首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A reliable procedure for the electrothermal atomic absorption spectrometry (ETAAS) determination of gold and silver in waters at trace level is described. The method is based on prior separation and preconcentration of the metals using a chelating sorbent SPHERON® Thiol 1000 after acidification of water samples (pH < 3) with nitric acid. Optimization of analytical variables during enrichment and ETAAS determination of the metals are discussed. The accuracy of the method is verified by analysis of certified reference materials. The limits of determinations based on 10 σ definition were 0.005 ng cm?3 for Au and 0.02 ng cm?3 for Ag. Precision of studied elements determination expressed by relative standard deviation varied in the range from 2.9 % to 16.4 %.  相似文献   

2.
A simple, reliable and novel solid phase extraction procedure using the Empore? chelating disk has been developed for determination of Tl(I) and Tl(III) in environmental water samples by electrothermal atomic absorption spectrometry (ETAAS). The influence of humic acids on separation/preconcentration of thallium species with the Empore? chelating disk is investigated. The preconcentration factor and detection limit are 500 and 5?ng?L?1, respectively. The recoveries are in the range 93–103% for mineral, pond, sea, snowmelt, waste waters at 28–500?ng?L?1 Tl and in the range 82–112% for river waters at 18–28?ng?L?1 Tl.  相似文献   

3.
《Analytical letters》2012,45(14):2772-2782
Abstract

A simple and sensitive flow injection on line separation and preconcentration system coupled to hydride generation atomic fluorescence spectrometry (HG‐AFS) was developed for ultra‐trace bismuth determination in water and urine samples. The preconcentration of bismuth on a nylon fiber‐packed microcolumn was carried out based on the retention of bismuth complex with Bismuthiol I. A 15% (v/v) HCl was introduced to elute the retained analyte complex and merge with KBH4 solution for HG‐AFS detection. Under the optimal experimental conditions, an enhancement factor of 20 was obtained at a sample frequency of 24/h with a sample consumption of 13.0 ml. The limit of detection was 2.8 ng/l and the precision (RSD) for 11 replicate measurements of 0.1 µg/l Bi was 4.4%.  相似文献   

4.
Solidified floating organic drop microextraction was applied as a separation/preconcentration step prior to the electrothermal atomic absorption spectrometric (ETAAS) determination of ultra trace of antimony species. The method was based on the formation of an extractable complex between Sb(III) and ammonium pyrrolidinedithiocarbamate at pH ~ 5, while Sb(V) was remained in the aqueous phase. The antimony extracted into 1-undecanol was determined by ETAAS. Total antimony was determined after the reduction of Sb(V) to Sb(III) with potassium iodide and ascorbic acid. The amount of Sb(V) was determined from the difference of concentration of total antimony and Sb(III). Under the optimum conditions an enhancement factor of 437.5 and a detection limit of 5.0 ng L?1for the preconcentration of 25 mL of sample was achieved. The relative standard deviation at 300 ng L?1 of antimony was found to be 3.5 % (n = 6). The proposed method was successfully applied to the determination of antimony in tea, basil and natural water samples.  相似文献   

5.
A simple and sensitive method has been developed for the trace determination of bismuth in aqueous samples by a combination of solid‐phase extraction and hydride generation atomic absorption spectrometry. The method is based on the use of a column packed with 2‐mercaptobenzothiazole immobilized on sodium dodecyl sulfate coated alumina. Different parameters influencing the separation and preconcentration of bismuth such as pH, sample volume, type, and concentration of eluent, and the flow rate of sample and eluent were studied. A sample volume of 500.0 mL resulted in a preconcentration factor of 100. The precision (relative standard deviation, N = 10) at the 300 ng/L level and the limit of detection (3s) were found to be 2.3% and 12 ng/L, respectively. The developed method was successfully applied to the determination of bismuth in natural water samples and two certified reference materials.  相似文献   

6.
Cloud point extraction was applied as a preconcentration step for the determination of trace level of Al(III) in water samples with electrothermal atomic absorption spectrometry (ETAAS), flame atomic absorption spectrometry (FAAS) and UV-visible spectrophotometry. The aluminum was extracted as aluminum-Eriochrome Cyanine R (ECR) complex, at pH 6 by micelles of the non-ionic surfactant octylphenoxypolyethoxyethanol (Triton X-114). The investigations showed that the same CPE procedure can be used for different detection techniques. The results obtained from these techniques were evaluated. Under the optimal conditions, limit of detection obtained with ETAAS, FAAS and UV-visible spectrophotometry were 0.03 ng mL?1, 0.06 µg mL?1 and 0.01 µg mL?1, respectively. The accuracy of the procedure was tested by analysing certified reference material. The method was successfully applied to determination of aluminum in water samples and dialysis fluid.  相似文献   

7.
R Knob  V Maier  J Petr  V Ranc  J Sevčík 《Electrophoresis》2012,33(14):2159-2166
Separation of major environmental pollutants as perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS) by capillary electrophoresis is reported for the first time. It is not possible to resolve the solutes in an aqueous media. However, the use of methanol and acetonitrile as the background electrolyte (BGE) solvents allowed their rapid separation in an uncoated capillary. A major effort was put into BGE optimization in respect to both separation efficiency and detection for further on‐line preconcentration. 5 mmol.L?1 naphthalene‐1‐sulfonic acid and 10 mmol.L?1 triethylamine dissolved in ACN/MeOH (50:50 v/v) provided best separation and detection conditions. Next, the large‐volume sample stacking and the field‐amplified sample injection were applied and compared. Large‐volume sample stacking improved limits of detection (LODs) with regard to the standard injection by 69 times for PFOA and 143 times for PFOS with LODs of 280 and 230 nmol.L?1, respectively. Field‐amplified sample injection improved LODs 624 times for PFOAand 806 times for PFOS with LODs 31 and 40 nmol.L?1, respectively. Both preconcentration methods showed repeatabilities of migration times less than 1.2% RSD intraday and 6.6% RSD interday. The method was applied on PFOA and PFOS analysis in a sample of river water treated with solid‐phase extraction, which further improved LOD toward 5.6 × 10?10 mol.L?1 for PFOS and 6.4 × 10?10 mol.L?1 for PFOA and allows the method to be used for river water contamination screening or decomposition studies.  相似文献   

8.
《Analytical letters》2012,45(13):2241-2254
Abstract

The operating conditions for the spectrophotometric determination of bismuth(III) with 1-(4′-bromophenyl)-4,4,6-trimethyl-(1H,4H)-pyrimidine-2-thiol (4′bromo PTPT) as a ligand by a liquid-liquid extraction technique are presented. In acidic conditions bismuth(III) forms a yellow complex with the ligand which can be extracted in chloroform with an absorption maxima at 410 nm. The molar absorptivity is 1.5×104 l mole?1 cm?1 and Sandell's sensitivity is 14.3 ng cm?2. The difference in the absorbance between the chloroform blank and bismuth(III) sample increases linearly in the concentration range 2-14 ppm at 0.3 M hydrochloric acid. The proposed method is extremely sensitive, rapid, reproducible and has been satisfactorily applied to the determination of trace amounts of bismuth(III) in synthetic mixtures, alloys and pharmaceutical formulations and also provides binary separation of bismuth(III) from selenium, tellurium, lead, antimony, copper and gold. The overall process of extraction and determination takes about 15 to 20 min.  相似文献   

9.
A new method for the determination of butyltin species by ion-exchange chromatography linked with graphite-furnace electrothermal atomic absorption spectrometry (ETAAS) is presented. The separation is achieved on a strong cation-exchange column with a 0.18 mol dm?3 solution of diammonium citrate at pH 6.5 with a step change to pH 4.0 in 60:40 methanol/water solvent. ETAAS detection is performed on-line using an oxidizing matrix modifier. Mono-, di- and tri-butyltin may be determined in a single experiment with detection limits of (respectively) 0.5, 1.1 and 0.8 ng (Sn). Applications to actual samples are reported.  相似文献   

10.
A flow solid phase extraction procedure based on biosorption of Pt(IV) and Pd(II) on Aspergillus sp. immobilized on cellulose resin Cellex-T was proposed for the separation and preconcentration of Pt and Pd before their determination by electrothermal atomic absorption spectrometry (ETAAS). The analytical conditions including sample pH, eluent type, flow rates of sample and eluent solutions were examined. The analytes were selectively retained on the biosorbent in acidic medium (pH 1) and subsequently eluted from the column with 1 mL of thiourea solution (0.25 mol L− 1 thiourea in 0.3 mol L− 1 HCl). The reproducibility of the procedure was below 5%. The limit of detection of the method was 0.020 ng mL− 1 for Pt and 0.012 ng mL− 1 for Pd. The method validation was performed by analysis of certified reference materials BCR-723 (tunnel dust) and SARM-76 (platinum ore). The developed separation procedure was applied to the determination of Pt and Pd in road dust samples by ETAAS.The applied biosorbent is characterized by high sorption capacity: 0.47 mg g− 1 for Pt and 1.24 mg g− 1 for Pd.  相似文献   

11.
A column, solid phase extraction (SPE), preconcentration method was developed for determination of silver by using alumina coated with 1-((5-nitrofuran-2-yl)methylene)thiosemicarbazide and determination by flame atomic absorption spectrometry. The separation/preconcentration conditions for the quantitative recovery were investigated. At pH 2, the maximum sorption capacity of Ag+ was 7.5?mg?g?1. The linearity was maintained in the concentration range of 0.02–11.0?µg?mL?1 in the final solution or 0.14–1.10?×?104?ng?mL?1 in the original solution for silver. The preconcentration factor of 140 and relative standard deviation of ±1.4% was obtained, under optimum conditions. The limit of detection (LOD) was calculated as 0.112?ng?mL?1, based on 3σbl/m (n?=?8) in the original solutions. The proposed method was successfully applied to the determination trace amounts of silver in the environmental samples such as tea, rice and wheat flour, mint, and real water samples.  相似文献   

12.
A new, simple, fast and reliable solid-phase extraction method has been developed for separation/preconcentration of trace amounts of Pb(II) using dithizone/sodium dodecyl sulfate-immobilized on alumina-coated magnetite nanoparticles, and its determination by flame atomic absorption spectrometry (FAAS) and graphite furnace atomic absorption spectrometry (GFAAS) after eluting with 4.0?mol?L?1 HNO3. Optimal experimental conditions including pH, sample volume, eluent concentration and volume, and co-existing ions have been studied and established. Under the optimal experimental conditions, the preconcentration factor, detection limit, linear range and relative standard deviation of Pb(II) using FAAS technique were 280 (for 560?mL of sample solution), 0.28?ng?mL?1, 1.4?C70?ng?mL?1 and 4.6% (for 10?ng?mL?1, n?=?10), respectively. These analytical parameters using GFAAS technique were 300 (for 600?mL of sample solution), 0.002?ng?mL?1, 0.006?C13.2?ng?mL?1 and 3.1% (for 5?ng?mL?1, n?=?10), respectively. The presented procedure was successfully applied for determination of Pb(II) content in opium, heroin, lipstick, plants and water samples.  相似文献   

13.
A simple flame atomic absorption spectrometric (FAAS) procedure for the determination of lead, bismuth, gold, palladium and cadmium as impurities in Raney nickel and nickel oxide was developed using a preconcentration step on an Amberlite XAD-16 resin packed column. Lead, bismuth, gold, palladium and cadmium were quantitatively recovered and separated from a solution containing 1 M HCl and 0.3 M NaI by the column system. Effects of the various parameters such as reagent concentrations, sample volume, matrix effects, etc. have been investigated. Under optimized conditions, the relative standard deviation of the combined method of sample treatment, preconcentration and determination with FAAS (n = 7) is generally lower than 12%. The limit of detection (3s, n = 20) was between 10–270 ng/g. The results were used for separation and preconcentration of five trace elements from nickel matrices. Received: 8 February 2000 / Revised: 31 March 2000 / Accepted: 7 April 2000  相似文献   

14.
This article deals with the determination of traces of elements in the ng and pg range by emission spectroscopy with a He-MIP excitation after electrolytic preconcentration in a graphit tube followed by electrothermal atomization. A multi-stage combined procedure is described for the sensitive and reliable determination of trace elements in high-purity metals. Electrolytically depositable elements such as noble metals, copper, as well as bismuth, cadmium, iron, cobalt, zinc, and others are preconcentrated from acidic solutions with concentrations ? 0.05 ng ml?1 after the decomposition of the sample if the matrix elements are not deposited. The electrolyte is cycled through a small cylindrical cathode of pure graphite on the inner wall of which the elements are deposited. The graphite tube is coupled directly to the quartz capillary of a microwave induced helium plasma (MIP). After electrothermal atomisation the trace elements are determined by emission spectrometry. Different types of MIP excitation sources are investigated. The MIP with the TM010 microwave resonator shows optimal properties. For the determination of the trace elements in niobium and beryllium detection limits near 1 ng g?1 and relative standard deviations between 6.5 and 15% are obtained.  相似文献   

15.
A flow injection on-line sorption preconcentration system has been synchronously coupled to an electrothermal atomic absorption spectrometry (ETAAS) system for the selective determination of trace amounts of Sb(III) in water, soil and plant. The determination was achieved by selective complexation and sorption of Sb(III) with [1,5-bis(2-pyridyl)-3-sulphophenyl methylene thiocarbonohydarzide (PSTH) immobilized on an anion-exchange resin (Dowex 1× 8-200)] at a wide range of pH, quantitative elution with 50 μl of 2 M HNO3 and subsequent ETAAS detection. ETAAS determination of the analyte was performed in parallel with the preconcentration of the next sample. Using a preconcentration time of 60 s and a sample loading flow rate of 2.8 ml min−1, an enhancement factor of 12 was obtained in comparison with direct injection of 50 μl aqueous solution, resulting in a sampling frequency of 31 samples h−1. The detection limit (3 s) was 2 μg l−1 and the precision was 3.1% (R.S.D.) for 11 replicate determinations at 10 μg l−1. The accuracy of the proposed method was demonstrated by analyzing one certified sample and different spiked samples.  相似文献   

16.
A batch process was developed to extract bismuth ions by a novel and selective sorbent. In this study, a new Bi(III)-ion imprinted polymer was prepared by formation of 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol complex for selective preconcentration of ultra trace amounts of bismuth. Polymerization was performed with ethylene glycol dimethacrylate, as crosslinking monomer and methacrylic acid as functional monomer; in the presence of 2,2-azobisisobutyronitrile, as initiator, via bulk polymerization. Optimum pH for maximum sorption was 2.5–3.5. Maximum sorbent capacity and enrichment factor for bismuth were 35.9?mg?g?1 and 300, respectively. The relative standard deviation and limit of detection the method were evaluated as ±4.1% and 8.6?ng?L?1. This method is simple, selective and sensitive and can be applied to the determination of bismuth in water, biological and plant samples.  相似文献   

17.
A simple and practical preconcentration method using cloud point approach is proposed for the extraction and preconcentration of Cu (II). The analyte in the initial aqueous solution, acidified with HCl, is complexed with O,O-diethyldithiophosphate and Triton X-100 is added as a surfactant. After phase separation at 40°C based on cloud point of the mixture and dilution of the surfactant-rich phase with methanol, the enriched analyte is determined by flame atomic absorption spectrometry using conventional nebulization and the analytical wavelength used is 324.8 nm. The variables affecting the complexation and extraction steps were optimized. Under optimum conditions, preconcentration of 10 ml of sample in the presence of 0.1% (v/v) Triton X-100 permitted the detection of 0.94 ng ml−1 of Cu. Analytical graphs were rectilinear in the concentration range of 5-200 ng ml−1 and relative standard deviations were lower than 3%. The method affords recoveries in the range 97-101%. The method was successfully applied to the determination of Cu in drinking and rainwater, serum and human hair samples.  相似文献   

18.
This work reports the utility of an iridium microwire plated in situ with a bismuth film for the simultaneous determination of Pb(II) and Cd(II) by square‐wave anodic stripping voltammetry (SWASV). The experimental variables (concentration of the bismuth plating solution, preconcentration potential, accumulation time) were investigated. The limit of detection was 1 µg L?1 for Pb(II) and 1.5 µg L?1 for Cd(II) (at 300 s of preconcentration) and the % relative standard deviations were lower than 4.9 % and 5.5 %, respectively, at the 20 µg L?1 level (n=8). In addition, a study was made of coating the iridium‐based bismuth‐film microsensor with a film of Nafion for operation in the presence of surfactants. Finally, the electrode was applied to the determination of Pb(II) and Cd(II) in wastewater and tapwater samples.  相似文献   

19.
The yeast Saccharomyces cerevisiae immobilized in calcium alginate beads was used for separation and subsequent determination of Pt in environmental samples by flow-injection chemiluminescence (FI-CL) and electrothermal atomic absorption spectrometry (ETAAS). The application of a yeast column resulted in an increase in the tolerable matrix ions concentration compared to direct measurements by both detection techniques. The developed FI-CL method of Pt determination based on the catalytic effect of Pt(IV) ions on luminol oxidation in alkaline medium is characterized by a low limit of detection (0.15 ng mL?1), and good sensitivity and precision, and can be used for analysis of Pt in water samples. Determination of Pt in more complex environmental samples can be carried out by ETAAS (LOD?=?6 ng mL?1) after introduction of a column clean-up step with 10 mM nitric acid. The accuracy of the method was confirmed by analyzing the certified reference material of platinum ore (SARM-7), spiked grass, and road dust samples.  相似文献   

20.
 The applicability of tetramethylenedithiocarbamate (TMDTC) and hexamethylenedithiocarbamate (HMDTC) for colloid flotation separation of manganese in traces from fresh (spring, well and tap) water was studied. The experimental conditions for the successful manganese separation and preconcentration before electrothermal atomic absorption spectrometric (ETAAS) determination were optimised. Higher enrichment of manganese was achieved when a larger amount of HMDTC is used. Applying iron(III) hexamethylenedithiocarbamate, Fe(HMDTC)3, as a precipitate collector, manganese was determined at μg/L levels singly or simultaneously with lead and zinc in 1 L of water sample. The applicability of the proposed procedure have been verified by analyses of fresh water samples using the method of standard addition, as well as by comparing the results obtained by ETAAS with those obtained by inductively coupled plasma-atomic emission spectrometry (ICP-AES). The detection limit of manganese using this method is 0.025 μg/L. Received August 30, 1999. Revision May 15, 2000  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号