首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A stripping method for the determination of single‐stranded DNA in presence of copper at the submicromolar concentration levels is described. The method is based on controlled adsorptive accumulation of adenine (from acid‐treated DNA) at thin‐film mercury electrode followed by linear scan voltammetry measurement of the surface species. Optimum experimental conditions were found to be the use of a 5.0×10?3 M NaOH solution, an accumulation potential of ?0.40 V and a scan rate of 200 mV s?1. The response of adenine–copper is linear over the concentration range 50–250 ppb. For an accumulation time of 15 minutes, the detection limit was found to be 4 ppb. The more convenient relation to measuring the ssDNA in presence of metals and nitrogenated bases were also investigated. The utility of the method is demonstrated by the presence of adenosine‐triphosphate (ATP) and amino acids.  相似文献   

2.
Highly sensitive, simple and inexpensive techniques of adenine determination are particularly interesting in relation to the present development of ATP and DNA sensors. A nanomolar concentration of adenine can be determined in the presence of copper. For an accumulation time of 30 minutes, the detection limit found was 0.22 ppb (1.63×10?9 M). The method is based on controlled adsorptive accumulation of adenine‐copper at thin‐film mercury electrode followed by linear scan voltammetric measurement of the surface species. By applying a condition time of 60 s at ?0.9 V, the same thin‐film can be used over several measurements. Optimum experimental conditions were found to be the use of a 5.0×10?3 M NaOH solution, an accumulation potential over the ?0.20 to ?0.40 V range, and a scan rate of 100 mV s?1. The response of adenine‐copper is linear over the concentration range 20–100 ppb. The more convenient ways to measuring adenine in the presence of metals and other nitrogenated bases were also investigated. The adenosine triphosphate (ATP) or deoxyribonucleic acid (DNA) are first treated with acid (e.g., 0.1 M perchloric acid), and the acid‐released adenine (without separation from others products of the degradation) is directly determined by adsorptive stripping voltammetry.  相似文献   

3.
《Analytical letters》2012,45(13):2011-2025
Abstract

A stripping method for the determination of xanthine at the submicromolar concentration level is described. The method is based on controlled adsorptive accumulation of xanthine at a thin-film mercury electrode followed by a linear scan voltammetry measurement of the surface species. Optimum experimental conditions were found to be the use of a 5.0 × 10?3 M NaOH solution, an accumulation potential of 0.00 V, and a scan rate of 20 mV s?1. The response of xanthine is linear over the concentration range 20–140 ppb. For an accumulation time of 30 min, the detection limit was found to be 36 ppt (2.3 × 10?10 M). The more convenient relations for measuring xanthine in the presence of the metals, hypoxanthine, amino acids, and other nitrogenated bases were also investigated. The utility of the method is demonstrated by the presence of xanthine in adenosine-5′-triphosphate or DNA.  相似文献   

4.
《Analytical letters》2012,45(10):2032-2044
Abstract

A stripping method for the determination of cysteine in the presence of copper at the submicromolar concentration levels is described. The method is based on controlled adsorptive accumulation of cysteine at mercury film electrode followed by linear cyclic voltammetry scan measurement of the surface species. Optimum experimental conditions were found to be the use of a 1×10?3 M NaOH solution, an accumulation potential of ?0.50 V and a scan rate of 200 mV. s?1. The response of cysteine is linear over the concentration range 0.04–0.20 ppm. For an accumulation time of 15 minutes, the detection limit was found to be 0.9 ppb (7.4×10?9 M). The more convenient relation to measuring the cysteine in presence of metals, and others amino acids were also investigated. The utility of the method is demonstrated by presence of casein and ATP.  相似文献   

5.
《Analytical letters》2012,45(10):1593-1603
This article reports a new simple and sensitive method for the determination of folic acid by adsorptive stripping voltammetry. The method is based on the accumulation of folic acid at a bismuth film plated in situ on a glassy carbon substrate. In order to stabilize bismuth ions, sodium potassium tartrate was added to the supporting electrolyte. The bismuth film formation and folic acid accumulation conditions were optimized and measurements were carried without solution deaeration. The calibration graph was linear from 5 × 10?10 to 2 × 10?8 mole per liter with an accumulation time of 180 seconds with a limit of detection of 2 × 10?10 mole per liter. The relative standard deviation for 5 × 10?9 mole per liter of folic acid was 3.1 percent (n = 5). The method was successfully applied for determination of folic acid in pharmaceutical preparations.  相似文献   

6.
固态汞合金电极吸附伏安法测定酪氨酸   总被引:1,自引:0,他引:1  
采用白合金粉与汞混合制成汞合金糊,涂布在固体石蜡碳糊电极表面,固化后制得固态汞合金电极,并首先应用于酪氨酸的测定。在含Co2 的pH 9.2的硼砂-NaOH底液中,用线性扫描伏安法在-0.80~-1.30V范围内进行扫描,酪氨酸于-1.05 V出现灵敏的还原峰,酪氨酸的浓度与峰电流在1.0×10-7~1.0×10-5mol/L范围内呈线性关系。该法已用于复方氨基酸注射液中酪氨酸含量的测定,加标回收率达96%~102%。该电极既保留了汞电极的优点,又避免了汞电极有毒、使用不方便的缺点。  相似文献   

7.
This paper reports the electrochemical properties of sulpiride at a mercury electrode,especially its adsorptive characteristic,Sulpiride dissolved in a supporting electrolyte of a McIlvaine buffer at pH 6.8 represents a sensitive and well defined reduction wave by linear sweep stripping voltammetry.This method is based on the pre-concentration and the reduction of sulpiride at a hung mercury drop electrode.The reduction peak potential is -1.72V(vs.Ag-AgCl) and the peak current is proportional to the concentration of sulpiride in the range of 0.1-0.6 μg/mL.The detection limit is 0.0250μg/mL obtained under the experimental conditions selected in this work.The electrochemical properties of this system were investigated.and the proposed method was applied to the determination of sulpiride in pharmaceutical tablets with satisfactory results,It was compared well with the UV spectrophotometric method,showing a superior sensitivity.  相似文献   

8.
《Analytical letters》2012,45(19):2141-2157
Abstract

A technique is presented for the determination of trace concentrations of copper (II) in natural water samples by cathodic stripping voltammetry of a film of copper-catechol complex ions adsorbed on the hanging mercury drop electrode. The peak height of the copper-catechol reduction peak is linearly dependent upon the copper (II) concentration between 10?10 and 10?7 M. The detection limit of the technique is below 10?10 M copper (II) for a collection time of 3 minutes, but the sensitivity can be further increased four-fold by collecting for 15 minutes. The sensitivity is reduced by high concentrations of competing trace metals and of surfactants, which necessitate the use of standard additions to the sample.  相似文献   

9.
阴极溶出伏安法测定异烟肼的研究   总被引:1,自引:0,他引:1  
报道了吸附阴极溶出伏安法测定异烟肼。探讨了电极反应机理。在0.01mgol/L硼砂底液中,峰电位为-1.40V。峰电流与异烟肼浓度在4.0*10^-7-1.5*10^-5mol/L范围内呈良好的线性关系,相关系为0.9913。该方法用于异烟肼片剂的测定,获得满意结果。  相似文献   

10.
An electrochemical adsorptive stripping approach is presented for the trace measurement of copper in some real samples. The method is based on the reduction of Cu2+ at pH 5.5 calcein blue (CB) containing solution at ?250 mV (vs. Ag/AgCl), adsorption of Cu? CB complex on hanging mercury drop electrode (HMDE) and the voltammetric determination by further reduction to Cu+ at HMDE. Experimental optimum conditions were determined in the fundamental studies. At the experimental optimum conditions the adsorbed complex of Cu2+ and calcein blue gives a well defined cathodic stripping peak current at ?0.135 V, which has been used for the determination of copper in the concentration range of 0.02 to 15 ng/mL with accumulation time of 90 s. The relative standard deviation (RSD) for the determination of 0.5 and 6.0 ng mL?1 were 2.60 and 1.94% respectively. (n=10). The method has been applied to the analysis of copper in analytical reagent grade salts and tap water, mineral water and drug samples with satisfactory results.  相似文献   

11.
《Analytical letters》2012,45(3):465-478
ABSTRACT

A technique is presented for the determination of trace amounts of copper(II) by adsorptive cathodic stripping voltammetry. The procedure is based on adsorptive accumulation of copper(II)-Alizarin Red S (ARS) complex on a hanging mercury drop electrode, followed by a stripping voltammetric measurement of the reduction current of the adsorbed complex at -0.16 V (vs. Ag/AgCl). The height of the copper -ARS reduction peak is linearly dependent upon the copper(II) concentration between 0.2-15 and 15-500 ng.ml?1. The detection limit of the technique is 0.05 ng.ml?1 copper(II) for a collection time of 1 minute. The method is free from most interferences. The procedure has been successfully applied to the determination of trace amounts of copper(II) in some analytical grade salts.  相似文献   

12.
《Analytical letters》2012,45(15):2965-2975
ABSTRACT

Albendazole is determined by differential-pulse adsorptive cathodic stripping voltammetry at a hanging mercury drop electrode using the reduction peak of its copper(II) complex at ?0.28V at an accumulation potential 0.0V vs. Ag/AgCl electrode. The optimum conditions of pH, accumulation potential and accumulation time were studied. The calibration graph for the determination of albendazole was linear in the range 3.0X10?8 - 9X10?7M with a relative standard deviation of 2.8%. The detection limit was 1.0X10?8M after 180s accumulation at 0.0V. The effect of common excipients and metal ions on the peak height of albendazole was studied. The presence of Cu2+ ions forms a stable complex with albendazole which is strongly adsorbed at the mercury electrode surface. The method was applied to the determination of the drug in commercially available dosage forms.  相似文献   

13.
槲皮素化学修饰碳糊电极吸附溶出伏安法测定痕量铅   总被引:14,自引:0,他引:14  
建立了用槲皮素修饰碳糊电极测定痕量铅的新方法 ,在 0 .1 0mol L甲酸盐缓冲液 (pH 4.3 )中 ,于 -0 .1 0V(vs.SCE)搅拌富集 ,再在 -0 .70V静止还原 40s后 ,阳极化扫描 ,于 -0 .42V左右获得一灵敏的铅阳极溶出峰。在最佳条件下 ,富集不同时间 ,其二次导数峰电流与Pb2 + 在 1 .0× 1 0 - 8~ 8.0× 1 0 - 7mol L和 2 .0× 1 0 - 9~ 6.0× 1 0 - 8mol L两个范围内呈线性关系 ,检出限为 8.0× 1 0 - 1 0 mol L(S N =3 )。同时初步探讨了电极反应机理。  相似文献   

14.
A new method using differential pulse adsorptive stripping voltammetry for the determination of atrazine (ATZ) in natural water samples using a bismuth film electrode (BiFE) is proposed. The calibration curve was linear in the atrazine concentration range from 6.7×10?7 to 2.0×10?5 mol L?1, with a limit of detection (LOD) of 1.4×10?7 mol L?1. The proposed electrode was applied for atrazine determination with satisfactory results compared with a high‐performance liquid chromatography method (HPLC).  相似文献   

15.
Traces of copper(II) can be determined by adsorptive stripping voltammetry using 2‐carboxy‐2′‐hydroxy‐5′‐sulfoformazyl benzene (Zincon) as complex forming reagent. First in phosphate buffer pH 6.4, copper(II)‐Zincon complex was adsorbed on carbon paste electrode (CPE) with an accumulation potential of 0.6 V. Following this, adsorbed complex was oxidized and detected by differential pulse voltammetric (DPV) scan from 0.6 to 1.0 V. The effective parameters in sensor response were examined. The detection limit (DL) of copper(II) was 1.1 μg/L and relative standard deviations (RSDs) for 10 and 200 μg/L Cu(II) were 1.81 and 1.03%, respectively. The calibration curve was linear for 2–220 μg/L copper(II). The resulting CPE does not use mercury and therefore, has a positive environmental benefit. The method, which is reasonably sensitive and selective, has been successfully applied to the determination of trace amount of copper in water and human hair samples.  相似文献   

16.
张玉涛  米雪迎 《分析化学》1994,22(7):675-678
本文提出了碳纤维束汞膜电极二次微分阳极溶出伏安法测定锌中微量铅的方法,对溶解氧,扫描速度,电极清洗时间,富集电位和时间及酸度的影响作了讨论。方法的线性范围为1.9-80μg/L;检测下限达到1.9μg/L;对国家保证参考物质锌样中铅的测定,相对标准偏差和相对误差分别为2.6%和0.65%,结果令人满意。  相似文献   

17.
 A sensitive method for the determination of amitraz pesticide at nanomolar level by adsorptive stripping voltammetry at a hanging mercury drop electrode is described. The cyclic voltammograms demonstrate the adsorption of this compound on the mercury electrode. A systematic study of the various experimental parameters, that affect the stripping response, was carried out by differential pulse voltammetry. Using an accumulation potential of −0.50 V, and 30 s accumulation time, the limit of detection was found to be 2.3 × 10−9 mol L−1 and the relative standard deviations (n = 5) was 2.2% at concentration level of 5.0 × 10−8 mol L−1 of amitraz. The influence of diverse ions and some other pesticides was investigated. Finally, the method was applied to the determination of amitraz in spiked soil and water. The relative standard deviation is 4.5% for 5 determinations of amitraz in water and 3.2% for 5 determinations in soil. Received December 6, 2000. Revision March 1, 2001.  相似文献   

18.
Robert Piech 《Electroanalysis》2008,20(22):2475-2481
The new cyclic renewable mercury film silver based electrode (Hg(Ag)FE), applied for the determination of selenium(IV) traces in the presence of copper ions using differential pulse cathodic stripping voltammetry (DP CSV) is presented. The preparation of the Hg(Ag)FE is very simple. The effects of various factors such as: preconcentration potential and time, pulse height, step potential and supporting electrolyte composition are optimized. The calibration graph is linear from 0.5 nM (39 ng L?1) to 100 nM (7.9 μg L?1) for a preconcentration time of 45 s, with correlation coefficient of 0.9995. For a Hg(Ag)FE with a surface area of 8 mm2 the detection limit for a preconcentration time of 90 s is as low as 17 ng L?1. The repeatability of the method at a concentration level of the analyte as low as 2 μg L?1, expressed as RSD is 2.7% (n=7). The proposed method was successfully applied and validated by studying the certified reference material (bovine liver BCR‐185) and simultaneously recovery of Se(IV) from spiked water samples.  相似文献   

19.
刘宁高伟  宋俊峰 《中国化学》2006,24(11):1657-1661
Voltammetry using solid electrodes usually suffers from the contamination due to the deposition of the redox products of analytes on the electrode surface. The contamination has resulted in poor reproducibility and overelaborate operation procedures. The use of the chemical catalysis of oxidant on the reduction product of analyte not only can eliminate the contamination of analyte to solid electrodes but also can improve the faradaic response of analyte. This work introduced both the catalysis of oxidant K2S2O8 and the enhancement of surfactant Triton X-100 on the faraday response of amiodarone into an adsorptive stripping voltammetry at a carbon paste electrode for the determination of amiodarone. The method exhibits high sensitivity, good reproducibility and simple operation procedure. In 0.2 mol·L^-1 HOAc-NaOAc buffer (pH=5.3) containing 2.2×10^-2 mol·L^-1 K2S2O8 and 0.002% Triton X-100, the 2.5th-order derivative stripping peak current of the catalytic wave at 0.3 V (vs. Ag/AgCl) is rectilinear to amiodarone concentration in the range of 2.0×10^-10-2.3×10^-8 mol·L^-1 with a detection limit of 1.5×10^-10 mol·L^-1 after accumulation at 0 V for 30 s.  相似文献   

20.
本文建立了在铋膜修饰电极上采用方波吸附溶出伏安法同时测定纺织品中痕量Co2+和Ni2+的方法.以NH3-NH4Cl作为缓冲液,在丁二酮肟浓度为10 μmol/L的体系中,Co2和Ni2+的还原峰电位分别为-1.13 V和-1.03 V.当缓冲溶液pH为9.2,富集电位为-0.7V,富集时间为200 s时,C02 +和Ni2+在0.5~50 μg/L范围呈现良好的线性关系,相关系数R2>0.99,其检出限分别为0.79 μg/L和0.96 μg/L,其它金属离子的干扰较小.采用标准加入法测定纺织品中Co>和Ni2+,回收率在94.88%~104.14%之间.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号