首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Analytical letters》2012,45(8):1318-1334
Abstract

New reversed-phase liquid chromatographic methods, with UV detection, were developed for the quantitative estimation of flurbiprofen in rabbit blood serum and aqueous humor. The mobile phase and other chromatographic conditions were optimized to minimize interference from biological matrix and at the same time provide sufficient sensitivity for the method to be adopted for in vivo studies of ophthalmic formulations of flurbiprofen. Acetonitrile was used to precipitate proteins from serum or aqueous humor during sample preparation. A mobile phase of methanol: acetonitrile: phosphate buffer pH 5.6 (40:20:40) was employed with UV detection at 248 nm for estimation of drug in both the biological matrix. The retention time and asymmetry factor for the proposed method of estimation in serum and aqueous humor was found to be 3.1312±0.0101 min and 1.1310±0.0091 respectively. The linear regression equations obtained by least square regression method, were Area (µV sec) = 52.27 × Conc. (in ng/ml)–1618.70 in serum and Area (µV sec) = 61.79 × Conc. (in ng/ml) ? 783.24 in aqueous humor. The results of analysis were treated statistically, as per ICH guidelines for validation of analytical procedures, USP-2003, and by recovery studies. The results were found to be accurate, reproducible and free from interference. The developed methods were further used for estimation of flurbiprofen in rabbit serum and aqueous humor following single topical administration of in-house aqueous drop and market formulation to rabbit eye.  相似文献   

2.
《Analytical letters》2012,45(18):3297-3308
Abstract

The present work describes a simple reversed-phase high-performance liquid chromatographic method that has been developed and validated for simultaneous estimation of acetaminophen, chlorzoxazone, and aceclofenac in tablet dosage form. The estimation was carried out on an Luna C18 (5 µm × 25 cm × 4.6 mm i.d.) column using a mixture of buffer, methanol, and acetonitrile in the ratio 215:130:155 with final pH of 6.5 as a mobile phase, at a flow rate of 1.5 ml/min. Ultraviolet (UV) detection was performed at 275 nm. Total run time was 10 min; these three drugs (acetaminophen, chlorzoxazone, and aceclofenac) were eluted at the retention times of 2.055, 5.096, and 7.605 min respectively. The method was validated for accuracy, precision, linearity, specificity, and sensitivity as per ICH norms.. From the validation study it was found that the method is specific, rapid, accurate, precise, and reproducible. Calibration curves were linear over the concentration ranges of 5–50 µg/ml for acetaminophen and chlorzoxazone, and 5–30 µg/ml for aceclofenac. All the validation study was found statistically significant because all the statistical parameters were within the acceptance range (i.e., COV % < 2.0 and S.D. < 1.0 for both accuracy and precision). The limit of detection (LOD) values were 16.2, 14.6, and 4.8 ng/ml, and LOQ values were 49.0, 46.5, and 14.5 ng/ml for acetaminophen, chlorzoxazone, and aceclofenac respectively. High recovery and low COV % revealed the reliability of the method for quantitative study of three drugs in Micronac-MR tablets. The method is a rapid and cost-effective quality-control tool for routine quantitative analysis of acetaminophen, chlorzoxazone, and aceclofenac in tablet dosage form.  相似文献   

3.
A simple, selective, rapid, precise and accurate reverse phase high pressure liquid chromatographic method has been developed for the simultaneous estimation of diclofenac sodium and rabeprazole sodium from pharmaceutical formulations. The method was developed using a HiQ SiL C18 (250 mm × 4.6 mm i.d.) column with a mobile phase consisting of methanol:water, (80:20 v/v), at a flow rate of 1.25 mL min?1. Detection was carried out at 284 nm. Indapamide was used as an internal standard. The developed method was validated for linearity, accuracy, precision, limit of detection and limit of quantitation. The proposed method can be used for the estimation of these drugs in combined dosage forms.  相似文献   

4.
Asfak  Vora  Mrinalini  Damle  Leena  Bhat  Rahul  Godge 《Chromatographia》2007,66(11):941-943

A simple, selective, rapid, precise and accurate reverse phase high pressure liquid chromatographic method has been developed for the simultaneous estimation of diclofenac sodium and rabeprazole sodium from pharmaceutical formulations. The method was developed using a HiQ SiL C18 (250 mm × 4.6 mm i.d.) column with a mobile phase consisting of methanol:water, (80:20 v/v), at a flow rate of 1.25 mL min−1. Detection was carried out at 284 nm. Indapamide was used as an internal standard. The developed method was validated for linearity, accuracy, precision, limit of detection and limit of quantitation. The proposed method can be used for the estimation of these drugs in combined dosage forms.

  相似文献   

5.
An accurate, sensitive and least time consuming reverse phase high performance liquid chromatographic (RP‐HPLC) method for the estimation of captopril in the presence of non steroidal anti‐inflammatory drugs in formulation and human serum has been developed and validated. Chromatographic separation was conducted on prepacked Purospher star C18 (5 μm, 25 × 0.46 cm) column at room temperature using methanol:water (80:20 v/v) as a mobile phase, pH adjusted at 2.8 with o‐phosphoric acid and at a flow rate of 1.0 mL min−1, while UV detection was performed at 227 nm. The limit of detection and quantification for captopril were 1 and 0.35 ng mL−1, while that for (NSAID's) i.e. flurbiprofen, ibuprofen, diclofenac sodium and mefenamic acid LOD were 0.2, 1, 2 and 0.4 ng mL−1 respectively and LOQ were 0.9, 2.9, 8 and 1 ng mL−1 Analytical recovery was > 98.1%. The method used for the quantitative analysis of commonly administered non steroidal anti‐inflammatory drugs (NSAID's) i.e. ibuprofen, flurbiprofen, diclofenac sodium and mefenamic acid alone or in combination with captopril from API (active pharmaceutical ingredients), dosage formulations and in human serum. The established method is rapid (RT < 12 min), accurate (recovery > 98.1%), selective (no interference of excepients and other commonly used drugs and food) and sensitive (LOQ 3.5 ng mL;‐1) and reproducible (SD ± 0.003).  相似文献   

6.
A simple, precise, accurate, selective, and sensitive reversed-phase LC–UV method has been developed for simultaneous analysis of diltiazem and non-steroidal anti-inflammatory drugs (NSAIDs) in the bulk drug, tablet dosage forms, and human serum. Chromatographic separation of the drugs was performed at ambient temperature on a C18 stationary phase with 80:20 (v/v) methanol–water, pH 3.1 ± 0.02, as isocratic mobile phase. The mobile phase flow rate was initially 0.5 mL min?1 then increased to 1 mL min?1. All the NSAIDs were well separated from each other and from diltiazem. Total run time was 10 min. The assay was successfully applied to pharmaceutical formulations and serum and there was no chromatographic interference from tablet excipients. The method was linear in the range 1.25–50 μg mL?1 both for diltiazem and the NSAIDs. The suitability of this HPLC method for quantitative analysis of the drugs was proved by validation in accordance with International Conference on Harmonization (ICH) guidelines. The validation results, and results from statistical analysis of the data, demonstrated the method was reliable.  相似文献   

7.
《Analytical letters》2012,45(11):2128-2140
Abstract

A new, simple, and sensitive reverse‐phase liquid chromatographic method was developed and validated for the estimation of Lercanidipine hydrochloride in rabbit serum using UV detector under isocratic conditions. After subjecting serum to simple and efficient one‐step extraction procedure, 100 µl of sample was injected onto high‐performance liquid chromatography system. The detector response was linear in the concentration range of 25–1000 ng/ml. The developed method was validated as per standard guidelines. Validation demonstrated accuracy, precision, and selectivity of the proposed method. The drug was found to be stable under various processing and storage conditions.  相似文献   

8.
《Analytical letters》2012,45(11):1588-1602
Abstract

This article describes validated high-performance liquid chromatographic (HPLC) and high-performance thin-layer chromatographic (HPTLC) methods for simultaneous estimation of alprazolam (ALZ) and sertraline (SER) in pure powder and tablet formulation. The HPLC separation was achieved on a Nucleosil C18 column (150 mm long, 4.6 mm i.d., and 5-µm particle size) using acetonitrile and phosphate buffer (50 + 50 v/v), pH 5.5, as the mobile phase at a flow rate of 1.0 mL/min at ambient temperature. The HPTLC separation was achieved on an aluminum-backed layer of silica gel 60 F254 using acetone/toluene/ammonia (6.0:3.0:1.0, v/v/v) as the mobile phase. Quantification with the HPLC method was achieved with ultraviolet (UV) detection at 230 nm over the concentration range 3–18 µg/mL for both drugs with mean recovery of 101.86 ± 0.21 and 100.57 ± 0.31% for ALZ and SER, respectively. Quantification in HPTLC was achieved with UV detection at 230 nm over the concentration range of 400–1400 ng/spot for both drugs with mean recoveries of 101.32 ± 0.15 and 100.38 ± 0.51% for ALZ and SER, respectively. These methods are rapid, simple, precise, sensitive, and are applicable for the simultaneous determination of ALZ and SER in pure powder and formulations.  相似文献   

9.
《Analytical letters》2012,45(2):328-339
A new method for nimesulide was developed using ion-pair reversed phase liquid chromatography and tetrabutylammonium hydrogen sulfate as the ion-pairing reagent. The influence of the ion pair forming reagent concentration, pH, and mobile phase composition on the retention time of nimesulide were studied. The optimum experimental conditions included a C18 column, a mobile phase of a 50/50 (v/v) mixture of acetonitrile and 15 mM phosphate buffer (pH 8.00) containing 6 mM tetrabutylammonium hydrogen sulfate, 25°C, isocratic elution, a flow rate of 1 mL/min, a run time of 10 minutes, and photodiode array detection at 404 nm. From the analysis of the results, the mechanism for the separation of nimesulide was also established. The retention time for nimesulide was 4.76 ± 0.05 min. The method was linear between concentrations of 9 µg/mL to 64 µg/mL, with limits of detection and quantification of 1.111 µg/mL and 3.390 µg/mL, respectively. The method is simple, rapid, accurate, and precise, and successfully applied for the determination of nimesulide in pharmaceutical products.  相似文献   

10.
A simple, sensitive and accurate high performance thin layer chromatographic (HPTLC) method has been developed for the estimation of withaferin-A and withanolide-A in different plant parts such as, leaf, root, stem and fruit of two morphotypes of Withania somnifera. HPTLC of W. somnifera methanolic extract was performed on Si 60 F254 (20 cm × 20 cm) plates with toluene:ethyl acetate:formic acid (5:5:1), as mobile phase. Quantitative evaluation of the plate was performed in the absorption-reflection mode at 530 nm. The method was validated for precision, repeatability, and accuracy. The average recovery of withaferin-A and withanolide-A in two levels were 96.0 and 96.7%, showing the excellent reproducibility of the method. The calibration curves were linear for both in the range of 200–3,200 ng. The technique has been applied, for the first time, for the estimation of withaferin-A and withanolide-A in different parts of the two morphotypes of Withania somnifera. The method is simple, precise, specific, sensitive and accurate and can be used for routine analysis as well as for quality control of raw materials and herbal formulations.  相似文献   

11.
Rapid liquid chromatographic procedures for analytical quality control of pharmaceutical preparations and human serum containing antihistamine drugs, meclizine and buclizine alone or in combination with pyridoxine are proposed, using acetonitrile:water (80:20) as a mobile phase (pH adjusted to 2.6), methylparaben as internal standard and UV detection was made at 230 nm. The results obtained showed a good agreement with the declared content. The method shows good linearity in the range of 30–10,000 ng mL?1 for pyridoxine and 25–10,000 ng mL?1 for meclizine and buclizine serum concentrations with a correlation coefficient 0.9999 (inter- and intra-day CV < 3.91%). The recovery was >97.8%. The proposed method may be used for the quantitative analysis of meclizine and buclizine alone or in combination with pyridoxine from raw materials, in bulk drugs, dosage formulations and in serum.  相似文献   

12.
A method is described for the simultaneous determination of paracetamol, tizanidine, and diclofenac in mixtures. The method was based on HPLC separation of the three drugs followed by UV detection at 254 nm. The separation was carried out on a Hypersil ODS, C18 (250 x 4.6 mm id, 10 microm particle size) column using the mobile phase aqueous 0.2% ammonium carbonate-methanol (60 + 40, v/v) at a flow rate of 1 mL/min. The linear regression analysis data were used for the regression curve in the range of 170-10 000 ng/mL for paracetamol, 120-10 000 ng/mL for tizanidine, and 20-10 000 ng/mL for diclofenac. No chromatographic interference from tablet excipients was found. In order to check the selectivity of the proposed method, degradation studies were carried out using hydrolysis (acid, basic, and neutral), thermolysis, and oxidation. The developed method, after being validated in terms of precision, robustness, recovery, LOD, and LOQ, was successively applied to the analysis of pharmaceutical formulations and human serum.  相似文献   

13.
《Analytical letters》2012,45(15):2797-2807
Abstract

A rapid, convenient, and sensitive liquid chromatography–electrospray ionization–mass spectrometry method was developed and validated for the quantification of hydrochlorothiazide in human plasma. The samples were first spiked with the internal standard, and the analyte was then extracted with ethyl acetate. The chromatographic separation was achieved on a C18 column by using water–acetonitrile (68:32, v/v) as mobile phase. The method was linear within the range of 2.5–200 ng/ml. The lower limit of quantification was 1.0 ng/ml. Finally, the validated method was successfully applied for the evaluation of the pharmacokinetic profiles of hydrochlorothiazide in healthy male Chinese volunteers.  相似文献   

14.
《Analytical letters》2012,45(10):1833-1843
Abstract

A simple and rapid liquid chromatographic assay method using a fluorescence detector for quantitation of dihydroergotamine in plasma without extraction was developed. After precipitating the protein with acetonitrile, the supernatant liquid was directly injected for analysis. Chromatographic separation was achieved on C18 reversed phase column and the mobile phase was the isocratic mixture of methanol, acetonitrile and glycine buffer (0.5:3.5:6.0). With this eluting solvent the drug and its internal standard were well separated from the interference of the plasma sample. The average recovery of dihydroergotamine from 6 replicate samples of different concentrations (5-30 ng/ml) were 92.2 ± 3.37%. The minimum amount of dihydroergotamine detectable by this method was 2 ng/ml of sample.  相似文献   

15.

Rapid liquid chromatographic procedures for analytical quality control of pharmaceutical preparations and human serum containing antihistamine drugs, meclizine and buclizine alone or in combination with pyridoxine are proposed, using acetonitrile:water (80:20) as a mobile phase (pH adjusted to 2.6), methylparaben as internal standard and UV detection was made at 230 nm. The results obtained showed a good agreement with the declared content. The method shows good linearity in the range of 30–10,000 ng mL−1 for pyridoxine and 25–10,000 ng mL−1 for meclizine and buclizine serum concentrations with a correlation coefficient 0.9999 (inter- and intra-day CV < 3.91%). The recovery was >97.8%. The proposed method may be used for the quantitative analysis of meclizine and buclizine alone or in combination with pyridoxine from raw materials, in bulk drugs, dosage formulations and in serum.

  相似文献   

16.
《Analytical letters》2012,45(5):757-766
Abstract

A high‐performance liquid chromatography (HPLC) method has been developed for the determination of ochratoxin A (OTA) in human blood serum. Samples were purified on a C18 solid phase extraction column. The developed method required a relatively low serum volume (0.5 ml). Significant correlation (r of 0.998) was found over the range from 0.10 to 8 ng/ml, with a detection limit of 0.1 ng/ml and better performance in terms of precision and accuracy. Mean recoveries at 0.5 and 2 ng/ml were respectively 69.7±1.2 and 71.9±2.8%. This method was used as a rapid and noninvasive tool to assess human exposure to OTA. Among 40 analyzed serum samples, 27.5% were found to contain OTA with levels going from 0.1 to 11.98 ng/ml with a mean concentration of 0.73±2.35 ng/ml.  相似文献   

17.
A method based on liquid chromatography with negative ion electrospray ionization and tandem mass spectrometry is described for the determination of nimesulide in human plasma. Liquid-liquid extraction using a mixture of diethyl ether and dichloromethane was employed and celecoxib was used as an internal standard. The chromatographic run time was 4.5 min and the weighted (1/x) calibration curve was linear in the range 10.0-2000 ng x ml(-1). The limit of quantification was 10 ng x ml(-1), the intra-batch precision was 6.3, 2.1 and 2.1% and the intra-batch accuracy was 3.2, 0.3 and 0.1% for 30, 300 and 1200 ng x ml(-1) respectively. The inter-batch precision was 2.3, 2.8 and 2.7% and the accuracy was 3.3, 0.3 and 0.1% for 30, 300 and 1200 ng x ml(-1) respectively. This method was employed in a bioequivalence study of one nimesulide drop formulation (nimesulide 50 mg x ml(-1) drop, Medley S/A Indústria Farmacêutica, Brazil) against one standard nimesulide drop formulation (Nisulid, 50 mg x ml(-1) drop, Astra Médica, Brazil). Twenty-four healthy volunteers (both sexes) took part in the study and received a single oral dose of nimesulide (100 mg, equivalent to 2 ml of either formulation) in an open, randomized, two-period crossover way, with a 2-week washout interval between periods. The 90% confidence interval (CI) for geometric mean ratios between nimesulide and Nisulid were 93.1-109.6% for C(max), 87.7-99.8% for AUC(last) and 88.1-99.7% for AUC(0-infinity). Since the 90% CI for the above-mentioned parameters were included in the 80-125% interval proposed by the US Food and Drug Administration, the two formulations were considered bioequivalent in terms of both rate and extent of absorption.  相似文献   

18.
《Analytical letters》2012,45(4):561-570
Abstract

A simple reverse‐phase high‐performance liquid chromatographic method for the determination of tenofovir disoproxil fumarate (TDF) in pharmaceutical formulations and human plasma samples has been developed and validated. Piroxicam (PRX) was used as an internal standard. The assay of the drug was performed on a CLC C18 (5 μ, 25 cm×4.6 mm i.d.) with UV detection at 259 nm. The mobile phase consisted of acetonitrile–water mixture in the ratio of 75∶25, and a flow rate of 1 ml/min was maintained. The standard curve was linear over the range of 0.2–10 µg/ml (r 2=0.9966). Analytic parameters have been evaluated. Within‐day and between‐day precision as expressed by relative standard deviation was found to be less than 2%. The method has been applied successfully for the determination of TDF in spiked human plasma samples and pharmaceutical formulations.  相似文献   

19.
A rapid, selective and sensitive reversed-phase liquid chromatographic (LC) method was developed for the determination of piribedil in human serum, urine and pharmaceutical dosage form. LC analysis was carried out using reversed-phase isocratic elution with a C18 column and a mobile phase of 0.01 M phosphate buffer-acetonitrile (50:50, v/v). The chromatograms showed good resolution and sensitivity with no interference of human serum and urine. Piribedil concentrations were determined using diode array detection at 240 nm. Sildenafil citrate was used as internal standard. The limit of quantification (LOQ) and limit of detection (LOD) concentrations were 107.2 and 321.6 pg mL?1, 96.6 and 290.4 pg mL?1, 161.7 and 53.9 pg mL?1 for urine, serum and pharmaceutical dosage forms, respectively. The method was validated for its linearity, precision and accuracy and applied to the tablets, urine and human serum. In addition, the results were compared to those obtained from UV-spectrophotometry.  相似文献   

20.
《Analytical letters》2012,45(18):2811-2818
Plumbagin, a naturally occurring naphthoquinone derivative, is known to possess various pharmacological activities. A rapid, sensitive, and specific high-performance liquid chromatographic method using fluorescence detection is reported for the determination of plumbagin in two Plumbago species and five polyherbal formulations. The method employed a reverse phase C18 column with isocratic elution using 65:35 pH 3.2 methanol and 0.1% aqueous o-phosphoric acid at a flow rate of 1.0 mL/min. Plumbagin displayed maximal fluorescence with excitation at 264 nm and emission at 605 nm. A linear calibration relationship was obtained for 1 to 10 µg/mL plumbagin with limits of detection and quantitation of 8 ng/mL and 30 ng/mL, respectively. The relative standard deviation values for intraday and interday precision were less than 2%. The recoveries were greater than 97% with relative standard deviations less than 3%. This is the first study to employ high-performance liquid chromatography with fluorescence detection for the determination of plumbagin. The method was rapid, sensitive, and accurate for the analysis of plants and polyherbal formulations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号