首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 636 毫秒
1.
A liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) method was developed and validated for the assay of glucosamine sulfate in human plasma. Plasma proteins were precipitated by acetonitrile, followed by vortex mixing and centrifugation. The supernatant was transferred and derivatized with phenyl iso-thiocyanate in acetonitrile at 60 degrees C for 40 min. Chromatographic separation was performed on a C(18) column (Inertsil ODS-3 150 x 2.1 mm i.d., 5 microm, JP) with a mobile phase gradient consisting of 0.2% acetic acid (aqueous) and methanol at a flow-rate of 0.3 mL/min. MS detection using electrospray ionization (ESI) as an interface was used in single ion monitoring mode to determine positive ions at m/z 297. This method was shown to be selective and sensitive for glucosamine sulfate. The limit of detection was 35 ng/mL for glucosamine sulfate in plasma and the linear range was 0.1-20 microg/mL in plasma with a correlation coefficient (r) of 0.9991. The relative standard deviations (RSDs) of intra-day and inter-day assays were 8.7-11.4 and 9.8-12.6%, respectively. Extraction recoveries of glucosamine sulfate in plasma were greater than 73%. This method proved to be simple, reproducible and feasible for pharmacokinetic studies of glucosamine sulfate in healthy volunteers after a single oral administration (1500 mg). The pharmacokinetic parameters and relative bioavailabilities were investigated for both domestic glucosamine sulfate tablet and capsule preparations compared with an imported capsule product.  相似文献   

2.
A sensitive, precise, and specific high-performance liquid chromatography (HPLC) method was developed for the assay of lomefloxacin (LFLX) in raw material and tablet preparations. The method validation parameters yielded good results and included the range, linearity, precision, accuracy, specificity, and recovery. It was also found that the excipients in the commercial tablet preparation did not interfere with the assay. The HPLC separation was performed on a reversed-phase Phenomenex C18 column (150 x 4.6 mm id, 5 microm particle size) with a mobile phase composed of 1% acetic acid-acetonitrile-methanol (70 + 15 + 15, v/v/v), pumped isocratically at a flow rate of 1.0 mL/min. The effluent was monitored at 280 nm. The calibration graph for LFLX was linear from 2.0 to 7.0 mg/mL. The interday and intraday precisions (relative standard deviation) were less than 1.0%. The method was applied for the quality control of commercial LFLX tablets to quantitate the drug.  相似文献   

3.
Abstract

A sensitive, specific, qualitative, and quantitative extraction procedure followed by an hplc assay of 11-nor-Δ-9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) from human urine is developed. Using a new, “mixed mode”, bonded silica gel solid phase extraction (SPE) column, the analyte was selectively isolated from the urine component. Following extraction, the presence of THC-COOH was confirmed and quantitated by a UV detector on a Varian 15cm C18 column using 35:65 v/v 50 mM phosphoric acid:acetonitrile at a flow rate of 1.5 mL/min. The limit of detection was 10 ng/mL at a signal to noise ratio of 2.5. The method showed linearity in the 10–300 ng/mL range (r=0.999) with good precision (RSD 1.4%) and accuracy (87% absolute recovery).  相似文献   

4.
A highly sensitive liquid chromatographic-tandem mass spectrometric method (LC-MS-MS) is developed to quantitate ranolazine in human plasma. The analyte and internal standard tramadol are extracted from plasma by liquid-liquid extraction using diethyl ether-dichloromethane (60:40 v/v), and separated on a Zorbax extend C(18) column using methanol-10mM ammonium acetate (60:40 v/v, pH 4.0) at a flow of 1.0 mL/min. Detection is carried out by multiple reaction monitoring on a QtrapTM LC-MS-MS system with an electrospray ionization interface. The assay is linear over the range 10-5000 ng/mL with a limit of quantitation of 10 ng/mL and a lower limit of detection (S/N > 3) of 1 ng/mL. Intra- and inter-day precision are < 3.1% and < 2.8%, respectively, and the accuracy is in the range 96.7-101.6%. The validated method is successfully used to analyze the drug in samples of human plasma for pharmacokinetic studies.  相似文献   

5.
 A reversed-phase high performance liquid chromatography (HPLC) method was developed, validated, and used for the quantitative determination of gatifloxacin (GA) and ambroxol hydrochloride (AM), from its tablet dosage form. Chromatographic separation was performed on a HiQ Sil C18 column (250 mm×4.6 mm, 5 μm), with a mobile phase comprising of a mixture of 0.01 mol/L potassium dihydrogen orthophosphate buffer and acetonitrile (70∶30, v/v), and pH adjusted to 3 with orthophosphoric acid, at a flow rate of 1 mL/min, with detection at 247 nm. Separation was completed in less than 10 min. As per International Conference on Harmonisation (ICH) guidelines the method was validated for linearity, accuracy, precision, limit of quantitation, limit of detection, and robustness. Linearity of GA was found to be in the range of 10-60 μg/mL and that for AM was found to be 5-30 μg/mL. The correlation coefficients were 0.9996 and 0.9993 for GA and AM respectively. The results of the tablet analysis (n=5) were found to be 99.94% with ±0.25% standard deviation (SD) and 99.98% with±0.36% SD for GA and AM respectively. Percent recovery of GA was found to be 99.92%-100.02% and that of AM was 99.86%-100.16%. The assay experiment shows that the method is free from interference of excipients. This demonstrates that the developed HPLC method is simple, linear, precise, and accurate, and can be conveniently adopted for the routine quality control analysis of the tablet.  相似文献   

6.
《Analytical letters》2012,45(4):915-927
Abstract

A rapid reversed-phase high-performance liquid chromatographic assay was developed for chenodeoxycholic acid and ursodeoxycholic acid in commercially available capsule and tablet formulations. A Supelcosil LC-18-DB column with UV detection at 210 nm and a methanol-acetate buffer eluent were used. Individual dosage forms were disintegrated in the mobile phase and an aliquot of the resulting suspension was filtered for the HPLC analysis. Recovery of the drugs from spiked placebo preparations was quantitative. the method was tested for linearity and specificity and was found to be simple, accurate and reproducible.  相似文献   

7.
《Analytical letters》2012,45(11):1588-1602
Abstract

This article describes validated high-performance liquid chromatographic (HPLC) and high-performance thin-layer chromatographic (HPTLC) methods for simultaneous estimation of alprazolam (ALZ) and sertraline (SER) in pure powder and tablet formulation. The HPLC separation was achieved on a Nucleosil C18 column (150 mm long, 4.6 mm i.d., and 5-µm particle size) using acetonitrile and phosphate buffer (50 + 50 v/v), pH 5.5, as the mobile phase at a flow rate of 1.0 mL/min at ambient temperature. The HPTLC separation was achieved on an aluminum-backed layer of silica gel 60 F254 using acetone/toluene/ammonia (6.0:3.0:1.0, v/v/v) as the mobile phase. Quantification with the HPLC method was achieved with ultraviolet (UV) detection at 230 nm over the concentration range 3–18 µg/mL for both drugs with mean recovery of 101.86 ± 0.21 and 100.57 ± 0.31% for ALZ and SER, respectively. Quantification in HPTLC was achieved with UV detection at 230 nm over the concentration range of 400–1400 ng/spot for both drugs with mean recoveries of 101.32 ± 0.15 and 100.38 ± 0.51% for ALZ and SER, respectively. These methods are rapid, simple, precise, sensitive, and are applicable for the simultaneous determination of ALZ and SER in pure powder and formulations.  相似文献   

8.
This paper describes validated high-performance liquid chromatography (HPLC) and high-performance thin-layer chromatography (HPTLC) methods for the simultaneous estimation of pantoprazole (PANT) and domperidone (DOM) in pure powder and capsule formulations. The HPLC separation was achieved on a Phenomenex C18 column (250 mm id, 4.6 mm, 5 pm) using 0.01 M, 6.5 pH ammonium acetate buffer-methanol-acetonitrile (30 + 40 + 30, v/v/v, pH 7.20) as the mobile phase at a flow rate of 1.0 mL/min at ambient temperature. The HPTLC separation was achieved on an aluminum-backed layer of silica gel 60F254 using ethyl acetate-methanol (60 + 40, v/v) as the mobile phase. Quantification was achieved with ultraviolet (UV) detection at 287 nm over the concentration range 400-4000 and 300-3000 ng/mL with mean recovery of 99.35+/-0.80 and 99.08+/-0.57% for PANT and DOM, respectively (HPLC method). Quantification was achieved with UV detection at 287 nm over the concentration range 80-240 and 60-180 ng/spot with mean recovery of 98.40+/-0.67 and 98.75+/-0.71% for PANT and DOM, respectively (HPTLC method). These methods are simple, precise, and sensitive, and they are applicable for the simultaneous determination of PANT and DOM in pure powder and capsule formulations.  相似文献   

9.
Simultaneous determination of dextromethorphan hydrobromide (DEX), phenylephrine hydrochloride (PHEN), and carbinoxamine maleate (CAR) in pharmaceutical preparations was performed by using liquid chromatograpy (LC) and spectrophotometry. In LC, the separation was achieved on a C18 column and the optimal mobile phase for satisfactory separation in a gradient elution program was found to be acetonitrile-sodium perchlorate solution (5: 95, v/v) initially, then a linear gradient up to 60% acetonitrile in 8 min. In spectrophotometric method, a chemometric technique, principal component regression (PCR), was used. In the method, the absorbance data matrix corresponding to the concentration data matrix was obtained by the measurement of absorbances in their zero order spectra by Δλ = 1 nm in the 210–300 nm range. Then, the calibration was obtained by using this data matrix for the prediction of unknown concentrations of DEX, PHEN, and CAR in their ternary mixture. The methods proposed were validated and successfully applied to a pharmaceutical preparation, capsule, and the results were compared.  相似文献   

10.
An inexpensive, rapid and reproducible capillary electrophoretic method has been developed and validated for the determination of metformin in pharmaceutical preparations. The method was developed utilizing a fused silica capillary (60 cm x 50 microm I.D.), phosphate buffer (50 mM, 3.0 pH)-acetonitrile (95:5, v/v) as background electrolyte (BGE), 20 kV applied voltage with UV detection at 254 nm and at a working temperature of 23 +/- 1 degrees C. Linearity was observed in the concentration range from 100 ng/L to 5 microg/L, with a correlation coefficient (R2) of 0.9998. The limits of detection and quantification achieved were 60 and 100 ng/mL, respectively. The recovery of metformin from pharmaceutical preparations was 99.1%. These validation parameters demonstrate the precision of the method and its suitability for the determination of metformin in pharmaceutical tablet formulations.  相似文献   

11.
A simple, rapid and sensitive liquid chromatography/electrospray ionization tandem mass spectrometry (LC‐ESI‐MS/MS) assay method is proposed for the determination of tolvaptan in human plasma samples using tolvaptan d7 as internal standard (IS). Analyte and the IS were extracted from 100 μL of human plasma via simple liquid–liquid extraction. The chromatographic separation was achieved on a C18 column using a mixture of methanol and 0.1% formic acid buffer (80:20, v/v) as the mobile phase at a flow rate of 1.0 mL/min. The calibration curve obtained was linear (r2 ≥ 0.99) over the concentration range of 0.05–501 ng/mL. Method validation was performed as per US Food and Drug Administration guidelines and the results met the acceptance criteria. The intra‐day and inter‐day precision (coefficient of variation) and accuracy results in three validation batches across five concentration levels were well within the acceptance limits. A run time of 2.0 min for each sample made it possible to analyze more samples in a short time, thus increasing the productivity. The proposed method was successfully applied to a pharmacokinetic study of 15 mg and 60 mg tolvaptan tablet formulation in healthy South Indian male subjects under fasting condition. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
A simple, specific and sensitive HPLC method has been developed for the determination of metoprolol in human plasma and urine. Separation of metoprolol and atenolol (internal standard) was achieved on an Ace C18 column (5 μm, 250 mm×4.6 mm id) using fluorescence detection with λex=276 nm and λem=296 nm. The mobile phase consists of methanol–water (50:50, v/v) containing 0.1% TFA. The analysis was performed in less than 10 min with a flow rate of 1 mL/min. The assay was linear over the concentration range of 3 – 200 and 5 – 300 ng/mL for plasma and urine, respectively. The LOD were 1.0 and 1.5 ng/mL for plasma and urine, respectively. The LOQ were 3.0 and 5.0 ng/mL for plasma and urine, respectively. The extraction recoveries were found to be 95.6 ± 1.53 and 96.4 ± 1.75% for plasma and urine, respectively. Also, the method was successfully applied to three patients with hypertension who had been given an oral tablet of 100 mg metoprolol.  相似文献   

13.
This paper describes validated high-performance liquid chromatographic (LC) and high-performance thin-layer chromatographic (TLC) methods for the simultaneous estimation of olanzapine and fluoxetine in pure powder and tablet formulations. The LC separation was achieved on a Lichrospher 100 RP-180, C18 column (250 mm, 4.0 mm id, 5 microm) using 0.05 M potassium dihydrogen phosphate buffer (pH 5.6 adjusted with o-phosphoric acid)-acetonitrile (50 + 50, v/v) as the mobile phase at a flow rate of 1 mL/min and ambient temperature. The TLC separation was achieved on aluminum sheets coated with silica gel 60F254 using methanol-toluene (40 + 20, v/v) as the mobile phase. Quantitation was achieved by measuring ultraviolet absorption at 233 nm over the concentration range of 10-70 and 40-280 microg/mL with mean recovery of 99.54 +/- 0.89 and 99.73 +/- 0.58% for olanzapine and fluoxetine, respectively, by the LC method. Quantitation was achieved by measuring ultraviolet absorption at 233 nm over the concentration range of 100-800 and 400-3200 ng/spot with mean recovery of 101.53 +/- 0.06 and 101.45 +/- 0.35% for olanzapine and fluoxetine, respectively, by the TLC method with densitometry. These methods are simple, precise, and sensitive, and they are applicable for simultaneous determination of olanzapine and fluoxetine in tablet formulations.  相似文献   

14.
This paper describes two simple, specific, accurate, and precise methods for estimation of olopatadine hydrochloride (OLO) in tablet dosage form. The first method is a stability-indicating isocratic RP-HPLC method. The analysis is performed on an RP-18 column using 0.1% orthophosphoric acid (adjusted to pH 4.5 with triethylamine)-acetonitrile (75 + 25, v/v) mobile phase at a flow rate of 1 mL/min. Paracetamol (PAR) was selected as the internal standard. Retention times of OLO and PAR were 11.30 +/- 0.02 and 4.70 +/- 0.03 min, respectively. For the HPTLC method, precoated silica gel 60 F254 aluminum sheets were used as the stationary phase; the mobile phase was methanol-chloroform-ammonia (8 + 2 + 0.1, v/v/v). The detection of the analyte band was carried out at 301 nm, and its Rf value was 0.46 +/- 0.03. The analytical methods were validated according to International Conference on Harmonization guidelines. Linear regression analysis data for the calibration plots showed a good linear relationship between response and concentration in the range of 0.1-1 microg/mL and 0.1-0.9 microg/band for HPLC and HPTLC, respectively.  相似文献   

15.
This paper describes validated HPLC and HPTLC methods for the simultaneous determination of rosuvastatin (ROS) and ezetimibe (EZE) in a combined tablet dosage form. The isocratic RP-HPLC analysis was performed on a Chromolith C18 column (100 x 6 mm id) using 0.1% (v/v) orthophosphoric acid solution (pH 3.5)-acetonitrile (63 + 37, v/v) mobile phase at a flow rate of 1 mL/min at ambient temperature. Quantification was carried out using a photodiode array UV detector at 245 nm over the concentration range of 0.5-10 microg/mL for ROS and EZE. The HPTLC separation was carried out on an aluminum-backed sheet of silica gel 60F(254) layers using n-butyl acetate-chloroform-glacial acetic acid (1 + 8 + 1, v/v/v) mobile phase. Quantification was achieved with UV densitometry at 245 nm over a concentration range of 0.1-0.9 micro/spot for ROS and EZE. The analytical methods were validated according to International Conference on Harmonization guidelines. Low RSD values indicated good precision. Both methods were successfully applied for the analysis of the drugs in laboratory-prepared mixtures and commercial tablets. No chromatographic interference from the tablet excipients was found. These methods are simple, precise, and sensitive, and are applicable for simultaneous determination of ROS and EZE in pure powder and tablets.  相似文献   

16.
A simple, rapid, and sensitive method based on dispersive liquid–liquid microextraction combined with HPLC‐UV detection applied for the quantification of chlordiazepoxide in some real samples. The effect of different extraction conditions on the extraction efficiency of the chlordiazepoxide drug was investigated and optimized using central composite design as a conventional efficient tool. Optimum extraction condition values of variables were set as 210 μL chloroform, 1.8 mL methanol, 1.0 min extraction time, 5.0 min centrifugation at 5000 rpm min?1, neutral pH, 7.0% w/v NaCl. The separation was reached in less than 8.0 min using a C18 column using isocratic binary mobile phase (acetonitrile/water (60:40, v/v)) with flow rate of 1.0 mL min?1. The linear response (r2 > 0.998) was achieved in the range of 0.005–10 μg mL?1 with detection limit 0.0005 μg mL?1. The applicability of this method for simultaneous extraction and determination of chlordiazepoxide in four different matrices (water, urine, plasma, and chlordiazepoxide tablet) were investigated using standard addition method. Average recoveries at two spiking levels were over the range of 91.3–102.5% with RSD < 5.0% (n = 3). The obtained results show that dispersive liquid–liquid microextraction combined with HPLC‐UV is a fast and simple method for the determination of chlordiazepoxide in real samples.  相似文献   

17.
Two simple and accurate methods to determine atorvastatin calcium and ramipril in capsule dosage forms were developed and validated using HPLC and HPTLC. The HPLC separation was achieved on a Phenomenex Luna C18 column (250 x 4.6 mm id, 5 microm) in the isocratic mode using 0.1% phosphoric acid-acetonitrile (38 + 62, v/v), pH 3.5 +/- 0.05, mobile phase at a flow rate of 1 ml/min. The retention times were 6.42 and 2.86 min for atorvastatin calcium and ramipril, respectively. Quantification was achieved with a photodiode array detector set at 210 nm over the concentration range of 0.5-5 microg/mL for each, with mean recoveries (at three concentration levels) of 100.06 +/- 0.49% and 99.95 +/- 0.63% RSD for atorvastatin calcium and ramipril, respectively. The HPTLC separation was achieved on silica gel 60 F254 HPTLC plates using methanol-benzene-glacial acetic acid (19.6 + 80.0 + 0.4, v/v/v) as the mobile phase. The Rf values were 0.40 and 0.20 for atorvastatin calcium and ramipril, respectively. Quantification was achieved with UV densitometry at 210 nm over the concentration range of 50-500 ng/spot for each, with mean recoveries (at three concentration levels) of 99.98 +/- 0.75% and 99.87 +/- 0.83% RSD for atorvastatin calcium and ramipril, respectively. Both methods were validated according to International Conference on Harmonization guidelines and found to be simple, specific, accurate, precise, and robust. The mean assay percentages for atorvastatin calcium and ramipril were 99.90 and 99.55% for HPLC and 99.91 and 99.47% for HPTLC, respectively. The methods were successfully applied for the determination of atorvastatin calcium and ramipril in capsule dosage forms without any interference from common excipients.  相似文献   

18.
《Analytical letters》2012,45(15):2311-2317
The present work describes the methodology and validation of gas chromatography with flame ionization (FID) and mass spectrometric (MS) detection after derivatization with N-Methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA) for determination of atenolol with an internal standard (metoprolol) in pharmaceutical preparations. The linearity was established over the concentration range of 0.5–20 μg/mL for GC/FID and 12.5–500 ng/mL for GC/MS method. The intra- and inter-day relative standard deviation was less than 4.72 and 5.80%, respectively. Limit of quantification was determined as 500 ng/mL and 12.5 ng/mL for GC/FID and GC/MS, respectively. No interference was found from tablet excipients at the selected assay conditions. Developed GC/FID and GC/MS methods in this study are accurate, sensitive, and precise and can be easily applied to Tensinor tablet as pharmaceutical preparation.  相似文献   

19.
A highly sensitive and specific LC-MS/MS method has been developed and validated for the estimation of zafirlukast (ZFK) with 500 microL human plasma using valdecoxib as an internal standard (IS). The API-4,000 LC-MS/MS was operated under multiple reaction-monitoring mode using the electrospray ionization technique. The assay procedure involved extraction of ZFK and IS from human plasma with ethyl acetate. The resolution of peaks was achieved with 10 mm ammonium acetate (pH 6.4):acetonitrile (20:80, v/v) on a Hypersil BDS C(18) column. The total chromatographic run time was 2.0 min and the elution of ZFK and IS occurred at approximately 1.11 and 1.58 min, respectively. The MS/MS ion transitions monitored were 574.2 --> 462.1 for ZFK and 313.3 --> 118.1 for IS. The method was proved to be accurate and precise at a linearity range of 0.15-600 ng/mL with a correlation coefficient (r) of >or=0.999. The method was rugged with 0.15 ng/mL as lower limit of quantitation. The intra- and inter-day precision and accuracy values were found to be within the assay variability limits as per the FDA guidelines. The developed assay method was applied to a pharmacokinetic study in human volunteers following oral administration of 20 mg ZFK tablet.  相似文献   

20.
A highly selective, sensitive and accurate HPLC method has been developed and validated for the estimation of three fluoroquinolones (FQs) viz., gatifloxacin (GFC), sparfloxacin (SFC) and moxifloxacin (MFC) with 500 microL human plasma using levofloxacin (LFC) as an internal standard (IS). The sample preparation involved simple liquid-liquid extraction of GFC, SFC, MFC and IS from human plasma with ethyl acetate. The resolution of peaks was achieved with phosphate buffer (pH 2.5)-acetonitrile (80:20, v/v) at a flow rate of 1 mL/min on a Kromasil C(18) column. The total chromatographic run time was 18.0 min and the simultaneous elution of GFC, SFC, MFC and IS occurred at approximately 10.8, 12.8, 17.0 and 6.0 min, respectively. The method proved to be accurate and precise at linearity range of 100-10,000 ng/mL with a correlation coefficient (r) of > or =0.999. The limit of quantitation for each of the FQs studied was 100 ng/mL. The intra- and inter-day precision and accuracy values found to be within the assay variability limits as per the FDA guidelines. The developed assay method was applied to a pharmacokinetic study in human volunteers following oral administration of 400 mg GFC tablet.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号