首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
This study reports the synthesis of water soluble iron(II) phthalocyanine and a facile method for spectrophotometric determination of Hg(II) in environmental water samples by ionic liquid based dispersive liquid–liquid microextraction (IL-DLLME). In the method, 1-heptyl-3-methylimidazolium hexafluorophosphate (250 µL) as extraction solvent, acetonitrile (750 µL) as dispersive solvent and Triton X-100 (200 µL) as anti-sticking agent were used. After the extraction of the Hg(II) complex (Hg(II):q-Fe(II)-Pc) into thin droplets of ionic liquid, the sample was centrifuged for 4 min at 2000 rpm. The upper aqueous phase was removed and the residue diluted to 250 µL with methanol and transferred to a 250 µL cell for spectrophotometric detection at 280 nm. The linear range of the method is 0.05–1 µg/mL. The limits of detection and quantification is 0.01 and 0.03 µg/mL, respectively. The RSD for the developed method was calculated as 0.78% at 0.50 µg/mL Hg(II).  相似文献   

2.
ABSTRACT

A simple and reliable analytical method using instrumentation available in most of the laboratories has been developed for the separation and determination of silver nanoparticles in water samples. Cloud point extraction (CPE) was used for the separation of silver nanoparticles (AgNPs) from the sample and these nanoparticles were then determined by electrothermal atomic absorption spectrometry (ETAAS). Parameters related to the cloud point extraction procedure (Triton X-114 concentration, type of complexing agent (EDTA or Na2S2O3), pH, incubation temperature, incubation and centrifugation time) were selected using a multivariate approach (designs of experiments); 8.6% (v/v) Triton X-114, 750 µL saturated EDTA and pH 7 were selected as the optimum conditions. Calibration standards in a concentration range from 0 to 10 µg L?1 of AgNPs were subjected to the CPE procedure to obtain quantitative recoveries. The LOD and LOQ were 0.04 and 0.13 µg L?1, respectively. The method is selective for the extraction of AgNPs, and ionic Ag remains in the aqueous phase. Single particle inductively coupled plasma mass spectrometry (SP-ICP-MS) was used to evaluate the effect of the CPE procedure in particle size, and no changes were observed. Finally, the procedure was applied to wastewater samples spiked with nanoparticles with quantitative recoveries.  相似文献   

3.
《Analytical letters》2012,45(14):1593-1605
Abstract

A simple but reliable method for the determination of aluminum in serum by flameless atomic absorption spectrometry is described. By use of the Zeeman background correction, the interferences are eliminated. However, considering the numerous possible sources of contamination, extreme precautions are necessary both when taking and storing the serum. The procedures preceding the dosage per se must be minimized. The within-day and clay-to-day precision data (CV %) was 3.28 and 3.82 respectively. The average recovery for aluminum was 97.5 %. We used this method on serum from 30 healthy subjects and from 300 patients on hemodialysis. The mean aluminum concentration for the healthy subjects was 5.35 μg/l (SD ± 0.53) while the values for the hemodialyzed patients ranged from 20 to 220 μg/l.  相似文献   

4.
After human urine or serum was diluted (1 + 9) with HNO3 (0.2%, v/v) and standard additions of Se solution (100 μ L?1), the diluted sample (10 μL) was introduced into the graphite cuvette. The matrix modifier [10μL, containing Pd (0.6 μg) + Ni (25 μg) + NH4NO3 (80 μg) in HNO3 (0.2%, v/v) for urine, or Pd (0.3 μg) + Ni (30 μg) + NH4NO3 (80 μg) + Triton X-100 (0.04%) in HNO3 (0.2%, v/v) for serum, respectively] was added and the mixture was heated according to a temperature program. The matrix modifier containing NH4NO3 in a suitable amount and a small amount of Pd enhanced the sensitivity for Se. The method detection limits (3σ) after dilution were about 4.9 ± 0.8 and 2.36 ± 0.18 μg L?1 for urine and serum, respectively. The accuracy of this method was tested with SRM #2670 human urine Se and Seronorm Trace Elements #116 human serum Se, respectively, and the results of 97.6 – 101% and 100 – 104% were obtained with precision ± 0.3% and ± 2%, respectively. This method can be applied easily and accurately to the determination of concentration of total Se in human urine and serum.  相似文献   

5.
《Analytical letters》2012,45(11):1662-1677
Abstract

To measure the different activity of chromium(VI) and chromium(III) in soil samples, chromium(VI) and total chromium (CrVI + CrIII) was extracted by KCl extracting agent and alkali fusion, respectively. Cloud point extraction (CPE) for speciation determination of chromium with double-slotted quartz tube atom trap–flame atomic absorption spectrometry (STAT-FAAS) was developed. Preconcentration of chromium(VI) and total chromium in different pH solutions was achieved by CPE, with ammonium pyrrolidine dithiocarbamate (APDC) as the chelating agent and Triton X-114 as the cloud point extractant. The conditions of CPE and determination were studied. Under the optimal conditions, the enrichment factor was 50 for chromium from the initial 100-mL sample solution to the final 2-mL determined solution. Compared to the FAAS method, the sensitivity was improved seven-fold for chromium by the STAT-FAAS method. The limit of detection was 0.082 µg/L for chromium.  相似文献   

6.
《Analytical letters》2012,45(10):2205-2215
Abstract

Meso‐stilbenediamine has been used as derivatizing reagent for liquid chromatographic (LC) determination of glyoxal (Go), methylglyoxal (MGo), and dimethylglyoxal (DMGo) at pH 3. Liquid chromatographic elution and separation was carried out from the column Kromasil 100 C‐18, 5 µm (15×0.46 mm i.d.) with methanol: water:acetonitrile (59:40:1, v/v/v) with a flow rate of 1 mL/min and ultraviolet detection at 254 nm. The linear calibration curves were obtained for Go, MGo, and DMGo within 0.97–4.86 µg/mL, 1.52–7.6 µg/mL, and 1.41–7.08 µg/mL with detection limits of 48 ng/mL, 76 ng/mL, and 70.8 ng/mL, respectively. The method was applied for the determination of Go and MGo from serum of patients suffering from diabetes and ketosis. The amounts of Go and MGo found were 0.150–0.260 µg/mL and 0.160–0.270 µg/mL with coefficient of variation (C.V.) 2.6–4.7% and 2.5–4.6%, respectively. The results obtained were compared with normal subjects with Go and MGo contents of 0.025–0.065 µg/mL and 0.030–0.070 µg/mL with C.V 1.5–4.9% and 1.6–4.8% in the serum.  相似文献   

7.
《Analytical letters》2012,45(9):1853-1864
Abstract

A new method based on the cloud point extraction (CPE) separation and ultraviolet spectrometry determination was proposed for the determination of albumin. When the system temperature is higher than the cloud point extraction temperature (CPT) of the mixed surfactant of p‐octyl polyethyleneglycolphenyether (Triton X‐100) and sodium dodecyl sulfate (SDS), serum albumin could be extracted into surfactant‐rich phase. The main factors affecting the cloud point extraction were investigated systematically. Under the optimized conditions, the determination limit for serum albumin as low as 0.18 µg/mL was obtained by preconcentrating a 10 mL sample solution, and the relative standard deviation (n=10, c=40.0 µg/mL) was 3.77%. The proposed method was applied to the determination of albumin in serum samples. The results obtained by this method were in good agreement with coomassie brilliant blue (CBB).  相似文献   

8.
《Analytical letters》2012,45(9):1615-1622
Abstract

A simple and rapid method for the simultaneous determination of seven trace elements in biodiesel by axial and radial view Inductively Coupled Plasma Optical Emission Spectrometry (ICP OES) is proposed, in which the sample is emulsified with Triton X-100 and water, and in which yttrium is employed as an internal standard. The better obtained quantification limits (10 s) were by axial view, 0.165, 0.099, 0.033, 0.007, 0.016, 0.132, 0.660 µg g?1 for Ca, Cu, Fe, Mg, Mn, Na, and P, respectively, based on a sample mass of 1.0 g diluted to a final mass of 10 g in the analytical solution. Calibration was carried out with aqueous standards, thus avoiding the use of frequently instable organic standards. Elemental recoveries were in the range of 90 to 109% for all seven analytes studied, and also the precision of the method was satisfactory (RSD < 8%).  相似文献   

9.
A practical procedure was developed for detecting nonylphenol ethoxylates (NPEOs) and octylphenol ethoxylates (OPEOs) in household detergents by gas chromatography–mass spectrometry (GC–MS) with the introduction of a cleavage technique using aluminum iodide (AlI3) to convert NPEOs and OPEOs to their parent nonylphenol and octylphenol. The reliability of the cleavage process was evaluated using Igepal-210, Triton X-15, Tergitol NP-9, and Triton X-100 as substrates, demonstrating satisfactory efficiency. The effect of the sample matrix on the cleavage process was investigated, and the optimized dose of AlI3 was estimated. The major advantage of this method is the use of a common analytical tool (GC–MS) for accurate monitoring of APEOs after elimination of the ethoxylate chain, with detection limits of 12.5 mg/kg and 5.0 mg/kg for NPEO9 and OPEO9, respectively. Analytical results revealed that NPEOs and OPEOs were found in 12.6 % of 182 household detergents in the concentration range of 18–800 mg/kg.  相似文献   

10.
An ultrasound-assisted cloud point extraction (CPE) procedure was used for preconcentration and determination of vanadium by graphite furnace atomic absorption spectrometry. The vanadyl(IV) complex with ascorbic acid form a hydrophobic complex with 4-(2-pyridylazo) resorcinol (PAR) in a micelle medium, which is stable under our working conditions, and followed by its extraction into Triton X-100 surfactant-rich phase. The main factors affecting CPE efficiency, such as pH, concentrations of PAR, ascorbic acid and Triton X-100, incubation temperature, frequency and equilibration time of ultrasonic bath were investigated in detail. Under the optimum conditions, preconcentration of 10 mL sample gave a preconcentration factor of 36.4 and a detection limit of 4.0 µg kg?1. The proposed method was successfully applied to determination of vanadium in sea cucumbers with satisfactory results.  相似文献   

11.
A novel fluorescent chemosensor of the derivatives of calix[4]arene (SAX) for Congo red (CR) in methyl-β-cyclodextrin/Triton X-100 synergistic sensitized system was developed. The results showed that the fluorescence intensity of SAX could be quenched by CR, and the fluorescence quenching (?F?=?FSAX ? FCR-SAX) was synergistic sensitized by methyl-β-CD and Triton X-100. Under the conditions of λex/em?=?332/468 nm and pH 7.5, the linear range and the detection limit for CR were found to be 0.040–8.0 μg/mL and 8.9 ng/mL, respectively. The mechanism of determination was discussed by quenching type analysis and sensitizing effect. This method has also been applied for the determination of CR in beef samples with satisfactory results.  相似文献   

12.
《Analytical letters》2012,45(18):2894-2907
A heating procedure is reported with slurry sampling electrothermal atomic absorption spectrometry to improve the accuracy of cadmium determination in food. In comparison to conventional slurry sampling, the heating significantly increased cadmium recovery and improved the precision. For the optimized procedure, 25–250 mg of food were treated with 2% HNO3 and 1% H2O2 with heating at 120°C for 20 min, followed by the addition of 50 µL of 10% Triton X-100, and homogenization in an ultrasonic bath prior to analysis. Tungsten and rhodium were employed as a permanent modifier with optimum pyrolysis and atomization temperatures of 500°C and 1500°C. Calibration with aqueous standards resulted in good agreement between certified or information values and measured results at the 95% confidence level. A characteristic mass of 0.8 ± 0.1 pg and a detection limit of 0.7 ng g?1 for a 2% slurry were obtained. The method was employed for the direct determination of cadmium in food certified reference materials.  相似文献   

13.
A simple and elegant electrochemical potentiostatic method has been described for the preparation of highly stable and electrocatalytically active bismuth nanoribbons (BiNRs). The average length and width of the BiNRs were of 100±50 nm and 10±5 µm, respectively. Here, disodium ethylene diamine tetraacetate was employed as a scaffold for the growth of BiNRs. The formation of BiNRs was confirmed by surface morphological, elemental and cyclic voltammetric analyses. The BiNRs exhibited excellent electrocatalytic ability in detecting biologically poisoning heavy metal ions such as lead and cadmium. The described BiNRs based sensor presents good linear dependence on lead and cadmium ions in the concentration range of 1–50 µg/L for both metal ions with a detection limit of 0.104 µg/L for lead and 0.145 µg/L for cadmium.  相似文献   

14.
Cloud point extraction was applied as a preconcentration step for the determination of trace level of Al(III) in water samples with electrothermal atomic absorption spectrometry (ETAAS), flame atomic absorption spectrometry (FAAS) and UV-visible spectrophotometry. The aluminum was extracted as aluminum-Eriochrome Cyanine R (ECR) complex, at pH 6 by micelles of the non-ionic surfactant octylphenoxypolyethoxyethanol (Triton X-114). The investigations showed that the same CPE procedure can be used for different detection techniques. The results obtained from these techniques were evaluated. Under the optimal conditions, limit of detection obtained with ETAAS, FAAS and UV-visible spectrophotometry were 0.03 ng mL?1, 0.06 µg mL?1 and 0.01 µg mL?1, respectively. The accuracy of the procedure was tested by analysing certified reference material. The method was successfully applied to determination of aluminum in water samples and dialysis fluid.  相似文献   

15.
《Analytical letters》2012,45(11):1975-1987
Abstract

Butylidenephthalide is one of the major active components isolated from Rhizoma Chuanxiong. This paper describes a simple, rapid, specific and sensitive method for the quantification of butylidenephthalide in rat plasma and tissue distribution using a liquid-liquid extraction procedure followed by capillary gas chromatography-selected ion monitoring mode-mass spectrometry (GC-SIM-MS) analysis. The calibration curves were linear over the concentration ranging from 0.02–10.0 µg/mL (r > 0.99) for plasma samples and 0.18–7.25 µg/g (r > 0.99) for the tissue samples. The limit of quantification (LOQ) was 1.0 ng/mL or 1.0 ng/g (ten times signal/noise ratio). Within- and between-day precisions expressed as the relative standard deviation (RSD) for the method were 2.39–2.98% and 2.97–4.26%, respectively. The methods of recovery for all samples were greater than 80% at the low, medium, and high concentrations. The method has been successfully applied to a pharmacokinetics study in rats after an oral administration of Butylidenephthalide with a dose of 20.0 mg/kg. The main pharmacokinetic parameters obtained were T max  = (0.22 ± 0.06) h, C max = (3 ± 1) µg/mL, AUC = (32 ± 6) h?µg/mL, and K a  = (8.5 ± 0.8)/h. The results showed that the butylidenephthalide was easily absorbed. The concentrations of butylidenephthalide in rat kidney, lung, heart, and cerebellum were higher than those in other organs. To determine free fraction in serum, samples were filtered using ultrafiltration membranes with a molecular weight cut-off of 10,000 Da and extracted using liquid-liquid extraction. The extracts were evaporated and analyzed by GC-MS. The protein binding in rat plasma, human plasma, and human serum albumin were 83 ± 4%, 94 ± 3%, and 89 ± 3%, respectively.  相似文献   

16.
《Analytical letters》2012,45(9):1547-1554
Abstract

One method using a solid sampling device for the direct determination of Cr and Ni in fresh and used lubricating oils by graphite furnace atomic absorption spectrometry are proposed. The high organic content in the samples was minimized using a digestion step at 400°C in combination with an oxidant mixture 1.0% (v v?1) HNO3 + 15% (v v?1) H2O2 + 0.1% (m v?1) Triton X-100 for the in situ digestion. The 3-field mode Zeeman-effect allowed the spectrometer calibration up to 5 ng of Cr and Ni. The quantification limits were 0.86 µg g?1 for Cr and 0.82 µg g?1 for Ni, respectively. The analysis of reference materials showed no statistically significant difference between the recommended values and those obtained by the proposed methods.  相似文献   

17.
《Analytical letters》2012,45(14):2141-2156
Abstract

Two independent and sensitive ion chromatographic methods with suppressed conductivity were developed for determination of traces of Cl, Na, and Mg in gadolinium-nitrate. Na-Mg was determined by cation-exchange column after matrix separation, whereas Cl was analyzed without matrix separation by high capacity anion-exchange column. Detection limit for Cl was 0.01 µg mL?1 in sample solution and 1 µg g?1 in solid sample. The reproducibility (100 µL injected) was better than 3%, 3% and 4% at 50, 25 and 50 µg L?1 level for Cl, Na, and Mg respectively. The overall precision was better than ±7% for Na-Mg and ±5% for Cl.  相似文献   

18.
A sensitive and selective solid-phase spectrophotometric method for the determination of trace amounts of Hg(II) cation in water is described. A complex was created with Hg(II) using 2,6-dimethyl-morpholine dithiocarbamate (DMMDTC) to form Hg(II)–(DMMDTC) and this complex was adsorbed onto microcrystalline naphthalene (MN) and then eluted with 5% acetic acid (in ethanol) solution. A preconcentration factor of 187 and a recovery of 95% were observed at pH of 5.0 and for 10 min. of extraction. The separated Hg(II) ions were quantified by using ultraviolet-visible spectrophotometer at 490.0 nm by creating a colored complex with dithizone in Triton X-100 surfactant media. Molar absorptivity and sandell’s sensitivity for the Hg(II)-dithizone were determined as 4.96 × 105 Lmol?1cm?1 and 0.4032 µg cm?2, respectively. The detection limit (LOD) was 1.7 μg L?1 under the optimized conditions of the analytical method.  相似文献   

19.
《Analytical letters》2012,45(14):2463-2474
Abstract

In this paper, 2‐carboxyl‐1‐naphthalthiorhodamine (CNTR) was synthesized, and a new method for the simultaneous determination of palladium, platinum, and rhodium ions as metal‐CNTR chelates was developed using rapid column high performance liquid chromatography combined with on‐line enrichment. The palladium, platinum, and rhodium ions were precolumn derivatized with CNTR to form colored chelates. The Pb‐CNTR, Pt‐CNTR, and Rh‐CNTR chelates could be absorbed onto the front of the enrichment column when they were injected into the injector and sent to the enrichment column (ZORBAX Stable Bound, 4.6×10 mm, 1.8 µm) with a buffer solution of 0.05 mol/L sodium acetate–acetic acid buffer solution (pH 3.5) as mobile phase. After enrichment, and by switching the six ports switching valve, the retained chelates were back‐flushed by mobile phase and traveling towards the analytical column. The separation of these chelates on the analytical column (ZORBAX Stable Bound, 4.6×50 mm, 1.8 µm) was satisfactory with 54% methanol (v/v) in 0.05 mol/L sodium acetate buffer (pH 3.5) containing 1 g/L Triton X‐100 as mobile phase. Palladium, platinum, and rhodium were separated completely within 2 min. The detection limits (S/N=3) of palladium, platinum, and rhodium are 1.4 ng/L, 1.2 ng/L, and 1.8 ng/L, respectively. This method was applied to the determination of palladium, platinum, and rhodium in water, urine, and soil samples with good results.  相似文献   

20.
《Analytical letters》2012,45(17):2769-2779
A sensitive method for simultaneous determination of organic and inorganic mercury species has been developed and is presented in this study. The method is based on complex formation of mercury species with the emetine dithiocarbamate (emetine-CS2) ligand, HPLC separation, and tris(2,2′-bipyridine)ruthenium(III) chemiluminescence detection. The complexation reactions of the mercury species and emetine-CS2 ligand occurred instantaneously upon the addition of emetine-CS2 solution to the solution containing the mercury species. The complete separation of these complexes was achieved using an ODS column with 20 mM NaH2PO4-acetonitrile (52:48, v/v) containing 30 mM NaClO4 as an ion-pair reagent. The calibration graphs of these complexes were linear in the range from 1–100 µg/L. The detection limits were 0.27 µg/L, 0.33 µg/L, 0.39 µg/L, and 0.17 µg/L for methylmercury, ethylmercury, phenylmercury, and the mercury ion, respectively, at a signal-to-noise ratio of 3. The developed technique was validated by analyzing certified reference materials, CRM7402-a (cod fish, NMIJ) and CE464 (tuna fish, ERM), in combination with sonication-assisted acid leaching and liquid-liquid extraction. The emetine-CS2 ligand has been used for extraction, separation, and detection of mercury species. The results determined using the proposed method were in good agreement with the values of the certified reference materials. The MeHg+ and EtHg+ recoveries for the spiked samples were found to be almost 100%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号