首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Analytical letters》2012,45(5):890-901
Abstract

A highly selective polyvinyl chloride (PVC) membrane electrode, based on N,N′‐(aminoethyl)ethylenediamide bis(2‐benzoideneimine) binuclear copper(II) complex [Cu(II)‐AEBB] as neutral carrier, was prepared for thiocyanate (SCN?) determination, which displays an anti‐Hofmeister selectivity sequence for a series of anions in the following order: SCN?>ClO4 ?>Sal? > I?>NO3 ?>Br?> Cl?>NO2 ?>SO3 2?>F?>H2PO4 ?>SO4 2?. The electrode exhibited near‐Nernst response for SCN? with a slope of –59.0 mV/decade over a wide concentration range (8.5×10?7~6.8×10?1 mol/L) with a detection limit of –5.0×10?7 mol/L in pH 5.0 phosphate buffer solution at 25°C. Alternating current (AC) impedance and equivalent circuits were used to investigate the thiocyanate response mechanism of the membrane doped with [Cu(II)‐AEBB].  相似文献   

2.
《Analytical letters》2012,45(2):369-386
Abstract

Three kinds of transition metal chelates of unsymmetrical tetradentate Schiff base, o‐hydroxybenzophenone‐1,2‐diaminobenzene‐pyrrole‐2‐carbaldehyde(H2L), were synthesized to prepare anion‐selective electrodes and their anion response characteristics were investigated. The results show that the performances of the electrodes are considerably influenced by the nature of the central metals. The proposed electrode with the Cu(II)‐chelate and cationic additive demonstrated an anti‐Hofmeister selectivity sequence with a good selectivity towards thiocyanate in the following order: Thiocyanate>iodide>salicylate>perchlorate>bromide>nitrite>chloride>acetate>fluoride>nitrate>sulfite>sulfate. The electrode had an excellent linear response to thiocyanate from 3.4×10?7 to 1.0×10?1 M in phosphate buffer solution at pH 5.0 with a slope of ?58.7 mV per decade, a detection limit of 1.6×10?7 M, and a fast response time within 5 s over the entire concentration series. Spectroscopic techniques and AC impedance were used to investigate the response mechanism to thiocyanate of the membrane doped with Cu(II)‐chelate. The preliminary application of the electrode for determination of thiocyanate in wastewater and urine samples is reported.  相似文献   

3.
《Analytical letters》2012,45(14):2683-2692
Abstract

DNA was immobilized onto a carbon nanotube surface through cyclic voltammetry, in which paste electrode (PE) was subjected to lead and copper trace ion analysis. Optimized conditions for square‐wave stripping voltammetry were then searched. The results indicated three other linear working ranges—3–21 mg l?1, 2–16 µg l?1, and 3–17 ng l?1 Pb(II) Cu(II)—within an accumulation time of 190 s in 0.1‐M ammonium phosphate electrolyte solutions of pH 10.0. At the optimized conditions, the detection limit (S/N) was pegged at 0.4 ng l?1 (1.93×10?12 M Pb(II) and 6.29×10?12 M Cu(II)). And the relative standard deviation at 10 mg l?1 Pb(II) and Cu(II) was a 0.074 and 0.069% precision, in 15 measurements. The method can be applied to assays of fish tissue.  相似文献   

4.
《Analytical letters》2012,45(4):683-695
Abstract

A highly selective and sensitive triiodide sensor based on a 2‐(((2‐(((E)‐1‐(2‐hydroxy phenyl) methylidine) amino) phenyl) imino) methyl) phenol with iodine (CTC) as membrane carrier was developed. The electrode revealed a Nernstian behavior over a very wide triiodide‐ion concentration range (5.0×10?8–1.0×10?2 M), and relatively low detection limit (3.0×10?8 M). The potentiometric response is independent of the pH of solution in the pH range of 3.0–10.0. The electrodes manifest advantages of low resistance, very fast response (<12 s), and most importantly, good selectivities relative to a wide variety of inorganic and organic anions, including iodide, bromide, chloride, fluoride, sulfite, sulfate, cyanide, thiocyanate, and acetate. In fact, the selectivity behavior of the proposed triiodide ion‐selective electrode shows great improvements compared to the previously reported electrodes for the triiodide ion. The proposed membrane sensor can be used for at least 6 months without any significant divergences in the potential. The electrode was successfully applied as an indicator electrode in the titration of triiodide with thiosulfate ion.  相似文献   

5.
A highly selective PVC membrane electrode was prepared for thiocyanate (SCN?) determination, based on macrotricyclic binuclear Cu(II)–Schiff base complex as an ionophore. The novel macrotricyclic compound (cryptand) was synthesized by condensation of 4,4′-diamino-dibenzo-18-crown-6 with bis(4-formyl phenyl)terephthalate under high-dilution condition and the structure was confirmed by FT-IR, 1H NMR,13C NMR and MS studies. The Cu(II) complex of the compound was prepared and was examined for use as anion-selective electrode as a carrier which displays an anti-Hofmeister selectivity sequence in following order: SCN? > ClO4 ? > NO3 ? > CN? > I? > CO3 2? > NO2 ? > Br? > Cl? > SO4 2? with a preference for thiocyanate ion over many common anions. The electrode has a linear dynamic range between 1.0 × 10?7 and 1.0 × 10?1 M, with a Nernstian slope of ?58.9 mV decade?1 and detection limit of 3.1 × 10?8 M. The working pH range of the sensor was found be in the range of 3.0–8.0. It exhibits a fast response time of 20 s and has a lifetime of about 2 months. Application of the electrode for determination of thiocyanate in waste water samples and in human urine samples have also been demonstrated.  相似文献   

6.
《Electroanalysis》2005,17(20):1865-1869
A novel anion‐selective PVC membrane electrode based on bis‐[(3‐ferrocenyl)‐(2‐crotonic acid)] copper(II) complex [Cu(II)‐BFCA] as neutral carrier is described, which demonstrates excellent potentiometric response characteristics toward thiocyanate ion and anti‐Hofmeister selectivity sequence in following order: SCN?>I?>ClO >Sal?>Br?>NO >Cl?≈NO >SO >SO . The electrode shows a near‐Nernstian response for thiocyanate ion in a wide range of 9.0×10?7–1.0×10?1 M with a detection limit 6.8×10?7 M and a slope of ?59.1 mV/decade in pH 5.0 of phosphate buffer solution at 20 °C. The influences of lipophilic cationic and anionic additives on the response properties of the electrode were investigated. High sensitivity and wide linear dynamic range were observed for the electrode in the presence of hexadecyltrimethylammoniumborate (HTAB) as a lipophilic cationic additive. The electrode was successfully applied to the determination of thiocyanate ion in waste water and human saliva.  相似文献   

7.
本文报道了一种以牛磺酸双核铜络合物为中性载体的硫氰酸根PVC膜电极。该电极对硫氰酸根有良好的电位响应并呈现出anti-Hofmeister行为,其选择性顺序SCN->I->ClO4->Sal->NO3-> NO2-> Br- > Cl- > SO3-> SO4 2-。在20℃ pH 5.0的磷酸缓冲溶液中,其线性范围为1.0´10 -1~ 1.0´10-6mol×L-1,检测线为8.0×10 -7mol•L-1,斜率为 -56.5 mV/pcSCN-。紫外、红外和交流阻抗研究表明电极的高选择性与载体的立体结构和分析物与中心金属离子的作用相关。将该电极用于废水和人体尿液中硫氰酸根的测定,获得了较满意的结果。  相似文献   

8.
The prepared and characterized metformin ‐copper (II) complex was used as elecroactive material for modification of a new sensitive and selective modified carbon paste electrode (MCPE) for the potentiometric determination of copper (II) in water samples. The performance characteristics of MCPE were carried out. The electrode showed perfect potentiometric response for Cu (II) over concentration range of 1.0 × 10?6 – 5.0 × 10?2 mol L?1 with a detection limit of 1.0 × 10?6 mol L?1 with divalent slope value 30.8 ± 0.92 mV decade?1 over the pH range of 2–6 and exhibits fast response time of 9 s. Also, this electrode exhibited good selectivity towards Cu (II) ions with respect to other metal ions. The obtained results using the proposed electrode were in a good agreement with those obtained using the inductively coupled plasma (ICP) method.  相似文献   

9.
《Analytical letters》2012,45(16):3038-3049
Abstract

The lead(II) ion selective solid‐contact electrode based on polypyrrole film, covered with a polyvinyl chloride membrane has been prepared. Polypyrrole film was used as a mediating layer of the solid‐contact electrode due to the conductivity. Crown ether has been used as ionophores in polyvinyl chloride cocktail solutions. This solid‐contact electrode based on benzo‐15‐crown‐5 exhibited Nernstian‐response within 30 s response time over concentration range, 1×10?1~5×10?7 M. The selectivity of this electrode to other metal cations was comparatively good. This electrode showed much better results, such as detection range, slope, response time and reproducibility than conventional ion selective electrode and coated wire electrode.  相似文献   

10.
《Analytical letters》2012,45(4):595-606
A highly sensitive polyvinyl chloride (PVC) membrane electrode, based on copper(II)-bis(N-4-methylphenyl-salicyldenaminato) complex, (CuL2), as a carrier was reported for the determination of chromate ion. The influence of membrane composition, pH, and possible interfering anions on the response of the ion selective electrode was investigated. The sensor exhibited a Nernstian slope of 29.7 mV per decade when the chromate concentration was varied between 2.0 × 10?7–1.50 × 10?2 M in a wide pH range (6.0 to 9.0). The detection limit of the ion selective electrode was 9.2 × 10?8 M. The proposed sensor was used for at least 4 months without any considerable divergence in potential. It was applied as indicator electrode in potentiometric titration of chromate ion with Pb2+ and Tl+.  相似文献   

11.
Complexes of copper(II) and nickel(II) containing the drug mesalamine (5-ASA) have been synthesized and characterized by FT-IR, mass and UV–vis spectra, elemental analysis, and theoretical methods. The binding interactions between mesalamine and its Cu(II) and Ni(II) complexes with calf thymus DNA (ct-DNA) were investigated using absorption, fluorescence emission and circular dichroism (CD) spectroscopies, and viscosity measurements. Absorption spectra of 5-ASA, Cu(II) and Ni(II) complexes showed hypochromism. The calculated binding constants (Kb) obtained from UV–vis absorption studies were 1.27 × 103, 1.6 × 103, and 1.2 × 104 M?1 for 5-ASA, Cu(II) and Ni(II) complexes, respectively. The compounds induced detectable changes in the CD spectra of ct-DNA (B → A structural transition, B → C structural transition and stabilization of the right-handed B form, for mesalamine, Cu(II) and Ni(II) complexes, respectively). The competitive binding experiments with Hoechst 33258 indicated that 5-ASA and copper complex could interact as groove binders. Furthermore, Ni complex had no effect on the fluorescence intensity and peak position of MB-DNA system. Finally, the results obtained from experimental and molecular modeling showed that complexes bind to DNA via minor-groove binding.  相似文献   

12.
《Analytical letters》2012,45(9):1714-1735
Abstract

Highly selective poly(vinyl chloride) (PVC) membrane electrode based on recently synthesized mercury complex i.e., phenyl mercury (II) (2‐mercaptobezothiozolate) (PMMBT) as new carrier for iodide‐selective electrode by incorporating the membrane ingredients on the surface of graphite electrode are reported. The effect of various parameters including the membrane composition, pH, and possible interfering anions were investigated on the response properties of the electrode. The developed sensor exhibited Nernstian responses toward iodide over a wide concentration range of 1×10?7 to 0.1 M with slopes of 57.6±0.8 mV per decade of iodide concentration and detection limit of 8×10?8 M, over a wide pH ranges of 2.0–11.5. The sensors have response time of 0.5 s and can be used for at least 2 months without any considerable divergence in their potential response. The proposed electrode show good ability to discriminate iodide over several inorganic and organic anions.

The electrode was successfully applied to direct determination of iodide in synthetic mixture, waste water and drinking water, and pharmaceutical samples in addition to applying as indicator electrode in precipitation titration.  相似文献   

13.
《Analytical letters》2012,45(6):881-897
Abstract

The preparation and electrochemical characterization of a carbon composite electrode modified with copper(II)-resin as well as its behavior toward rutin were investigated using cyclic and linear sweep voltammetry. The best voltammetric response was observed for a composite composition of 20% (m/m) copper(II)-resin, 0.10 mol L?1 KNO3/10?6 mol L?1 HNO3 solution (pH 6.0) as the supporting electrolyte, and a scan rate of 50 mVs?1. A linear voltammetric response for rutin was obtained in the concentration range from 9.90 × 10?7 to 8.07 × 10?6 mol L?1, with a detection limit of 2.65 × 10?8 mol L?1. The proposed electrode was useful for the quality control and routine analysis of rutin in pharmaceutical formulations.  相似文献   

14.
Pt‐nanoparticles were synthesized and introduced into a carbon paste electrode (CPE), and the resulting modified electrode was applied to the anodic stripping voltammetry of copper(II) ions. The synthesized Pt‐nanoparticles were characterized by cyclic voltammetry, scanning electron microscopy and X‐ray photoelectron spectroscopy techniques to confirm the purity and the size of the prepared Pt‐nanoparticles (ca. 20 nm). This incorporated material seems to act as catalysts with preconcentration sites for copper(II) species that enhances the sensitivity of Cu(II) ions to Cu(I) species at a deposition potential of ?0.6 V in an aqueous solution. The experimental conditions, such as, the electrode composition, pH of the solution, pre‐concentration time, were optimized for the determination of Cu(II) ion using as‐prepared electrode. The sensitivity changes on the different binder materials and the presence of surfactants in the test solution. The interference effect of the coexisted metals were also investigated. In the presence of surfactants, especially TritonX‐100, the Cu(II) detection limit was lowered to 3.9×10?9 M. However, the Pt‐nanoparticle modified CPE begins to degrade when the period of deposition exceeds to 10 min. Linear response for copper(II) was found in the concentration range between 3.9×10?8 M and 1.6×10?6 M, with an estimated detection limit of 1.6×10?8 M (1.0 ppb) and relative standard deviation was 4.2% (n=5).  相似文献   

15.
A highly selective polyvinylchloride (PVC) membrane electrode based on Schiff base complex i.e. [Cobalt (Salpen) (PBu3)] ClO4 · H2O (Salpen = bis(salycilaldehyde)propylene diamine) is reported as new carrier for thiocyanate selective electrode by incorporating the membrane ingredients on the surface of graphite electrodes. The proposed electrode possesses a very wide Nernestian linear range to thiocyanate from 1.0 × 10?6 to 1.0 × 10?1 M with slope of ?59.05 ± 0.91 mV per decade of thiocyanate concentration, very low detection limit (8.0 × 10?7 M) and good thiocyanate selectivity over the wide variety of other anions. Fast and stable response, good reproducibility, long-term stability, applicability over a wide pH range (2.8–9.8) are advantages of the reported electrode. The sensor has a response time of <5 s and can be used for at least 14 weeks without any considerable change in respective potential response. The proposed electrode was used for the determination of thiocyanate in saliva, wastewater and human urine with satisfactory results and good agreement with colorimetric as reference method.  相似文献   

16.
Studies on complex formation of tris(3‐(2‐hydroxybenzophenone)propyl)amine (THPA) with a number of metal ions in acetonitrile solution revealed the occurrence of a selective 1 : 1 complexation of the proposed ligand with Sn2+ ion. Consequently, THPA was used as a suitable neutral ionophore for the preparation of a polymeric membrane‐selective electrode. The electrode exhibits a Nernstian behavior with a slope of 29.4±0.3 mV per decade and a detection limit of 2.0×10?7 M. It also showed a good selectivity for Sn2+ ions in comparison with some of group A and B metal ions over a wide concentration range of 5.0×10?7–1.0×10?1 M. Improved selectivity was achieved compared to the best selectivity recently reported by other authors for tin(II). The electrode was successfully applied to the determination of Sn2+ ion in waste water and various canned products.  相似文献   

17.
《Analytical letters》2012,45(15):2444-2459
Abstract

Polymeric membrane electrodes (PMEs) and coated graphite electrodes (CGEs) containing 1,3,4-trisubstituted-2-azetidinone derivatives as ion carriers are reported here for bismuth(III) ion selectivity. These electrodes exhibited Nernstian response for Bi3+ ions over a wide concentration range (5.0 × 10?7 M to 1.0 × 10?1 M for CGE) with a lower detection limit of 3.98 × 10?7 M (for CGE) and wide pH range (1.3–5.0). Compared to polymeric membrane electrode, the coated graphite electrode has shown better selectivity for Bi3+ ions with respect to common metal ions. Proposed electrodes have been used for the estimation of Bi3+ ions in pharmaceutical and glass samples.  相似文献   

18.
《Analytical letters》2012,45(6):1451-1457
Abstract

A new heterogeneous Mn(II) ion selective coated wire electrode (CWISE) based on tetrapyridine Mn(II) thiocynanate as electroactive material has been described. the working pH range of the electrode is 2.3 to 8.8. the electrode shows a linear response in the concentration range 1.0×10?1M to 1.0×10?6M. the response time of the electrode is 35 sec. the selectivity coefficient for different cations determined by mixed solution method are:

Fe2+(0.05), Cd2+(0.05), Ni2+(0.01), Co2+(0.5), Pb2+(0.5), Hg2+(0.05), Sn2+(0), Zn2+(0)

The electrode can be used for the electrometeric determination of Mn(II) ion.  相似文献   

19.
《Analytical letters》2012,45(2):284-297
Abstract

4-(2-Thiazolylazo)resorcinol (TR) was used as a new compound to play the role of an excellent ion carrier in the fabrication of an Er(III) membrane electrode. The electrode shows a very good selectivity toward Er(III) ions over a wide variety of cations, including alkali, alkaline earth, transition, and heavy-metal ions. The proposed sensor exhibits a Nernstian behavior (with slope of 19.6 ± 0.6 mV per decade) over a wide concentration range (1.0 × 10?6 to 1.0 × 10?2 M). The detection limit of the sensor is 6.6 × 10?7 M. It has a very short response time, in the whole concentration range (~10 s), and can be used for at least 12 weeks in the pH range of 2.8–9.3. The proposed sensor was successfully applied as an indicator electrode for the potentiometric titration of a Er(III) solution, with EDTA. It was also successfully applied to the F? ion determination in some mouthwashing solutions.  相似文献   

20.
The Cu (II) imprinted polymer glassy carbon electrode (GCE/Cu-IP) was prepared by electropolymerization of pyrrole at GCE in the presence of methyl red as a dopant and then imprinting by Cu2+ ions. This electrode was applied for potentiometric and voltammetric detection of Cu2+ ion. The potentiometric response of the electrode was linear within the Cu2+ concentration range of 3.9 × 10?6 to 5.0 × 10?2 M with a near-Nernstian slope of 29.0 mV decade?1 and a detection limit of 5.0 × 10?7 M. The electrode was also used for preconcentration anodic stripping voltammetry and results exhibited that peak currents for the incorporated copper species were dependent on the metal ion concentration in the range of 1.0 × 10?8 to 1.0 × 10?3 M and detection limit was 6.5 × 10?9 M. Also the selectivity of the prepared electrode was investigated. The imprinted polymer electrode was used for the successful assay of copper in two standard reference material samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号