首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A solid ion-pair material produced from 1,10-phenanthroline and tetraphenylborate on naphthalene provides a simple, rapid and fairly selective means of preconcentrating copper from up to 1000 ml of aqueous samples (about 200-fold concentration is possible). Copper is quantitatively adsorbed in the pH range 1.6–10.4 at a flow rate of 3 ml min?1. The solid mass (0.2 g) is dissolved from the column with 5 ml of dimethylformamide (DMF) and copper is measured by atomic absorption spectrometry at 324.7 nm. Linear calibration is obtained for 2–28 μg of copper in 5 ml of DMF solution. Replicate determination of 14 μg of copper gave a mean absorbance of 0.220 (n = 7) with a relative standard deviation of 1.5%. The sensitivity for 1% absorption was 0.093 μg ml?1. After optimization, the method was applied to determine trace copper in standard reference materials, natural waters, beverages and hair.  相似文献   

2.
A solid uncharged complex produced from 2‐aminocyclopentene‐1‐dithiocarboxylic acid (synthetic reagent) on naphthalene provides a very sensitive, selective and economical method for the preconcentration and determination of trace amounts of copper in drug and alloy samples. The 2‐aminocyclopentene‐1‐dithiocarboxylate of copper is retained quantitatively on microcrystalline naphthalene in the pH range 2.8–3.3. After filtration the solid mass consisting of copper complex‐naphthalene is dissolved with 4 mL of dimethylformamide (DMF). The absorbance is measured at 462 nm with a spectrophotometer against the reagent blank and molar absorptivity found to be 2.8 × 105 liter mol?1 cm?1. Beer's law is obeyed over the concentration range of 0.1–16.0 μg of copper in 4 mL of the dimethylformamide solution. Detection limit is 3 ng mL?1 [signal to noise ratio = 2]. Ten replicate determinations on a sample containing 1 μg of copper gave a relative standard deviation of 0.76%. The interference of a large number of anions and cations have been studied and the optimized conditions developed were utilized for determination of copper in various real samples.  相似文献   

3.
A solid ion-pair material produced from tetradecyldimethylbenzylammonium chloride (TDBA) and ammonium thiocyanate on naphthalene provides a simple, rapid and selective technique of preconcentrating cobalt from up to 200 ml of aqueous solution. Cobalt reacts with sodium 1-nitroso-2-naphthol-3,6-disulphonate (nitroso-R salt) to form a brown, water-soluble chelate anion. The chelate anion forms a water-insoluble Co-nitroso-R salt-TDBA complex on naphthalene packed in a column and trace cobalt is quantitatively retained on the naphthalene in the pH range 2.7–11.0 at a flow-rate of 2 ml min?1. The solid mass is stripped from the column with 5 ml of dimethylformamide (DMF) and cobalt is measured by atomic absorption spectrometry (AAS) at 241 nm. The calibration graph is linear over the concentration range 0.5–15μg Co in 5 ml of dimethylformamide solution. Seven replicate determinations of 9 μg of cobalt gave a mean absorbance of 0.095 with a relative standard deviation of 1.7%. The sensitivity for 1% absorption was 0.0834μg ml?1 (0.240 μg ml?1 for direct AAS on the aqueous solution). The proposed method was utilized for the determination of cobalt in standard aluminium alloys and steel samples.  相似文献   

4.
A column method has been established for the preconcentration of aluminum and copper(II) with Alizarin Red S and a cetyltrimethylammonium-perchlorate ion pair supported on naphthalene, using a simple glass-tipped tube. Aluminum and copper(II) react with Alizarin Red S to form water-soluble colored chelate anions. These chelate anions form water-insoluble ternary complexes with the adsorbent on the inactive surface of naphthalene packed into a column. They are quantitatively retained in the pH ranges of 4.7-5.2 for aluminum and 5.0-10.0 for copper. The solid mass is dissolved out from the column with 5 ml of dimethylformamide (DMF) for aluminum and 5 ml of ethanol for copper and the absorbance was measured with a spectrometer at 525 nm for aluminum and at 529 nm for copper. The calibration curves were linear over the concentration ranges of 0.25-5.0 μg of aluminum in 5 ml of DMF solution and 0.50-12.0 μg of copper in 5 ml of ethanol solution. The molar absorptivities and Sandell′s sensitivities were respectively calculated to be 2.8 × 104 liter · mol−1 · cm−1 and 9.62 × 10−4 μg · cm−2 for aluminum and 2.5 × 104 liter · mol−1 · cm−1 and 2.5 × 10−3 μg · cm−2 for copper. Seven replicate determinations of sample solutions containing 2.5 μg of aluminum and 6.0 μg of copper gave mean absorbances of 0.520 and 0.480 with relative standard deviations of 1.67 and 0.33%, respectively. Interference due to various foreign ions has been studied and the method has been applied to the determination of aluminum in standard alloys, tea leaves, vehicle particulates, copper in coal fly ash, and commercial salt samples.  相似文献   

5.
《Analytical letters》2012,45(13-14):2835-2846
Abstract

A solid chelating compound, phenanthrenequinonedioxime(PQDO) supported on naphthalene provides a rapid and economical means of preconcentration of palladium from the aqueous samples. Palladium forms a complex with PQDO supported on naphthalene in the column at pH 1.2~2.7. The metal complex and naphthalene are dissolved out from the column with 5 ml of dimethylformamide-nitric acid (100+4) and the absorbance is measured atomic absorption spectrometer at 244.7 nm. A calibration curve is linear over the concentration range 1~24 μg of palladium in 5 ml of the final solution. The sensitivity for 1% absorption is 0.126 μg/ml (0.153 μg/ml for the direct AAS method from the aqueous medium). The method has been used for the determination of palladium in various synthetic samples and can be safely applied to the environmental samples too.  相似文献   

6.
A solid material consisting of dimethyl glyoxime (DMG), acenaphthenequinone dioxime (ANDO) or DMG-ANDO on naphthalene provides a very convenient, rapid and economical method for the preconcentration of palladium in synthetic samples. Pd-DMG, Pd-ANDO and Pd-DMG-ANDO are quantitatively retained on naphthalene in the column in the pH ranges 2.2–4.4, 1.8–5.6 and 1.7–6.8, respectively. The solid mixture consisting of the metal complex together with naphthalene is stripped from the column with 5 ml of dimethylformamide (DMF)-n-butylamine and the absorbance is measured at 247.6 nm with an atomic absorption spectrometer. Calibration graphs are linear over the palladium concentration range 5–25 μg per 5 ml of the final solution for all the three complexes. Ten replicate determinations of a sample solution containing 10 μg of palladium gave mean absorbances of 0.180, 0.225 and 0.230 with relative standard deviations of 1.8, 1.7 and 1.6% using the reagents DMg, ANDO and DMG-ANDO, respectively. The sensitivity of the method is better than the direct atomic absorption spectrometric determination of palladium. It is highest in case of the mixed ligands, i.e., DMG-ANDO (0.038 μg ml?1 for 1% absorption). The method can be applied to the trace determination of palladium in complex materials.  相似文献   

7.
2-Mercaptobenzothiazole (MBT) loaded on glass beads with the aid of collodion was prepared and used for selective preconcentration of μg l?1 levels of copper(II) and lead from aqueous solutions. Copper and lead were quantitatively retained on the loaded beads from solutions of pH 5.0–6.0 and >5.0, respectively, while cadmium(II) and zinc(II) were retained at ? pH 6.0 and 7.0, respectively. The retention capacity of the loaded beads was ca. 108 μg Cu g?1 (1.7 μmol g?1) at pH 5.5 for beads of 0.3–0.4 mm diameter. The mole ratios of MBT to copper(II) and lead(II) were ca. 10 and 45, respectively, regardless of the amount of MBT loaded on the beads. Copper was completely retained on the column at a high flow rate (21.7 ml min? cm?2) and lead(II) at up to 12.7 ml min? cm?2. Cadmium(II) and zinc(II) were not retained quantitatively even at low flow rates (< 1.2 ml min?1 cm?2). Thus, selective preconcentration of copper and lead was achieved by passing the sample through the column at high flow rate at pH 6.5. The copper and lead retained on the column were complete eluted together with the collodion with 5 ml of MIBK by batch-mode elution, and determined directly by one-drop atomic absorption spectrometry. Copper(II) and lead(II) in several kinds of water were determined.  相似文献   

8.
《Analytical letters》2012,45(6):1119-1130
Abstract

In this paper the absorption spectra of 4f electron transitions of the systems of neodymium and erbium with 8-hydroxyquino-line-5-sulphonic acid and diethylamine have been studied by normal and third-derivative spectrophotometry. Their molar absorptivities are 80 l.mol?1.cm?1 for neodymium and 65 l.mol?1.cm?1 for erbium. Use of the third-derivative spectra, eliminates the interference by other rare earths and increases the sensitivity for Nd and Er. The derivative molar absorptivities are 390 1.mol?1.cm?1 for Nd and 367 1.mol?1.cm?1 for Er. The calibration graphs were linear up to 11.8 μg/ml of Nd and 12.3 μg/ml of Er, respectively. The relative standard deviations evaluated from eleven independent determinations of 7.2 μg/ml (for Nd) and 8.3 μg/ml (for Er) are 1.3% and 1.4%, respectively. The detection limits (signal to noise ratio = 2) are 0.2 μg/ml for Nd and 0.3 μg/ml for Er. The method has been developed for determining those two elements in mixture of lanthanides by means of the third-derivative spectra and the analytical results obtained are satisfactory.  相似文献   

9.
《Analytical letters》2012,45(11):2007-2014
Abstract

A simple and inexpensive method for determining chromium (VI) in drinking water by spectrophotometry after preconcentration with sodium dodecyl sulphate (SDS) coated alumina column is described. Chromium(VI) is reacted with diphenylcarbazide (DPC) and the Cr-DPC complex is quantitatively adsorbed onto a SDS coated alumina column from 800 ml of sample solution. The complex is then eluted with a 8 ml mixture of methanol, acetone and hydrochloric acid and determined by spectrophotometry. Total chromium can be determined after oxidation of chromium (III) to chromium (VI) by KMnO4. The relative standard deviation (10 replicate analyses) at the 10 μg l?1 of chromium (VI) and 10 μg l?1 of total chromium were 3.5% and 3.4% and corresponding limits of detection (based on 3 σ) were 0.040 μg l?1 and 0.033 μg l?1, respectively.  相似文献   

10.
《Analytical letters》2012,45(18):2219-2227
Abstract

A method is described for the spectrophotometric determination of manganese by means of its complex with 4(5)-imidazolealdoxime, IMALOX, formed in alkaline medium. The colour system has its absorption maximum at 350 nm and obeys Beer's law over the range 0.8–8.0 μg of Mn per ml. The optimum range is 1–5 μg m?1. The molar absorptivity is 7850 1 mol?1 cm?1. Relatively few ions interfere, and these can be masked with cyanide, tartrate and NTA. The experimental results have been critically analyzed and a comparison with the main spectrophotometric reagents for manganese is presented.  相似文献   

11.
《Analytical letters》2012,45(4):753-762
Abstract

A sensitive and highly selective spectrophotometric method is described for the determination of 12-120 μg of copper using 6-phenyl-2,3-dihydro-asym-triazine-3-thione (PDTT) as a complexing agent. The red 1:4 water soluble complex was measured at 540nm, ε=1.26×104 1. mol?1cm?1.

The method was applled for the determination of copper in standard steels (B.C.S.) and estimation of the solubility product of copper (I) iodide. Comperison was also made with the 2-2 biquinoline method.  相似文献   

12.
《Analytical letters》2012,45(4):563-581
Abstract

The color reaction between Xylenol orange (XO), zirconium (IV) and fluoride ions in the presence of various surfactants alone or in combination was studied at various pH. The XO -zirconium)IV)-fluoride ion ternary complex in mixed micellar media containing a low concentration of N-hexadecylpyridinium chloride (HPC) as a cationic surfactant and large amounts of (poly{oxyethylene)dodecyl ether (Brij 35) as a nonionic surfactant at weakly acidic media was found to be the most stable, and showed a remarkable bathochromic shift and clear contrast against a reagent blank. The maximum absorbance was at 600 nm in the mixed micellar media at pH 3.5, and the apparent molar absorptivities at 600 nm were 7.0 × 104 1 mol?1 cm?1 for zirconium(IV) and 1.4 × 104 1 mol?1 cm?1 for fluoride ion. The calibration curves covered the ranges of 0.5 ~ 20.0 μg/10 ml zirconium! IV) and 0 ~ 20.0 μg/10 ml fluoride ion with the Sandell sensitivities being 0.0013 μg/cm2 for zirconium(IV) and 0.0016 μg/cm2 for fluoride ion.  相似文献   

13.
《Analytical letters》2012,45(8):1625-1633
ABSTRACT

Aluminium was determined in a weakly alkaline medium by reaction with alizarin at trace level. Flotation of the complex was carried out with heptane, followed by dissolution in N, N-dimethylformamide (DMF) for subsequent spectrophotometric determination. The molar absorptivity was 2.92×105 mol? cm? at 518 run. Beer's law was obeyed in the range 5–80 μg/1 and the detection limit was 0.4μg/l.

The reliability of the procedure was confirmed by determination of a sample of milk with Graphite Furnace Atomic Absorption Spectrophotometric method (GFAAS). The precision and accuracy of the method were both acceptable via F and tests at the 95% confidence level.  相似文献   

14.
A selective Spectrophotometric method has been developed for the trace determination of copper after adsorption of its 1-phenyl-4,4,6-trimethyl(1H, 4H)-pyrimidine-2-thiol (PTPT) complex onto microcrystalline naphthalene. The complex is quantitatively adsorbed on naphthalene in the pH range 7.5–11.5, separated by filtration, dissolved in dimethylformamide (DMF) and determined spectrophotometrically at 400 nm. Beer's law is obeyed in the concentration range 2.5–37.5 g of copper in 10 ml of DMF. The molar absorptivity and Sandell's sensitivity are 1.30 × 1041 · mol–1 · cm–1 and 0.0048g cm–2, respectively. Ten replicate analyses of a solution containing 20.0 g of copper gave a mean absorbance of 0.410 with a relative standard deviation of 0.91 %. The interferences of various ions have been studied and the method has been validated by the determination of copper in various standard reference materials, beers, wines, human hair, goat liver and environmental samples.On leave from St. Stephen's College, Delhi 110 007, India  相似文献   

15.
《Analytical letters》2012,45(7-8):713-723
Abstract

Hafnium(IV) reacts with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol in the pH range 3.3–11.0 to yield a sparingly soluble red-coloured chelate that can be dissolved with Triton X-100. Effect of initial pH of metal ion and order of addition of reagents was studied in detail. The 1:3 complex adheres to Beer's law over the concentration range 0.02–1.12 μg/ml of Hf(IV), has a molar absorptivity 1.33x105 1 mol?1cm?1, Sandell sensitivity 1.3 ng cm?2, formation constant (log K) 11.94 and the method had a relative standard deviation of ± 1.5%. Effect of 60 diverse ions on the determination of hafnium(IV) was studied. This fairly selective method is the most sensitive so far reported for the spectrophotometric determination of hafnium(IV).  相似文献   

16.
Abstract

A new rapid, selective and sensitive method has been developed for the determination of maneb using pyrocatechol-violet(PV) as chelating reagent in the pH range of 7.5–11.0 in the presence of CTAB producing a complex which shows maximum absorption at 640 nm. Working range of the method is 0.2–3.0 μg ml?1 maneb (manganese ethylenebisdithiocarbamate). The molar absorptivity of the color system is 79600 1 mol?1 cm?1 and Sandell's sensitivity is 0.0033 μg cm?2. The reproducibility of the method has been checked by the 10 replicate analysis of 15 μg of maneb in 10 ml of solution. The method is quite sensitive and has been applied for the determination of maneb in various commercial samples, crops, grains and synthetic samples.  相似文献   

17.
《Analytical letters》2012,45(5-6):503-528
Abstract

Ruthenium(III) forms a 1:2 complex with allyl thiourea. Conformity to Beer's law was observed for up to 12 pg/ml of ruthenium, in acidic medium.

The molar absorptivity of the complex is 1.66E+04 1 mol?1 cm?1, at 270 nm; the Sandell's sensitivity of the reaction for ruthenium is 0.0061 μg cm?2 per 0.001 absorbance unit.

The tolerance to diverse ions is quite satisfactory.

The infrared spectra of allyl thiourea and of its ruthenium complex, recorded in the 2.5 - 50 μ region, reveal that only sulphur-to-ruthenium bonds are present in the complex.

A comparison with the main, most recent, spectrophotometric reagents for ruthenium is reported. The present method has the advantages of simplicity and reasonable sensitivity.  相似文献   

18.
《Analytical letters》2012,45(12):2377-2388
Abstract

A sensitive, simple and selective spectrophotometric method for the determination of gadolinium(III) is proposed using o-hydroxyhydroquinonephthalein(Qnph), by analogy with phenylfl-uorone(Phfl), in the presence of N-hexadecylpyridinium chlo-ride(HPC)-Brij 35 mixed surfactants. The calibration curve is rectilinear in the range of 0 – 16.0 μg per 10 ml at 590 nm with an apparent absorption coefficient(?) of 1.2 × 105 1 cm?1 mol?1 and Sandell sensitivity of 0.0013 μg/cm2 gado-linium(III).  相似文献   

19.
《Analytical letters》2012,45(12):2515-2531
ABSTRACT

Propofol is coupled with 2, 6-dichloroquinone-4-chlorimide (DCQ) in a reaction buffered at pH 9.6 to give a colored product having an analytically useful maximum at 635 nm. The factors affecting the color generation were optimized and incorporated in the procedure. The reacted propofol has a molar absorptivity of 3.9 × 10?4 L mol?1 cm?1, and Beer's law is obeyed for concentrations 1-5 μg ml?1 with detection limit 0.25 μg ml?1. The method was found applicable to biological fluids (plasma and urine) spiked with propofol at concentration levels 1-5 μg ml?1 for plasma and 1-5 μg 0.5 ml?1 urine (less sensitivity is obtained with urine volumes above 0.5 ml) with detection limits 0.28 μg ml?1 for plasma and 0.4 μg 0.5 ml?1 urine. The average recovery for the commercial preparation (1% w/v propofol emulsion intravenous injection for infusion) was 99.54% with an RSD of 1.05%. The method was validated by an adopted HPLC method. The results obtained by the HPLC method for the commercial preparation were statistically compared with the proposed method and evaluated at the 95% confidence limits.  相似文献   

20.
《Analytical letters》2012,45(9):1737-1748
Abstract

Isonitroso-4-methyl-2-pentanone (HIMP) is proposed as a new reagent for extraction and photometric determination of Pd(II). The reagent forms a yellow complex with palladium in the pH range 4.0-5.0. The complex extracted into chloroform was measured at 330 nm. The molar absorptivity was found to be 5.37 × 103 1 mol?1 cm?1 and Sandell's sensitivity 20 ng cm?2 Beer's law was obeyed over the concentration range 0.1-10.0 μg/ml of palladium. The method is applicable for palladium estimation in Ores and catalysts.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号