首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《Analytical letters》2012,45(15):2591-2605
Abstract

A new PVC membrane electrode for lead ions, based on bis[(1-hydroxy-9,10-anthraquinone)-2-methyl]sulfide as membrane carrier, was prepared. The sensor exhibits a Nernstian response for Pb2+ over a wide concentration range (5.6 × 10?3-4.0 × 10?6 M). It has a response time of about 30 s and can be used for at least 3 months without any divergence in potentials. The proposed membrane sensor revealed good selectivities for Pb2+ over a wide variety of other metal ions. It was used as an indicator electrode in potentiometric titration of lead ion.  相似文献   

2.
《Analytical letters》2012,45(1):17-28
ABSTRACT

A PVC membrane electrode for Pb2 ions based on tetraphenylporphyrin was prepared. The sensor exhibits a Nernstian response for lead ions over a wide concentration range (1.0 x 10?5-1.0 x 10?2 M). The limit of detection is 8.5 x 10?6M. It has a response time of 15 s and can be used for at least three months without any divergence in potential. The proposed electrode shows a fairly good discriminating ability towards Pb2 ion in comparison to some alkali, alkaline earth, transition and heavy metal ions. The electrode can be used in the pH range 5.0 to 7.5. It was used as an indicator electrode in potentiometric titration of lead ion.  相似文献   

3.
A new PVC-membrane electrode for Co2+ ions based on N,N′-di(thiazol-2-yl)formimidamide (TF) as membrane carrier has been developed. The electrode resulted in Nernstian response (29.5?±?0.4?mV decade?1) for Co2+ ion over a wide concentration range (2.5?×?10?7 ?1.0?×?10?1?M) with a detection limit of 6.1?×?10?8?M. The sensor has a response time of about 10?s, and can be used for at least 2 months without observing any deviation from the Nernstain response. The electrode revealed good selectivity towards cobalt(II) ion over a wide variety of alkali, alkaline earth, transition, and heavy metal ions and could be used in the pH range 2.0–7.0. The electrode was used for determination of Co2+ in real samples.  相似文献   

4.
《Analytical letters》2012,45(8):1501-1512
ABSTRACT

A poly (vinyl chloride) (PVC) based membrane of cephaloridine as a novel ionophore exhibits good potentiometric response for Cu2+ over a wide concentration range (10?5-10? M) with a slope of 28.5 mV per decade. The detection limit is 3.5 × 10?6 M. The response time of the sensor is < 60 s. The electrode has been used for a period of one month and exhibits good selectivity towards Cu2+ in comparison to alkali, alkaline earth, transition and heavy metal ions, with no interference caused by Pb2+ Cd2+ and Fe2+ which are known to interfere with many other copper electrodes. The electrode can be used in the pH range from 4.0 to 6.5 and it can also be used in partially non-aqueous medium having up to 10 (v/v) non aqueous content and in the presence of cationic surfactants at concentrations less than 10?3 M.  相似文献   

5.
《Analytical letters》2012,45(15):3139-3152
ABSTRACT

A PVC membrane sensor for Nickel (II) ions based on 2,5-thiophenyl bis(5-tert-butyl-1,3-benzoxazole) as membrane carrier was prepared. The sensor exhibits a Nernstian response for Ni2+ ions over a wide concentration range (10?2–10?5M). It has a relatively fast response time and can be used for at least 2 months without any considerable divergence in potentials. The nature of the plasticizer, the additive, the concentration of internal solutions in the electrodes and the composition of the membrane were investigated. The proposed membrane electrode revealed very good selectivities for Ni2+ over a wide variety of other metal cations and could be used in pH range of 4.0–8.0. It was successfully applied for the direct determination of Ni2+ in solution and as an indicator electrode in potentiometric titration of nickel ion in both water and 85% acetonitrile solutions.  相似文献   

6.
A highly selective polyvinylchloride (PVC) membrane electrode based on Schiff base complex i.e. [Cobalt (Salpen) (PBu3)] ClO4 · H2O (Salpen = bis(salycilaldehyde)propylene diamine) is reported as new carrier for thiocyanate selective electrode by incorporating the membrane ingredients on the surface of graphite electrodes. The proposed electrode possesses a very wide Nernestian linear range to thiocyanate from 1.0 × 10?6 to 1.0 × 10?1 M with slope of ?59.05 ± 0.91 mV per decade of thiocyanate concentration, very low detection limit (8.0 × 10?7 M) and good thiocyanate selectivity over the wide variety of other anions. Fast and stable response, good reproducibility, long-term stability, applicability over a wide pH range (2.8–9.8) are advantages of the reported electrode. The sensor has a response time of <5 s and can be used for at least 14 weeks without any considerable change in respective potential response. The proposed electrode was used for the determination of thiocyanate in saliva, wastewater and human urine with satisfactory results and good agreement with colorimetric as reference method.  相似文献   

7.
《Analytical letters》2012,45(11):2169-2181
ABSTRACT

A new PVC membrane for zinc ions based on DBDA15C4 as membrane carrier was prepared. The electrode shows a linear stable response over a wide concentration range (5.0 × 10?5-1.0 × 10?1 M) with a slope of 22 mV/decade and a limit of detection of 3.0 × 10?5 M (2.0 μg/ml). It has a very short response time of less than 5 s and can be use for at least 11 months without any divergence in potential. The zinc ion-selective electrode exhibited very good selectivities with respect to alkali, alkaline earth and some transition and heavy metal ions and could be used in a pH range 1.5-7.0. It was successfully applied for the direct determination of zinc in a pharmaceutical sample and, as an indicator electrode, in potentiometric titration of Zn2+ ions.  相似文献   

8.
A highly selective PVC‐membrane electrode based on 2,6‐diphenylpyrylium fluoroborate is presented. The electrode reveals a Nernstian potentiometric response for sulfate ion over a wide concentration range (5.0 × 10?6‐1.0 × 10?1 M). The electrode has a response time of about 10 s and can be used for at least 2 months without any divergence. The proposed sensor revealed very good selectivities for sulfate over a wide variety of common organic and inorganic anions and could be used over a wide pH range (2.5–9.5). The detection limit of the sensor is 3.0 × 10?6 M. It was successfully applied to the direct determination of salbutamol, paramomycin tablets, and as an indicator electrode for potentiometric titration of sulfate ions with barium ions.  相似文献   

9.
《Analytical letters》2012,45(9):1714-1735
Abstract

Highly selective poly(vinyl chloride) (PVC) membrane electrode based on recently synthesized mercury complex i.e., phenyl mercury (II) (2‐mercaptobezothiozolate) (PMMBT) as new carrier for iodide‐selective electrode by incorporating the membrane ingredients on the surface of graphite electrode are reported. The effect of various parameters including the membrane composition, pH, and possible interfering anions were investigated on the response properties of the electrode. The developed sensor exhibited Nernstian responses toward iodide over a wide concentration range of 1×10?7 to 0.1 M with slopes of 57.6±0.8 mV per decade of iodide concentration and detection limit of 8×10?8 M, over a wide pH ranges of 2.0–11.5. The sensors have response time of 0.5 s and can be used for at least 2 months without any considerable divergence in their potential response. The proposed electrode show good ability to discriminate iodide over several inorganic and organic anions.

The electrode was successfully applied to direct determination of iodide in synthetic mixture, waste water and drinking water, and pharmaceutical samples in addition to applying as indicator electrode in precipitation titration.  相似文献   

10.
A new polystyrene based membrane electrode of methyl substituted 6,7:13,14-dibenzo-2,4,9,11-tetraphenyl-1,5,8,12-tetraazacyclotetradeca-1,4,6,8,11,13-hexaene (I) with sodium tetraphenylborate (NaTPB) and dibutyl phthalate (DBP) as anion excluder and plasticizing agent was prepared and investigated as Hg (II)-selective electrode. The electrode exhibits a Nernstian response for Hg (II) ions over a wide concentration range of 1.0 × 10−1–8.9 × 10−6 M with a slope of 30 ± 1 mV per decade concentration. It has a response time of 10 s and can be used for at least 4 months without any divergence in potentials. The membrane works satisfactorily in a partially non-aqueous medium up to a maximum 30% (v/v) content of methanol and ethanol. The proposed sensor revealed good selectivity over a wide variety of other cations including alkali, alkaline earth, heavy and transition metal ions and could be used in a pH range of 2.5–5.0. Normal interferents like Ag+, Cd2+ and Pb2+ low interfere in the working of the electrode. The electrode was successfully used in the direct determination of Hg2+ in aqueous solution.  相似文献   

11.
《Analytical letters》2012,45(13):2611-2629
ABSTRACT

New potentiometric membranesensorsresponsive to Pb(II) have been developed. The membrane sensors are based on three different 9, 10-anthraquinone derivatives. The electrode based on 1, 4-bis (prop-21-enyloxy)-9, 10-anthraquinone exhibits a good Nernstian response for Pb(II) ions over a wide concentration range (2.5×10?6 - 1.0×10?2 M) with a slope of 29.8 mV decade?1. Detection limit is 1.5×10?6 M. The response time of the sensor is 15s and the useful working pH range is 4.7-6.8. The membrane can be used for more than 4 months without any considerable divergence in potentials. The electrodes revealed comparatively good selectivities with respect to alkali, alkaline earth and some transition and heavy metal ions. It was used as an indicator electrode in potentiometric titration of lead ions (with sulfate and oxalate ions), and for the determination of lead in waste waters.  相似文献   

12.
The two podand chelates based on diethylsulfide, 1,5‐bis(2′‐hydroxy‐4′‐nitrophenoxy)‐3‐thiapentane (L1) and 1,5‐bis(8′‐oxybenzopyridine)‐3‐thia pentane (L2), have been synthesized and explored as neutral ionophores for preparing poly(vinyl chloride) based membrane electrodes selective to Pb2+. The addition of anionic additives and various plasticizers has been found to substantially improve the performance of the electrode. The best performance was obtained with the electrode No. 1 having a membrane of ionophore (L1) with the composition PVC:o‐NPOE:ionophore (L1):NaTFPB (%w/w) of 33 : 62 : 3 : 2. The electrode exhibits Nernstian response with a slope of 31.57±0.3 mV decade?1 of activity in the concentration range from 2.0×10?9 to 1.0×10?1 M Pb2+, performs satisfactorily over a wide pH range (1.6–7.0), with a fast response time (5 s).  相似文献   

13.
A pyrimidine derivative, [(4,6-dimethyl-2-pyrimidinyl)thio] acetic acid (Hdpmta) has been synthesized and used as an ionophore in a Pb2+-selective electrode. The electrode works well over a wide range of concentration (1.0?×?10?5 to 1.0?×?10?2?mol?L?1) with the response slope of 27.4?mV?decade?1. The electrochemical behavior of Hdpmta on glassy carbon electrode shows that in 0.1?mol?L?1 TBAP/DMF solution, it has a well-defined irreversible cathodic peak at ?0.83?V. The electrode process involves single electron transfer. Furthermore, a novel Pb(II) complex, [Pb(μ 2-dpmta)2(H2O)2] n (1), has been synthesized through self-assembly of Pb(OAc)2 with Hdpmta in aqueous solution and characterized by elemental analysis and IR spectra. X-ray diffraction analysis shows that 1 is a 1D chain structure consisting of two kinds of rhomboidal Pb2O2 rings, in which a large amount of H-bonding is involved. By π–π interactions parallel chains are further assembled to a 2D supramolecular network. The UV, TG and photoluminescence properties of 1 have also been investigated.  相似文献   

14.
《Electroanalysis》2003,15(19):1561-1565
A highly selective membrane electrode for the determination of ultratrace amounts of lead was prepared. The PVC membrane electrode based on 2‐(2‐ethanoloxymethyl)‐1‐hydroxy‐9,10‐anthraquinone (AQ), directly coated on graphite, exhibits a good Nernstian response for Pb(II) ions over a very wide concentration range (1.0×10?7–1.0×10?2 M) with a limit of detection of 8.0×10?8 M. It has a fast response time of ca. 10 s and can be used over a period 2 months with good reproducibility (SD=±0.2 mV). The electrode revealed a very good selectivity respect to common alkali, alkaline earth, transition and heavy metal ions and could be used in the pH range of 3.5–6.8. It was used as an indicator electrode in potentiometric titration of lead ions with chromate and oxalate, and in indirect determination of lead in spring water samples.  相似文献   

15.
《Analytical letters》2012,45(15):2444-2459
Abstract

Polymeric membrane electrodes (PMEs) and coated graphite electrodes (CGEs) containing 1,3,4-trisubstituted-2-azetidinone derivatives as ion carriers are reported here for bismuth(III) ion selectivity. These electrodes exhibited Nernstian response for Bi3+ ions over a wide concentration range (5.0 × 10?7 M to 1.0 × 10?1 M for CGE) with a lower detection limit of 3.98 × 10?7 M (for CGE) and wide pH range (1.3–5.0). Compared to polymeric membrane electrode, the coated graphite electrode has shown better selectivity for Bi3+ ions with respect to common metal ions. Proposed electrodes have been used for the estimation of Bi3+ ions in pharmaceutical and glass samples.  相似文献   

16.
《Electroanalysis》2006,18(12):1186-1192
A PVC membrane electrode using [Bzo2Me2Ph2(16)hexaeneN4] ( I ) as ionophore, oleic acid as lipophilic additive and o‐nitrophenyloctyl ether as plasticizer has been investigated as Zn(II)‐selective electrode. The membrane incorporating 34.9% (w/w) PVC, 2.3% I , 4.7% OA and 58.1% o‐NPOE gave linear response over the concentration range 2.82×10?6?1.0×10?1 M with a Nernstian slope of 28.5±0.2 mV/decade of concentration with a detection limit of 2.24×10?6 M (0.146 ppm) and showed a response time of less than 10 s and could be used in pH range 2.5–8.5. High selectivity was obtained over a wide variety of metal ions. The proposed electrode was successfully used as an indicator electrode in potentiometric titration of zinc ions with EDTA and for determination of zinc in real samples.  相似文献   

17.
《Analytical letters》2012,45(4):683-695
Abstract

A highly selective and sensitive triiodide sensor based on a 2‐(((2‐(((E)‐1‐(2‐hydroxy phenyl) methylidine) amino) phenyl) imino) methyl) phenol with iodine (CTC) as membrane carrier was developed. The electrode revealed a Nernstian behavior over a very wide triiodide‐ion concentration range (5.0×10?8–1.0×10?2 M), and relatively low detection limit (3.0×10?8 M). The potentiometric response is independent of the pH of solution in the pH range of 3.0–10.0. The electrodes manifest advantages of low resistance, very fast response (<12 s), and most importantly, good selectivities relative to a wide variety of inorganic and organic anions, including iodide, bromide, chloride, fluoride, sulfite, sulfate, cyanide, thiocyanate, and acetate. In fact, the selectivity behavior of the proposed triiodide ion‐selective electrode shows great improvements compared to the previously reported electrodes for the triiodide ion. The proposed membrane sensor can be used for at least 6 months without any significant divergences in the potential. The electrode was successfully applied as an indicator electrode in the titration of triiodide with thiosulfate ion.  相似文献   

18.
《Analytical letters》2012,45(19):1557-1563
Abstract

Solid membranes of copper hexacyanoferrate (III) in Areldite are evaluated as thallium (I) sensitive electrode. The membrane electrode gave a linear near Normstian response to thallium (I) ions in the concentration range 10?1 - 5 × 10?4 M and can be used to estimate T1 (I) down to 10?4 M. The responses of the electrode is fast and steady potentials are obtained in less than a minute. The same membrane has been used over a period of six months without any appreciable drift in potential. The electrode can also be used satisfactory in partially non-aqueous media and in presence of a number of interfering ions. It is superior to the existing T1(I) solid membrane electrodes as it can function in alkaline range also.  相似文献   

19.
《Electroanalysis》2002,14(23):1621-1628
Copper phthalocyanine was used as ion carrier for preparing polymeric membrane selective sensor for detection of iodide. The electrode was prepared by incorporating the ionophore into plasticized poly(vinyl chloride) (PVC) membrane, coated on the surface of graphite electrode. This novel electrode shows high selectivity for iodide with respect to many common inorganic and organic anions. The effects of membrane composition, pH and the influence of lipophilic cationic and anionic additives and also nature of plasticizer on the response characteristics of the electrode were investigated. A calibration plot with near‐Nernestian slope for iodide was observed over a wide linear range of five decades of concentration (5×10?6?1×10?1 M). The electrode has a fast response time, and micro‐molar detection limit (ca. 1×10?6 M iodide) and could be used over a wide pH range of 3.0–8.0. Application of the electrode to the potentiometric titration of iodide ion with silver nitrate is reported. This sensor is used for determination of the minute amounts of iodide in lake water samples.  相似文献   

20.
2,5-Dioxo-4-imidazolidinyl was used as an excellent sensing material in the preparation of a PVC membrane for a Ce(III)-selective sensor. The electrode shows a good selectivity for the Ce(III) ion with respect to most common cations including alkali, alkaline earth, transition, and heavy metal ions. The developed sensor exhibits a wide linear response with a slope of 19.6?±?0.3 mV per decade over the concentration range of 1.0?×?10?6 to 1.0?×?10?1 M, while the illustrated detection limit is 5.7?×?10?7 M of Ce(III) ions. Moreover, it is concluded that the sensor response is pH-independent in the range of 3.1–9.8. The applications of the recommended electrode include the determination of concentration of Ce(III) ions in soil and sediment samples, validation with CRM's, and the Ce(III) ion potentiometric titration with EDTA as an indicator electrode.  相似文献   