首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
Abstract

A high performance liquid chromatographic [HPLC] method that involves the use of a silica gel column and an aqueous mobile phase for quantitation of chlorpheniramine in plasma and urine is presented. Alkalinized samples are cleaned by extraction with pentane [containing 1% CH3CN], and the extraction is followed by evaporating the solvent and reconstituting the residue in a small amount of mobile phase. An aliquot of this solution is analyzed by an HPLC system with an Ultrasphere Si Column, an aqueous mobile phase at pH 7 containing 60% CH3CN and 7.5 mM [NH4]2HPO4, and UV detection at 200 nm. Although the average recovery of extraction is 58% ± SD 10%, the detection limit for the method is 0.7 ng/ml in plasma and 100 ng/ml in urine [s/n = 3] for 0.5 ml samples. The coefficients of variation [CV] on the results of samples run to measure interday and intraday precision and the bias on control samples were all 10% or less. We have used the method in a bioavailability study of a controlled release formulation involving over 1000 samples.  相似文献   

2.
Abstract

A sensitive and specific reverse phase HPLC method employing a simple sample preparation procedure and utilizing an internal standard was developed to measure the new antitumor agent AZQ in biological fluids. A single chloroform extraction gave drug recoveries of greater than 88% from plasma, urine and CSF in the range of expected physiological concentrations (20–800 ng/ml). Isocratic reverse phase HPLC with UV detection at 340 nm resulted in a limit of quantisation of 5 ng/ml although smaller amounts of the drug could be detected. This assay was successfully applied to determine the single dose plasma pharmacokinetics of AZQ in rats. The potential of this method for determining AZQ disposition and pharmacokinetics in human subjects was demonstrated by analysis of patient CSF.  相似文献   

3.
Abstract

An easy to perform, specific, reproducible and sensitive high performance liquid chromatographic (HPLC) method to measure pyridostigmine concentration in human plasma was developed and validated. Sample clean-up consists of ion-pair extraction into dichloromethane in the presence of neostigmine as internal standard, followed by back extraction into an aqueous phase. Mean recovery of 110% (with a standard deviation of 10%) was determined for concentrations of 5 – 100 ng/ml. Chromatography on a 125·4 mm CN-propyl column using a mobile phase composed of 10% acetonitrile in 3.5×10?4M NaH2PO4 and UV detection at 270 nm, yields clean chromatograms without any interferences from endogenous plasma components. Using 1 ml plasma samples the method has a limit of detection (LD) of 3 ng/ml, with %CV (precision) and bias (accuracy) ≥ 10% for concentrations in the range of 0–100 ng/ml. The method is being used in human pharmacokinetic studies of oral dosage forms of pyridostigmine.  相似文献   

4.
《Analytical letters》2012,45(10):805-816
Abstract

A sensitive and specific high performance liquid chromatographic (HPLC) assay for the determination of saccharin in plasma and urine was developed. Saccharin is extracted into diethyl ether at acid pH, evaporated, and reconstituted prior to instrumental analysis. Overall recovery of saccharin is 86.9 + 8.6% and the sensitivity limits of detection is 0.15 μg per ml of plasma or urine using a fluorescence detector. The sensitivity limit in plasma can be extended to 20 ng per ml by use of a 2 ml assay volume and detector attenuation. The assay was used for the determination of saccharin in plasma and urine of rats following oral doses of 5 mg/kg.  相似文献   

5.
Abstract

On mixing organic solutions of [Et2PS2]M/n and [Prop2PS2]M/n [M=Pd(II), Pt(II), Rh(III), lr(III), Cr(III)] an equilibrium is obtained containing statistical amounts of the corresponding mixed ligand complexes as can be shown by 31P{1H}-NMR, HPLC and FD-MS. With Pt(II)- and Pd(II)-chelates the kinetics of ligand exchange was determined by HPLC. Mixed complexes ML2L′ and MLL′2 were isolated from the equilibrium solutions in case of the more inert Cr(III)-, Rh(III)- and lr(III)-chelates by preparative HPLC. Pd(II), Pt(II) and Rh(III) can be determined quickly and simultaneously in aqueous solutions at nanogramm level by complexation with Et2PS2? in a modified sample loop followed by reversed phase HPLC.  相似文献   

6.
Abstract

A reversed-phase high-performance liquid chromatographic (HPLC) method with UV detection was developed for quantifying chlormezanone in plasma and urine. an extraction step was needed to avoid endogenous interferences especially in urines and led to an average recovery of 90%. the sensitivity limit was 20 ng/ml in both plasma and urine. the method was reproducible with intra- and inter-assay coefficients of variations below 5%. This method was applied to the determination of plasma and urine levels during a pharmacokinetic study in the elderly. It was found suitable to follow the concentrations as long as 120 h after a single oral administration of 400 mg chlormezanone.  相似文献   

7.
Abstract

A simple, rapid and sensitive method for measuring methylphenidate in human plasma by HPLC has been developed. After the addition of the internal standard, ethylphenidate, the two compounds are extracted under basic conditions. The residue obtained is resuspended in acetonitrile and analysed on an ODS reversed phase column with detection by UV absorbance at 192 nm. The limit of sensitivity is 5 ng/ml and the procedure is linear over the 5–50 ng/ml concentration range.  相似文献   

8.
《Analytical letters》2012,45(6):1125-1135
Abstract

A HPLC method has been developed to determine the concentrations of SAZ-VII-23 (3-benzoyl-7-isopropyl-3,7-diazabicyclo[3.3.1]nonane HClO4), a novel antiarrhythmic agent, in dog plasma and urine. Plasma treated with acetonitrile and alkalinized urine were extracted with chloroform- propanol (9:1). An aliquot was injected on to HPLC system using a C6 reversed-phase column and acetonitrile-methanol-37.5 mM phosphate buffer, pH 6.8 (28.5:28.5:43 v/v) containing 4.0 mM triethylamine as mobile phase. Detection wavelength was 255 nm. The linear range were 0.04–8 μg/ml, and the lower limit of quantitation was 0.04 μg/ml in plasma and urine, respectively. The method was applied to determine plasma and urine concentrations and preliminary pharmacokinetic profiles of SAZ-VII-23 in a dog.  相似文献   

9.
We present data for a comparison of a liquid-chromatographic method coupled with tandem mass spectrometry (LC-MS/MS) and a high-performance liquid-chromatographic method with column switching and UV spectrophotometric detection. The two methods were developed for determination of naltrexone and 6β-naltrexol in blood serum or plasma aiming to be used for therapeutic drug monitoring to guide the treatment of patients with naltrexone. For the high-performance liquid chromatography (HPLC)/UV detection, online sample cleanup was conducted on Perfect Bond C18 material with 2% (vol/vol) acetonitrile in deionized water. Drugs were separated on a C18 column using 11.5% (vol/vol) acetonitrile and 0.4% (vol/vol) N,N,N,N-tetramethylethylenediamine within 20 min. LC-MS/MS used naltrexone-d 3 and 6β-naltrexol-d 4 as internal standards. After protein precipitation, the chromatographic separation was performed on a C18 column by applying a methanol gradient (5–100%, vol/vol) with 0.1% formic acid over 9.5 min. The HPLC/UV method was found to be linear for concentrations ranging from 2 to 100 ng/ml, with a regression correlation coefficient of r 2?>?0.998 for naltrexone and 6β-naltrexol. The limit of quantification was 2 ng/ml for naltrexone and 6β-naltrexol. For the LC-MS/MS method the calibration curves were linear (r²?>?0.999) from 0.5 to 200 ng/ml for both substances, and the limit of quantification was 0.5 ng/ml. The concentrations measured by the two methods correlated significantly for both substances (r²?>?0.967; p?<?0.001). Both methods could be used for therapeutic drug monitoring. The HPLC/UV method was advantageous regarding automatization and costs, whereas LC-MS/MS was superior with regard to sensitivity.  相似文献   

10.
Abstract

A high-performance liquid chromatographic method for the analyses of ciprofloxacin (BAY o 9867) (1-cyclopropyl-6-fluoro-1,4-dihydro-4-oxo-7-(1-piperazinyl)-3-quinoline carboxylic acid hydrochloride) in human serum, plasma and urine samples is described. Diluted serum, plasma, and urine samples are injected onto a RP-18 column without prior extraction or clean-up procedure. Ciprofloxacin is separated from the ballast by an eluent consisting of an 0.025M H3PO4 solution adjusted to pH=3 with tetrabutylammonium hydroxide and acetonitrile.

Ciprofloxacin is detected fluorimetrically giving a detection limit of 8ng/ml in plasma and serum and of 50ng/ml in urine. A statistical evaluation of the assay showed acceptable accuracy and precision for 10 to 500ng of BAY o 9867 per ml in serum and plasma and for 50ng to 600ng of BAY o 9867 per ml of diluted urine specimens. This method was used to monitor the concentrations of BAY o 9867 in serum, plasma and urine of volunteers after oral administration of ciprofloxacin.  相似文献   

11.
《Analytical letters》2012,45(7):1245-1263
Abstract

Sensitive and simple second derivative UV spectrophotometric and HPLC with fluorometric detection methods were developed for cycloserine based on derivatization with 9-chloro-10-methyl acridinium triflate (CMAT) to yield a reaction product which absorbs in the UV at 361 nm and is fluorescent using excitation and emission wavelengths of 257 nm and 475 nm, respectively. The CMAT derivatization reaction takes 30 minutes at 70°C. Cycloserine was linear in the 0.3 – 5.0 μg/ml range (r=0.999, n=5) for the second derivative UV method and the 0.8 – 5 μg/ml range for the HPLC method (r=0.999, n=5). The limit of detection for cycloserine in the HPLC method can be improved to 0.15 μg/ml with the addition of glacial acetic acid to the analytical sample. The HPLC assay was applied to the determination of cycloserine in spiked human urine samples. The correlation coefficient (r) was in the 0.999 range and sensitivity was at the low pg/ml level.  相似文献   

12.
《Analytical letters》2012,45(6):1499-1512
Abstract

A stability-indicating HPLC analytical method has been developed for the determination of the H2-receptor antagonist, famotidine in the presence of its degradation products. the method utilizes reversed phase chromatography with UV detection and internal calibration techniques. the mobile phase was comprised of 84% ammonium acetate buffer (pH 2.9) and 16% acetonitrile and pumped at a flow rate of 1.5 ml/min. Quantitation was performed by measuring the peak height ratio of drug to internal standard (salicylic acid). the limit of famotidine detection was determined to be 10 ng (0.4 ug/ml) with a signal to noise ratio of 3:1. Within day coefficient of variation of the method was 2.22% (2.5 μg/ml) and 0.82% (10 μg/ml). Between day coefficient of variation based on the slopes of daily prepared standard curves was 4.70%. the developed method was used to determine the drug content of famotidine tablets. Further, it was used to investigate the kinetics of degradation of the drug in an acidic solution.  相似文献   

13.
Abstract

A sensitive HPLC method with minimal sample preparation and good reproducibility for the determination of furosemide in plasma and urine is described. Acidified plasma samples were extracted using CH2Cl2 containing desmethylnaproxen as internal standard (IS). Fresh urine samples were incubated with β-gluc-uronidase for 15 minutes and then treated with CH3CN containing IS.

Chromatography was performed on a C18 column with 10 mcl sample injection, Mobile phases were: a) for plasma: 0.01 M NaH2PO4, pH 3.5 - CH3OH (65:35), and b) for urine: acetic acid, pH 3.5 - CHS3OH (60:40) at 3 ml/min and fluorescence detection at Ex 235/Em 389 nm. The plasma standard curve was linear from 0.01 to 15.0 mcg/ml and the urine from 0.5 to 200.0 mcg/ml. The within run CV's were 3,2% at 0.74 mcg/ml plasma and 2.0% at 10.7 mcg/ml urine. Recovery from plasma was 69.9% at 2.0 mcg/ml and 98.6% from urine at 5.0 mcg/ml. The stability of furosemide and its glucuronide were studied. Both methods have been applied to the analysis of plasma and urine samples obtained from human volunteers.  相似文献   

14.
《Analytical letters》2012,45(12):941-949
Abstract

An HPLC method for analysis of atenolol in human plasma and urine is presented. Based on alkaline extraction, acid backextraction and reverse phase ion-pair chromatography this method is quite specific for atenolol. For a 0.5 ml plasma sample the sensitivity ranges from 20 ng/ml in fasted healthy volunteers to 50 ng/ml in various groups of patients. A sensitivity in urine of 1.0 mcg/ml was sufficient for all samples studied. As presented this method has been used in several clinical pharmacokinetic studies involving hundreds of samples.  相似文献   

15.
Abstract

A high performance liquid chromatographic (HPLC) technique has been developed for the determination of bupropion hydrocloride (Bup) in human plasma, using a reversed-phase method, with UV detection at 250 nm.

The internal standard 5-(P-methylphenyl)-5-phenylhydantoin (MPPH), was used as an aid to quantitation. The plasma was deprotemized with acetonitrile and the clear supernatant was directly injected in the chromatographic system. The lower limit of quantitation was 5.0 ng/ml using only 100 μl of plasma sample.

Linear regression analysis for the calibration plots obtained on five different days over a two-week period for the the two ranges used (10–250 ng/ml and 250–2000 ng/ml) in plasma indicated excellent linearity and reproducibility. The mean recovery of spiked Bup in plasma samples over the concentrations studied was found 96.5 ± 3.14%.

The method revealed that more than 30% of Bup was lost when the supernatant was stored at room temperature for 24 hrs.  相似文献   

16.
Khuhawar MY  Arain GM 《Talanta》2005,66(1):34-39
Spectrophotometric and high performance liquid chromatographic (HPLC) methods have been developed for the determination of cis-platin and carboplatin based on the pre-column derivatization of platinum(II) with 2-acetylpyridine-4-phenyl-3-thiosemicarbazone. The complex was extracted in chloroform with molar absorptivity of 2.2 × 104 L mol−1 cm−1 at 380 nm. The complex eluted from a Phenomenex C-18 (150 mm × 4.6 mm i.d.) column with methanol:water:acetonitrile:tetrabutyl ammonium bromide (1 mM) (44:30:25:1, v/v/v/v) with a flow rate of 1 ml/min and UV detection at 260 nm. Ruthenium(IV) and selenium(IV) also separated completely. The linear calibration curve was with 0.5-12.5 μg/ml and detection limit of 10 ng/ml platinum(II).The analysis of cis-platin and carboplatin injections by spectrophotometric and HPLC methods indicated relative standard deviation (R.S.D.) of 0.66-2.1%. The method was used for the determinations of cis-platin in serum and urine of cancer patients after chemotherapy and platinum contents were found 148-444 and 50-90 ng/ml with R.S.D. of 0.3-3.0 and 0.6-2.4% for the serum and urine, respectively. The recovery of platinum(II) from serum was 97% with R.S.D. 2.2%.  相似文献   

17.
Abstract

A rapid method for the simultaneous quantitation of the H2-receptor antagonist drugs cimetidine and ranitidine in human plasma by isocratic ion-pair reverse-phase HPLC is described. The method involves a simple organic extraction step of the alkalinized plasma containing added internal standard followed by back extraction of the extract with dilute acetic acid and subsequent analysis of the aqueous acidic phase on a reverse-phase (C18) column. The eluting solvent was acetonitrile-water (20:80 v/v) containing 0.005 mole/litre octanesulphonic acid and was monitored at 229 nm. The run time for the assay was 12.5 minutes, with a detection limit for cimetidine of 50 ng/m1/(0.2 μmole/1) and that for ranitidine was 20 ng/ml (0.06 umole/1).  相似文献   

18.
Abstract

A recent outbreak of poisoning resulting from the consumption of cultured blue mussels (Mytilus edulis L.) from a localized area in Eastern Canada has been attributed to the presence of domoic acid (1), a relatively rare neurotoxic amino acid, previously found only in some algae of the family Rhodomelaceae. Studies on aqueous extracts of shellfish tissue indicated that the toxin and several of its isomers could be separated (and isolated in sufficient amounts for subsequent structural identification) by reversed-phase high-performance liquid chromatography (HPLC) with ultraviolet (UV) diode array detection (DAD). Aqueous acetonitrile containing 0.1% v/v trifluoroacetic acid was used as mobile phase. As the retention time and characteristic UV absorption spectrum of 1max = 242 nm) permit unequivocal identification, the HPLC-DAD procedure was refined with a microbore column to provide a rapid (5 min), sensitive (0.3 ng detection limit) and reproducible assay method for the determination of 1 in shellfish tissue. Extraction was accomplished by boiling homogenized shellfish tissue for 5 min with distilled water. Extracts were taken through an octadecylsilica solid phase extraction clean-up prior to HPLC. This method has been applied to a variety of shellfish and phytoplankton samples.

BRIEF

Reversed-phase HPLC with ultraviolet diode array detection was used to analyze shellfish tissue and phytoplankton extracts for domoic acid. A rapid (5 min) and sensitive (0.3 ng detection limit) assay is presented.  相似文献   

19.
Abstract

Adenine compounds can be measured in picomole amounts using liquid chromatography of the fluorescent 1, N6-etheno derivatives. The limit of detection for the etheno derivatives in tissue extracts, however, is tissue-dependent due to interference by nucleotides and fluorescent components which are normally present. Prior to derivatization nucleotides were partially removed from extracts of lymphocytes and erythrocytes by treatment with Dowex AG1-X2 anion exchange resin. Samples were analyzed using either a Partisil PXS 10/25 SCX column eluted with 100 mM NH4H2PO4, pH 4.5, at a flow rate of 2 ml/min; or using two μBondapak/C18 reversed-phase columns eluted with 5 mM KH2PO,4:25% methanol (V/V) pH 7.5, at a flow rate of 1 ml/min. Adenosine was found to be 0.07 nmole/ml in normal adult human plasma. The urine of a child with severe combined immunodeficiency disease associated with absence of adenosine deaminase contained a normal amount of adenosine (5–6 nmole/ml), but contained a high level (~60 nmole/ml) of deoxyadenosine. Deoxyadenosine was not detected (<0.01 nmole/ml) in normal adult urine. Because of its sensitivity and selectivity, this method of analysis should be applicable to studies of the physiological roles of adenine compounds.  相似文献   

20.
《Analytical letters》2012,45(11):2073-2081
Abstract

A chemiluminescence analysis has been developed for the determination of formaldehyde based on its inhibition of the chemiluminescence reaction of lucigenin-C10?-H2o2. The method is sensitive, convenient and selective with a detection limit of 0.05ng/ml. The linear dynamic range is 1.0ng/ml to 0.1 μg/ml. The variation coefficient of ten determinations for 2.Ong/ml formaldehyde is 1.2%. Applications to the trace determination of formaldehyde in industrial waste waters are discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号