首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
One of the major problems in amperometric biosensors based on detection of H2O2 produced by enzymatic reaction between oxidase enzymes and substrate is the interference of redox active compounds such as ascorbic acid (AA), dopamine (DA) and uric acid (UA). To minimize these interferences, sodium bismuthate was used for the first time as an insoluble pre‐oxidant in the flow injection (FI) amperometric glucose biosensor at a Glucose oxidase (GOx) immobilized Pt/Pd bimetallic modified pre‐anodized pencil graphite electrode (p.PGE). In this context, these interfering compounds were injected into a flow injection analysis (FIA) system using an injector which was filled with NaBiO3. Thus, these interferents were converted into their redox inactive oxidized forms before reaching the electrode in the flow cell. While glucose was not influenced by the pre‐oxidant in the injector, the huge oxidation peak currents of the interferents decreased significantly in the biosensor. FI amperometric current time curves showed that the AA, DA and UA were minimized by 96 %, 86 %, and 98 % respectively, in the presence of an equivalent concentration of interferences in a 1.0 mM glucose solution. The proposed FI amperometric glucose biosensor exhibits a wide linear range (0.01–10 mM, R2=0.9994) with a detection limit of 2.4×10?3 mM. Glucose levels in the artificial serum and two real samples were successfully determined using the fabricated FI amperometric biosensor.  相似文献   

2.
The adsorption of methylene blue (MB) onto zirconium phosphate (ZrP) was studied and the adsorption capacity value and isotherms were determined. The adsorption capacity of ZrP was increased after being exposed to gas phase n-butyl amine. The adsorbed MB on ZrP was used as a modifier material in carbon paste electrode (MCPE), which in turn was used in voltammetric investigations and flow injection (FI) amperometric determination of ascorbic acid (AA). A quasi-reversible electrode reaction of adsorbed MB was exhibited. A home made flow-through electrochemical cell with a suitable transparent window for irradiation of the electrode surface was constructed and used for amperometric FI studies. The photoamperometric-FI conditions were optimised as 1.5 mL min−1 flow rate, a 25 cm transmission tubing length, a 100 μL injection volume, and a constant applied potential of +100 mV versus SCE. The calibration curve for AA was linear over the concentration range from 1.0 × 10−6 to 4.0 × 10−5 M. The relative standard deviation of four replicate injections of 3.0 × 10−5 M AA was 1.2%. The results obtained for AA determination in pharmaceutical products are in good agreement with those obtained using the procedure involving the reaction between triiodide and AA.  相似文献   

3.
《Analytical letters》2012,45(14):2671-2685
Abstract

A high performance liquid chromatography (HPLC) method with electrochemical detection (ED) was developed for the determination of benzidine, 3,3‐dimethylbenzidine, o‐toluidine and 3,3‐dichlorobenzidine in the wastewater of the textile industry. The aromatic amines were eluted on a reversed phase column Shimadzu Shimpack C18 using acetonitrile+ammonium acetate (1×10?4 mol L?1) at a ratio 46:54 v/v as mobile phase, pumped at a flow rate of 1.0 mL min?1. The electrochemical oxidation of the aromatic amines exhibits well‐defined peaks at a potential range of +0.45 to +0.78 V on a glassy carbon electrode. Optimum working potentials for amperometric detection were from 0.70 V to +1.0 V vs. Ag/AgCl. Analytical curves for all the aromatic amines studied using the best experimental conditions present linear relationship from 1×10?8 mol L?1 to 1.5×10?5 mol L?1, r=0.99965, n=15. Detection limits of 4.5 nM (benzidine), 1.94 nM (o‐toluidine), 7.69 nM (3,3‐dimethylbenzidine), and 5.15 nM (3,3‐dichlorobenzidine) were achieved, respectively. The detection limits were around 10 times lower than that verified for HPLC with ultra violet detection. The applicability of the method was demonstrated by the determination of benzidine in wastewater from the textile industry dealing with an azo dye processing plant.  相似文献   

4.
Cysteamine core polyamidoamine G-4 dendron branched with β-cyclodextrins was chemisorbed on the surface of Au electrodes and further coated with Pt nanoparticles. Adamantane-modified glucose oxidase was subsequently immobilized on the nanostructured electrode surface by supramolecular association. This enzyme electrode was used to construct a reagentless amperometric biosensor for glucose, making use of the electrochemical oxidation of H2O2 generated in the enzyme reaction. The amperometric response of the biosensor was rapid (6 s) and a linear function of glucose concentration between 5 and 705 μmol?L?1. The biosensor had a low detection limit of 2.0 μmol?L?1, sensitivity of 197 mA?mol?1?L?cm?2, and retained 94 % of its initial response after storage for nine days at 4 °C.  相似文献   

5.
《Electroanalysis》2004,16(19):1616-1621
The bismuth film electrode (BiFE) is presented for use in both batch voltammetric and flow injection (FI) amperometric detection of some nitrophenols (2‐nitrophenol, 2‐NP; 4‐nitrophenol, 4‐NP; 2,4‐dinitrophenol, 2,4‐DNP). The bismuth film was deposited ex situ (batch measurements) and in‐line (FI) onto a glassy carbon substrate electrode. Batch analysis of the nitrophenols was carried out in 0.04 M Britton Robinson (BR) buffer pH 4, while for FI measurements, a carrier/electrolyte solution composed of 0.1 M BR buffer pH 4 mixed with methanol (20+80, v/v%) was employed to resemble media used in preconcentration/clean‐up and flow separation sample pretreatment procedures. Under batch conditions, the voltammetric behavior of the nitrophenols was examined for dependence on medium pH in the range of 2 to 10. Employing the square‐wave voltammetry mode, the limits of detection were 0.4 μg L?1, 1.4 μg L?1, and 3.3 μg L?1 for 2‐NP, 4‐NP, and 2,4‐DNP, respectively. Under flow conditions, a simple in‐line electrochemical bismuth film renewal procedure was tested and shown to provide very good inter‐ and intra‐electrode reproducibility of the current signals at low μg L?1 analyte concentrations. The limits of detection for 2‐NP, 4‐NP and 2,4‐DNP obtained using FI and amperometric detection at ?1.0 V (vs. Ag/AgCl) were 0.3 μg L?1, 0.6 μg L?1 and 0.7 μg L?1, respectively, with linear ranges extending up to 20 μg L?1. The attractive performance of the BiFE under flow analysis conditions offers great promise with respect to its detection capability and to its use for a prolonged period of time with no need for inconvenient removal of the electrode from the system for mechanical surface treatment.  相似文献   

6.
Monolayers of 2-mercapto-5-methylbenzimidazole (MMB) were prepared on a polycrystalline gold electrode via a self-assembly process to produce a self-assembled monolayer. The resulting electrode was investigated by cyclic voltammetry and electrochemical impedance spectroscopy, and applied to the determination of chloramphenicol (CAP) in a pharmaceutical formulation using flow injection analysis along with amperometric detection. The amperometric cell was operated at ?0.75 V (vs Ag/AgCl) at a flow rate of 3 mL min?1. The method was applied to the determination of CAP in ophthalmic solutions, and its performance was compared to a previously validated HPLC method. The response to CAP is linear in the range from 0.050 to 1.000 µmol L?1 (r?=?0.9990), and the limit of detection is 44 µmol L?1.  相似文献   

7.
Layered nanocomposite of methylene blue (MB)-intercalated vanadium oxide was obtained through a simple hydrothermal synthesis method using MB, V2O5, and NaI as starting materials. The intercalation reaction was proven to be successful using X-ray diffraction pattern. The MB-V2O5 nanocomposite was characterized using a scanning electron micrograph, infrared spectra, thermogravimetric analysis, UV spectra, and electrochemical measurements. The intercalated MB cations showed a fine diffusion-controlled electrochemical redox process and facilitated the immobilized horseradish peroxidase’s (HRP) good catalytic reduction upon H2O2. The as-prepared MB-V2O5/HRP biosensor showed a linear response to H2O2 over a range from 2.0?×?10?6 to 9.5?×?10?5 M with a detection limit of 9.7?×?10?7 M (S/N ratio?=?3).  相似文献   

8.
王树青  陈峻  林祥钦 《中国化学》2004,22(4):360-364
IntroductionAmperometricbiosensorofhydrogenperoxideisofpracticalimportancebecauseofitswideapplicationsinchemical,biological,clinical,environmentalandmanyotherfields.Forimprovementofsensor抯quality,vari-ouskindsofchemicalmodificationmethodshavebeendevelopedforreducingredoxoverpotentialsofH2O2atelectrodesurfaces,increasingthedetectionsensitivity,linearrange,stabilityandlivetime.Ithasbeenshownthattheuseofsub-micrometersizedmetalparticlessuchasPt-blackcansignificantlyimprovethequalityofthebiosens…  相似文献   

9.
In this work, a sensitive electrochemical DNA biosensor for the detection of sequence‐specific target DNA was reported. Firstly, CuO nanospindles (CuO NS) were immobilized on the surface of a glassy carbon electrode (GCE). Subsequently, gold nanoparticles (Au NPs) were introduced to the surface of CuO NS by the electrochemical deposition mode. Probe DNA with SH (HS‐DNA) at the 5′‐phosphate end was covalently immobilized on the surface of the Au NPs through Au? S bond. Scanning electron microscopy (SEM) was used to elucidate the morphology of the assembled film, and electrochemical impedance spectroscopy technique (EIS) was used to investigate the DNA sensor assembly process. Hybridization detection of DNA was performed with differential pulse voltammetry (DPV) and the methylene blue (MB) was hybridization indicator. Under the optimal conditions, the decline of reduction peak current of MB (ΔI) was linear with the logarithm of the concentration of complementary DNA from 1.0×10?13 to 1.0×10?6 mol·L?1 with a detection limit of 3.5×10?14 mol·L?1 (S/N=3). In addition, this DNA biosensor has good selectivity, and even can distinguish single‐mismatched target DNA.  相似文献   

10.
《Analytical letters》2012,45(11):2285-2295
Abstract

Multi‐walled carbon nanotubes (MWNTs) were used as sorbent for flow injection (FI) on‐line microcolumn preconcentration coupled with flame atomic absorption spectrometry (FAAS) for determination of trace cadmium and copper in environmental and biological samples. Effective preconcentration of trace cadmium and copper was achieved in a pH range of 4.5–6.5 and 5.0–7.5, respectively. The retained cadmium and copper were efficiently eluted with 0.5 mol L?1 HCl for on‐line FAAS determination. The MWNTs packed microcolumn exhibited fairly fast kinetics for the adsorption of cadmium and copper, permitting the use of high sample flow rates up to at least 7.8 mL min?1 for the FI on‐line microcolumn preconcentration system without loss of the retention efficiency. With a preconcentration time of 60 sec at a sample loading flow rate of 4.3 mL min?1, the enhancement factor was 24 for cadmium and 25 for copper at a sample throughput of 45 h?1. The detection limits (3σ) were 0.30 and 0.11 µg L?1 for Cd and Cu, respectively. The precision (RSD) for 11 replicate measurements was 2.1% at the 10‐µg L?1 Cd level and 2.4% at the 10‐µg L?1 Cu level. The developed method was successfully applied to the determination of trace Cd and Cu in a variety of environmental and biological samples.  相似文献   

11.
A simple, selective and stable biosensor with the enzymatic reactor based on choline oxidase (ChOx) was developed and applied for the determination of choline (Ch) in flow injection analysis with amperometric detection. The enzyme ChOx was covalently immobilized with glutaraldehyde to mesoporous silica powder (SBA‐15) previously covered by NH2‐groups. This powder was found as an optimal filling of the reactor. The detection of Ch is based on amperometric monitoring of consumed oxygen during the enzymatic reaction, which is directly proportional to Ch concentration. Two arrangements of an electrolytic cell in FIA, namely wall‐jet cell with working silver solid amalgam electrode covered by mercury film and flow‐through cell with tubular detector of polished silver solid amalgam were compared. The experimental parameters affecting the sensitivity and stability of the biosensor (i. e. pH of the carrier solution, volume of reactor, amount of the immobilized enzyme, the detection potential, flow rate, etc.) were optimized. Under the optimized conditions, the limit of detection was found to be 9.0×10?6 mol L?1. The Michaelis‐Menten constant for covalently immobilized ChOx on SBA‐15 was calculated. The proposed amperometric biosensor with the developed ChOx‐based reactor exhibits good repeatability, reproducibility, long‐term stability, and reusability. Its efficiency has been confirmed by the successful application for the determination of Ch in two commercial pharmaceuticals.  相似文献   

12.
A stepwise strategy is reported for the design of a meditor-free amperometric tyrosinase biosensor. It is based on the azide-alkyne click reaction and carbodiimide coupling. Firstly, azide-terminated alkane thiols monolayers were self-assembled on the Au electrode surface. Then, nitrophenyl groups were covalent attached to the self-assembled monolayers (SAMs) via the click reaction of copper(I)-catalyzed 1,3-dipolar cycloadditions of azide-alkyne. Finally, the nitrophenyl group terminated SAMs were converted to aminophenyl-terminated interface by electrochemical reduction, and tyrosinase was covalent immobilized onto the Au electrode via carbodiimide reaction. Based on the stepwise strategy, a meditor-free amperometric tyrosinase biosensor was farbricated, and it showed good electrocatalytic reduction ability toward phenol, pyrocatechol and m-Cresol. Their linear ranges were over the range of 0.2 to 15.0 μmol·L?1, 0.2 to 73.0 μmol·L?1, and 0.2 to 33.0 μmol·L?1, respectively.  相似文献   

13.
A flow injection (FI) system with an amperometric detection in combination with a 96-well-plate has been developed for high throughput screening of total antioxidant capacity. It is based on the reaction between dichromate and antioxidants Chromium reducing antioxidant capacity (CHROMAC) assay. Antioxidant reduces dichromate leading to a decrease of dichromate concentration, in which reacts further with triiodide reagent. The slow reaction between antioxidant and dichromate takes place in parallel in a 96-well microplate, with the reaction time sufficiently long to reach steady state conditions. Microliter volumes of the remaining dichromate solution were manually injected into the FI amperometric system. Reaction with iodide in acidic medium produces triiodide which undergoes electrochemical reduction on a glassy carbon working electrode at 200?mV versus a Ag/AgCl reference electrode. The decrease of electrical current was directly proportional to the antioxidant capacity. The optimum conditions have been achieved as follow: 160?mg?L?1 of potassium dichromate, pH of dichromate solution of 2.82, 0.005?mol?L?1 of potassium iodide, 0.20?mol?L?1 of hydrochloric acid, and 3.0?mL?min?1 total flow rate. The developed method was applied for the determination of total antioxidant capacity of tea and herbal infusions and fruit juice samples. The results obtained indicated that the developed method had good correlation with the batch CHROMAC spectrophotometric method and 1,1-diphenyl-2-picrylhydrazyl scavenging assay. The proposed method provides fast and high throughput analysis, convenient operation, and low consumption of chemical reagents and samples.  相似文献   

14.
In this work a partially reduced graphene oxide (p‐RGO) modified carbon ionic liquid electrode (CILE) was prepared as the platform to fabricate an electrochemical DNA sensor, which was used for the sensitive detection of target ssDNA sequence related to transgenic soybean A2704‐12 sequence. The CILE was fabricated by using 1‐butylpyridinium hexafluorophosphate as the binder and then p‐RGO was deposited on the surface of CILE by controlling the electroreduction conditions. NH2 modified ssDNA probe sequences were immobilized on the electrode surface via covalent bonds between the unreduced oxygen groups on the p‐RGO surface and the amine group at the 5′‐end of ssDNA, which was denoted as ssDNA/p‐RGO/CILE and further used to hybridize with the target ssDNA sequence. Methylene blue (MB) was used as electrochemical indicator to monitor the DNA hybridization. The reduction peak current of MB after hybridization was proportional to the concentration of target A2704‐12 ssDNA sequences in the range from 1.0×10?12 to 1.0×10?6 mol/L with a detection limit of 2.9×10?13 mol/L (3σ). The electrochemical DNA biosensor was further used for the detection of PCR products of transgenic soybean with satisfactory results.  相似文献   

15.
Titanium dioxide nanoparticle/gold nanoparticle/carbon nanotube (TiO2/Au/CNT) nanocomposites were synthesized, and then characterized using scanning electron microscopy (SEM), transmission electron microscopy (TEM), and energy dispersive X-ray spectroscopy (EDX). A TiO2/Au/CNT nanocomposite-modified glassy carbon (GC) electrode was prepared using the drop coating method and was investigated using electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), differential pulse voltammetry (DPV), and amperometric current–time response (I-T). The modified material is redox-active. The nonenzymatically detected amount of ascorbic acid (AA) on the TiO2/Au/CNT electrode showed a linear relationship with the AA concentration, for concentrations from 0.01 to 0.08 μM; the sensitivity was 117,776.36 μA?·?cm?2?·?(mM)?1, and the detection limit was 0.01 μM (S/N?=?3). The results indicated that the TiO2/Au/CNT nanocomposite-modified GC electrode exhibited high electrocatalytic activity toward AA. This paper describes materials consisting of a network of TiO2, Au, and MWCNTs, and the investigation of their synergistic effects in the detection of AA.  相似文献   

16.
《Analytical letters》2012,45(4):805-815
Abstract

This paper describes a kinetic spectrophotometric method for the determination of L‐ascorbic acid (AA) and thiols (RSH). Absorbance of Fe(II)‐phen complex formed during the reaction of AA or RSH with Fe(III)‐phen was continuously measured at 510 nm by double‐beam spectrophotometer with flow cell. For determination some thiols, the catalytic effect of Cu2+ ions was used. AA and RSH can be determined in concentration ranges from 4.0×10?6 to 4.0×10?5 M and from 8.0×10?6 to 8.0×10?5 M, respectively. The applicability of the proposed method was demonstrated by determination of chosen compounds in pharmaceutical dosage forms.  相似文献   

17.
《Analytical letters》2012,45(5):875-886
Abstract

Platinum nanowires (PtNW) were prepared by an electrodeposition strategy using nanopore alumina template. The nanowires prepared were dispersed in chitosan (CHIT) solution and stably immobilized onto the surface of glassy carbon electrode (GCE). The electrochemical behavior of PtNW‐modified electrode and its application to the electrocatalytic reduction of hydrogen peroxide (H2O2) are investigated. The modified electrode allows low potential detection of hydrogen peroxide with high sensitivity and fast response time. As an application example, the glucose oxidase was immobilized onto the surface of PtNW‐modified electrode through cross‐linking by glutaric dialdehyde. The detection of glucose was performed in phosphate buffer at –0.2 V. The resulting glucose biosensor exhibited a short response time (<8 s), with a linear range of 10?5?10?2 M and detection limit of 5×10?6 M.  相似文献   

18.
《Analytical letters》2012,45(3):459-470
Abstract

A highly sensitive electrochemical biosensor for the detection of trace amount of 1‐naphthol was designed. Acid‐denatured DNA were immobilized onto the pretreated glassy carbon electrode (GCE(ox)) surface. Two well‐defined oxidation peaks were observed on the denatured DNA‐modified GCE(ox) at about +0.80 V and +1.10 V (vs. Ag/AgCl) in 0.10‐M acetate buffer (pH 5.0). The peak current of the guanine residue decreased with increasing concentration of 1‐naphthol. The optimum experimental conditions for the detection of 1‐naphthol were explored, and the calibration was linear for 1‐naphthol in the range of 1.0×10?8?1.1×10?6 M, with a correlation coefficient of 0.998. The limit of detection (LOD) was 5.0×10?9 M (S/N=3).  相似文献   

19.
《Analytical letters》2012,45(17):3182-3194
Abstract

It is the first time that Horseradish peroxidase (HRP) was successively immobilized on the magnetic cobalt nanoparticles modified ITO (indium tin oxide) electrode. Morphologies of electrode surface were featured by the field emission‐scanning electron microscope (FSEM). Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to characterize the modified process of electrode. Direct electrochemistry and electrocatalysis of HRP immobilized on nano‐Co/ITO were investigated. The biosensor exhibited high sensitivity, good stability, and excellent electrocatalytic activity to the reduction of H2O2. Under the optimized experimental conditions, a calibration curve over 2.0×10?9~2.0×10?8 mol l?1 and 2.0×10?7~2.0×10?6 mol l?1, with a limit of detection of 1.9×10?9 mol l?1 was obtained. The apparent Michaelis‐Menten constant (K M app ) for HRP/nano‐Co/ITO electrode was calculated to be 0.79 mmol l?1, indicating a higher affinity of HRP attached on the modified electrode.  相似文献   

20.
A new analytical methodology for the electrochemical detection of the herbicide maleic hydrazide (3,6‐dihydroxypyridazine) by flow injection analysis is presented. This method is supported by the novel application of a palladium‐dispersed carbon paste electrode as an amperometric sensor for this herbicide. Maleic hydrazide shows anodic electrochemical activity on carbon‐based electrodes (glassy carbon or carbon paste electrodes) in all the pH range. This electrochemical activity is enhanced using metal‐dispersed carbon paste electrodes, especially at Pd‐dispersed CPE which displays good oxidation signals at 690 mV (0.050 M phosphate buffer pH 7.0), 140 mV lower than at unmodified electrodes. Under the optimized conditions, the electroanalytical performance of Pd‐dispersed CPE in flow injection analysis was excellent, with good reproducibility (RSD 3.3%) and a wide linear range (1.9×10?7 to 1.0×10?4 mol L?1). A detection limit of 1.4×10?8 mol L?1 (0.14 ng maleic hydrazide) was obtained for a sample loop of 100 μL at a fixed potential of 700 mV in 0.050 M phosphate buffer solution at pH 7.0 and a flow rate of 2.0 mL min?1. The proposed method was applied for the maleic hydrazide detection in natural drinking water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号