1.
《Analytical letters》2012,45(4):737-746
Abstract

A rapid, sensitive, and selective high‐performance liquid chromatography‐tandem mass spectrometric method (HPLC‐MS‐MS) for the determination of coumatetralyl in human serum using warfarin as an internal standard has been developed and validated. Coumatetralyl and the internal standard were extracted from the human serum samples by liquid‐liquid extraction with ethyl acetate, followed by separation on a XDB C18 reversed‐phase column (150 mm×2.1 mm i.d., 5 µm) using a mobile phase consisting of acetic acid‐ammonium acetate (5 mmol/L, pH=4.5)/methanol (20:80, v/v) at a constant flow rate of 0.40 mL/min. Coumatetralyl and the internal standard were ionized by negative ion pneumatically assisted electrospray and detected in the multiple‐reaction monitoring mode using precursor→product ion combinations at m/z 291→247 and 307→161, respectively. The calibration curve was linear (r2=0.9945) in the concentration range of 0.5~100.0 ng/mL, with a lower limit of quantification of 0.5 ng/mL in human serum. Intra‐ and inter‐day relative standard deviations were less than 6.3 and 11.0%, respectively. The mean extraction recovery was 87.9% for coumatetralyl and 90.1% for the internal standard. This method is found to be able to determine trace coumatetralyl in human serum and can be used for the diagnosis of poisoned human beings.  相似文献   

2.
Electrospray ionization mass spectrometry (ESI-MS) is a powerful method for sequencing peptides. A novel fragmentation pattern with the loss of a neutral fragment of 45 Da was observed with the dipeptides, tripeptides,tetrapeptides and pentapeptides containing phenylalanine or histidine residues. A novel rearrangement reaction with the extrusion of a formamide piece was studied and the rearrangement mechanism was proposed and confirmed by deuterium labeling experiments with ESI-MS^n and high-resolution mass spectrometry. These findings are potentially helpful in identifying the specific sequence pattern in the peptide sequencing.  相似文献   

3.
An electrospray ionization / tandem mass spectrometric (ESUMS/MS) method was developed for the simultaneous identification and analysis of three aconitine alkaloids [mesacontine (MA), hypaconitine (HA), and aconitine (A)] as intact molecules at low nanogram level in Chinese traditional medicine Chuanwu decoction as well as in human whole blood extract without chromatographic separation.  相似文献   

4.
《Analytical letters》2012,45(14):2317-2331
The genus Stellaria (Caryophyllaceae) presents widely distributed plants often used in traditional medicine. Flavonoids are highly active plant secondary metabolites that may be involved in some of the effects of Stellaria plants. In this study, two new high-performance liquid chromatography–electrospray ionization tandem mass spectrometry (HPLC–ESI-MS-MS) methods were developed for the determination of flavonoids and isoflavonoids in plant material. The separations were performed on a reverse-phase C18 column with gradient elution using methanol and water with 0.5% acetic acid as the mobile phase. Multiple reaction monitoring was used for the tandem mass spectrometry detection and the two most intensive transitions were chosen for the identification of each analyte. The limits of detection and the limits of quantification were between 0.2 and 15.0 ng/mL and 0.6 and 50.0 ng/mL. The developed methods were successfully used for the analyses of four representatives of the genus Stellaria. All the studied herbs contained luteolin and its 7-O-glycosides, naringenin, kaempferol, quercetin, its glycoside rutin, apigenin, and its 7-O-glycoside. One coumarin, scopoletin, was also found. Isoflavones were primarily represented by genistein, genistin, and ononin. Some of the analytes were detected for the first time in Stellaria sp. The findings support that these methods are suitable for analyses of plant material.  相似文献   

5.
《Analytical letters》2012,45(11):1862-1873
High performance liquid chromatography coupled with electrospray ionization quadrupole-time-of-flight tandem mass spectrometry was used to profile the phenylethanoid glycosides in Lagotis brevituba. A total of twenty-three phenylethanoid glycosides were characterized by comparing the retention time and fragmentation with standards, accurate mass measurements, and fragmentation at low and high collision energies. Most phenylethanoid glycosides were reported in L. brevituba for the first time. This established method may be employed for comprehensive quality control of L. brevituba.  相似文献   

6.
Mass spectroscopic characteristics of phosphoryl amino acids were studied in detail by positive and negative electrospray ionization mass spectrometry (ESI-MS) in conjunction with tandem mass spectrometry (MS/MS). Besides N-diisopropyloxyphosphoryl amino acids (N-DIPP-AA), O-phospho- and O-diisopropyloxyphosphoryl amino acids (O-DIPP-AA) were studied and compared to N-DIPP-AA. The fragmentation pathways of [M H]^ ,[M Na]^ and [M-H]^- ions of phosphoryl amino acids were summarized. In addition to several similar patterns, each of them showed its characteristic fragmention.  相似文献   

7.
A rapid, easy, and reliable method was developed for the characterization of jet fuel with minimal sample preparation. A standard solution of 13 aliphatic n-alkanes in hexane was used to evaluate and validate the separation using cold-electron ionization gas chromatography–mass spectrometry. The method was evaluated and validated by the linearity, accuracy, and precision for all analytes. The limits of detection and quantification for each n-alkane were also evaluated. Nine major n-alkanes from n-octane to n-hexadecane were positively identified and quantified in jet fuel due to the enhanced molecular ion in the mass spectra. Major n-alkanes and their corresponding isomers in jet fuel were also identified from the extracted ion chromatograms. n-Undecane, n-dodecane, n-tridecane, and n-tetradecane were present at the highest concentrations in jet fuel at approximately 7% (v/v). The total concentrations of total straight chain alkanes were 34–37% in jet fuel that was comparable with the standard value of 32%.  相似文献   

8.
A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric method (LC-MS-MS) for the determination of eupatilin in human plasma has been developed. Eupatilin and an internal standard; (S)-N-(3-{3-fluoro-4-[6-(1-methyl-1H-tetrazol-5-yl)-pyridine-3-yl]-phenyl}-2-oxo-oxazolidin-5-ylmethyl)-acetamide (DA-7867) were extracted from human plasma by liquid-liquid extractionand analyzed on a phenyl-hexyl column using the mobile phase: acetonitrile-ammonium formate (10 mM, pH 3.0) (60:40, /). Analytes were detected using electrospray ionization-tandem mass spectrometry in multiple-reaction monitoring mode. The calibration curve was linear (r = 0.999) over the concentration range: 1.00–500 ng mL–1 with a lower limit of quantification of 1.0 ng mL–1 using a 100 L plasma sample. The precision (CV%) of this assay ranged: 2.4–7.0%, relative error: –7.0 to +2.0%. Recoveries of eupatilin ranged: 64.3–65.0%, with that of DA-7867 (internal standard) being 87.0 ± 5.3%.  相似文献   

9.
An ultrahigh-performance liquid chromatography–tandem mass spectrometry method was developed and validated for the simultaneous determination of sterigmatocystin, verruculogen, enniatin A, fusarenon-X, fumonisins B1, B2, B3, aflatoxins B1, B2, G1, G2, ochratoxin A, deoxynivalenol, 3-acetyldeoxynivalenol, 5-acetyldeoxynivalenol, and zearalenone. The mycotoxins were extracted and cleaned up using a multitoxin column, separated on a C18 column, and then detected on a triple-quadrupole mass spectrometer. The limits of detection and quantification ranged within 0.2–2?µg/kg and 1–10?µg/kg, respectively. The recoveries ranged from 70.8 to 118.4%, with relative standard deviations below 15%. The method was used to analyze 80 samples obtained from Shandong Province in China. Fifty-eight samples were contaminated with 10 mycotoxins at concentrations ranging from 1.4 to 6566.1?µg/kg. Some samples exceeded the maximum limits in China and in European regulations for mycotoxins in unprocessed maize.  相似文献   

10.
《Analytical letters》2012,45(13):1979-1987
Liquid chromatography with tandem mass spectrometry was used for the determination of nitrofurantoin, nitrofurazone, furazolidone, and furaltadone in chicken feed. The nitrofurans were extracted with phosphate buffer (pH 7) and sodium chloride. Proteins and lipids were removed with acetonitrile and hexane before purification with ethyl acetate, dilution in 1:1 acetonitrile-5 millimolar ammonium acetate at pH 7.3, and filtration prior to analysis. The limits of detection were 1.69, 1.74, 2.01, and 1.45 microgram per kilogram for nitrofurantoin, nitrofurazone, furazolidone, and furaltadone, respectively. The mean recoveries were between 84.6 and 110.6 percent. The method was employed to determine nitrofurans in chicken feed.  相似文献   

11.
High-performance liquid chromatography coupled with high-resolution mass spectrometry was used for the determination of polyphenols in Lycium barbarum leaves. Twenty compounds extracted by methanol–water were tentatively identified that included chlorogenic acids, flavonoids, and phenolic acids. Neochlorogenic acid, chlorogenic acid, cryptochlorogenic acid, isochlorogenic acid B, isochlorogenic acid A, and isochlorogenic acid C were identified in Chinese cultivated L. barbarum leaves for the first time. Caffeic acid and isoquercitrin were also present. The concentrations of these compounds in L. barbarum leaves were determined. The results showed that all analytes had linear calibration relationships with limits of detection from 0.318 to 3.35?ng mL?1. The polyphenols and flavonoids in L. barbarum leaves provided strong 2,2-diphenyl-1-picrylhydrazyl radical-scavenging capacity (IC50 of 23.1?±?0.4 to 26.0?±?0.4?µg mL?1). This method is suitable for the determination of polyphenols in L. barbarum leaves, which provide polyphenols with suitable antioxidant activity.  相似文献   

12.
《Analytical letters》2012,45(10):1634-1649
A selective method for the determination of fourteen nitroimidazoles and their hydroxy-metabolites in honey was developed based on improved molecularly imprinted solid-phase extraction followed by liquid chromatography–tandem mass spectrometry. The separation of analytes was performed on a C18 column using a mobile phase of 0.1% formic acid in acetonitrile and 0.1% formic acid in water with gradient elution. The method was suitable for metronidazole, hydroxymetronidazole, dimetridazole, ronidazole, hydroxydimetridazole, ipronidazole, hydroxyipronidazole, carnidazole, menidazole, nimorazole, ornidazole, secnidazole, ternidazole, and tinidazole. The procedure was evaluated according to EU Commission Decision 2002/657/EC requirements by determining linearity, specificity, recovery, repeatability, within-laboratory reproducibility, decision limit, detection capability, matrix effects, and stability. The method determined nitroimidazoles and their hydroxy-metabolites below the recommended concentration level of 3 µg kg?1. The decision limits and detection capabilities ranged from 0.110 µg kg?1 to 0.387 µg kg?1 and from 0.179 µg kg?1 to 0.508 µg kg?1, respectively. The results from stability tests indicated that all analyzed nitroimidazoles were stable in honey stored at 4°C for at least 28 weeks and that elevated temperature and exposure to light exposure accelerated their degradation. The method was successfully applied to the analysis of a wide variety of honey samples.  相似文献   

13.
14.
《Analytical letters》2012,45(6):934-943
Infant formula provides a good source of fructooligosaccharides, which are considered to be functional ingredients of food due to their positive effects on gastrointestinal function. This study presents a simple and specific ultra-high performance liquid chromatography–tandem mass spectrometry method for the ultrasensitive determination of three fructooligosaccharides in infant formula. The analytes were extracted using acetonitrile-water solutions. The compounds were separated with an amide column by gradient elution using acetonitrile and water as mobile phases. The identification and quantification were achieved by using electrospray ionization tandem mass spectrometry in negative ion mode with multiple reaction monitoring. Accuracy, precision, limits of quantification, and limits of detection of the method were obtained. Under the optimal conditions, all calibration curves for fructooligosaccharides targets showed good linearity (R2 ≥ 0.998). The limits of detection and quantification were below 0.82 and 2.74 ng mL?1, respectively. The recoveries of the method ranged from 98.5% to 104.4%. To the knowledge of the authors, this is the first quantitative determination of fructooligosaccharides in infant formula by ultra-high performance liquid chromatography–tandem mass spectrometry. The method may be suitable for the determination of trace concentrations of fructooligosaccharides in other food.  相似文献   

15.
《Analytical letters》2012,45(14):2307-2316
A facile method based on liquid chromatography coupled with triple quadrupole mass spectrometry was established to determine floridoside and isofloridoside in red algae. Correlation coefficients of the calibration curves were larger than 0.9989, indicated good linearity. Detection limits of floridoside and isofloridoside were 0.05 and 0.20 ng/mL, respectively, and the limits of quantification were 0.1 and 0.4 ng/mL. The recoveries varied from 75.7% to 76.8%, and relative standard deviations of inter-day and intra-day precision were lower than 8.5% (n = 5). The effects of sea level variations in the intertidal zone on the osmotic role of floridoside and isofloridoside concentrations in seven red algae were investigated. It was shown that algae that inhabit higher levels in the intertidal zone contained higher concentrations of floridoside and isofloridoside. The results suggest that the presence of direct sun, exposure time, and temperature influenced to the concentrations of floridoside and isofloridoside due to the osmotic pressure adjustments.  相似文献   

16.
Using high-performance liquid chromatography combined with tandem mass spectrometric detection, an approach has been developed for the determination of the most stable nerve agent biomarker, methylphosphonic acid, in human blood plasma. The proposed method is based on the derivatization of methylphosphonic acid with p-bromophenacyl bromide. The optimization of conditions for human plasma sample preparation, mass spectrometric detection conditions, and gradient elution program has been performed. The proposed approach has demonstrated satisfactory reproducibility and selectivity of the determination; the limit of detection for methylphosphonic acid in human plasma was 3 ng mL–1.  相似文献   

17.
《Analytical letters》2012,45(17):3208-3218
Abstract

A method for the detection of microcystins (microcystin LR, RR, and YR) in cyanobacteria by supercritical fluid extraction (SFE) and liquid chromatography‐mass spectrometry (LC/MS) has been developed. Supercritical fluids for the analytical extraction of nonvolatile, higher molecular weight compound, and microcystins from cyanobacteria were investigated. The microcystins included in this study are sparsely soluble in neat supercritical fluid CO2. However, the microcystins was successfully extracted with a ternary mixture (90% CO2, 9.5% methanol, 0.5% water) at 40°C and 250 atm. The polar carbon dioxide‐aqueous methanol fluid system gave high extraction efficiency for the extraction of the polar microcystins from cyanobacteria. The microcystins were determined by liquid chromatography‐tandem mass spectrometry (LC/MS/MS).  相似文献   

18.
An analytical method was established to simultaneously quantify flonicamid and its metabolites 4-trifluoromethylnicotinic acid (TFNA), N-(4-trifluoromethylnicotinoyl) glycine (TFNG), and 4-trifluoromethylnicotinamide (TFNA-AM) in tea using orthogonal experimental design and liquid chromatography–tandem mass spectrometry (LC–MS/MS). Residues were extracted from the samples with acetonitrile containing 1% acetic acid and were purified with graphitized carbon black. The linearity of the method was excellent in the concentration range of 0.01–10?µg/mL, producing correlation coefficients greater than 0.996 for the target compounds. The limits of detection and quantification of all analytes in tea were 0.0013–0.013?mg/kg and 0.004–0.040?mg/kg, respectively. The average recoveries of flonicamid, TFNA, TFNG, and TFNA-AM ranged from 75.14 to 92.72%, with intra- and interday relative standard deviations of 1.07–9.75%. The proposed method was successfully applied to the terminal residue determination of flonicamid and its metabolites in dry tea processed from three field trials’ fresh samples. The determined total terminal residue concentrations of flonicamid 10?days after the last application at all three sites were below the maximum residue limit (MRL) set by the European Union (0.1?mg/kg) and the residues in all samples were lower than the MRL established by the United States Environmental Protection Agency (EPA) (8?mg/kg). This method may be used to meet the requirements for the determination of flonicamid and its metabolites that could provide guidance for establishing a MRL for flonicamid in tea in China.  相似文献   

19.
The illicit use of β-blockers in food-producing animals may induce the presence of these compounds in meat and milk. The presence of β-blockers in these foods is a safety issue. A simple and economic high-performance liquid chromatography – tandem mass spectrometry method was developed and validated for β-blockers in bovine and porcine muscle, kidney, liver, and bovine milk. The focus of the study was on the detection and quantitation of acebutolol, atenolol, betaxolol, carazolol, metoprolol, nadolol, penbutolol, and propranolol. Homogenized tissues were digested with glucuronidase/aryl sulfatase to release the analytes that were extracted with acetonitrile and purified using matrix solid-phase dispersion. For residues in milk, acidolysis and extraction utilized trichloroacetic acid and acetonitrile and the samples were purified using mixed-mode cation exchange solid phase extraction. Standard curves generated using homogenized tissues and milk matrices were linear with correlation coefficients exceeding 0.99. The limits of detection and quantification were 1?μg/kg and 2.5?μg/kg, respectively, for all analytes in the meat tissues. The corresponding values for milk were 0.2?μg/kg and 0.5?μg/kg. The average recoveries of the spiked samples were from 84.4 to 114.2% with the standard deviations of the intra- and inter-day assays from 2.0 to 14.6% and 2.9 to 18.7%, respectively. This method is simple, economical, and time-saving for the determination of β-blockers in bovine tissue, porcine tissue, and bovine milk.  相似文献   

20.
A simple, rapid, and selective method to determine the concentration of mildronate in human plasma and urine using ultra performance liquid chromatography?Ctandem mass spectrometry (UPLC-MS-MS) was developed and validated. The detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reaction monitoring mode via electrospray ionization at m/z 147.2?C58.0 for mildronate and m/z 147.2?C87.8 for the internal standard, carbachol. The UPLC separation was carried out with a UPLC BEH HILIC column. The mobile phase consisted of 0.08% formic acid in 30 mM ammonium acetate solution and acetonitrile (23:77, v/v). Plasma samples were extracted from plasma by protein precipitation and urine samples were diluted with the mobile phase. The analysis time was 3.5 min for each sample. Linear calibration curves ranged from 0.10 to 100.00 ??g mL?1 in human plasma and 0.50 to 600.00 ??g mL?1 in urine. The method had been successfully applied to a pharmacokinetic study in healthy volunteers. After single intravenously administration of 250, 500, and 750 mg mildronate, the elimination half-life (t 1/2) were (2.74 ± 0.67), (4.86 ± 0.82) and (5.16 ± 0.77) h, respectively. The t 1/2 for the 250 mg dose did vary significantly with other dosages (P < 0.05), mildronate may have non-linear pharmacokinetics in humans.  相似文献   