首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 121 毫秒
1.
Poly(2-amino-5-(4-pyridinyl)-1,3,4-thiadiazole) (PAPT) modified glassy carbon electrode (GCE) was fabricated and used for the simultaneous determinations of dopamine (DA), uric acid (UA) and nitrite (NO2 ?) in 0.1 mol?L?1 phosphate buffer solution (PBS, pH 5.0) by using cyclic voltammetry and differential pulse voltammetry (DPV) techniques. The results showed that the PAPT modified GCE (PAPT/GCE) not only exhibited electrocatalytic activities towards the oxidation of DA, UA and NO2 ? but also could resolve the overlapped voltammetric signals of DA, UA and NO2 ? at bare GCE into three strong and well-defined oxidation peaks with enhanced current responses. The peak potential separations are 130 mV for DA–UA and 380 mV for UA–NO2 ? using DPV, which are large enough for the simultaneous determinations of DA, UA and NO2 ?. Under the optimal conditions, the anodic peak currents were correspondent linearly to the concentrations of DA, UA and NO2 ? in the ranges of 0.95–380 μmol?L?1, 2.0–1,000 μmol?L?1 and 2.0–1,200 μmol?L?1 for DA, UA and NO2 ?, respectively. The correlation coefficients were 0.9989, 0.9970 and 0.9968, and the detection limits were 0.2, 0.35 and 0.6 μmol?L?1 for DA, UA and NO2 ?, respectively. In 0.1 mol?L?1 PBS pH 5.0, the PAPT film exhibited good electrochemical activity, showing a surface-controlled electrode process with the apparent heterogeneous electron transfer rate constant (k s) of 25.9 s?1 and the charge–transfer coefficient (α) of 0.49, and thus displayed the features of an electrocatalyst. Due to its high sensitivity, good selectivity and stability, the modified electrode had been successfully applied to the determination of analytes in serum and urine samples.  相似文献   

2.
《Analytical letters》2012,45(9):627-640
Abstract

The ultraviolet spectra of aqueous nitrite and nitrate solutions and of binary mixtures were obtained. By using an addition technique and a reference nitrate/nitrite solution it was possible to compensate for the interference caused by the overlapping of the nitrate and nitrite bands, which is normally a limiting factor in the analysis of mixtures of nitrite with large excesses of nitrate. The detection limit was 5 × 10?5 M NO2 ? which corresponded to a minimum detectable amount of 2.3 ppm NO2 ? in the presence of up to 20,000 times greater amount of NO3 ?. The accuracy was ± 0.6% and the standard deviation ± 0. 002.  相似文献   

3.
The poly-glutamic acid modified electrode has been prepared by direct electro-polymerization of D-glutamic acid on the surface of glassy carbon electrode. In pH 4.2, 0.1 mol L?1 HAc-NaAc buffer solution, the film modified electrode exhibited remarkable enhancement effect to the electrochemical responses of ferulic acid. The action mechanism was preliminarily explored. In the range of 2.0 × 10?7 to 1.0 × 10?5 mol L?1, and 1.0 × 10?5 to 3.0 × 10?4 mol L?1, the oxidation peak current has a linear relationship to the concentration, and the detection limit was estimated to be 7.0 × 10?8 mol L?1. This method has been adopted to detect trace amount of ferulic acid in Chinese proprietary medicine, and the recovery was from 97.8 to 102.4%.  相似文献   

4.
A modified carbon paste electrode with SiO2/SnO2/Phosphate/Meldola's blue, SSPMelB, was used to study the electrocatalytic oxidation of ascorbic acid by cyclic voltammetry and chronoamperometry. The adsorbed dye mediates ascorbic acid oxidation at an anodic potential of 0.04 V vs. saturated calomel electrode (SCE) at pH 7.0, in 0.5 mol L?1 solution. The linear range of the sensor is between 4.0×10?7 and 2.0×10?3 mol L?1, with a limit of detection of 4.0×10?7 mol L?1. This novel electrode shows good analytical performance for determination of ascorbic acid in medicine and commercial fruit juice.  相似文献   

5.
Water homolyses upon vacuum-uv excitation into HO* radicals, hydrogen atoms and with lower efficiency, hydrated electrons. These primary species induce a series of reactions partially depleting nitrate and nitrite from aqueous solutions. Depletion rates depend on the presence of dissolved oxygen and temperature. Nitrate, nitrite, peroxynitrite and N2O were identified as reaction products after irradiation of, either, nitrite and nitrate in aqueous solutions. A reaction mechanism is proposed in accord with the experimental facts and with the evidence given in the literature, where NO2 * and NO* are key intermediates. NO3 ?, NO2 ?, NO2 *, NO* O2NO2 ?, ONO2 ? and N2O, seem to be interrelated by many redox reactions and reaction equilibria where pH and the availability of electrons determine their occurrence. The proposed mechanism is supported by a computer program with which the observed experimental behavior could be simulated.  相似文献   

6.
In this study a cobalt film electrodeposited on a copper disk (Ø=3.1 mm) was tested as electrode to measure nitrite ions in raw water. This electrode was able to determine the nitrite ions concentration in nondeaerated synthetic media and in natural water. The electrode reached a detection limit of 0.2 μmol L?1 and has a linear concentration range of 0.4 to 2 μmol L?1 NO2?. The influence of several ions such as NO3?, Cl?, SO42?, Mg2+, HCO3? and NH4+ was also tested. The electrode was used to determine the concentration of nitrite ions in a real sample.  相似文献   

7.
A method for the rapid and sensitive determination of peroxyacetyl nitrate (PAN) in air based on a chemiluminescence reaction with an alkaline solution of luminol in the chemiluminescence aerosol detector is described. The PAN is chromatographically separated from nitrogen dioxide and ozone in a packed column filled with 5 % OV-1 on Chromosorb 30/60 and the eluted PAN is detected via the direct reaction with the luminol solution consisting of 0.002 mol L?1 luminol, 1 vol. % Brij-35 and 0.1 mol L?1 KOH. The limit of detection is 14.9 ng m?3 (3 ppt) of PAN. Alternatively, the PAN after separation is thermally converted to NO2 which is detected by the chemiluminescence reaction with a solution consisting of 0.002 mol L?1 luminol, 0.5 mol L?1 KOH, 0.2 mol L?1 Na2SO3, 0.1 mol L?1 KI, 0.05 mol L?1 EDTA and 0.5 vol. % triton X-100. The alternative approach affords the simultaneous determination of PAN and NO2. The limit of detection is 50 ppt of PAN and 50 ppt of NO2. The time resolution is 3 min. The method was applied to the measurement of ambient peroxyacetyl nitrate in air.  相似文献   

8.
A novel kind of carbon paste electrode (CPE) was prepared by mixing graphite powder, liquid paraffin and the ionic liquid 1-ethyl-3-methylimidazolium ethylsulfate. The resulting electrode was used for the simultaneous determination of guanosine and adenosine by differential pulse voltammetry. Compared to a conventional CPE, the oxidation peak currents are largely increased, and the oxidation peak potentials are negatively shifted. The electrochemical responses to guanosine and adenosine were investigated. Under optimized conditions, the calibration curves are linear in the concentration range from 1.0?×?10-6?mol?L-1 to 1.6?×?10-4?mol?L-1 for guanosine, and from 1.0?×?10-6?mol?L-1 to 2.7?×?10-4?mol?L-1 for adenosine at pH 3.5. Substances potentially interfering in the biological matrix do no interfere. The method was successfully applied to detect adenosine and guanosine in human urine without sample treatments.
Figure
Cyclic voltammograms on CPE (a) and CILE (b) for 1.0?×?10-4?mol?L-1 adenosine and 1.0?×?10-4?mol?L-1guanosine in a pH 3.5 B-R buffer solution at the scan rate of 100?mV?s-1. Inset was the typical differential pulse voltammograms of 1.0?×?10-4?mol?L-1 adenosine and 1.0?×?10-4?mol?L-1?L guanosine on CILE  相似文献   

9.
The present work describes the individual, selective and simultaneous quantification of acetaminophen (ACP) and tramadol hydrochloride (TRA) using a modification‐free boron‐doped diamond (BDD) electrode. Cyclic voltammetric measurements revealed that the profile of the binary mixtures of ACP and TRA were manifested by two irreversible oxidation peaks at about +1.04 V (for ACP) and +1.61 V (for TRA) in Britton‐Robinson (BR) buffer pH 3.0. TRA oxidation peak was significantly improved in the presence of anionic surfactant, sodium dodecyl sulfate (SDS), while ACP signal did not change. By employing square‐wave stripping mode in BR buffer pH 3.0 containing 8×10?4 mol L?1 SDS after 30 s accumulation under open‐circuit voltage, the BDD electrode could be used for quantification of ACP and TRA simultaneously in the ranges 1.0–70 μg mL?1 (6.6×10?6–4.6×10?4 mol L?1) and 1.0–70 μg mL?1 (3.3×10?6–2.3×10?4 mol L?1), with detection limits of 0.11 μg mL?1 (7.3×10?7 mol L?1) and 0.13 μg mL?1 (4.3×10?7 mol L?1), respectively. The practical applicability of the proposed approach was tested for the individual and simultaneous quantification of ACP and/or TRA in the pharmaceutical dosage forms.  相似文献   

10.
This work reports an in situ cobalt(II) phthalocyanine (CoPc) synthesis on a SiO2/SnO2 (SiSn) matrix surface obtained by the sol‐gel method and its electrocatalytic activity for oxidation of nitrite. A rigid disk electrode with SiSn/CoPc was used to study the electrooxidation of nitrite by the cyclic voltammetric, chronoamperometric techniques and differential pulse voltammetry (DPV). The adsorbed phthalocyanine electrocatalyzed nitrite oxidation at 0.73 V (versus SCE) using the DPV technique. The anodic peak current intensities, plotted from differential pulse voltammograms in 1 mol L?1 KCl for the concentration range 0.002 to 3.85 mmol L?1 of nitrite were linear, with a correlation coefficient of 0.998 and a detection limit of 0.95 μmol L?1.  相似文献   

11.
《Analytical letters》2012,45(8):1407-1412
Abstract

A spectrophotometric method was developed to determine nitrite using safranin as color reagent. The reaction between nitrite and safranin produces a safranin-HNO2 species, which exhibits absorption peaks at 280, 349, 420(shoulder) and 610 nm. The peak at 610 nm was chosen as the analysis wavelength because nitrite ion and safranin do not present absorption bands in this region. The Lambert-Beer law was obeyed in the concentration range 7.0 × 10?6 - 5.0 × 10?5M. The effects of various ions on absorbance of the safranin-HNO2 species were studied; the nitrite analysis can be performed without interference in the presence of the ions SCN?, Br?, CH3COO?, Cl? (≤ 1.0 × 10?3 M) and NO3 ? (< 1.0 × 10?5 M). The SO4 = does not interfere even at a concentration of 0.25M.  相似文献   

12.
An enhanced chemical denitrification process was studied as an alternative treatment of nitrate-rich wastewater which cannot be easily treated using conventional biological methods. To accelerate denitrification and to reduce the conversion to ammonia, nitrite reductants were added. In a batch test with the initial nitrate concentration of 500 mg NO 3 ? -N per L, sulfamic acid and zinc were found to be the best nitrite and metal reductants, respectively. In a column test with the initial nitrate concentration of 500 mg NO 3 ? -N per L, optimum results were experimentally obtained over a zinc scrap column with a 1.0 molar ratio of [NH2SO3H]/[NO 3 ? -N] and the recirculating flow rate of 6 L min?1 at pH 2.5. Approximately 98.8 % of nitrate anions were removed, and the observed reaction rate constant (k) was 0.135 min?1. Zinc consumption was reduced to 46.6 % compared to the procedure without sulfamic acid, and sulfamic acid consumption was reduced to 40 % compared to the results of our previous study. Based on these experimental results, it was concluded that chemical nitrate denitrification using sulfamic acid and zinc scrap is an effective alternative treatment protocol for nitrate-rich wastewater.  相似文献   

13.
The electrochemical response of a modified-carbon nanotubes paste electrode with p-aminophenol was investigated as an electrochemical sensor for sulfite determination. The electrochemical behaviour of sulfite was studied at the surface of the modified electrode in aqueous media using cyclic voltammetry and square wave voltammetry. It has been found that under the optimum condition (pH 7.0) in cyclic voltammetry, the oxidation of sulfite occurs at a potential about 680?mV less positive than that of an unmodified-carbon nanotubes paste electrode. Under the optimized conditions, the electrocatalytic peak current showed linear relationship with sulfite concentration in the range of 2.0?×?10?7–2.8?×?10?4?mol?L?1 with a detection limit of 9.0?×?10?8?mol?L?1 sulfite. The relative standard deviations for ten successive assays of 1.0 and 50.0?µmol?L?1 sulfite were 2.5% and 2.1%, respectively. Finally, the modified electrode was examined as a selective, simple and precise new electrochemical sensor for the determination of sulfite in water and wastewater samples.  相似文献   

14.
Mesoporous carbon ceramic SiO2/50 wt % C (SBET=170 m2 g?1), where C is graphite, were prepared by the sol‐gel method. The materials were characterized using N2 sorption isotherms, scanning electron microscopy, and conductivity measurements. The matrix was used as support for the in situ immobilization of Mn(II) phthalocyanine (MnPc) on their surface. XPS was used to determine the Mn/Si atomic ratios of the MnPc‐modified materials. Pressed disk electrodes were prepared with the MnPc‐modified matrix, and tested as an electrochemical sensor for nitrite oxidation. The linear response range, sensitivity, detection limit and quantification limit were 0.79–15.74 µmol L?1, 17.31 µA L µmol?1, 0.02 µmol L?1 and 0.79 µmol L?1, respectively, obtained using cyclic voltammetry. The repeatability of the proposed sensor, evaluated in terms of relative standard deviation was 1.7 % for 10 measurements of a solution of 12.63 µmol L?1 nitrite. The sensor employed to determine nitrite in sausage meat, river and lake water samples showed to be a promising tool for this purpose.  相似文献   

15.
《Analytical letters》2012,45(12):2323-2332
Abstract

A simple spectrophotometric method for the trace determination of nitrite (NO? 2) is described. Nitrite is reacted with Salbutamal sulphate in acidic medium which gives a yellow colour in alkaline medium (?pH 7) and can be determined in the presence of several cations and anions. Beer's law is obeyed in the range of 1.8 to 27.6 ppm of nitrite with the molar absorptivity 1.8 × 103 1 × mole?1 × cm?1 at 4l0 nm. The proposed method can also be utilized for the determination of nitrate (NO? 3) after its reduction to nitrite. The method has been applied for the determination of various samples containing traces of nitrite.  相似文献   

16.
A new analytical methodology for the electrochemical detection of the herbicide maleic hydrazide (3,6‐dihydroxypyridazine) by flow injection analysis is presented. This method is supported by the novel application of a palladium‐dispersed carbon paste electrode as an amperometric sensor for this herbicide. Maleic hydrazide shows anodic electrochemical activity on carbon‐based electrodes (glassy carbon or carbon paste electrodes) in all the pH range. This electrochemical activity is enhanced using metal‐dispersed carbon paste electrodes, especially at Pd‐dispersed CPE which displays good oxidation signals at 690 mV (0.050 M phosphate buffer pH 7.0), 140 mV lower than at unmodified electrodes. Under the optimized conditions, the electroanalytical performance of Pd‐dispersed CPE in flow injection analysis was excellent, with good reproducibility (RSD 3.3%) and a wide linear range (1.9×10?7 to 1.0×10?4 mol L?1). A detection limit of 1.4×10?8 mol L?1 (0.14 ng maleic hydrazide) was obtained for a sample loop of 100 μL at a fixed potential of 700 mV in 0.050 M phosphate buffer solution at pH 7.0 and a flow rate of 2.0 mL min?1. The proposed method was applied for the maleic hydrazide detection in natural drinking water samples.  相似文献   

17.
This study is aimed to develop an electroanalytical methodology using a boron‐doped diamond electrode (BDD) associated with experimental design in order to determine simultaneously and selectively carbendazin (CBZ) and fenamiphos (FNP) pesticides. In previous studies oxidation peaks were observed at 1.10 V (CBZ) and 1.20 V (FNP), respectively, with characteristics of irreversible processes controlled by diffusion of species (in pH 2.0 (CBZ) and pH 3.5 (FNP)) using a BR buffer 0.1 mol L?1 as support electrolyte. The differences between the potentials for both pesticides, (about 100 mV) indicate the possibility of selective determination of FNP and CBZ. However, employing an equimolar mixture of analytes, the peaks overlap to form a single oxidation peak. Thus, we used a 34 full factorial design with four parameters to be analyzed in three levels, in order to obtain the optimized parameters for the separation of the peaks. The best separation conditions were pH 5.0, square wave frequency of 300 s?1, pulse amplitude of 10 mV and scan increment of 2 mV. These parameters were used to obtain the calibration curves of CBZ and FNP. For CBZ the analytical curve was obtained in the concentration range of 4.95×10?6 to 6.90×10?5 mol L?1 with good sensitivity and linearity (0.175 A/mol L?1 and 0.999, respectively). The limits of detection (LOD) and quantification (LOQ) were 1.6×10?6 mol L?1 and 5.5×10?6 mol L?1, respectively. For FNP the linear concentration interval was 4.95×10?6 to 3.67×10?5 mol L?1, with a sensitivity of 0,207 A/mol L?1 and linearity of 0.996. The LOD and LOQ were 4.1×10?6 mol L?1 and 13.7×10?6 mol L?1, respectively. Using these experimental conditions it was possible to separate the oxidation peaks of CBZ (Ep=1.08 V) and FNP (Ep=1.23 V). The electroanlytical method was applied in lemon juice samples. The recovery values were 110.0 % and 92.5 % for CBZ and FNP, respectively. The results showed that the developed method is suitable for application in foodstuff samples.  相似文献   

18.
《Electroanalysis》2006,18(21):2070-2078
A highly selective potentiometric sensor for thiocyanate ion based on the use of a newly synthesized organo‐palladium ion exchanger complex dispersed in a plasticized poly(vinyl chloride) membrane is described. The sensor displays a Nernstian response (?57.8±0.2 mV decade?1) over a wide linear concentration range of thiocyanate (1.0×10?6–1.0×10?1 mol L?1 ), low detection limit (6.3×10?7 mol L?1), fast response (20 s), stable potential readings (±0.4 mV), good reproducibility (±0.9%), long term stability (8 weeks), high precision (±0.7%) and applicability over a wide pH range (4–10). Negligible interferences are caused by F?, Cl?, I?, Br?, NO3?, NO2?, CN?, SO42?, S2O32?, PO43?, citrate, acetate and oxalate ions. Under hydrodynamic mode of operation (FIA), the calibration slope is ?51.1±0.1 mV decade?1, the linear response range is 1.0×10?5–1.0×10?1 mol L?1 SCN? and the sample throughput is 40–45 per hour. The sensor is satisfactory used for manual and flow injection potentiometric determination of SCN? in the saliva and urine of cigarette smokers and non smokers. The data agree fairly well with results obtained by the standard spectrophotometric technique. Direct potentiometry and potentiometric titration of SCN? with Ag+ are also monitored with the sensor.  相似文献   

19.
《Analytical letters》2012,45(15):2949-2958
Abstract

The effect of metal ions on TiO2 mediated photocatalytic oxidation for the determination of dissolved organic nitrogen compounds is investigated. Ethylenediaminetetraaceticacid was chosen as a model molecule for DON compounds. At pH 2, 5, 7, and 10 aqueous EDTA solutions were irradiated at 254 nm in the presence of Fe2+, Cu2+, Zn2+, Ni2+ or Co2+ ions. The sum of produced nitrate, nitrite, and ammonium ion concentrations gave the total oxidation recovery. At low pH, the photocatalytic oxidation recoveries of Fe‐EDTA, Ni‐EDTA, and Co‐EDTA were significantly lower than the photocatalytic degradation of EDTA. The presence of free Fe2+, Ni2+, and Co2+ ions decreased the photocatalytic oxidation recovery. The [NH4 +]/[NO3 ?] ratio was higher for Cu‐EDTA.  相似文献   

20.
Hong Yu  Hongjing Ai  Qian Chen 《Chromatographia》2009,70(7-8):1017-1022
Ion-interaction chromatography with direct conductivity detection has been used for analysis of nitrate and nitrite. Chromatographic separation was performed on a monolithic silica-based C18 column dynamically modified with tetrabutylammonium (TBA+). Using the optimized mobile phase, containing 2.0 mmol L?1 TBA+ and 0.8 mmol L?1 citrate (pH 6.0), delivered at a flow rate of 6.0 mL min?1, separation of five anions (chloride, nitrite, bromide, nitrate, and sulfate) was achieved in only 40 s at a column temperature of 30 °C. The detection limits for nitrate and nitrite were 0.74 and 0.92 mg L?1, respectively. The relative standard deviation (RSD, n = 5) of the retention times of nitrate and nitrite was 0.1% and RSD of chromatographic peak areas were 0.4 and 0.2%, respectively. The method was successfully used for analysis of the anions in groundwater. Recovery of nitrate and nitrite was 99.1 and 105%, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号