共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper reports the use of a tetracycline (TC) sensor constructed from a combination of molecularly imprinted polymer (MIP) and gold nanoparticles modified multiwall carbon nanotubes (MWNTs‐GNPs). The results demonstrated that the amount of recognition sites in the polymer was significantly increased and the electron transfer ability of the sensor was improved. The relationship between the peak current and the TC concentration was linear in the range from 0.1 to 40 mg L?1, and the detection limit was 0.04 mg L?1 (S/N=3). The peak current to TC was 4.3, 6.2 and 6.8 times larger than that of oxytetracycline, chloramphenicol and nafcillin, respectively. Thus, the combination of MIP and MWNTs‐GNPs provides a sensitive and selective electrochemical detection method for tetracycline. 相似文献
2.
以水合肼为还原剂,采用均相还原法制备还原氧化石墨烯-多壁碳纳米管复合材料(rGO-MWCNTs),通过滴涂法将其修饰到玻碳电极(GCE)表面.以此复合材料为载体,采用电化学方法制备了金纳米粒子-还原氧化石墨烯-多壁碳纳米管复合膜修饰电极(AuNPs-rGO-MWCNTs/GCE).通过扫描电镜(SEM)、EDS能谱技术和电化学方法对此电极进行了表征.研究了双酚A在修饰电极上的电化学行为.结果表明,此电极对双酚A的电极过程具有良好的电化学活性,在0.10 mol/L PBS溶液(pH 7.0)中,微分脉冲伏安法测定双酚A的线性范围为5.0 × 10-9~1.0 × 10-7 mol/L和1.0 × 10-7~2.0 × 10-5 mol/L,检出限为1.0 ×10-9 mol/L(S/N=3). 将此电极用于模拟水样和超市购物小票样品中双酚A含量的测定,加标回收率分别为97%~110%和98%~104%. 相似文献
3.
The nature of binding between Terazosin (TR) and gold nanoparticles (Au‐Nps) is investigated using UV‐vis and fluorescence spectroscopies, cyclic voltammetry, SEM, and EIS. The results suggest that Au‐Nps are effective carriers for TR. An electrochemical sensor for TR is introduced using Au‐Nps electrodeposited on carbon paste electrode. The effect of parameters including pH and scan rate on the response was investigated. A linear range from 8.0×10?9 to 5.4×10?5 mol L?1 with correlation coefficient of 0.9995 and detection limit of 1.2×10?10 mol L?1 was obtained. This sensor was used for determining TR spiked in urine, and excellent recovery results are achieved. 相似文献
4.
《Analytical letters》2012,45(18):2809-2822
Development and use of highly ordered, vertically aligned TiO2 nanotube arrays modified with gold nanoparticles for the selective detection of ascorbic acid (AA) in the presence of uric acid and glucose are reported here. Gold nanoparticles were electrodeposited on the Nanotube arrays by CV. The sensor was characterized using SEM, EDS, CV, and EIS. It showed very good performance with a sensitivity of 46.8 μA mM?1 cm?2, response time below 2 seconds and linearity in the range of 1 μM to 5 mM with a detection limit of 0.1 μM and was tested for the AA concentration in pharmaceutical preparations. 相似文献
5.
《Analytical letters》2012,45(6):996-1014
A novel electrochemical sensor for bisphenol A was developed through the combination of a molecular imprinting technique with a multiwalled carbon nanotube paste electrode. A molecularly imprinted polymer and nonimprinted polymer were synthesized in the presence and absence of bisphenol A, and then used to prepare the electrode. The bisphenol A imprinted polymer was applied as a selective recognition element in the electrochemical sensor. Differential pulse voltammetry was used to characterize the electrochemical behavior of bisphenol A at the modified electrodes. The results showed that the imprinted sensor had highest response for bisphenol A. Parameters including the carbon paste composition, pH, and adsorption time for the imprinted sensor were optimized. Under the optimized conditions, the differential pulse voltammetry peak current was linear with the concentration of bisphenol A from 0.08 to 100.0 µM, with a detection limit of 0.022 µM. The imprinted sensor for bisphenol A exhibited good selectivity, stability, and reproducibility. This sensor was successfully used for the determination of bisphenol A in real water samples. 相似文献
6.
A novel multilayer gold nanoparticles/multiwalled carbon nanotubes/glucose oxidase membrane was prepared by electrostatic assembly using positively charged poly(dimethyldiallylammonium chloride) to connect them layer by layer. The modification process and membrane structures were characterized by atomic force microscopy, scanning electron microscopy and electrochemical methods. This membrane showed excellent electrocatalytic character for glucose biosensing at a relatively low potential (?0.2 V). The Km value of the immobilized glucose oxidase was 10.6 mM. This resulting sensor could detect glucose up to 9.0 mM with a detection limit of 128 μM and showed excellent analytical performance. 相似文献
7.
A voltammetric sensor for sensitive and specific determination of trans‐resveratrol (RES) were prepared based on immobilization of an RES‐imprinted film on the surface of functionalized Indium Tin Oxide (ITO) electrode, which was modified with γ‐methacyloxypropyl trimethoxysilane (γ‐MPS). Cyclic Voltammetry (CV) was presented to extract RES from the molecularly imprinted polymer film and RES were extracted rapidly and completely. The binding performance of the imprinted electrode with the template RES were investigated using differential pulse voltammetry (DPV). The results showed that the imprinted ITO film can give selective recognition to the template RES over that of structurally analogous molecules. A linear response to RES in the concentration range of 2.0×10?6 M to 2.0×10?5 M was observed with a correlation coefficient of 0.992, and the detection limit of the electrochemical sensor was 8.0×10?7 M. Whereas, binding to the reference nonimprinted electrode, made in the same way but without the addition of template RES, there was almost no response to RES. 相似文献
8.
ener Salam Aysu Arman Ayem Üzer Belks Ustamehmetolu Esma Sezer Reat Apak 《Electroanalysis》2020,32(5):964-970
Dopamine (DA) is a significant neurotransmitter in the central nervous system, coexisting with uric acid (UA) and ascorbic acid (AA). UA and AA are easily oxidizable compounds having potentials close to that of DA for electrochemical analysis, resulting in overlapping voltammetric response. In this work, a novel molecularly imprinted (MI) electrochemical sensor was proposed for selective determination of DA (in the presence of up to 80‐fold excess of UA and AA), relying on gold nanoparticles (Aunano)‐decorated glassy carbon (GC) electrode coated with poly(carbazole (Cz)‐co‐aniline (ANI)) copolymer film incorporating DA as template (DA imprinted‐GC/P(Cz‐co‐ANI)‐Aunano electrode, DA‐MIP‐Aunano electrode). The DA recognizing sensor electrode showed great electroactivity for analyte oxidation in 0.2 mol L?1 pH 7 phosphate buffer. Square wave voltammetry (SWV) was performed within 10?4–10?5 mol L?1 of DA, of which the oxidation peak potential was observed at 0.16 V. The limit of detection (LOD) and limit of quantification (LOQ) were 2.0×10?6 and 6.7×10?6 mol L?1, respectively. Binary and ternary synthetic mixtures of DA‐UA, DA‐AA and DA‐UA‐AA yielded excellent recoveries for DA. Additionally, DA was quantitatively recovered from a real sample of bovine serum spiked with DA, and determined in concentrated dopamine injection solution. The developed SWV method was statistically validated against a literature potentiodynamic method using a caffeic acid modified‐GC electrode. 相似文献
9.
10.
11.
In this work, we report on the preparation of a simple, sensitive DNA impedance sensor. Firstly gold nanoparticles were electrodeposited on the surface of a gold electrode, and then probe DNA was immobilized on the surface of gold nanoparticles through a 5′‐thiol‐linker. Electrochemical impedance spectroscopy (EIS) was used to investigate probe DNA immobilization and hybridization. Compared to the bare gold electrode, the gold nanoparticles modified electrode could improve the density of probe DNA attachment and the sensitivity of DNA sensor greatly. The difference of electron transfer resistance (ΔRet) was linear with the logarithm of complementary oligonucleotides sequence concentrations in the range of 2.0×10?12 to 9.0×10?8 M, and the detection limit was 6.7×10?13 M. In addition, the DNA sensor showed a fairly good reproducibility and stability during repeated regeneration and hybridization cycles. 相似文献
12.
Yanli Zhang Yanpei Liu Jiemei He Pengfei Pang Yuntao Gao Qiufen Hu 《Electroanalysis》2013,25(5):1230-1236
A gold nanoparticle (AuNP) and graphene nanosheet (GN) modified glassy carbon electrode (GCE) is proposed as voltammetric sensor for caffeic acid assay. The sensor exhibits a surface‐confined and reversible process for oxidation of caffeic acid revealed by cyclic voltammetry. The results show more favorable electron transfer kinetics than the bare GCE. The linear response of the sensor is from 5×10?7 to 5×10?5 M with a detection limit of 5×10?8 M (S/N=3). The AuNP/GN nanocomposite shows more favorable electrochemical activity and should be a kind of more robust and advanced functional material, which provides a promising platform for electrochemical sensors and biosensors. The method was successfully applied to detect caffeic acid in pharmaceutical tablets with satisfactory results. 相似文献
13.
Voltammetric Determination of Sophoridine Based on Gold Nanoparticles/L‐cysteine/ Graphene Modified Glassy Carbon Electrode 下载免费PDF全文
A new strategy to make the electrochemical sensor was presented, through combining gold nanoparticles (GNPs) with reduced graphene oxide (rGO) via L‐cysteine (L‐cys) as crosslinker. The resulting electrodes were characterized by scanning electron microscopy (SEM) and electrochemical methods. And it was applied to develop a high‐sensitive electrochemical sensor for determination of sophoridine. Compared with the bare GCE and reduced graphene oxide modified electrode, the resulting electrodes exhibited excellent response toward the oxidation of sophoridine by significantly enhancing the oxidation peak currents and decreasing the overpotential of sophoridine. Under the selected conditions, there exist the linear relation between the oxidation peak currents and sophoridine concentration in the range of 1.0 x 10‐6~1.0 x 10‐4 mol L‐1, with detection limit of 4.0 x 10‐7 mol L‐1. At the same time, the method can be successfully applied to the quantitative determination of sophoridine in injection samples and its result is satisfactory. 相似文献
14.
以氧乐果为模板分子,邻苯二胺为功能单体,在碳纳米管修饰的玻碳电极表面通过电聚合方法制成氧乐果分子印迹聚合物膜,用无水乙醇洗脱后制备出对氧乐果有特异响应的电化学传感器。通过循环伏安法和电化学阻抗法对分子印迹传感器的电化学性能进行表征。以K_3Fe(CN)_6为探针,采用差分脉冲伏安法研究了该分子印迹传感器的分析性能,建立了氧乐果的间接测定方法。结果表明,K_3Fe(CN)_6的相对峰电流与氧乐果浓度在1.0×10~(-7)~2.0×10~(-6)mol/L范围内呈良好的线性关系,检出限为3.6×10~(-8)mol/L。 相似文献
15.
异烟肼在多壁碳纳米管修饰电极上的电化学行为及电化学测定 总被引:9,自引:0,他引:9
报道了一种测定异烟肼的化学修饰电极和电分析方法。与裸玻碳电极相比,多壁碳纳米管修饰玻碳电极显著提高异烟肼的氧化峰电流。优化了底液、pH值、修饰剂量、富集电位和富集时间等测定条件,建立了一种直接测定异烟肼的高灵敏度电分析方法。该方法测定异烟肼的线性范围为4×10-7~5×10-5mol/L;富集60 s后的检出限为1.5×10-7mol/L;对5×10-6mol/L的异烟肼平行测定10次的相对标准偏差为4.9%。此方法成功用于异烟肼片剂和血清中异烟肼含量的测定。 相似文献
16.
《Analytical letters》2012,45(10):1184-1196
The electrochemical detection of As(III) was investigated on the novel citrate stabilized gold nanoparticle modified glassy carbon electrode (AuNPs/GCE) in 1 M HCl by square wave anodic stripping voltammetry. AuNPs/GCE was prepared by simply casting citrate stabilized gold nanoparticles onto the well-polished glassy carbon electrode. Gold modification was evaluated by cyclic voltammetry, while transmission electron microscopy and UV-vis Spectroscopy revealed the size and distribution of gold nanoparticles. Anodic stripping voltammetry was performed with the modified electrode in As(III) solution. Electrochemical experiments proved that AuNPS/GCE exhibited good performance for As(III) analysis, the linear range were obtained between 0.05 and 1 ppb for trace level of As(III) as well as 1 to 15 ppb, with a limit of detection of 0.025 ppb. In terms of reproducibility, the precision of the aforementioned method in %RSD was calculated at 7.78% (n = 10), and the repeatability of the proposed method was calculated to be 1.59%. The application of the method to analyze As(III) in tap water was investigated. 相似文献
17.
多壁碳纳米管和分子印迹膜修饰电极检测猪尿液中莱克多巴胺 总被引:2,自引:0,他引:2
采用原位热聚合技术,分别以多壁碳纳米管(MWCNs)和分子印迹膜(MIM)修饰丝网印刷电极(SPE),与多壁碳纳米管和非分子印迹膜(NIM)修饰的丝网印刷电极组合在一起,并将其组合的丝网印刷电极通过电极插口与便携式电导仪相连接,组装成检测莱克多巴胺残留的电导型传感器,优化检测条件,并建立了检测莱克多巴胺的标准曲线,测试了实际猪尿样中莱克多巴胺的含量.通过扫描电镜分析了该分子印迹膜的表征结构.结果表明,在莱克多巴胺分子印迹膜表面形成了大量印迹微孔.本传感器装置检测莱克多巴胺具有很高的灵敏度和特异性,检出限为0.033 mg/L,线性范围为0.33~8.0 mg/L,基于猪尿样的检测回收率达到91%~98%,可实现现场快速检测. 相似文献
18.
A new method for the determination of trace copper was described. A multiwalled carbon nanotube modified carbon paste electrode was prepared and the adsorptive voltammetric behavior of copper‐alizarin red S (ARS) complex at the modified electrode was investigated. By use of the second‐order derivative linear sweep voltammetry, it was found that in 0.04 mol/L acetate buffer solution (pH 4.2) containing 4×10?6 mol/L ARS, when accumulation potential is 0 mV, accumulation time is 60 s and scan rate is 100 mV/s, the complex can be adsorbed on the surface of the electrode, yielding one sensitive reduction peak at ?172 mV (vs. SCE). The peak current of the complex is proportional to the concentration of Cu(II) in the range of 2.0×10?11–4.0×10?7 mol L?1 with a detection limit (S/N=3) of 8.0×10?12 mol/L (4 min accumulation). The proposed method was successfully applied to the determination of copper in biological samples with satisfactory results, the recoveries were found to be 96%–102%. 相似文献
19.
A Non‐Enzymatic Hydrogen Peroxide Sensor Based on Gold Nanoparticles/Carbon Nanotube/Self‐Doped Polyaniline Hollow Spheres 下载免费PDF全文
In this study, a novel non‐enzymatic hydrogen peroxide (H2O2) sensor was fabricated based on gold nanoparticles/carbon nanotube/self‐doped polyaniline (AuNPs/CNTs/SPAN) hollow spheres modified glassy carbon electrode (GCE). SPAN was in‐site polymerized on the surface of SiO2 template, then AuNPs and CNTs were decorated by electrostatic absorption via poly(diallyldimethylammonium chloride). After the SiO2 cores were removed, hollow AuNPs/CNTs/SPAN spheres were obtained and characterized by transmission electron microscopy (TEM), field‐emission scanning electron microscopy (FESEM) and Fourier transform infrared spectroscopy (FTIR). The electrochemical catalytic performance of the hollow AuNPs/CNTs/SPAN/GCE for H2O2 detection was evaluated by cyclic voltammetry (CV) and chronoamperometry. Using chronoamperometric method at a constant potential of ?0.1 V (vs. SCE), the H2O2 sensor displays two linear ranges: one from 5 µM to 0.225 mM with a sensitivity of 499.82 µA mM?1 cm?2; another from 0.225 mM to 8.825 mM with a sensitivity of 152.29 µA mM?1 cm?2. The detection limit was estimated as 0.4 µM (signal‐to‐noise ratio of 3). The hollow AuNPs/CNTs/SPAN/GCE also demonstrated excellent stability and selectivity against interferences from other electroactive species. The sensor was further applied to determine H2O2 in disinfectant real samples. 相似文献
20.
《Analytical letters》2012,45(7):1132-1144
Molecular imprinting and sol-gel technique were combined to develop a molecular imprinted polymer (MIP) based electrochemical sensor in this work. With the successive modification of multi-walled carbon nanotubes (MWNTs) and gold nanoparticles (GNPs), a modified glassy carbon electrode (GCE) was immersed in a sol-gel solution in the presence of paracetamol (PR) for the electropolymerization to fabricate an imprinted sensor. Scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS), and differential pulse voltammetry (DPV) were employed to characterize the constructed sensor. The factors for the sensor preparation, the electropolymerization potential range, the monomer concentration, and the scan rate for the sensor preparation were optimized. The sensor displayed an excellent recognition capacity toward PR compared with other analogues. Additionally, the DPV peak current was linear to the PR concentration in the range from 8.0 × 10?8 to 5.0 × 10?5 mol/L, with a detection limit of 4.0 × 10?8 mol/L. The prepared sensor also showed satisfactory reproducibility and regeneration capacity. 相似文献