首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《Analytical letters》2012,45(6):1033-1045
The amoxicillin-imprinted polymer was synthesized with methacrylic acid (MAA) as a functional monomer and ethylene glycol dimethacrylate (EGDMA) as a cross-linker. The binding characteristic of the imprinted polymer to amoxicillin was evaluated by equilibrium binding experiments. Using the imprinted polymer as recognition material, 3-(3′-nitrophenyl)-5(2′-sulfonylphenylazo)-rhodanine (4NRASP) was synthesized by the authors and was used as chemiluminescence (CL) reagent. A novel chemiluminescence (CL) sensor for the determination of amoxicillin was developed based on the CL reaction of amoxicillin with potassium permanganate in an acidic medium. The sensor displayed excellent selectivity and high sensitivity. The linear response range of the sensor was from 5.0 × 10?9 to 1.0 × 10?6 g · mL?1 (r = 0.9985) and the detection limit was 1.3 × 10?9 g · mL?1. The relative standard deviation for the determination of 1.0 × 10?7 g · mL?1 amoxicillin solution was 1.7% (n = 11). The sensor was applied to the determination of amoxicillin in urine samples with satisfactory results.  相似文献   

2.
A method for flow injection with chemiluminescence (CL) detection has been developed for the determination of proteins. It is based on the luminescence of the N-bromosuccinimide-fluorescein-protein system, where fluorescein is used as an energy transfer reagent in alkaline medium. The CL of the system is strongly enhanced by hexadecyl trimethyl ammonium bromide. Optimum conditions and possible mechanisms have been investigated. Under optimum experimental conditions, the linear range is from 0.4 to 40 µg·mL?1 for egg albumin, 0.2 to 20 µg·mL?1 for bovine serum albumin, and from 1 to 100 µg·mL?1 for bovine hemoglobin. The detection limits are 37, 62, and 240 ng·mL?1, respectively.  相似文献   

3.
Rifampicin can enhance the chemiluminescence (CL) of peroxomonosulfate‐cobalt(II) system, and the CL intensity is strongly dependent on the rifampicin concentrations. Based on this phenomenon, a rapid and sensitive flow injection CL method was developed for the determination of rifampicin. The relative CL intensity was linear with the rifampicin concentration over the range of 5×10?8 to 1×10?6 g·mL?1 (r=0.9991), the detection limit was 7×10?9 g·mL?1 (S/N=3), and the relative standard deviation was 2.7% for 6×10?7 g·mL?1 rifampicin (n=11). Furthermore, this method was successfully applied to the determination of rifampicin in real eye drop and capsules sample.  相似文献   

4.
《Analytical letters》2012,45(5):973-983
Abstract

A rapid and sensitive flow‐injection chemiluminescence (FI‐CL) method, which is based on the CL intensity that generated from the redox reaction of Ce(IV)‐rhodamine B in H2SO4 medium, for the determination of acyclovir and gancyclovir is described. For acyclovir, the determination range is 3×10?8 g mL?1–7×10?5 g mL?1, with 1.56×10?8 g mL?1 as its determination limit. During 11 repeated measurements for 1×10?6 g mL?1 acyclovir, the relative standard deviation was 2.08%. For gancyclovir, the determination range was 5×10?8 g mL?1–7×10?5 g mL?1, with 2.35×10?8 g mL?1 as its determination limit. The relative standard deviation is 2.83% with 11 repeated measurements of 1×10?6 g mL?1 gancyclovir. This method can be successfully used to determine the content of acyclovir and gancyclovir in injections, acyclovir in eye drops, and, maybe, also for other ciclovirs.  相似文献   

5.
A novel flow injection procedure has been developed for the determination of gallic acid based on the enhancement function for luminol‐AgNO3‐Ag NPs chemiluminescence (CL) system by gallic acid. The enhancement mechanism was proposed for the reinforcing effect of the gallic acid on the CL system. The UV‐vis absorption spectrum and CL emission spectrum were applied to confirm the mechanism. The method is simple, rapid and sensitive with a detection limit of 5×10?10 g·mL?1 and a linear range of 8.0×10?10–1.0×10?7 g·mL?1. The relative standard deviation (RSD) is 1.3% for eleven measurements of 5×10?8 g·mL?1 gallic acid. The method has been successfully applied to the determination of gallic acid in Chinese proprietary medicine–Jianmin Yanhou tablets and synthesized samples.  相似文献   

6.
A sensitive and high selective chemiluminescence (CL) method was developed for the determination of lincomycin in acid medium using diperiodatonickelate as a reagent. The mechanism leading to luminescence is discussed by comparing the spectra of fluorescence and CL. Relative CL intensity is linear in the range from 8.0 ng mL?1 to 1.0 µg mL?1, the limit of detection is 2.5 ng mL?1 (3σ), and the relative standard deviation is 4.0% at 0.1 µg mL?1 of lincomycin (n?=?7). The method was successfully applied to the determination of lincomycin in injections, human urine, and in serum samples.  相似文献   

7.
《Analytical letters》2012,45(12):1933-1941
Abstract

A rapid and simple flow‐injection chemiluminescence (CL) method is described for the determination of perphenazine, which is based on the CL intensity that generated from the redox reaction of Ce (IV)-perphenazine in HNO3 medium is proportional to the perphenazine concentration without any sensitizers. The proposed method allows the determination range within 1.0×10?7–7.0 ×10?5 g mL?1 with a detection limit of 8.0×10?8 g mL?1, and it has been successfully applied to the determination of the perphenazine in pharmaceutical tablet compared well with the official method.  相似文献   

8.
We report herein a novel chemiluminescence (CL) phenomenon triggered by light irradiation when a fluorescent dye, for example hematoporphyrin, fluorescein, eosin, or methylene blue is present in the luminol solution. A possible mechanism is proposed for the photoinduced chemiluminescence (PICL) reaction. Compared with reported methods for CL triggering, for example flow-injection, static reagent injection, and the electrochemical technique, the proposed in-situ PICL method presented has three advantages. First, the method is more selective, because the PICL signal of the target fluorescent dyes is initiated by excitation at a selective wavelength only. Second, the space and time resolution of the PICL method are better. Last, and most important, compared with injecting a reagent or inserting a electrode into the CL system to initiate the CL reaction, with the in-situ PICL method there is no physical interference with the target detecting system. All these advantages of the PICL method indicate it has many potential applications in the analytical sciences. The proposed method was applied to analysis of urine containing adrenaline. The linear range for adrenaline is 2.0?×?10?10–1.0?×?10?7 g mL?1 and the detection limit is 6.0?×?10?11 g mL?1.
Figure
Schematic PICL Mechanism for the CL reagents-fluorescence dyes systems  相似文献   

9.
《Analytical letters》2012,45(14):2026-2036
A novel chemiluminescence (CL) system was established for the determination of diammonium glycyrrhizinate (DG) in pharmaceutical preparations and its ability of scavenging hydroxyl radical. It was shown that a strong CL signal was observed when Eosin Y mixed with Fenton reagent. The CL intensity was decreased significantly when DG was added to the reaction system and partially scavenged the hydroxyl radicals in the solution. The extent of decrease in the CL intensity had a good stoichiometrical relationship with DG concentration. Based on this, we developed a new method for the determination of DG using a flow injection chemiluminescence (FI-CL) technique. Under the optimal conditions, the linear range of DG concentration was 6.0 × 10?8–5.0 × 10?6 mol/L (R = 0.9982) with a detection limit of 8.0 × 10?9 mol/L (SN = 3), and the RSD was 3.8% for 2.0 × 10?7 mol/L DG (n = 11). This method was successfully used in the determination of DG in tablets and the evaluation of hydroxyl radical scavenging capacity of DG. The possible reaction mechanism of the CL system is discussed.  相似文献   

10.
《Analytical letters》2012,45(18):3405-3416
Abstract

A post‐chemiluminescence (PCL) was observed when loperamide hydrochloride solution was injected into the reaction mixture after the finish of CL reaction of alkaline N‐Chlorosuccinimide (NCS) and dichlorofluorescein. Based on this phenomenon, a simple, sensitive and fast flow injection PCL method was established for the determination of loperamide hydrochloride. The possible mechanism for the PCL reaction was discussed via the investigation of the CL kinetic characteristics, the CL spectra, the fluorescence spectra. The PCL intensity responded linearly to the concentration of loperamide hydrochloride in the range 8.0×10?10 to 6.0×10?7 g · ml?1 with a linear correlation of 0.9995. The detection limit was 4×10?10 g · ml?1. The relative standard deviation was 2.4% for 4.0×10?8 g · ml?1 loperamide hydrochloride (n=11). This method has been applied to the determination of loperamide hydrochloride in human plasma and pharmaceutical samples with satisfactory results.  相似文献   

11.
Fenfluramine-imprinted polymer was prepared by self assembly with acrylic amide as functional monomer and ethylene glycol dimethacrylate as crosslinker. The binding characteristics of the imprinted polymer to fenfluramine were evaluated by equilibrium binding experiments and the morphology was studied by SEM. Taking the imprinted polymer as recognition material, using the new 3-p-nitrylphenyl-5-(4′-methyl-2′-sulfonophenylazo)rhodanine (M4NRASP) synthesized by the authors as chemiluminescence reagent, a new highly selective flow injection chemiluminescence sensor for trace fenfluramine with good sensitivity was established which utilized the chemiluminescence reaction between fenfluramine, M4NRASP, and potassium permanganate in hydrochloric acid. The traditional flow-through cell was replaced with a polymethyl methacrylate module, with Y-shaped flow path, through which the above three reactants were injected simultaneously. Under optimum conditions the relative chemiluminescence intensity shows a linear relationship with the concentration of fenfluramine over the range of 5×10–7 to 8×10–6 g/mL with a lower detection limit of 3.4×10–8 g/mL. The relative standard deviation for the determination of 1.0×10–6 g/mL fenfluramine solution was 2.4% (n = 11). This proposed sensor could be satisfactorily applied to the determination of fenfluramine in weight-reducing capsules.  相似文献   

12.
聂菲  吕九如 《化学学报》2007,65(20):2299-2302
发现钙黄绿素可以吸收铁氰化钾氧化酮替芬反应的化学能而产生化学发光, 以钙黄绿素为化学发光试剂, 构建了铁氰化钾-酮替芬-钙黄绿素化学发光体系, 利用此体系建立了测定酮替芬的化学发光分析新方法, 方法的线性范围为2.0×10-8~6.0×10-6 g•mL-1, 检出限为8×10-9 g•mL-1, 对浓度为5.0×10-7 g•mL-1酮替芬溶液进行11次平行测定的相对标准偏差(RSD)为2.1%. 此法已用于药品中酮替芬含量的测定, 结果与药典测定结果一致. 对化学发光反应的机理也进行了初步的探讨.  相似文献   

13.
《Analytical letters》2012,45(14):2037-2052
A rapid and simple flow injection (FI) method is reported for the determination of vitamin A (retinol) based on its strong enhancing effect on the Ce(IV)–Na2SO3 chemiluminescence (CL) reaction in an acidic solution. The effect of key chemical and physical parameters (i.e., reagent concentrations, flow rate, and sample volume) was optimized and potential interferences examined. Under the selected experimental conditions, a linear calibration was obtained between the CL intensity and vitamin A concentration in the range 0.1–8.0 µg mL?1 (r 2  = 0.9986, n = 8). The limit of detection (3 s x blank) was 0.01 µg mL?1 retinol (n = 6) and the relative standard deviation (RSD) for 0.25 µg mL?1 retinol was 2.3% (n = 10) with a sampling rate of 180 h?1. The method was successfully applied to infant milk-based formulas and pharmaceutical formulations and the results were not significantly different at 95% confidence interval with those obtained by using a spectrophotometric reference method. The possible CL mechanism is also discussed briefly supporting with UV-visible, fluorescence, and CL spectra.  相似文献   

14.
《Analytical letters》2012,45(8):1375-1386
Abstract

A novel chemiluminescence method for the quantitative assay of the organophosphorus pesticide chlorpyrifos in vegetable samples is presented. The determination is based on the reaction of chlorpyrifos with luminol-H2O2 in alkaline medium with sodium chloride being enhancer. Under the optimum conditions, the increased CL intensity was proportional with the concentration of chlorpyrifos in the range of 1.0 × 10?8 g · ml?1 ? 1.0 × 10?6 g · ml?1 and the detection limit was 3.5 × 10?9 g · ml?1 (3σ). The relative standard is less than 3.9% for 5.0 × 10?7g · ml?1 chlorpyrifos (n = 7). This method has been successfully applied to the determination of chlorpyrifos residue in vegetable sample. Further study was focused on the mechanism of chlorpyrifos and the possible mechanism was proposed.  相似文献   

15.
The anti-schizophrenic drug risperidone (RSP) exerts an inhibitory effect on the chemiluminescence (CL) of the luminol-lysozyme system. This finding forms the basis for a sensitive flow injection method for its determination at picogram levels. RSP binds to Trp62 in the lysozyme, and this leads to a conformational change upon which the CL of the system is quenched. The decrease in CL is proportional to the logarithm of the concentration of RSP, and the calibration graph is linear in the range from 0.1 pg?mL?1 to 1.0 ng?mL?1, with relative standard deviations of <5.0%, and a detection limit of 0.05 pg?mL?1 (3σ). At a flow rate of 2.0 mL?min?1, the whole process including sampling and washing is completed within 20 s. The method was successfully applied to monitoring RSP in human urine after incorporation of 2 mg of RSP, with a total excretion of 16.6% within 8.5 h.
Figure
The reaction of lysozyme with risperidone using luminol as luminescence reagent by the luminol-lysozyme FI-CL system and its application.  相似文献   

16.
《Analytical letters》2012,45(14):2234-2245
A novel chemiluminescence (CL) method is developed for determination of ofloxacin and levofloxacin with Ag(III) complex in H2SO4 solution medium. The CL intensity is proportional to drug concentration in a wider range with a correlation coefficient of 0.999. The limit of detection (s/n = 3) for ofloxacin and levofloxacin was 5.3 × 10?9 g ml?1 and 8.3 × 10?9 g ml?1, respectively, and their recoveries from urine and serum samples were in the range of 90.1–112% with the RSDs of 1.0–2.8%. The proposed method was applied for analysis of real samples with satisfactory result. The possible CL mechanism was discussed.  相似文献   

17.
This work presents a new chemiluminescent (CL) probe array assay. The new type CL probe array is based on enzyme mimics of Co3O4–SiO2 mesoporous nanocomposite material, which not only have an excellent catalytic effect on the luminol–H2O2 CL reaction in an alkaline medium but also can be used for the immobilization of enzymes. The linear range of the lactose concentration is 3.0?×?10?7 to 1.0?×?10?5 g mL?1 and the detection limit is 6.9?×?10?8 g mL?1. β-Galactosidase and glucose oxidase were selected as a model for enzyme assays to demonstrate the applicability of Co3O4–SiO2 mesoporous nanocomposite material in multienzyme immobilization. The novel bifunctional CL probe array has been successfully applied to the determination of lactose in milk.  相似文献   

18.
《Analytical letters》2012,45(7):1279-1289
Abstract

Based on the fact that nonionic surfactant polyethylene glycol-400 (PEG-400) catalyzed the chemiluminescence of luminol-H2O2 system, a novel and simple chemiluminescence method has been developed for the determination of PEG-400. Under the optimal conditions, the standard curve was Y = 198835X–2091.8, where the correlation coefficient (R) was 0.9999. The detection limit was 4 × 10?5 g·ml?1 PEG-400 and the linear range was 1.0 × 10?4–4.0 × 10?2g·ml?1. The relative standard deviation was 3.2% at 2.0 × 10?3 g·ml?1 PEG-400 (n = 7). This method has been applied to the determination of PEG-400 in cosmetic samples with satisfactory results. Furthermore, the dynamics characteristic curve of PEG-400 in luminol-H2O2 system was compared to typical metallic ion and other surfactants. Moreover, the mechanism of the luminol-H2O2-PEG-400 chemiluminescence system was studied, assisted by fluorescence spectra and UV spectra.  相似文献   

19.
Jiangman Liu 《Analytical letters》2013,46(11):1804-1815
A sensitive method for the determination of total chromium in real samples by flow injection–chemiluminescence (FI–CL) analysis was proposed. It was found that the CL intensity from luminol–lysozyme reaction could be markedly quenched, and the decrease of CL intensity was linear with the logarithm of Cr(III) concentrations over the range of 5.0 to 4000 pg mL?1 with a detection limit of 2.0 pg mL?1 (3σ) and relative standard deviations (RSDs) of 3.0, 2.6, and 2.0% for 10, 100, and 1000 pg mL?1 Cr(III) (n = 7), respectively. At a flow rate of 2.0 mL min?1, the whole process including sampling and washing could be accomplished within 36 s. The proposed CL method was successfully applied to the determination of total chromium in pharmaceutical capsules, a dietary supplement, and spiked human serum samples, with recoveries from 92.2 to 108.4% and RSDs of less than 4.0%. Using the homemade FI–CL model, the binding constant (K = 4.38 × 106 L mol?1) and the binding sites (n ≈ 1) of Cr(III) to lysozyme were given.  相似文献   

20.
《Analytical letters》2012,45(1-3):137-145
A sensitive flow injection chemiluminescence (CL) method is proposed for the determination of bovine serum albumin (BSA) using Copper(II)-Alizarin Red S (ARS) complex as an efficient chemiluminescent probe. The detection is based on the binding of the copper(II)-ARS complex to proteins and the catalytic activity of copper(II)-ARS in the luminol-H2O2 CL system. Under the selected conditions, the CL intensity is linear with the concentration of BSA in the range of 5.0 × 10?11 to 1.0 × 10?9 mol · L?1. The detection limit was 2.0 × 10?11 mol · L?1. The method is successfully applied to the determination of protein in urine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号