Nafion covered core–shell structured Fe3O4@graphene nanospheres (GNs) modified glassy carbon electrode (GCE) was successfully prepared and used for selective detection dopamine. Firstly, the characterizations of hydro-thermal synthesized Fe3O4@GNs were investigated by scanning electron microscopy (SEM), transmission electron microscopy (TEM) and Raman spectroscopy. Then Fe3O4@GNs/Nafion modified electrode exhibited excellent electrocatalytic activity toward the oxidations of dopamine (DA). The interference test showed that the coexisted ascorbic acid (AA) and uric acid (UA) had no electrochemical interference toward DA. Under the optimum conditions, the broad linear relationship was obtained in the experimental concentration from 0.020 μM to 130.0 μM with the detection limit (S/N = 3) of 0.007 μM. Furthermore, the core–shell structured Fe3O4@GNs/Nafion/GCE was applied to the determination of DA in real samples and satisfactory results were got, which could provide a promising platform to develop excellent biosensor for detecting DA.  相似文献   

2.
氮掺杂碳纳米管修饰电极的电化学行为   总被引:1,自引:0,他引:1  
董俊萍  曲晓敏  王利军  王田霖 《化学学报》2007,65(21):2405-2410
制备了氮掺杂改性的碳纳米管, 并用循环伏安法(CV)测定了多巴胺(DA)和抗坏血酸(AA)在不同氮含量的碳纳米管修饰电极上的电化学行为. 结果表明, 氮掺杂碳纳米管修饰电极对AA和DA有不同的电催化行为, 其中高氮含量修饰电极对AA的催化作用强, 而低氮含量修饰电极对DA的催化作用强. 微分脉冲伏安法(DPV)的结果显示, DA的氧化峰电流与其浓度在5.0×10-6~2.0×10-4 mol/L范围内呈良好的线性关系, 检出限达1.64×10-6 mol/L (S/N=3); AA氧化峰电流与其浓度在3.0×10-5~1.0×10-2 mol/L范围内呈良好的线性关系, 检出限达3.26×10-6 mol/L (S/N=3). 该修饰电极在AA大量存在(AA浓度为DA浓度两万倍)时可选择性地实现多巴胺的测定而不造成干扰.  相似文献   

3.
《Electroanalysis》2004,16(10):860-865
The electrocatalytic oxidation of sulfite has been studied on the cobalt pentacyanonitrosylferrate modified glassy carbon electrode (CoPCNF). The CoPCNF films on the glassy carbon electrodes show an excellent electrocatalytic activity toward the oxidation of sulfite in 0.5 M KNO3. The kinetics of the catalytic reaction was investigated by using cyclic voltammetry, rotating disk electrode (RDE) voltammetry and chronoamperometry. The average value of the rate constant, K, for the catalytic reaction and the diffusion coefficient, D, were evaluated by different approaches for sulfite and found to be 2.9×102 M?1s?1 and 4.6×10?6 cm2s?1, respectively. At a fixed potential under hydrodynamic conditions (stirred solutions), the oxidation current is proportional to the sulfite concentration and the calibration plot was linear over the concentration range 5×10?6–1×10?4 M. The detection limit of the method is 3×10?6 M., low enough for the trace sulfite determination.  相似文献   

4.
A graphite nanosheet (GNS)‐Nafion modified glassy carbon (GC) electrode was prepared and used for highly sensitive and selective determination of dopamine (DA). The GNS‐Nafion/GC electrode displayed excellent electrocatalytic activities towards DA and ascorbic acid (AA). The selective determination of DA was carried out successfully in the presence of AA by differential pulse voltammetry. High sensitivity (3.695 μA μM?1) and low detection limit (0.02 μM, S/N=3) for the DA detection were obtained. These good properties can be attributed to a large amount of edge plane defects presented on GNSs and the charge‐exclusion and concentration features of Nafion.  相似文献   

5.
A sensitive and selective electrochemical method for the determination of dopamine (DA) was developed using a 4‐(2‐Pyridylazo)‐Resorcinol (PAR) polymer film modified glassy carbon electrode (GCE). The PAR polymer film modified electrode shows excellent electrocatalytic activity toward the oxidation of DA in a phosphate buffer solution (PBS) (pH 4.0). The linear range of 5.0×10?6–3.0×10?5 M and detection limit of 2.0×10?7 M were observed. Simultaneous detection of AA, DA and UA has also been demonstrated on the modified electrode. This work provides a simple and easy approach to selective detection of DA in the presence of AA and UA.  相似文献   

6.
The electrochemical behavior of SiCu W11 heteropolyacide in acidic aqueous solution was studied. The effect of solution pH on the electrochemical behavior of SiCu W11 was discussed and the mechanism was suggested. New electrode was modified by muhilayer films composed of heteropolyanion (SiCu W11 and cationic polymer poly (diallyldimethylammonium chloride). Cyclic vohammetry showed the uniform growth of the film. The modified electrodes exhibited some special electrochemical properties in the films, different from those in homogeneous aqueous solutions. The effect of pH on the redox behavior of SiCu W11 in the films was discussed in details. The muhilayer film electrodes have an excellent electrocatalytic response to the reduction of BrO3^- and NO2^-.  相似文献   

7.
于浩  郑建斌 《中国化学》2007,25(4):503-509
A copper hexacyanoferrate modified ceramic carbon electrode (CuHCF/CCE) had been prepared by two-step sol-gel technique and characterized using electrochemical methods. The resulting modified electrode showed a pair of well-defined surface waves in the potential range of 0.40 to 1.0 V with the formal potential of 0.682 V (vs. SCE) in 0.050 mol·dm^-3 HOAc-NaOAc buffer containing 0.30 mol·dm^-3 KCl. The charge transfer coefficient (a) and charge transfer rate constant (ks) for the modified electrode were calculated. The electrocatalytic activity of this modified electrode to hydrazine was also investigated, and chronoamperometry was exploited to conveniently determine the diffusion coefficient (D) of hydrazine in solution and the catalytic rate constant (kcat). Finally, hydrazine was determined with amperometry using the resulting modified electrode. The calibration plot for hydrazine determination was linear in 3.0 × 10^-6--7.5 × 10^-4 mol·dm^-3 with the detection limit of 8.0 × 10^-7 molodm^-3. This modified electrode had some advantages over the modified film electrodes constructed by the conventional methods, such as renewable surface, good long-term stability, excellent catalytic activity and short response time to hydrazine.  相似文献   

8.
A robust and effective composite film combined the benefits of Nafion, room temperature ionic liquid (RTIL) and multi‐wall carbon nanotubes (MWNTs) was prepared. Hemoglobin (Hb) was successfully immobilized on glassy carbon electrode surface by entrapping in the composite film. Direct electrochemistry and electrocatalysis of immobilized Hb were investigated in detail. A pair of well‐defined and quasi‐reversible redox peaks of Hb was obtained in 0.10 mol·L?1 pH 7.0 phosphate buffer solution (PBS), indicating that the Nafion‐RTIL‐MWNTs film showed an obvious promotion for the direct electron transfer between Hb and the underlying electrode. The immobilized Hb exhibited an excellent electrocatalytic activity towards the reduction of H2O2. The catalysis current was linear to H2O2 concentration in the range of 2.0×10?6 to 2.5×10?4 mol·L?1, with a detection limit of 8.0×10?7 mol·L?1 (S/N=3). The apparent Michaelis‐Menten constant (Kmapp) was calculated to be 0.34 mmol·L?1. Moreover, the modified electrode displayed a good stability and reproducibility. Based on the composite film, a third‐generation reagentless biosensor could be constructed for the determination of H2O2.  相似文献   

9.
An electrochemiluminescence (ECL) sensor based on Ru(bpy)32+-graphene-Nafion composite film was developed. The graphene sheet was produced by chemical conversion of graphite, and was characterized by atomic force microscopy (AFM), scanning electron microscopy (SEM), and Raman spectroscopy. The introduction of conductive graphene into Nafion not only greatly facilitates the electron transfer of Ru(bpy)32+, but also dramatically improves the long-term stability of the sensor by inhibiting the migration of Ru(bpy)32+ into the electrochemically inactive hydrophobic region of Nafion. The ECL sensor gives a good linear range over 1 × 10−7 to 1 × 10−4 M with a detection limit of 50 nM towards the determination of tripropylamine (TPA), comparable to that obtained by Nafion-CNT. The ECL sensor keeps over 80% and 85% activity towards 0.1 mM TPA after being stored in air and in 0.1 M pH 7.5 phosphate buffer solution (PBS) for a month, respectively. The long-term stability of the modified electrode is better than electrodes modified with Nafion, Nafion-silica, Nafion-titania, or sol-gel films containing Ru(bpy)32+. Furthermore, the ECL sensor was successfully applied to the selective and sensitive determination of oxalate in urine samples.  相似文献   

10.
朱小红  林祥钦 《中国化学》2009,27(6):1103-1109
用循环伏安法(CV)选择不同电位区间来电聚合烟酰胺(NA)得到了两种聚合物膜修饰电极:poly-niacinamide/GCE (poly-NA/GCE)和poly- nicotinic acid /GCE (poly-NC/GCE)。这两电极都具有显著电化学催化作用,能明显地降低多巴胺(DA)、尿酸(UA)和抗坏血酸(AA)的氧化过电位,并在混合溶液中使这些物质的氧化峰电位距离足够大,可进行三物质的同时测定。poly-NC/GCE的电催化性能更好一些,用差分脉冲伏安法(DPV)测定抗坏血酸,线性范围为75–3000 µmol L-1,电流灵敏度为5.6 mA•L•mol-1;测定多巴胺,线性范围为0.37 – 16 µmol L-1,电流灵敏度为1140 mA•L•mol-1; 测定尿酸,线性范围为0.74 – 230 µmol L-1,电流灵敏度为102 mA•L•mol-1。该电极具有很高的灵敏度、选择性和抗污染能力。  相似文献   

11.
《Analytical letters》2012,45(4):705-714
Abstract

La(OH)3 nanoparticles were successfully prepared with the sol‐gel method, and the preparation of a glassy carbon electrode modified by La(OH)3 nanoparticles was investigated. The modified electrode shows an excellent electrocatalytic activity for hydroquinone. The anodic and cathodic overpotentials are reduced by ca. 143 mV and 83 mV, respectively, compared with those obtained with a bare glassy carbon electrode. According to the electrochemistry response, we set up a new method to determinate hydroquinone. The catalytic anodic current response of differential pulse voltammogram increases linearly with hydroquinone concentrations from 2.7×10?7 to 6.5×10?4 mol L?1 with a detection limit of 6.0×10?8 mol L?1. The recovery of hydroquinone in a simulative sample is satisfactory, especially for its elimination of the interference of 1,2‐benzenediol (pyrocatechol) and 1,3‐benzenediol (m‐dihydroxybenzene). The method is simple, quick, and sensitive.  相似文献   

12.
《Analytical letters》2012,45(13):2077-2088
Abstract

An electrochemiluminescence (ECL) method for reduced nicotinamide adenine dinucleotide (NADH) was proposed by immobilizing tris(2,2′‐bipyridyl) ruthenium(II) (Ru(bpy)3 2+) in multiwall carbon nanotubes (MWCNTs)/Nafion composite membrane that was formed on glassy carbon electrode surface. The electrochemical and ECL behaviors of the immobilized Ru(bpy)3 2+ were investigated. The cyclic votammogram of the modified electrode in pH 7.0 phosphate buffer solution showed a couple of redox peaks at +1190 and +1060 mV at 100 mV/s. The composite film had a more open structure and a large surface area allowing faster diffusion of Ru(bpy)3 2+. The presence of MWCNTs resulted in the improved ECL sensitivity and longer‐term stability of the modified electrode. The modified electrode showed a linear response to NADH in the concentration range of 1.0×10?6 to 1.6×10?5 M with a detection limit of 8.2×10?7 M.  相似文献   

13.
A novel route for the fabrication of neodymium hexacyanoferrate (NdHCF) modified glassy carbon electrodes (GCE) was proposed. The morphological characterization of NdHCF was examined by scanning electron microscopy (SEM) and Fourier transform infrared spectra (FTIR). The performances of the NdHCF/GCE were characterized with cyclic voltammetry and differential pulse voltammograms (DPV). The modified electrode showed excellent electrocatalytic effect and high stability toward the electrochemical oxidation of dopamine (DA) in phosphate buffer solution (pH 5.5) with a diminution of the anodic overpotential of 155 mV. The anodic peak currents increased linearly with the concentration of DA from 5.0×10?7 to 6.0×10?4 M with a detection limit of 1.0×10?8 M (S/N=3). The most important is that the modified electrode could be used for the determination of DA in the presence of an ascorbic acid concentration as large as 100‐fold that of DA. The proposed method was used to determine DA in DA‐hydrochloride injection and showed excellent sensitivity and recovery. The ease of fabrication, high stability, and low cost of the modified electrode are the promising features of the proposed sensor.  相似文献   

14.
In this work, a simple and effective approach to obtain stable, nontoxic and strong electrochemiluminescence (ECL) interfaces is provided by coating TiO2 nanoparticles (NPs) modified glassy carbon electrode (GCE) surfaces with Nafion. Unlike a decrease of the current resulting from the blocked diffusion usually displayed in electrochemical processes by Nafion coating, a Nafion/TiO2 NPs modified electrode not only shows a highly stable ECL, but also shows an 8‐fold increase of ECL intensity and a reduction of the overpotential of ca. 300 mV in the presence of K2S2O8 as co‐reactant, compared with those of bare TiO2 NPs modified electrodes. The roles of Nafion coating on TiO2 NPs in the ECL process are proposed to be twofold: to provide refuge for the free radicals and to enhance the electron‐hole recombination. Benefiting from its excellent ECL performance, the cationic exchange function of Nafion and the susceptible to being oxidized performance of dopamine (DA) by holes, the Nafion/TiO2 composite electrode could be used to sensitively and selectively detect DA with a detection limit of 1.0×10?11 M and a linear range of 1.0×10?11–6.0×10?7 M. The coexisting anionic species such as excess ascorbic acid show little interference on DA detection.  相似文献   

15.
A sensitive and selective electrochemical method for the determination of dopamine (DA) was developed using a calix[4]arene crown‐4 ether (CACE) film modified glassy carbon electrode (GCE).The modified electrode exhibited good electrocatalytic activity for electrochemical oxidation of DA in the pH 6.00 Britton–Robinson buffer solution, and ascorbic acid (AA) did not interfere with it. The diffusion coefficient (D=2.7×10?5 cm2 s?1), and the kinetic parameter such as the electron transfer coefficient (α=0.54) of DA at the surface of CACE were determined using electrochemical approaches. The catalytic oxidation peak currents showed a linear dependence on the DA concentration and a linear analytical curve was obtained in the range of 2.0×10?5–1.0×10?3 M of DA with a correlation coefficient of 0.9990. The detection limit (S/N=3) was estimated to be 3.4×10?6 M. This method was also examined for the determination of DA in an injection sample. In addition, effects of possible interferences were investigated. The present work shows the potential of the proposed method for the fabrication of a modified electrode, as it can be effectively used for voltammetric detection of DA.  相似文献   

16.
《Electroanalysis》2005,17(7):607-612
Based on the inhibition effect of dopamine and epinephrine on Ru(bpy) ‐tripropylamine electrogenerated chemiluminescence system, the excellent properties of carbon nanotube, and the cation permselectivity of Nafion film, an electrogenerated chemiluminescence inhibition method for determination of dopamine and epinephrine in the presence of ascorbic acid at carbon nanotube/Nafion‐Ru(bpy) composite film modified glassy carbon electrode was described. The results showed that the proposed method was sensitive and selective for the determination of dopamine and epinephine. The linear calibration range was from 1.6×10?9 M to 3.2×10?5 M and 5×10?8 M to 6×10?5 M for dopamine and epinephrine, respectively. 200‐fold excess of ascorbic acid did not interfere with the determination of 1 μM dopamine and epinephrine.  相似文献   

17.
《Electroanalysis》2006,18(3):282-290
Metallophthalocyanine (MPc) and its derivatives are well known as electrocatalysts to catalyze oxidation or reduction of some species, such as cysteine, nitric oxide. Their nanosized particles may display the potential optics, electronic, catalytic and structural properties. In this paper, carbon paste electrodes modified with nanosized cobalt phthalocyanine particles (denoted as Nano‐CoPc‐CPE) are fabricated. The electrocatalytic oxidation of dopamine (DA) and ascorbic acid (AA) on the Nano‐CoPc‐CPE was investigated by means of cyclic voltammetry. Nano‐CoPc particles perform good electrocatalytic activity to DA and AA. The anodic peak potentials of DA and AA were separated with good sensitivity in the presence of cetyltrimethylammonium bromide (CTAB). The DA and AA can be simultaneously determined by using differential pulse voltammetry. On optimal conditions, the good linear response to DA and AA was observed in the range of 3.0×10?6–1.0×10?4 M and 5.0×10?6–3.0×10?4 M with the correlation coefficient of 0.9983 and 0.9978, respectively. Moreover, 100‐fold AA did not interfere in the determination of DA. This method has been used to simultaneously determine DA and AA concentration in mixed drug samples with satisfactory results.  相似文献   

18.
《Analytical letters》2012,45(15):2819-2831
Abstract

A new hemoglobin (Hb) modified carbon paste (CP) electrode was fabricated by simply mixing the hemoglobin with carbon powder and paraffin homogeneously. To prevent the leakage of Hb from the electrode surface, a Nafion film was further applied on the surface of Hb-carbon composite paste electrode. Direct electrochemistry of hemoglobin in the paste electrode was easily achieved, and a pair of well-defined quasi-reversible redox peak of heme Fe(III)/Fe(II) couple appeared with the formal potential (E0′) as ?0.335 V (vs. Saturated calomel electrode; CE) in pH 7.0 phosphate buffer solution (PBS). The fabricated Hb modified electrode showed good electrocatalytic ability to the reduction of trichloroacetic acid (TCA) and H2O2.  相似文献   

19.
《Electroanalysis》2004,16(17):1413-1418
The in‐site functionalization of 4‐aminothiophenol (4‐ATP) self‐assembled monolayer on gold electrode at physiological pH yields a redox active monolayer of 4′‐mercapto‐N‐phenylquinone diimine (MNPD). The functionalized electrode exhibits excellent electrocatalytic responses towards dopamine (DA) and ascorbic acid (AA), reducing the overpotentials by about 0.22 V and 0.34 V, respectively, with greatly enhanced current responses. Due to its different catalytic activities toward DA and AA, the modified electrode resolves the overlapping voltammetric responses of DA and AA into two well‐defined voltammetric peaks by differential pulse voltammetry (DPV), which can be used for the simultaneous determination of these species in a mixture. The catalytic peak current obtained from DPV was linearly related to DA and AA concentration in the ranges of 5.0×10?6?1.25×10?4 M and 8.0×10?6?1.3×10?4 M with correlation coefficient of 0.999 and 0.998, respectively. The detective limits (3σ) for DA and AA were found to be 1.2×10?6 M and 2.4×10?6 M, respectively. The modified electrode shows good sensitivity, selectivity and stability, and has been applied to the determination of DA and AA simultaneously in samples with satisfactory results.  相似文献   

20.
Poly(4-vinylpyridine) (PVP)-based anion exchange polymers are not studied as much as cation exchange polymers Nafion and Eastman Kodak AQ for electroanalytical applications. Similarly, octacyanomolybdate [Mo(CN)8 4−] has not been studied much as a redox mediator. This communication presents results from examinations of the behaviour of Mo(CN)8 4−-doped PVP ionomer film electrode to highlight the opportunities for realization of the application of this composite electrode for l-ascorbic acid (AH2) estimation via electrocatalytic mediation in acidic medium. The modified electrodes were characterized by cyclic voltammetry and rotating disc electrode voltammetry. PVP coatings possess strong anion-binding capacity for Mo(CN)8 4− mediator with an extraction coefficient of 990, and electrostatically cross-linked PVP films offer insignificant resistance to permeation of AH2, facilitating a cross-exchange reaction between the substrate and the mediator in the entire film volume. They show effective electrocatalytic oxidation of AH2, with the oxidation potential of AH2 decreased by ∼200 mV in overpotential compared to that at bare electrode. Mo(CN)8 4−/PVP composite electrode does not respond to the more common interferents of l-ascorbic acid estimation even at high positive potentials. These and several other attractive potentialities of the modified electrode are demonstrated by direct determination of AH2 in a commercial vitamin C tablet without any special treatment, with the value closely agreeing (±0.75%) with the reference method.  相似文献   