitative calibration against 9 solutions containing primary standards of all 209 PCB congeners. Despite lower absolute sensitivity and more Aroclor congener coelutions than the dual-column ECD system, the MS systems enabled measurement of more congeners per Aroclor since their greater linear response range did not require dilution of samples and standards. Pairs of different lots of Aroclors 1248 and 1254 displayed markedly different proportions of congeners, and the 1254 pair displayed strong differences in the extent of ortho-chlorine substitution. The tables of congener weight percent distributions among Aroclors are more comprehensive and quantitatively precise than those of prior publications. However, the limitations of single-level calibration precluded measurement of all congeners to the ±10% accuracy desirable for establishing these Aroclors as secondary standards for comprehensive, quantitative congener-specific PCB analysis.  相似文献   

17.
Human exposure to polychlorobiphenyls (PCBs) in humans was determined by analyzing adipose tissue samples collected in 1996–1997 from two different localities: Siena (Italy) and Concepción (Chile). ΣPCBs was higher in Italian samples than that from Chile (493 and 53 ng/g wet wt., respectively). Thirty-seven different PCB congeners were identified in all samples. The prevailing PCB congeners in both groups were 22′44′5 pentachlorobiphenyl (IUPAC no. PCB 118), 22′344′5′ (PCB-138) and 22′44′55′ (PCB-153) hexachlorobiphenyls and 22′33′44′5 (PCB-170), 22′344′55′ (PCB-180) and 22′34′55′6 (PCB-187) heptachlorobiphenyls. PCB-153 accounted for more than 20% of the total PCB residue in both groups, while the remaining six congeners accounted for approximately 70%. Hexachlorobiphenyls were the most abundant congeners in all samples, with 42% of total residue in those from Italy and 43% in the Chilean samples, followed by heptachlorobiphenyls with 41 and 36% in Italian and Chilean samples, respectively. Average concentrations of non-ortho substituted coplanar congeners were below 1 pg/g wet wt. In the samples from Siena no noticeable differences were observed between the three average coplanar concentrations, while in those from Concepción 33′44′tetrachlorobiphenyl (PCB-77) was much higher than 33′44′pentachlorobiphenyl (PCB-126) and 33′44′55′hexachlorobiphenyl (PCB-169). For each sample the contribution to the total toxic equivalent values (ΣTEQs) of each non-ortho, mono-ortho and di-ortho substituted PCB congeners was assessed. The overall TEQs calculated for the monitored PCBs, were 10.16 pg/g wet wt. in Italian samples and 1.09 pg/g wet wt. in Chileans ones. In both groups the main contribution to ΣTEQs were the di-ortho substituted PCB congeners (Siena: 6.17 pg/g wet wt.; Concepción: 0.56 pg/g wet wt.) and the mono-ortho substituted PCB congeners (Siena: 3.97 pg/g wet wt.; Concepción: 0.50 pg/g wet wt.).  相似文献   

18.
Levels and patterns of polychlorinated biphenyls (PCBs) were studied in surface soil samples collected in the coastal part of Croatia within and surrounding four different airports and in the vicinity of two partially devastated electrical transformer stations. The compounds accumulated from air-dried soil samples by multiple ultrasonic extraction with an n-hexane?:?acetone 1?:?1 mixture were analysed by capillary gas chromatography with electron capture and ion-trap detection. PCBs were quantified against a standard Aroclor 1242/Aroclor 1260 mixture and a standard mixture of 17 individual PCB congeners (IUPAC No.: 28, 52, 60, 74, 101, 105, 114, 118, 123, 138, 153, 156, 157, 167, 170, 180, and 189). The mass fractions of total PCBs in 18 soil samples collected within the airport premises ranged from 3 to 41?327?µg/kg dry weight (dw) (median: 533?µg/kg?dw), and those in 21 samples collected at a distance ranging from several metres to 5?km away from the airport fence, from <1 to 39?µg/kg?dw (median: 5?µg/kg?dw). The highest PCB levels were determined in soils along the airport aprons where the aircrafts were serviced and refuelled. The PCB pattern was very similar to technical Aroclor 1260 in all airport soils. The PCB pattern in 22 soils collected in the vicinity of electrical transformer stations was dominated by congeners contained in Aroclor 1242. These soils contained 7 to >400?µg/kg?dw of total PCBs. One highly PCB-contaminated airport soil sample was analysed for polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). With an international toxic equivalent (I-TEQ) of 9.7?ng/kg?dw, the airport soil contamination was within values typical for urban and rural areas, and the congener patterns gave no clear indication for PCBs as the only source of PCDDs/PCDFs.  相似文献   

19.
Abstract

Sample analysis from a variety of matrices was performed using Gas Chromatography-Mass Spectrometry (GC-MS). Average relative response factors were calculated for each polychlorinated biphenyl homologue (tri-to deca-chlorobiphenyl) using in-house calibration standard solutions. Sample quantitation using RRFs provided homologue specific results. A series of software macros were used to automate the interpretation of spectral data and the selection of possible PCB congener peaks.  相似文献   

20.
The effects and regulatory actions of the polychlorinated biphenyls (PCBs) substituent characteristics on their relative retention times (RRTs) during gas chromatography were analyzed based on known experimental RRTs of 209 PCB congeners and biphenyl; the substituent characteristics used for this analysis included the total amount of substituents, the similarity between two phenyl rings in a single PCB congener, the substituents distribution in single phenyl ring, the main/second‐order interactions effects at each position, and the combined effect of two phenyl rings. At last, the universality of regulation was validated on other experimental conditions. Among them, the full factorial experimental design included 10 factors correlated with each substituent position and two levels (0, 1) were initially applied to the domains of the substituent characteristics. The obtained results have revealed that increasing the total amount of substituents can increase the RRTs of PCBs linearly, but similarities between the two rings cannot control the RRTs effectively. Meanwhile, the more compact the substituent distributions on a single phenyl ring are, the bigger the RRTs of PCBs are. Based on a full factorial experimental design, the overall important trend for each position is as follows: para > meta > ortho and the main regulatory substituents for the second‐order interaction effects are distributed in the same phenyl ring in the following sequence: No > Nm > Np. The congener with two perpendicular phenyl rings exhibits a milder combined effect on RRTs and smaller RRT relatively. The regulation has a good universality among different experimental conditions, revealing the dominant effect of substituent characteristics on RRTs of PCBs. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号