首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
《Analytical letters》2012,45(5):766-782
A combined homogeneous assay and colorimetric determination method using gold nanoparticles was developed for rapid determination of lead(II) in contaminated natural waters. The presence of lead(II) in the colloidal gold suspension causes a change in the absorbance of the suspension. An increase in the absorption property at 595 nm is accompanied by a change in the size of the gold nanoparticles. High concentrations of lead cause aggregation of the gold colloids. Colloidal gold nanoparticles were synthesized using tannic acid as the reducing agent; this reagent allowed selective determination of lead in 10 µL of water, with a detection limit of 310 ng mL?1 with an analysis time of 5 min. The coefficient of variation for lead(II) within the working range of the assay (520 ng mL?1–13 µg mL?1) varied from 1.3% to 9.2%. The limit of detection using this method with a sample volume of 50 µL was 60 ng mL?1. The coefficient of variation for lead over the working range of the determined concentrations (80 ng mL?1–25 µg mL?1) varied from 0.2% to 9.3%, while the values for the inter-day assay (n = 8) were less than 10%. The method was employed for the analysis of river, lake, marsh, and spring water; the recovery of lead was determined to be 72.5%–130% for 10 µL of water and 93.6%–114.7% for 50 µL.  相似文献   

2.
《Analytical letters》2012,45(2):286-298
Based on the available rabbit monoclonal antibody (RabMAb), a rapid and sensitive lateral flow immunoassay (LFA) platform has been developed for quantitative detection of four sulfonamide residues(SRs) of sulfadiazine (SD), sulfathiazole (STZ), sulfapyridine (SP), and sulfamethoxazole (SMX).Within the designed LFA competitive format assay, which was based on antigen-antibody properties, the hapten conjugate N1-[4-(carboxymethyl)-2-thiazolyl] sulfanilamide linked to protein ovalbumin (TS-OVA) and goat anti-rabbit antibody were sprayed as capture and control reagents, respectively, and then the antibody was conjugated to colloidal gold particles as the detection reagent. With quantitative assessment aided by a colorimetric strip reader, the sensitivities of the established LFA method for SD, STZ, SP, and SMX were 0.91 ng mL?1, 0.10ng mL?1,0.12ng mL?1, and 2.13ng mL?1, and the half-maximum inhibition concentrations (IC50) were 5.19 ng mL?1, 1.25 ng mL?1, 0.66 ng mL?1, and 24.14 ng mL?1, respectively. The recoveries at three spiked levels (5, 20, 50 ng mL?1for SD, STZ, and SP; 20, 50, 100 ng mL?1 for SMX) were in the range of 78.02–135.10% and 76.40–137.16% for milk and swine urine, respectively. More importantly, the detection performance of the established platform was consistent with that of in-parallel LC-MS/MS analysis. In conclusion, the proposed LFA platform has showed the potential for fast, sensitive and relatively accurate quantification of four sulfonamide residues in practical uses.  相似文献   

3.
A simple, sensitive, and precise high performance liquid chromatographic method for the analysis of pantoprazole, rabeprazole, esomeprazole, domperidone and itopride, with ultraviolet detection at 210 nm, has been developed, validated, and used for the determination of compounds in commercial pharmaceutical products. The compounds were well separated on a Hypersil BDS C18 reversed-phase column by use of a mobile phase consisting of 0.05 M, 4.70 pH, potassium dihydrogen phosphate buffer - acetonitrile (720:280 v/v) at a flow rate of 1.0 mL min?1. The linearity ranges were 400–4,000 ng mL?1 for pantoprazole, 200–2,000 ng mL?1 for rabeprazole, 400–4,000 ng mL?1 for esomeprazole, 300–3,000 ng mL?1 for domperidone and 500–5,000 ng mL?1 for itopride. Limits of detection (LOD) obtained were: pantoprazole 147.51 ng mL?1, rabeprazole 65.65 ng mL?1, esomeprazole 131.27 ng mL?1, domperidone 98.33 ng mL?1 and itopride 162.35 ng mL?1. The study showed that reversed-phase liquid chromatography is sensitive and selective for the determination of pantoprazole, rabeprazole, esomeprazole, domperidone and itopride using single mobile phase.  相似文献   

4.
A new facile, rapid, inexpensive, and sensitive method based on magnetic micro-solid phase extraction (M-??-SPE) coupled to gas chromatography?Cmass spectrometry (GC?CMS) was developed for determination of the herbicide oxadiargyl in environmental water samples. The feasibility of employing non-modified magnetic nanoparticles (MNPs) as sorbent was examined and applied to perform the extraction process. Influential parameters affecting the extraction efficiency along with desorption conditions were investigated and optimized. The limit of detection (LOD, S/N = 3) and limit of quantification (LOQ, S/N = 10) of the method under optimized conditions were 0.005 and 0.030 ng mL?1, respectively. The relative standard deviations (RSD) (n = 3) at a concentration of 0.10 ng mL?1 was 11%. The calibration curve of oxadiargyl showed linearity in the range of 0.050?C0.50 ng mL?1. The developed method was successfully applied to the extraction of oxadiargyl from spiked tap water and Zayande-Rood River water samples and the relative recoveries of 98 and 94% were obtained, respectively.  相似文献   

5.
《Analytical letters》2012,45(1):46-55
Abstract

A Chemiluminescence Enzyme‐Linked Immuno‐Sorbent Assay (CL‐ELISA) for determination and quantification of the fungicide thiram in honeybees was developed in an indirect competitive format. The assay was optimized by determining: the optimal coating conjugate concentration and anti‐thiram antiserum dilution, the effect of the incubation time on the competitive step, the tolerance to organic solvents. The IC50 and the limit of detection (LOD) values were 60 ng mL?1 and 9 ng mL?1, respectively, similar to those of colorimetric ELISA with a calibration range of 9–15,000 ng mL?1. Cross reactivity of some related compounds such as some dithiocarbamates, a thiocarbamate, the ethylenethiourea and the tetramethylthiourea were tested. The assay was then applied to honeybees sample extracts obtained by using the liquid‐liquid extraction or the graphitized carbon‐based solid phase extraction.

The calibration curves in honeybee extracts from liquid‐liquid procedure gave an IC50 of 141 ng mL?1 and a LOD of 17 ng mL?1. In case of extracts obtained by SPE these values were 139 ng mL?1 and 15 ng mL?1, respectively. The average recovery value from honeybee extracts spiked with 75 ng mL?1 of thiram was 72% for SPE, higher than for liquid‐liquid extraction (60%). On the opposite, when the honeybees were directly spiked with 2 and 10 ppm the average recovery was higher for liquid‐liquid extraction (54%), than for SPE (31%). Finally, the assay was applied to honeybee samples collected during monitoring activities in Italy and Russia.  相似文献   

6.
《Analytical letters》2012,45(3):466-475
A Chemiluminescent Enzyme-Linked Immuno-Sorbent Assay (CL-ELISA) for determination and quantification of the fungicide imidacloprid in honeybees was developed in an indirect competitive format. The assay was optimized by determining: the optimal coating conjugate concentration and anti-imidacloprid antiserum dilution, the effect of the incubation time on the competitive step, and the tolerance to organic solvents. The IC50 and the limit of detection (LOD) values were 14.8 ng mL?1 and 0.11 ng mL?1, respectively, similar to those of colorimetric ELISA with a calibration range of 0.1–2600 ng mL?1. Cross reactivity of some related compounds such as three imidacloprid metabolites, 6-chloro nicotinic acid, 5-hydroxy-imidacloprid, and imidacloprid olefin, and one other chloronicotinoid insecticide, acetamiprid, were tested. The assay was then applied to honeybee extracts obtained by using the liquid-liquid extraction. The calibration curves in honeybee extracts from the liquid-liquid procedure gave an IC50 of 23.7 ng mL?1 and a LOD 1.6 ng mL?1. The average recovery value from honeybee extracts spiked with 100 and 1000 ng mL?1 of imidacloprid were 73% and 76%, respectively. Finally, the assay was applied to honeybee samples collected during monitoring activities in Italy; it was found that only five of the 27 samples were positives, with low concentrations of imidacloprid ranging between 1.2 and 15.4 ng g?1.  相似文献   

7.
A new method has been developed for the determination of metalaxyl, myclobutanil, and tebuconazole in environmental water samples with preconcentration by cartridges packed with SiO2 microspheres prior to LC. Several parameters such as the volume and composition of eluent, sample flow rate, sample pH, and sample volume were optimized. Under the optimal conditions, excellent detection limits (S/N = 3) and precision (RSD, n = 6) were 0.02 ng mL?1, 1.3% for metalaxyl, 0.02 ng mL?1, and 2.4% for myclobutanil and 0.08 ng mL?1 and 4.3% for tebuconazole, respectively. The method was applied to the analysis of real-water samples, and satisfactory results were obtained. The average spiked recoveries were in the range of 86.3–97.5%. These results indicate that SiO2 microspheres have great potential to be used as a novel solid phase extraction adsorbent that could have wide applications in the environmental field.  相似文献   

8.
A simple and sensitive liquid chromatographic assay with fluorescence detection assay was developed for the determination of zearalenone levels in rat serum. The assay utilized a single liquid–liquid extraction with t-butyl methyl ether and isocratic elution using a mobile phase consisting of acetonitrile and 0.1% triethylamine in distilled water (pH = 6) (50:50, v/v). Linearity was observed over a concentration range from 10 to 1,000 ng mL?1 (r = 0.9995), with the limit of quantification at 10 ng mL?1 with 100 μL of rat serum. The validated assay was applied to a pharmacokinetic study in rats.  相似文献   

9.
In this work, β-CD-based polyurethane copolymers (β-CDPU) have been prepared by reacting β-CD with hexamethylene diisocyanate as cross-linked agent in dry DMF. This polymer showed high selectivity for preconcentration of Pb(II) at trace level prior to its flame atomic absorption spectrometric determination. The effect of several parameters such as pH, flow rate of sample, eluent kind and volume was investigated. The adsorption behaviors and mechanisms of Pb(II) on the samples were also studied. The maximum adsorption amount of Pb(II) was 8 mg g?1 with the preconcentration factor of 250 for Pb(II). The Langmuir isotherm was proved to describe the adsorption data better than the Freundlich isotherm and a pseudo-first-order kinetic model fits the adsorption kinetic processes well. The calibration curve was linear in the range of (3–200 ng mL?1) with a correlation coefficient of 0.9996. The limit of detection based on three times the standard deviation of the blank was 1.15 ng mL?1. The relative standard deviations for the determination of 10 and 100 ng mL?1 of Pb(II) were 3.60 and 0.43 % (n = 10), respectively. The method was successfully applied to the determination of lead in some environmental samples such as Tehran and Bushehr drinking water, river water and dust samples.  相似文献   

10.
《Analytical letters》2012,45(16):2643-2654
Dispersive liquid–liquid microextraction based on solid formation without a disperser combined with high-performance liquid chromatography has been developed for the determination of 4-tert-butylphenol, 4-n-nonylphenol, and 4-tert-octylphenol. This method is rapid, easy, and uses only 10 µL of a low toxicity organic solvent (1-hexadecanethiol) for the extraction solvent and no disperser solvent. The extraction time and centrifugation time require less than 10 min. The linear range was 1–500 ng mL?1 for 4-tert-butylphenol, 2–1000 ng mL?1 for 4-tert-octylphenol, and 5–500 ng mL?1 for 4-n-nonylphenol with r2 ≥ 0.9986. The detection limits were between 0.2 and 1.5 ng mL?1. The recoveries of lake and river water samples were in the range of 79% to 108%, and the relative standard deviations were 5% to 10%.  相似文献   

11.
《Analytical letters》2012,45(13):1764-1776
A rapid, sensitive, and specific high-performance liquid chromatography tandem mass spectrometric method was developed for the simultaneous determination and confirmation of amoxicillin and clavulanic acid in plasma. Plasma sample was subjected to a simple deproteinization with acetonitrile, and then the supernatant was directly diluted by water. Analysis was performed on a Phenomenex Luna C8 reversed-phase column by detection with mass spectrometry in negative ions multiple reaction monitoring mode. A gradient elution program with 0.1% formic acid and acetonitrile was performed at a flow of 0.25 mL min?1. There is good linearity in the range of 0.5–500 ng mL?1 for both amoxicillin and clavulanic acid. The decision limits of amoxicillin and clavulanic acid were 0.06 ng mL?1 and 0.08 ng mL?1 in plasma, respectively, and the detection capabilities of two analytes were below 0.5 ng mL?1. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The extraction recoveries of amoxicillin and clavulanic acid were between 102% and 115% in plasma at three spiked levels of 0.5, 50, and 500 ng mL?1, with the relative standard deviations less than 15% for each analyte. The developed method was applied to pharmacokinetic studies of amoxicillin and clavulanic acid tablets in healthy beagles.  相似文献   

12.
A method combining immunoaffinity chromatography with gas chromatography–mass spectrometry (GC–MS) has been established for determination of ractopamine residues in swine liver and urine. After clean-up on an immunoaffinity chromatography column, GC–MS analysis revealed recovery from blank swine liver and urine fortified at 2.5–20 ng g?1 (ng mL?1 for urine), respectively, was 68.2–78.6 and 76.2–83.1%. The limits of detection and quantification were 0.5 ng g?1 (or ng mL?1) and 2.0 ng g?1 (or ng mL?1), respectively. The procedure was used for analysis of ractopamine residues in samples of swine liver and urine in which the levels were unknown. The amounts detected were 9–216 ng g?1 (ng mL?1).  相似文献   

13.
《Analytical letters》2012,45(14):2096-2107
A simple, sensitive, and selective method for the determination of gallium and indium in different samples at trace levels is presented. This method was based on complexation of analyzes with 2-(5-bromo-2- pyridylazo)-5-diethylaminophenol (5-Br-PADAP) in the presence of t-octylphenoxy-polyethoxyethanol (Triton X-100). After phase separation, the analyzed concentrations were determined by inductively coupled plasma optical emission spectrometry. Quantitative extraction of gallium and indium was performed at pH 7.0, 1.7 mmol L?1, 5-Br-PADAP, 1.3% (w/v) Triton X-100 and at 75°C. The relative standard deviations (RSD) of this method were between 0.3% and 1.6% (C = 20 ng mL?1, n = 9). The calibration curve is linear over the concentration range 6–200 ng mL?1 for gallium and 2–200 ng mL?1 for indium, respectively. The limits of detection (LOD) for gallium and indium were 0.72 and 0.28 ng mL?1, respectively. The results showed the developed method was not susceptible to matrix effects, providing recoveries between 98% and 102%. The accuracy of the developed method was evaluated by the analysis of spiked certified reference materials. The developed method was successfully applied to gallium and indium determination in urine and lake water with satisfactory results.  相似文献   

14.
《Analytical letters》2012,45(7):1210-1223
A new magnetic adsorbent, 2,2′-thiodiethanethiol grafted with tetraethyl orthosilicate modified Fe3O4 nanoparticles, was developed for the separation and preconcentration of Hg, Pb, and Cd in environmental and food samples. The concentrations of Pb and Cd were determined by inductively coupled plasma–optical emission spectrometry; Hg was determined by cold vapor atomic absorption spectrometry. A comprehensive study on the factors affecting the extraction and desorption efficiencies was performed. Under the optimized conditions, the method was linear in the 0.01–750 ng mL?1 range (before preconcentration) with detection limits of 4, 8, and 2 ng L?1 for Hg, Pb, and Cd, respectively. Relative standard deviations of 2.3, 2.9, and 2.4% (concentration 50 ng mL?1, n = 7) and high preconcentration factors of 291, 285, and 288 were also obtained for Hg, Pb, and Cd. The accuracy of the proposed method was validated by analyzing a water certified reference material with satisfactory recoveries. The method was successfully applied to the determination of the analytes in tap and mineral waters and canned tuna fish samples.  相似文献   

15.
A simple, rapid and sensitive liquid chromatography/electrospray tandem mass spectrometry quantitative detection method, using amantadine as internal standard, was developed for the simultaneous analysis of paracetamol, pseudoephedrine and chlorpheniramine concentrations. Analytes were extracted from plasma samples by liquid–liquid extraction with n-hexane–dichloromethane–2-propanol (2:1:0.1, v/v), separated on a C18 reversed-phase column with 0.1% formic acid–methanol (40:60, v/v) and detected by electrospray ionization mass spectrometry in positive multiple reaction monitoring mode. Calibration curves for plasma were linear over the concentration range 10–10,000 ng mL?1 of paracetamol, 2–2,000 ng mL?1 of pseudoephedrine and 0.2–200 ng mL?1 of chlorpheniramine. The method has a lower limit of quantitation of 10 ng mL?1 for paracetamol, 2.0 ng mL?1 for pseudoephedrine and 0.2 ng mL?1 for chlorpheniramine. Recoveries, precision and accuracy results indicate that the method was reliable within the analytical range, and the use of the internal standard was very effective for reproducibility by LC-MS-MS. This method is feasible for the evaluation of pharmacokinetic profiles of a novel multicomponent sustained release formulation containing 325 mg of paracetamol, 30 mg of pseudoephedrine hydrochloride and 2 mg of chlorpheniramine maleate. It is the first time the pharmacokinetic evaluation of a novel sustained-action formulation containing paracetamol, pseudoephedrine and chlorpheniramine has been elucidated in vivo using LC-MS-MS.  相似文献   

16.
A sensitive high performance liquid chromatographic (HPLC) method has been developed and validated for the simultaneous determination of four local anaesthetics: lidocaine, proparacaine, bupivacaine and oxybuprocaine. A full factorial design was used. The chromatographic separation was achieved using a Bondesil C8 (4.6 × 2.5 mm i.d., particle size 5 μm) analytical column. An optimised mobile phase consisted of acetonitrile and sodium dihydrogen phosphate (pH = 3.0, 20 mM) (30:70, v/v) at a flow rate of 1.2 mL min?1. Local anaesthetics detection was performed by UV-Vis detector at 220 nm. The retention times for lidocaine, proparacaine, bupivacaine and oxybuprocaine were 5.74, 9.28, 16.84 and 26.26 min, respectively. HPLC-UV-Vis method was linear in the range of 50–5,000 ng mL?1 for lidocaine and proparacaine and 100–5,000 ng mL?1 for bupivacaine and oxybuprocaine. The limit of detection (LOD) was 25 ng mL?1 for lidocaine, proparacaine and 30 ng mL?1 for bupivacaine and oxybuprocaine. The limit of quantification (LOQ) was found to be 50 ng mL?1 for lidocaine, proparacaine and 100 ng mL?1 for bupivacaine, oxybuprocaine. In intra-day and inter-day precision and accuracy analysis, the relative standard deviation was found to be less than 8%.  相似文献   

17.
A sensitive and simple liquid chromatography-mass spectrometry method was developed to determine the immunosuppressant tacrolimus in human skin samples after treatment with the commercially available ointment. Utilizing diffusion cell experiments according to Franz, human skin samples were treated with ointment containing tacrolimus and the extraction procedure of the drug was optimized. The analytical assay was performed using an LC system consisting of a reversed phase C18 column and an isocratic mobile phase, coupled with electrospray ionization mass spectrometry. The detection was performed in the positive selected ion monitoring mode. Mycophenolate mofetil was used as internal standard to control the stability of the electrospray ionization. The calibration curve was linear for tacrolimus over the range of 5–1,000 ng mL?1 (average correlation coefficient of r 2 = 0.9941) with a limit of detection (LOD) of 2 ng mL?1, with a limit of quantification (LOQ) of 5 ng mL?1 and with a precision of 8.70%. The analytical assay described in this paper was successfully applied in order to quantify tacrolimus in human skin samples as well as in the commercially available ointment.  相似文献   

18.
A high performance liquid chromatography method is presented for the determination of valproic acid levels in human plasma. The method was based on pre-column derivatization using N-(1-naphthyl)ethylenediamine as a new labeling agent. The calibration curve was linear in the investigated concentration range between 0.1 and 100 μg mL?1 and showed good accuracy and reproducibility. The assay provided a limit of quantification of 0.1 μg mL?1 for valproic acid and a limit of detection of 10 ng mL?1, respectively. The presented method was successfully applied to the determination of valproic acid levels in plasma after oral administration of 600 or 800 mg of sodium valproate.  相似文献   

19.
A monolithic column, prepared from a vinyl ester resin used as both monomer and cross-linking agent, has been used to remove matrix compounds from biological fluid. Using this column, nisoldipine in human plasma samples could be enriched online and the protein could be eluted. For this method of extraction, response (peak area) was a linear function of concentration in the range 2–80 ng mL?1, with a linear regression coefficient of 0.99985. The limit of detection for nisoldipine in plasma was 1.2 ng mL?1. For nisoldipine at concentrations of 10, 30, and 70 ng mL?1 RSD were 4.33, 6.63, and 4.57%, respectively. Recovery for both extraction (>73.6%) and the entire analytical method (>90.7%) were acceptable for screening of plasma for nisoldipine. The 12-hour pharmacokinetic profile of nisoldipine in mice after oral administration (0.3 mg kg?1) was investigated. The results indicated the method could be used for therapeutic monitoring of nisoldipine and enabled simple and rapid assay of the drug in plasma.  相似文献   

20.
Arsenazo III modified maghemite nanoparticles (A-MMNPs) was used for removing and preconcentration of U(VI) from aqueous samples. The effects of contact time, amount of adsorbent, pH and competitive ions was investigated. The experimental results were fitted to the Langmuir adsorption model in the studied concentration range of uranium (1.0 × 10?4–1.0 × 10?2 mol L?1). According to the results obtained by Langmuir equation, the maximum adsorption capacity for the adsorption of U(VI) on A-MMNPs was 285 mg g?1 at pH 7. The adsorbed uranium on the A-MMNPs was then desorbed by 0.5 mol L?1 NaOH solution and determined spectrophotometrically. A preconcentration factor of 400 was achieved in this method. The calibration graph was linear in the range 0.04–2.4 ng mL?1 (1.0 × 10?10–1.0 × 10?8 mol L?1) of U(VI) with a correlation coefficient of 0.997. The detection limit of the method for determination of U(VI) was 0.01 ng mL?1 and the relative standard deviation (R.S.D.) for the determination of 1.43 and 2.38 ng mL?1 of U(VI) was 3.62% and 1.17% (n = 5), respectively. The method was applied to the determination of U(VI) in water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号