首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
《Analytical letters》2012,45(13):2217-2230
Abstract

(Acetylacetone)‐2‐thiol‐phenyleneimine (H2L) immobilized on an anion‐exchange resin (Dowex) was used for separation and removal of mercury from natural water samples and for preconcentration prior to its determination by cold vapor inductively coupled plasma atomic emission spectroscopy. The metal was eluted from the column using a solution of 10% thiourea in 0.1 M HCl. The modified resin is higly selective with an exchange capacity of 1.60 mmol g?1. Various parameters like pH, column flow rate, and desorbing agents are optimized. The proposed method has a linear calibration range of 15–1000 ng/ml Hg(II), with a relative standard deviation at the 15 ng/ml level of 3.5%. The precision of the method (evaluated as the relative standard deviation obtained after analyzing six series of five replicates) was ±4.2% at the 50 ng/ml level of Hg(II). The method has been used for routine determination of trace levels of mercury species in natural waters. The potential application of modified resin for the removal of mercury(II) from two natural water samples (top water and lake water) spiked with 50 ng/ml of mercury (II) was studied by ICP‐AES, and the results proved that excellent percent extraction of mercury(II) from both natural water samples was obtained by column method using modified resin.  相似文献   

2.
《Analytical letters》2012,45(12):1999-2013
Abstract

A simple, rapid, selective, and sensitive method for the derivative spectrophotometric determination of Hg(II) and its simultaneous determination in the presence of Zn(II) using 2‐(5‐bromo‐2‐pyridylazo)‐5‐diethylaminophenol in the presence of cetylpyridinium chloride, a cationic surfactant, has been developed. The molar absorption coefficient and analytical sensitivity of the 1∶1 Hg(II) complex at 558 nm (λmax) are 5.78×104 L mol?1 cm?1 and 0.67 ng mL?1, respectively. The detection limit of Hg(II) is 1.40×10?2 ng mL?1, and Beer's law is valid in the concentration range 0.05–2.40 µg mL?1. Overlapping spectral profiles of Hg(II) and Zn(II) complexes in zero‐order mode interfere in their simultaneous determination. However, 0.10–2.00 µg mL?1 of Hg(II) and 0.065–0.650 µg mL?1 of Zn(II), when present together, can be simultaneously determined at zero cross point of the derivative spectrum, without any prior separation. The relative standard deviation for six replicate measurements of solutions containing 0.134 µg mL?1 of Hg(II) and 0.620 µg mL?1 of Zn(II) is 1.72 and 1.47%, respectively. The proposed method has successfully been evaluated for trace level simultaneous determination of Hg(II) and Zn(II) in environmental samples.  相似文献   

3.
《Analytical letters》2012,45(6):1211-1228
Abstract

A multi‐element flow injection (FI) system with spectrophotometric detection was developed for sequential determination of Zn(II), Cu(II), Cd(II), Pb(II), and Hg(II). Dithizone reagent was used for the previously mentioned analytes and it was prepared on line by using a solid reagent column (SRC). Bear in mind that the most hazardous elements for environmental contamination are lead, cadmium, and mercury; a multi‐element FI system with preconcentration steps is proposed to determine their trace levels in natural waters. Results obtained for different samples agreed satisfactorily with those obtained by the reference method inductively coupled plasma‐atomic emission spectrometry (ICP‐AES). Detection limits were 5.4, 5.0 and 14 µg L?1 for Cd(II), Pb(II), and Hg(II), respectively. The percent of relative standard deviation (RSD) was better than 4.5% for each one.  相似文献   

4.
Mercury is a highly toxic metal, of which even small doses (<200 ng mL−1) can cause serious problems for humans, plants, animals and microorganisms, including marine species and freshwater organisms. Hence, a simple, fast, highly selective and sensitive and accurate method for the detection of mercury in the environmental, clinical or biological samples is necessary. A new, sensitive and selective method for the determination of Hg(II) with 5 % N1-hydroxy-N1,N2-diphenylbenzamidine modified carbon paste electrode has been developed. Hg(II) was accumulated for 210 s on the surface of the modified electrode using 0.1 M CH3COONa of pH 7 at −0.8 V vs Ag/AgCl, followed by electrochemical stripping with SWASV in 0.1 M NH4Cl at pH 4. The linear range is 0.02–10 μM Hg(II) with limit of detection of 1.28 nM. The method has RSDs of 3.7 %. The method was applied for the determination Hg(II) in five types of water samples. The recoveries were in the range 97.8–103 %. The proposed method was found to be highly selective and sensitive and has many attractive features compared to previous reports such as low cost, simplicity of electrode preparation, long term stability, fast response, easy renewable ability, and reasonable short accumulation time.  相似文献   

5.
《Analytical letters》2012,45(10):1991-2004
ABSTRACT

A method was developed for the preconcentration of copper, nickel and cadmium in water samples, prior to their determination by FAAS, using the Zn-piperazinedithiocarbamate complex (ZnPDC) loaded on activated carbon. In this method, Cu, Ni and Cd in liquid phase quantitatively replaced zinc on a ZnPDC-activated carbon solid phase. Afterwards, the metals on the solid phase were easily eluted by Hg (II) solution into aqueous phase, and were measured by FAAS. The optimum experimental parameters such as pH, sample volume, and effect of matrix ions for the preconcentration of the metals were investigated. The range of linearity 0-6, 0-5, 0-3 μgml?1, correlation coefficient 0.998, 0.996, 0.999, detection limits 15.7, 23.5, 11.8 ngml?1 and determination limits 136, 179, 98 ngml?1 in final Hg(II) solution were obtained for Cu, Ni and Cd, respectively. The proposed method has been employed for the determination of Cu, Ni and Cd in various standard metal alloys and natural water samples.  相似文献   

6.
《Analytical letters》2012,45(9):1735-1747
Abstract

A new chelating resin has been synthesized by introducing a quinaldinic acid amide group into styrenedivinyl benzene (8%) copolymer beads. The resin is stable in fairly strong acids or alkali and has been characterized by elemental analysis for nitrogen and from i.r. spectra. The water regain value is 0.37g/g. The sorption patterns of Na(I), K(I), Ca(II), Mg(II), Pb(II), Cu(II), Ni(II), Zn(II), Cd(II), Hg(II) and Fe(III) on the chelating resin have been studied as a function of pH. The resin selectively sorbs Hg(II) ever a wide pH-range of 2.5–7.6 with high efficiency. The maximum exchange capacity for Hg(II) is 1.98 mmols g?1 at pH 5.5. Over 99% of Hg(II) sorbed has been recovered by using 10% thiourea in 1M HClO4 both by batch and column operations. The has been utilized in the preconcentration and recovery of Hg(II) from industrial and laboratory waste water.  相似文献   

7.
A method for the simultaneous preconcentration and determination of Hg(II) and MeHg(I) at the ng ml−1 level has been developed. This method is based on solid phase extraction using a newly synthesized chelating resin containing nitrogen and sulphur donor sites of the 1,2-bis(o-aminophenylthio)ethane moiety that is very selective for mercury. The characterization of the resin has been carried out by elemental analyses, infrared spectral data, thermogravimetric analysis and metal ion capacities. The resin is highly selective for Hg(II) and MeHg(I) with an exchange capacity of 0.38 and 0.30 mmol g−1, respectively. Various parameters like pH, column flow rate, desorbing agents are optimized. Cold vapour atomic absorption spectrometry (CVAAS) was used to measure the concentration of both species of mercury. The calibration graph was linear upto 10 ng ml−1 with a 3σ detection limit of 0.09 ng ml−1. The recovery of Hg(II) and MeHg(I) was found to be 98.9±2.0 and 98.0±1.1%, respectively. The method has been used for routine determination of trace levels of mercury species in natural waters to comply with more stringent regulations.  相似文献   

8.
A rapid method has been developed for the determination of mercury in environmental samples by thermal neutron activation analysis. Radiochemical separation involves the extraction of Hg/II/ with substoichiometric amounts of 2-mercaptobenzothiazole /2-HMBT/ into chloroform1. The time required for radiochemical purification and counting of two samples and a standard is about 2 h. Water, sludge and IAEA standard samples were analyzed for Hg concentration by this method.  相似文献   

9.
A new and efficient Hg(II) back-elution method for the desorption of Cd, Cu, and Pb from Chelex-100 chelating resin was developed. A smaller eluent volume and shorter elution time can be achieved using an Hg(II) containing eluent rather than pure nitric acid. Owing to the remaining Hg(II) ion in the effluent, a mercury thin-film electrode is formed in-situ during the anodic stripping voltammetric determination without any further addition of Hg(II). The results indicate that all the analytes in seawater matrix can be completely adsorbed on Chelex-100 resin from the sample at pH 6.5, and subsequently eluted from the resin with an acid solution of 5 × 10–4 mol/L Hg2+ + 1 mol/L HClO4. The detection limits obtained from the differential-pulse anodic (μg L–1 to ng L–1) stripping voltammetry are at sub-ppb to ppt (μg L–1 to ng L–1) levels permitting to determine Cd, Cu and Pb traces in seawater. The analytical reliability was confirmed by the analysis of the certified reference material CASS-II (open ocean seawater). Received: 22 April 1997 / Revised: 5 August 1997 / Accepted: 7 August 1997  相似文献   

10.
A new method for solid-phase extraction and preconcentration of trace amounts Hg(II) from environmental samples was developed by using sodium dodecyle sulphate-coated magnetite nanoparticles (SDS-coated Fe3O4 NPs) as a new extractant. The procedure is based on the adsorption of the analyte, as mercury-Michler's thioketone [Hg2(TMK)4]2+ complex on the negatively charged surface of the SDS-coated Fe3O4 NPs and then elution of the preconcentrated mercury from the surface of the SDS-coated Fe3O4 NPs prior to its determination by flow injection inductively coupled plasma-optical emission spectrometry. The effects of pH, TMK concentration, SDS and Fe3O4 NPs amounts, eluent type, sample volume and interfering ions on the recovery of the analyte were investigated. Under optimized conditions, the calibration curve was linear in the range of 0.2-100 ng mL−1 with r2 = 0.9994 (n = 8). The limit of detection for Hg(II) determination was 0.04 ng mL−1. Also, relative standard deviation (R.S.D.) for the determination of 2 and 50 ng mL−1 of Hg(II) was 5.2 and 4.7% (n = 6), respectively. Due to the quantitative extraction of Hg(II) from 1000 mL of the sample solution an enhancement factor as large as 1230-fold can be obtained. The proposed method has been validated using a certified reference materials, and also the method has been applied successfully for the determination of Hg(II) in aqueous samples.  相似文献   

11.
A novel chelating resin (poly-Cd(II)-DAAB-VP) was prepared by metal ion imprinted polymer (MIIP) technique. The resin was obtained by one pot reaction of Cd(II)-diazoaminobenzene-vinylpyridine with cross-linker ethyleneglycoldimethacrylate (EGDMA). Comparing with non-imprinted resin, the poly-Cd(II)-DAAB-VP has higher adsorption capacity and selectivity for Cd(II). The distribution ratio (D) values for the Cd(II)-imprinted resin show increase for Cd(II) with respect to both D values of Zn(II), Cu(II), Hg(II) and non-imprinted resin. The relatively selective factor (αr) values of Cd(II)/Cu(II), Cd(II)/Zn(II) and Cd(II)/Hg(II), are 51.2, 45.6, and 85.4, which are greater than 1. poly-Cd(II)-DAAB-VP can be used at least 20 times without considerable loss of adsorption capacity. Based on poly-Cd(II)-DAAB-VP packed columns, a highly selective solid-phase extraction (SPE) and preconcentration method for Cd(II) from aqueous solution was developed. The MIIP-SPE preconcentration procedure showed a linear calibration curve within concentration range from 0.093 to 30 μg l−1. The detection limit and quantification limit were 0.093 and 0.21 μg l−1 (3σ) for flame atomic absorption spectrometry (FAAS). The relative standard deviation of the eleven replicate determinations was 3.7% for the determination of 10 μg of Cd(II) in 100 ml water sample. Determination of Cd(II) in certified river sediment sample (GBW 08301) demonstrated that the interfering matrix had been almost removed during preconcentration. The column was good enough for Cd(II) determination in matrixes containing components with similar chemical property such as Cu(II), Zn(II) and Hg(II).  相似文献   

12.
A novel UV-VIS spectrophotometric method was developed in this study by using solid phase extraction procedure for the simultaneous preconcentration, separation and determination of trace levels of Pb (II), Cd (II) and Zn (II) ions in various water samples by using Amberlite N,N-bis(salicylidene)cyclohexanediamine (SCHD) resin. This study presents the results of experimental procedures carried out like the adsorption of analytes to the resin, influences of some analytical parameters that effect the recovery such as pH, sample volume, sample flow rate, eluent type and concentration, eluent volume, eluent flow rate and the effects of alkaline metals, earth alkaline metals and some other transition metals. The analytes in the samples with the adjusted pH range of 4–7 were adsorbed on XAD-4-SCHD resin and eluted by using 1.0 mol L?1 nitric acid. The amounts of ions were determined by using UV-VIS spectrometer. The limits of detection were 0.03, 0.07 and 0.05 µg mL?1 for Pb (II), Cd (II) and Zn (II), respectively. The accuracy of the method was assured by the analysis of the certified standard water sample NW-TMDA-70.2 and the observed recoveries were above 93%. Different environmental water samples that contain trace amounts of Pb (II), Cd (II) and Zn (II) were analysed by using the method developed in this study. Same samples were also analysed by ICP-MS for comparison and almost the similar results were observed. The method developed in this study was successfully applied to the various environmental water samples to determine the trace levels of Pb (II), Cd (II) and Zn (II) ions.  相似文献   

13.
We have developed a surface-enhanced Raman scattering (SERS) probe for the determination of mercury(II) using methimazole-functionalized and cyclodextrin-coated silver nanoparticles (AgNPs). These AgNPs in pH 10 solution containing sodium chloride exhibit strong SERS at 502 cm?1. Its intensity strongly decreases in the presence of Hg(II). This effect serves as the basis for a new method for the rapid, fast and selective determination of trace Hg(II). The analytical range is from 0.50 μg L?1 to 150 μg L?1, and the limit of detection is 0.10 μg L?1. The influence of 11 metal ions commonly encountered in environmental water samples was found to be quite small. The method was applied to the determination of Hg(II) in spiked water samples and gave recoveries ranging from 98.5 to 105.2 % and with relative standard deviations of <3.5 % (n?=?5). The total analysis time is <10 min for a single sample.
Figure
A high-sensitive SERS probe for the determination of Hg2+ using methimazole-functionalized cyclodextrin-protected AgNPs was designed. The limit of detection is 0.10 μg L?1.  相似文献   

14.
Summary A procedure for determining Hg(II) in water has been worked out. The cation reacts with bromine and fluorescein to form an ionic pair (ionic association) which is extracted with n-butyl acetate, and has an emission peak at 476 nm and an excitation peak at 452 nm. On optimum determination conditions, the detection limit was 0.4 ng ml–1 and the linear range 1–20 ng ml–1. The influence of different chemical species present in water samples was studied and the method was applied to determine Hg(II) in synthetic samples of water and in natural water with good recovery rates. In order to determine Hg(II) in samples of urban waste water, a simple pretreatment with HNO3 is required. The method can be used to monitor Hg(II) contamination in water.  相似文献   

15.
A sensitive and selective method has been developed for the determination of chromium in water samples based on using cloud point extraction (CPE) preconcentration and determination by flame atomic absorption spectrometry (FAAS). The method is based on the complexation of Cr(III) ions with Brilliant Cresyl Blue (BCB) in the presence of non-ionic surfactant Triton X-114. Under the optimum conditions, the preconcentration of 50 mL of water sample in the presence of 0.5 g/L Triton X-114 and 1.2 × 10−5 M BCB permitted the detection of 0.42 μg/L chromium(III). The calibration graph was linear in the range of 1.5–70 μg/L, and the recovery of more than 99% was achieved. The proposed method was used in FAAS determination of Cr(III) in water samples and certified water samples. In addition, the developed CPE-FAAS method was also used for speciation of the inorganic chromium species after reduction of Cr(VI) to Cr(III) using a thiosulphate solution of 120 mg/L in the presence of Hg(II) ion as a stabilizer.  相似文献   

16.
Abstract

Methods for the determination of (1) total organic mercury (Hg) using an extraction +neutron activation analysis, (2) the sum of methyl-Hg+phenyl-Hg using 131I?-Cl? exchange and (3) methyl-Hg using two different Westöö modifications, have been compared. Sample materials were 8 falcon livers, 5 pike livers and 2 pike muscles. Although differences were found between the methods, interaction effects caused by either sample inhomogeneity or bad performance of the analytical methods impeded a clear interpretation of the comparison. Total Hg in the samples was determined by neutron activation analysis (NAA) and atomic absorption spectrometry. The accuracy of the total Hg determination using NAA was verified by the analysis of certified reference material.

In addition to the other organic Hg determinations phenyl-Hg was determined separately in some of the samples by an isotope exchange method using 203Hg2+.

The main conclusion of the study was that there is a demand for reference materials certified for at least total organic Hg and methyl-Hg.  相似文献   

17.
A simple and sensitive kinetic method for the determination of traces of mercury (70-760 ng ml−1) based on its inhibitory effect on the addition reaction between methyl green and sulfite ion is proposed. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of methyl green at 596 nm between 2 and 4 min using a fixed time method. Artificial neural networks with back propagation algorithm coupled with an orthogonal array design were applied to the modeling of the proposed kinetic system and optimization of experimental conditions. An orthogonal design was utilized to design the experimental protocol, in which pH, concentration of sulfite, temperature, and concentration of methyl green were varied simultaneously. Optimum experimental conditions in term of sensitivity were generated by using ANNs. The rate of decrease in absorbance is inversely proportional to the concentration of Hg(II) over entire concentration range tested (100-550 ng ml−1) with a detection limit of 45 ng ml−1 and a relative standard deviation at 200-400 ng ml−1 Hg(II) of 3.2% (n=5). A simple preconcentration step improved the limit of detection and linear dynamic range of the method to about 8 and 12-760 ng ml−1, respectively, by about 10 times enrichment of mercury between 12 and 75 ng ml−1. The method was based on enrichment of Hg(II) from dilute samples on an anionic ion exchanger fixed on a plastic strip and was applied to the determination of Hg(II) in environmental samples with satisfactory results.  相似文献   

18.
《Analytical letters》2012,45(14):2365-2375
Abstract

A sensitive and selective spectrophotometric method is proposed for the rapid determination of cadmium(II) using, p,p′‐dinitro‐sym‐diphenylcarbazid, directly in aqueous solution. The reaction between cadmium(II) and p,p′‐dinitro‐sym‐diphenylcarbazid occurs immediately in strong basic media (0.02 N sodium hydroxide solution). The complex shows a maximum of absorption at 630–640 nm, and the absorbance remains stable for at least 24 h. The method allows the cadmium determination over the range 0.5–6.0 µg mL?1, with a molar absortivity of 2.05×104 L mol?1 cm?1 and features a detection limit of 0.13 ppm. The interferences caused by several ions [Ca(II), K(I), Ba(II), Al(III), Pb(II), Zn(II), Cl?1, NO3 ?, SO4 2?], which are present in most of environmental samples, were determined. The validation of the spectrophotometric method was done by recovery test of cadmium(II) in tap water and sea water. The results show that the proposed method has been successfully applied to the determination of cadmium(II) in water samples.  相似文献   

19.
Immobilization of β-cyclodextrin on Dowex resin as an insoluble polymeric matrix by covalent bond presents a new solid-phase medium for preconcentration of Pb (II) at trace level in environmental samples prior to its flame atomic absorption spectrometric determination. The method is based on the sorption of lead after passing on modified Dowex sorbent in a column. The effect of several parameters such as pH, flow rate of sample, eluent kind and volume was investigated. The sorption capacity of the matrix has been found to be 0.4996?mg?g?1 of adsorbent with the preconcentration factor of 250 for Pb (II). Nitric acid (3 M) as an eluent was sufficient to obtain quantitative recovery (>95%) for Pb (II). The optimum flow rate was 10?ml?min ?1. The calibration curve was linear in the range of (3–250?ng?mL?1) with a correlation coefficient of 0.9995. The limit of detection (LOD) based on three times the standard deviation of the blank was 1.37?ng?mL?1. The relative standard deviation (RSD) for determination of 10?ng?mL?1 and 100?ngmL?1 of Pb (II) was 3.00 % and 0.58 % (n?=?10), respectively. The method was successfully applied to determination of lead in some environmental samples such as tap water, river water, soil and rice.  相似文献   

20.
To develop an accurate and precise method for separation and pre-concentration of Hg(II), a novel thionin functionalised core shell structure magnetic material has been prepared and characterised. The extraction ability of the material was evaluated by magnetic solid-phase extraction coupled with inductively coupled plasma mass spectrometry determination of Hg(II) in food and water samples. Combining the advantages of magnetic separation with selective extraction of thionin towards Hg(II), the material exhibits enhanced enrich selectivity and efficiency for Hg(II). The experimental parameters influencing Hg(II) extraction efficiency, including pH of the aqueous solution, the dosage of the adsorbent, extraction time and sample volume, were systematically investigated. Under the optimised conditions, concentration of Hg(II) at 1.0 μg L?1 can be successfully enriched by the material without the interference of the common co-existing ions. The enrichment factor and adsorption capacity were 250 and 75.2 mg g?1, and precise of the method was confirmed by analysing the spiked food, water samples and standard water reference samples with the recoveries of 92.5–101.8%.  相似文献   