首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
In the perspective of in-field stripping analysis of heavy metals, the use and disposal of toxic mercury solutions (necessary to plate a mercury film on a carbon electrode surface) presents a problem. The aim of this work was the development of mercury coated screen-printed electrodes previously prepared in the lab and ready to use in-field. Thus some commercially available polymers like Nafion®, Eastman Kodak AQ29®, and Methocel® were investigated as mercury entrapping systems for electrochemical stripping analysis of heavy metals. Screen-printed disposable cells with a silver pseudo-reference electrode, a graphite counter electrode, and a graphite working electrode were used. To modify the sensor, the polymer solution was cast onto the carbon working electrode surface. Detection limits of 0.8 and 1 μg/L were obtained for lead and cadmium respectively. Since Methocel® based electrodes showed the best performance, they were used for the analysis of real samples. The results were compared with those obtained using a classical thin mercury film electrode and ICP spectroscopy.

All the experiments reported here were performed in un-deareated solutions as required for in-field analysis.  相似文献   

2.
Three different commercial carbon nanomaterial-modified screen-printed electrodes based on graphene, carbon nanotubes and carbon nanofibers were pioneeringly tested as electrode platforms for the plating with Sb film. They were microscopically and analytically compared to each other and to the most conventional unmodified carbon screen-printed electrode (SPCE). The obtained detection and quantification limits suggest that the in-situ antimony film electrode prepared from carbon nanofibers modified screen-printed electrode (SbSPCE-CNF) produces a better analytical performance as compared to the classical SPCE modified with antimony for Pb(II) and Cd(II) determination, approving its appropriateness for measuring low μg L−1 levels of the considered metals. In-situ SbSPCE-CNF was successfully used for the simultaneous determination of Pb(II) and Cd(II) ions, by means of differential pulse anodic stripping voltammetry, in a certified reference estuarine water sample with a very high reproducibility and good trueness.  相似文献   

3.
Lead determination was carried out in the frame of the European Union project Biocop (www.biocop.org) using a bismuth-modified screen-printed electrode (Bi-SPE) and the stripping analysis technique. In order to choose a sensitive Bi-SPE for lead detection, an analytical comparative study of electrodes modified by Bi using "in situ", "ex situ" and "bulk" procedures was carried out. On the basis of the results obtained, we confirmed that the "in situ" procedure resulted in better analytical performances with respect to not only "ex situ" but also to "Bi(2)O(3) bulk" modified electrodes, allowing for a linear range of lead ion concentration from 0.5 to 100 μg L(-1) and a detection limit of 0.15 μg L(-1). We demonstrated that, before the Bi film deposition, an oxidative electrochemical pre-treatment of the working electrode could be useful because it eliminates traces of lead in the graphite-ink, as shown with stripping measurements. It also improves the electrochemical performance of the electrodes as demonstrated with Electrochemical Impedance Spectroscopy (EIS) measurements. The influence of different analytical parameters, such as the electrolyte solution composition (acetate buffer, chloridric acid, nitric acid, perchloric acid) and the ionic strength was investigated in order to evaluate how to treat the sample before the analysis. The morphology of prepared "in situ" Bi-SPEs was also characterized by Atomic Force Microscopy (AFM). Finally, the Bi-SPEs were used to determine the concentration of lead ions in tap and commercial water samples obtaining satisfactory values of the recovery percentage (81% and 98%).  相似文献   

4.
《Electroanalysis》2018,30(9):2004-2010
The performance of screen‐printed electrodes modified in situ with tellurium film for the anodic stripping voltammetric (ASV) determination of Cu(II) is reported. It was found that two types of screen‐printed substrates, namely carbon and mesoporous carbon, were optimal for this application. The selected in situ tellurium film modified electrodes were applied for the square wave ASV determination of copper at μg L−1 concentration levels. Well‐defined and reproducible Cu oxidation stripping peaks were produced at a potential more negative than the anodic dissolution of tellurium. The highest sensitivity of Cu determination was achieved in 0.05 M HCl containing 50 μg L−1 Te(IV) after 300 s of accumulation at −0.5 V. Using the optimized procedure, a linear range from 2 to 35 μg L−1 of Cu(II) was obtained with a detection limit of 0.5 μg L−1 Cu(II) (S/N=3) for 300 s of deposition time. Both sensors, carbon TeF‐SPE and mesoporous carbon TeF‐SPE, were successfully applied for the quantification of Cu in a certified reference surface water sample.  相似文献   

5.
《Analytical letters》2012,45(6):1223-1234
Abstract

The stripping potentiometric determination of lead, cadmium and copper with mercury film glassy-carbon electrodes coated with a Nafion membrane was investigated. The mercury film was plated using either mercury(II) acetate encapsulated within the Nafion membrane or a mercury(II) solution. Dissolved dioxygen was used as the stripping agent. The electrodes showed promising properties, particularly robustness and response repeatability. A linear dependence of the stripping time on concentration was found in the μg l?1 concentration range (s.d. of intercept ≤ 0.3 μg l?1, r.s.d. of slope ≤ 1%, for both lead and cadmium).  相似文献   

6.
The simple, fast and highly sensitive anodic stripping voltammetric detection of As(III) at a gold (Au) nanoparticle‐modified glassy carbon (GC) (nano‐Au/GC) electrode in HCl solution was extensively studied. The Au nanoparticles were electrodeposited onto GC electrode using chronocoulometric technique via a potential step from 1.1 to 0 V vs. Ag|AgCl|NaCl (sat.) in 0.5 M H2SO4 containing Na[AuCl4] in the presence of KI, KBr, Na2S and cysteine additives. Surfaces of the resulting nano‐Au/GC electrodes were characterized with cyclic voltammetry. The performances of the nano‐Au/GC electrodes, which were prepared using different concentrations of Na[AuCl4] (0.05–0.5 mM) and KI additive (0.01–1.0 mM) at various deposition times (10–30 s), for the voltammetric detection of As(III) were examined. After the optimization, a high sensitivity of 0.32 mA cm?2 μM?1 and detection limit of 0.024 μM (1.8 ppb) were obtained using linear sweep voltammetry.  相似文献   

7.
Platinum nanoflowers modified glassy carbon electrodes (PtNFs/GCE) was fabricated simply for lead determination in water samples. The modified electrodes were prepared by electrodeposition in hexachloroplatinic acid solution at constant potential. The influence of deposition time and potential on surface morphology, chemical composition, electrochemical properties of electrode were investigated. At ?0.2 V of potential and 150 s of deposition duration, platinum developed as nanoflower shape and scattered densely all over the glassy carbon surface, producing the largest electrochemically active surface areas. The highest differential pulse stripping voltammetry (DPSV) signal of lead was obtained by using the prepared electrode. Under optimized experimental condition of electrolyte, accumulation potential and time, the peak current was found to be linear proportion to lead concentration in range of 1 to 100 μg L?1 (slope=0.371) with a limit of detection of 0.398 μg L?1. The method has good repeatability and reproducibility with relative standard deviations of 1.47 % and 4.83 %, respectively. The modified PtNFs/GCE also demonstrated an excellent long‐term stability with only 9 % decrease in Pb peak current over 30 days. Moreover, the performance of the modified PtNFs/GCE in determination of Pb(II) in two industrial wastewaters was good agreement with data obtained by a graphite furnace atomic absorption spectrometry (GFAAS) method.  相似文献   

8.
A novel approach to the electrochemical determination of heavy metals in tap water using anodic stripping voltammetry was developed using screen-printed electrodes modified with gold films. After optimisation of the experimental conditions, the screen-printed electrodes modified with gold films displayed excellent linear behaviour in the examined concentration range from 2 to 16 µg L-1 mercury and lead in 50 mM HCl with a detection limit of 1.5 µg L-1 and 0.5 µg L-1 for mercury and lead, respectively. In order to decrease the working range down to less than 1 µg L-1, a preconcentration step based on the use of magnetic particles modified with thiols was introduced into the protocol. Applying optimum binding conditions, the assay using screen-printed electrodes modified with gold films displayed excellent linear behaviour in the concentration range 0.1 to 0.8 µg L-1 in 50 mM HCl. The detection limit after a 120 s deposition time for mercury and lead were 0.08 µg L-1 and 0.02 µg L-1, respectively. The method has been applied to the determination of mercury and lead traces in tap water  相似文献   

9.
《Analytical letters》2012,45(5):441-450
Abstract

A microcell has been constructed for stripping analysis in solution volumes as low as 5 μl, employing a glassy carbon or mercury-plated glassy carbon working electrodes and a three electrode system. Using normal d.c. stripping techniques, as little as 100 picograms of mercury and 10 picograms of lead can be determined. With the more sensitive second harmonic a.c. voltammetric technique, this limit is lowered to 10 picograms of mercury and 1 picogram of lead.  相似文献   

10.
《Analytical letters》2012,45(8):1425-1432
Abstract

An analytical method for indirect trace determination of ethylenediaminetetraacetic acid (EDTA) in water, by potentiometric stripping analysis is described. Excess Bi(III) was added to form a 1:1 complex with EDTA at pH 2.3. The uncomplexed Bi(III) was then deposited on a glassy carbon electrode at a potential of ?0.40 V vs. SCE and subsequently stripped potentiometrically using potassium dichromate as oxidant. The stripping time of uncomplexed Bi(III) was recorded. The Concentration of EDTA in the sample was determined from the concentration of added Bi(III) and the potentiometrically stripped Bi(III) at ?0.4 V by the standard addition method. The relative standard deviation for EDTA concentration of 95 ppb and 4.5 ppb was 1.9% and 2.6%, respectively. The detection limit was about 1 ppb EDTA for a deposition time of 3 minutes.  相似文献   

11.
Electrochemical stripping techniques are interesting candidates for carrying out onsite speciation of environmentally relevant trace metals due to the existing low-cost portable instrumentation available and the low detection limits that can be achieved. In this work, we describe the initial analytical technique method development by quantifying the total metal concentrations using Stripping Chronopotentiometry (SCP). Carbon paste screen-printed electrodes were modified with thin films of mercury and used to quantify sub-nanomolar concentrations of lead and cadmium and sub-micromolar concentrations of zinc in river water. Low detection limits of 0.06 nM for Pb(II) and 0.04 nM for Cd(II) were obtained by the standard addition method using a SCP deposition time of 180 s. The SCP results obtained for Pb(II) and Cd(II) agreed with those of inductively coupled plasma mass spectrometry (ICP-MS). The coupling of SCP with screen-printed electrodes opens up excellent potential for the development of onsite speciation of trace metals. Due to the low analysis throughput obtained for the standard addition method, we also propose a new, more rapid screening Cd(II) internal standard methodology to significantly increase the number of samples that can be analyzed per day.  相似文献   

12.
《Analytical letters》2012,45(9):1245-1257
Abstract

Screen-printing technology is a particularly attractive technique for the mass production of cheap and disposable sensors, and the use of screen-printed electrodes (SPEs) in conjunction with portable, electrochemical instrumention greatly facilitates the feasibility of on-site testing. In this work, a simple, electrochemical method using screen-printed probes has been applied to test for the presence of released lead (Pb) in the glazes of different ceramic tajines collected randomly from a local market square in Morocco. Square-wave anodic voltammetry (SWAV) was employed with SPEs that had been modified with a bismuth film and 5 µl of 0.5% nafion (SPEBi-Na). This probe displayed excellent linear behavior over the examined concentration range, from 5 to 80 µg/L Pb2+ in 100 mM acetate buffer, pH 5, with a detection limit of 4 ppb for lead and (r2 = 0.9972). The good reproducibility obtained with this system led us to apply it to determine lead in this typical Moroccan cookware under conditions relevant to its use. The results showed that when tajines containing 3% acetic acid were heated for 30 min, the amounts of leached lead ranged from 16.8 to 26.4 ppm. When the tajines contains lemon instead of 3% acetic acid and was heated for 30 min, then amounts of lead released exceeded 37 ppm. These values are greater than the allowed maximum concentrations in the United States and Canada.  相似文献   

13.
Heavy metals in drinking water have become a severe threat to human health. Detection of heavy metals has been achieved by electrochemical sensors that are modified with complex nanocomposites; however, reproducibility of these sensors is still a big challenge when applied in commercial settings. Here, a simple, very robust, and sensitive electrochemical sensor based on a screen-printed carbon electrode modified with butterfly-shaped silver nanostructure (AgNS/SPCE) has been developed for the concurrent determination of cadmium (II), lead (II), copper (II), and mercury (II) in water samples. The electrochemical behavior of the modified electrodes was investigated using cyclic voltammetry and differential pulse anodic stripping voltammetry. The AgNS/SPCE showed distinct peak potentials and a significant increase in the peak currents for all heavy metals, attributed to the high electrical conductivity and electrocatalytic activity of the synthesized butterfly-shaped AgNS. Moreover, the excellent stability and sensitivity towards simultaneous quantification of heavy metals have been obtained with detection limits of 0.4 ppb, 2.5 ppb, 7.3 ppb, and 0.7 ppb for Cd (II), Pb (II), Cu (II), and Hg (II), respectively. Besides, the constructed sensor was successfully applied to simultaneously quantify target heavy metals in spiked water samples. Owing to excellent sensitivity, high robustness, affordability, and fast response, the presented electrochemical sensor could be incorporated into a portable and miniaturized potentiostat device, making it a promising method for on-site water analysis.  相似文献   

14.
Carbon screen-printed electrodes (CSPE) modified with gold nanoparticles present an interesting alternative in the determination of antimony using differential pulse anodic stripping voltammetry. Metallic gold nanoparticles deposits have been obtained by direct electrochemical deposition. Scanning electron microscopy measurements show that the electrochemically synthesized gold nanoparticles are deposited in aggregated form. Any undue effects caused by the presence of foreign ions in the solution were also analyzed to ensure that common interferents in the determination of antimony by ASV. The detection limit for Sb(III) obtained was 9.44 × 10−10 M. In terms of reproducibility, the precision of the above mentioned method in %R.S.D. values was calculated at 2.69% (n = 10). The method was applied to determine levels of antimony in seawater samples and pharmaceutical preparations.  相似文献   

15.
A carbon paste electrode modified with 2‐aminothiazole functionalized poly(glycidylmethacrylate‐methylmethacrylate‐divinylbenzene) microspheres was used for trace determination of mercury, copper and lead ions. After the open‐circuit accumulation of the heavy metal ions onto the electrode, the sensitive anodic stripping peaks were obtained by square wave anodic stripping voltammetry (SWASV)). Many parameters such as the composition of the paste, pH, preconcentration time, effective potential scan rate and stirring rate influence the response of the measurement. The procedures were optimized for most sensitive and reliable determinations of the desired species. For a 10‐min preconcentration time in synthetic solutions at optimum instrumental and experimental conditions, the detection limit (LOD) was 12.3, 2.8 and 4.5 μg L?1 for mercury, copper and lead, respectively. The limits of detection may be enhanced by increasing the preconcentration time. For example, LOD of mercury and copper was 4.9 and 1.0 μg L?1 for fifteen minutes preconcentration time. The sensitivity may also considered to be increased by using a more suitable electrode composition targeting the more conductive electrode with lesser amount of modified polymer for sub‐μg L?1 levels of heavy metal ions. The optimized method was successfully applied to the determination of copper in tap water and waste water samples by means of standard addition procedure. The copper content found was comparable with the certified concentration of the waste water sample. The calibration plots for mercury and lead spiked real samples were also drawn.  相似文献   

16.
《Electroanalysis》2017,29(11):2602-2609
New silica‐modified glassy carbon electrodes prepared with three different sorts of ordered mesoporous silica (OMS) were characterized and tested for the electrochemical detection of Malachite Green (MG). The electrodes were prepared by drop casting using silica suspensions and, for stability sake, a Nafion coating was deposited on the electrode top by the same technique. Square wave anodic stripping voltammetry was used to investigate the effect of various experimental parameters (deposition time, solution pH, silica type and concentration) on the performance of the modified electrodes. The best electrode (GC/MCM‐41‐NH2/Nafion) with detection limit 0.36 μM, sensitivity 0.164±0.003 A/M; linear domain 1–6 μM was applied to detect MG in a commercial product commonly used as biocide in aquaria for ornamental fish.  相似文献   

17.
Carbon screen-printed electrodes (CSPE) modified with silver nanoparticles present an interesting alternative in the determination of lamotrigine (LTG) using differential pulse adsorptive stripping voltammetry.Metallic silver nanoparticle deposits have been obtained by electrochemical deposition. Scanning electron microscopy measurements show that the electrochemically synthesized silver nanoparticles are deposited in aggregated form.The detection limit for this analytical procedure was 3.72 × 10−7 M. In terms of reproducibility, the precision of the above mentioned method in %R.S.D. values was calculated at 2.58%.The method was applied satisfactorily to the determination of LTG in pharmaceutical preparations.  相似文献   

18.
19.
《Electroanalysis》2006,18(24):2486-2489
This paper presents the enhanced analysis of copper on a bismuth electrode upon addition of gallium(III). The presence of gallium alleviates the problems of overlapping stripping signals usually observed between copper and bismuth when using the Bismuth Film Electrode. In addition, it has been found that the presence of gallium improves the reproducibility of the bismuth stripping signal. Simultaneous deposition of copper and bismuth at ?1500 mV for 2 minutes in a supporting electrolyte composed of 0.1 M pH 4.75 acetate buffer with 250 μg L?1 gallium yields well resolved copper and bismuth signals when analyzed with square‐wave anodic stripping voltammetry. Simultaneous analysis of copper and lead yielded linear calibration plots in the range 10 to 100 μg L?1 with regression coefficients of 0.997 and 0.994 respectively. The theoretical detection limit for copper was calculated to be 4.98 μg L?1 utilizing a 2 minutes deposition time. The relative standard deviation for a copper concentration of 50 μg L?1 was 1.6% (n=10).  相似文献   

20.
以铋膜修饰玻碳电极为工作电极,采用阳极溶出伏安法对微量Pb(Ⅱ)进行测定。考察了铋离子浓度、支持电解质pH、沉积时间等因素对测定的影响。实验结果表明,铋膜修饰电极对痕量Pb(Ⅱ)具有良好的电化学响应。在实验选定条件下,Pb(Ⅱ)在10~260!g/L范围内与峰电流呈良好的线性关系,检出限为1.98!g/L。用同一支铋膜电极对50!g/L Pb(Ⅱ)平行测定10次,相对标准偏差(RSD)为2.82%。该电极可应用于井水中铅的测定。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏