首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 921 毫秒
1.
A hanging copper amalgam drop electrode (HCADE) is used for the determination of traces of iodide by cathodic stripping voltammetry. The cathodic stripping peak of copper(I) iodide from the HCADE is better defined than that of mercury(I) iodide from a hanging mercury drop electrode. Optimum conditions and interferences are reported. With a 3-min deposition time at ?0.1 V vs. SCE, the calibration plot is linear up to 2 × 10?6 mol dm?3 iodide. The detection limit for iodide with the HCADE under voltammetric conditions is 4 × 10?8 mol dm?3; this is lowered to 8 × 10?9 mol dm?3 by using the differential pulse stripping technique.  相似文献   

2.
《Analytical letters》2012,45(13):2569-2579
Abstract

A method for determination of L‐dopa by the adsorption stripping voltammetry (ASV) using a multiwalled carbon nanotubes (MWNTs)–Nafion modified glassy carbon electrode (GMGCE) was proposed. This chemically modified electrode (CME) shows a better stability. A sensitive oxidation peak was observed and the anodic peak potential is ca. 0.374V (vs. SCE). The influences of various experimental parameters on the current peak were completely studied. Under the optimized condition, the method has been applied to the determination of L‐dopa in samples. There is a good linear relationship between the peak current (ip) and L‐dopa concentration in the range of 3.5×10?7~1.5×10?5 mol/L, with the limit of detection 5.0×10?8 mol/L.  相似文献   

3.
《Analytical letters》2012,45(6):1193-1196
Abstract

The 2.5th order differential polarographic reduction behavior of malonaldehyde (MLD) was studied. A sensitive measurement method of the determination of MLD for biological samples was given by using differential voltammetry with a static mercury drop electrode at a scanning speed of 80mV/s in a solution of 0.1mol/L NH4Cl. The linear response range of current(e″) against the concentration of MLD was 1.0×10?6 to 1.0×10?3 mol L and the detection limit was 1.0 × 10?7mol/L. The contents of MLD in the sample of cardiac myocytes was determined rapidly and simply by means of the method.  相似文献   

4.
《Analytical letters》2012,45(17):3147-3160
Abstract

The multiwalled carbon nanotube–nickel hydroxide composite film used to modify glassy carbon electrode was prepared and confirmed by transmission electron microscopy and cyclic voltammetry. The process and mechanism of film formation were discussed in detail. The electrode modified with the composite film exhibited good catalytic activity toward electrochemical oxidation of hydrogen peroxide in 0.1 mol/L sodium hydroxide solution. Various factors affecting the electrocatalytic activity of nickel hydroxide film were investigated. The anodic peak current increased with the increased concentration of hydrogen peroxide. The linear range for the determination of hydrogen peroxide was from 1.5 × 10?6 mol/L to 2.5 × 10?3 mol/L with the detection limit 6.1 × 10?7 mol/L (S/N = 3). And the proposed method was applied to the determination of hydrogen peroxide in disinfector with higher sensitivity and lower detection limit.  相似文献   

5.
《Analytical letters》2012,45(13):2045-2055
Abstract

A new method for determination of trace indium is proposed by the adsorption stripping voltammetry (ASV) using a Nafion‐modified glassy carbon electrode (NMGCE). This chemically modified electrode (CME) shows a better stability. A sensitive oxidation peak was observed, and the anodic peak potential is ca. ?0.548 V (vs. SCE). The influences of various experimental parameters on the current peak were completely studied. Under the optimized condition, the method has been applied to the determination of indium in water samples. There is a good linear relationship between the peak current (ip) and indium(III) concentration in the range of 1.0×10?9–1.0×10?7 mol/l, and the limit of detection is 7.5×10?10 mol/l.  相似文献   

6.
Electrochemical behavior of dopamine (DA) was investigated at the gold nanoparticles self‐assembled glassy carbon electrode (GNP/LC/GCE), which was fabricated by self‐assembling gold nanoparticles on the surface of L ‐cysteine (LC) modified glassy carbon electrode (GCE) via successive cyclic voltammetry (CV). A pair of well‐defined redox peaks of DA on the GNP/LC/GCE was obtained at Epa=0.197 V and Epc=0.146 V, respectively. And the peak separation between DA and AA is about 0.2 V, which is enough for simultaneous determination of DA and AA. The peak currents of DA and AA were proportional with their concentrations in the range of 6.0×10?8–8.5×10?5 mol L?1 and 1.0×10?6–2.5×10?3 mol L?1, with the detection limit of 2.0×10?8 mol L?1 and 3.0×10?7 mol L?1 (S/N=3), respectively. The modified electrode exhibits an excellent reproducibility, sensibility and stability for simultaneous determination of DA and AA in human serum with satisfactory result.  相似文献   

7.
An ionic liquid N‐hexylpyridinium hexafluorophosphate (HPPF6) modified carbon paste electrode was fabricated for the sensitive voltammetric determination of adenosine in this paper. Carbon ionic liquid electrode (CILE) was prepared by mixing graphite powder and HPPF6 together and the CILE was characterized by scanning electron microscopy (SEM) and electrochemical methods. The electrochemical behaviors of adenosine on the CILE were studied carefully. Compared with the traditional carbon paste electrode (CPE), a small negative shift of the oxidation peak potential appeared with greatly increase of the oxidation peak current, which indicated the presence of ionic liquid in the carbon paste not only as the binder but also as the modifier and promoter. Under the optimal conditions the oxidation peak current increased with the adenosine concentration in the range from 1.0×10?6 mol/L to 1.4×10?4 mol/L with the detection limit of 9.1×10?7 mol/L (S/N=3) by differential pulse voltammetry. The proposed method was applied to the human urine samples detection with satisfactory results.  相似文献   

8.
《Analytical letters》2012,45(18):3046-3057
Abstract

Nano-MnO2/chitosan composite film modified glassy carbon electrode (MnO2/CHIT/GCE) was fabricated and a DNA probe was immobilized on the electrode surface. The immobilization and hybridization events of DNA were characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The EIS was applied to the label-free detection of the target DNA. The human immunodeficiency virus (HIV) gene fragment was successfully detected by this DNA electrochemical sensor. The dynamic detection range was from 2.0 × 10?11 to 2.0 × 10?6 mol/L, with a detection limit of 1.0 × 10?12 mol/L.  相似文献   

9.
《Analytical letters》2012,45(8):1411-1423
Abstract

The electrochemical behaviour of the bilirubin in many kinds of supporting electrolytes on a glassy carbon electrode (GCE) and a hanging mercury drop electrode (HMDE) was investigated by means of anodic or cathodic differential pulse voltammetry. The influences of different methods of pre-treatment of the glassy carbon electrode was also discussed. In Na2B4.O7-KH2PO4 buffer solution, the linear range was 2×10?9-1×10?9 mol/l and the detection limit was 3.3×10?9 mol/l by anodic differential pulse voltammetry at GCE. A linear relationship holds between the peak current and the concentration of bilirubin in a concentration range of 1×10?9-4×10?7 mol/l with good precision and accuracy, and the limit of detection was 2×10?10 mol/l, when cathodic differential pulse adsorption voltammetry at HMDE was used.  相似文献   

10.
A new method for the determination of trace copper was described. A multiwalled carbon nanotube modified carbon paste electrode was prepared and the adsorptive voltammetric behavior of copper‐alizarin red S (ARS) complex at the modified electrode was investigated. By use of the second‐order derivative linear sweep voltammetry, it was found that in 0.04 mol/L acetate buffer solution (pH 4.2) containing 4×10?6 mol/L ARS, when accumulation potential is 0 mV, accumulation time is 60 s and scan rate is 100 mV/s, the complex can be adsorbed on the surface of the electrode, yielding one sensitive reduction peak at ?172 mV (vs. SCE). The peak current of the complex is proportional to the concentration of Cu(II) in the range of 2.0×10?11–4.0×10?7 mol L?1 with a detection limit (S/N=3) of 8.0×10?12 mol/L (4 min accumulation). The proposed method was successfully applied to the determination of copper in biological samples with satisfactory results, the recoveries were found to be 96%–102%.  相似文献   

11.
A simpe electrochemical sensor for detection of cholic acid (CA) was designed by modifying phosphomolybdate (PMo12) doped polypyrrole (PPy) film on glassy carbon electrode (PMo12‐PPy/GCE). The electrochemical behavior of CA on PMo12‐PPy/GCE was investigated by cyclic voltammetry and 0.5 order differential voltammetry. The results indicated that CA had high inhibitory activity toward the peak currents of PMo12‐PPy/GCE. The reduction peak currents were linearly related to the logarithmic value of the concentration of CA from 1.0×10?7 to 1.0×10?3 mol/L with a low detection limit of 1.0×10?8 mol/L. The developed sensor exhibited excellent sensitivity, selectivity and stability for detection of CA, and it could be successfully applied to detect the level of CA in the urine samples. Moreover, the response mechanism of CA on the PMo12‐PPy/GCE was discussed in detail.  相似文献   

12.
《Analytical letters》2012,45(6):1165-1173
Abstract

The polarographic behavior of the complex of iron–4– (2–pyridylazo) resorcin(PAR) was studied. In HAc– NaAc– EDTA buffer solution, the complex can be adsorped on a hanging mercury drop electrode giving a sensitive adsorptive complex reduction peak with a peak potential at -0.36V(vs. SCE). Optimum experimental conditions were found by the use of 0.08mol/L HAc, 0.06mol/L NaAc, 5.0 × 10?3mol/L EDTA and 1.0 × 10?5mol/L PAR. With preconcentration for 60s, the derivative peak height of the complex compound is linearly proportional to the concentration for Fe in the range from 1.0 × 10?9mol/L to 1.0 × 10?7mol/L. For a 2–min pre–concentration time, the detection limit found was 2.0 × 10?10mol/L. This method has high sensitivity and selectivity. It has been applied to the determination of trace iron in food and water samples without any pre–separation step.  相似文献   

13.
《Analytical letters》2012,45(6):1097-1107
Abstract

Captopril, 1-[(2S)-3-mercapto-2-methyl-1-oxopropyl]-L-Proline, can be deposited onto a silver electrode by a covalent bonding method to give a long-lived and stable chemically modified electrode(CME). Since the CME is prepared with a reaction between captopril and the substrate silver, the CME being prepared by this method is very stable. Furthermore, Hemoglobin(Hb) exhibits excellent voltammetric response at the modified electrode. Differential pulse voltammetric(DPV) measurements of the protein with this CME reveal the existence of a linear relationship between the anodic peak current and the concentration of Hb in the range of 2×10?6 ~ 5×10?5 mol/L. The detection limit is 8×10?7 mol/L and the relative standard deviation of results is 5% for 6 successive determinations at 2×10-5 mol/L. The determination of Hb for a real example is carried out.  相似文献   

14.
《Electroanalysis》2006,18(3):291-297
Selected from a series of structurally related heteroaromatic thiols, a newly synthesized reagent 2‐amino‐5‐mercapto‐[1,3,4] triazole (MATZ) was used to fabricate self‐assembled monolayers (SAMs) on gold electrode for the first time. The MATZ/Au SAMs was characterized by electrochemical methods and scanning electronic microscopy (SEM). In 0.04 mol/L Britton–Robinson buffer solution (pH 5), the electrochemical behavior of dopamine showed a quasireversible process at the MATZ/Au SAMs with an electrode kinetic constant 0.1049 cm/s. However, the electrochemical reaction of uric acid at the SAMs electrode showed an irreversible oxidation process, the charge‐transfer kinetics of uric acid was promoted by the SAMs. By Osteryoung square‐wave voltammetry (OSWV), the simultaneous determination of dopamine and uric acid can be accomplished with an oxidation peak separation of 0.24 V, the peak current of dopamine and uric acid were linearly to its concentration in the range of 2.5×10?6–5.0×10?4 mol/L for dopamine and 1×10?6–1×10?4 mol/L for uric acid with a detection limit of 8.0×10?7 mol/L for dopamine and 7.0×10?7 mol/L for uric acid. The MATZ/Au SAMs electrode was used to detect the content of uric acid in real urine and serum sample with satisfactory results.  相似文献   

15.
《Analytical letters》2012,45(10):2203-2215
Abstract

A new system of polarographic adsorptive wave for determining trace scandium was proposed. In 0.2 mol/L NH4OAc, the Sc(III)- ACBK [1,8- dihydroxy- 2- (2- hydroxy- 5- sulfo- 1- phenylazo)- 3,6- disulfo- naphthalene, called acid chrome blue K] complex emerged a sensitive adsorptive complex wave(Ep′ = -0.67V). The molar ratio of Sc(III) to ACBK in the complex was established as 1: 2 and the apparent stability constant β2 = 2.7 × 1015. But for Y(III), the molar ratio was 1: 1 and β = 1.5 × 105. Because of the particularity of Sc complex, the sensitivity and the selectivity of determination Sc are much better than that of other rare earth ions. The detection limit is 1.1 × 10?7 mol/L for oscillopolarography and 2.0 × 10?8 mol/L for adsorptive stripping voltammetry.  相似文献   

16.
《Analytical letters》2012,45(4):582-592
Abstract

A new type of gold nanoparticles–attached indium tin oxide electrode was made. By SEM and EDS, the as‐prepared gold nanoparticles–modified ITO electrode was characterized. This modified electrode has been used for the determination of pirarubicin (THP) in urine by cyclic voltammetry. Compared to a bare ITO electrode, the modified electrode exhibited a marked enhancement in the current response. Liner calibration curves are obtained in the range 5×10?9mol/L~1.5×10?6 mol/L with a detection limit of 1×10?9 mol/L. The percentage of the recoveries ranged from 99.3% to 106.3%. The practical analytic utility of the method is illustrated by quantitative determination of THP in urine.  相似文献   

17.
《Analytical letters》2012,45(11):2259-2269
ABSTRACT

A new method for the determination of ethanol is proposed based on the catalytic current of sulfate radical anion SO4 ?. In 0.1 mol/L KH2PO4–Na2HPO4 buffer (pH5.6±0.1)–1.6×10?2 mol/L K2S2O8 solution, the first order derivative peak current is proportional to ethanol concentration in the range of 1×10?4~9×10?4 (r = 0.9998). The limit of detection is 6×10?5 mol/L. The proposed method is applied to determine ethanol directly content in ardent spirits. The fundamental principle of the proposed method is that ethanol is oxidized by sulfate radical anion SO4 ? electrogenerated on the electrode surface to ethanol α-radical, and the reduction of the ethanol α-radical produces a polarographic reduction wave.  相似文献   

18.
In this paper, nichrome was adopted as a substrate, to fabricate the pre‐anodized inlaying ultrathin carbon paste electrode (PAIUCPE). The electrochemical behaviors and diffusion mechanisms of three dihydroxybenzene isomers at the electrode were carefully investigated. The effect of pH on oxidation peak current was also detailedly explained. The results were shown that oxidation peak current not only related to the reaction of electroactive materials at the working electrode, but also depended on the reaction variable of reduction at the auxiliary electrode. The oxidation peaks of hydroquinone (HQ), catechol (CC) and resorcinol (RC) located at 0.181 V, 0.288 V and 0.736 V. For CC, RC and HQ, the oxidation peak currents were linear to the concentrations at the range of 5.0 × 10?6~5.0 × 10?4 mol/L, 3.0 × 10?6~5.0 × 10?4 mol/L and 4.0 × 10?6~4.0 × 10?4 mol/L with the detection limits of 2.0 × 10?7 mol/L, 1.2 × 10?7 mol/L and 1.2 × 10?7 mol/L, respectively. The proposed method was successfully applied in the simultaneous determination of dihydroxybenzene isomers in artificial sewage samples with satisfactory results.  相似文献   

19.
A novel ion implantation sensor (DNA/COOH/ITO) based on DNA immobilization in COOH/ITO probe was manufactured for the first time. The surface morphologies of the electrodes were characterized by X‐ray photoelectron spectroscopy (XPS), field‐emission‐scanning electron microscopy (FSEM) and electrochemical methods. In a 0.5 mol/L PBS solution, a sensitive oxidation peak of DNA on the COOH/ITO electrode was obtained by voltammetry. The electrochemical behavior of DNA was studied. And the oxidative peak potential of DNA was +0.400 V (vs. Ag/AgCl). Its peak current was proportional to the concentration of DNA over the range of 1.0×10?8?1.0×10?6 mol/L with a detection limit of 5.0×10?9 mol/L (about 0.5 ng/mL). This sensor was applied to the direct detection of DNA samples.  相似文献   

20.
《Electroanalysis》2006,18(2):158-162
Optimum conditions have been found for voltammetric determination of mutagenic 5‐aminoquinoline, 6‐aminoquinoline and 3‐aminoquinoline by differential pulse voltammetry and adsorptive stripping differential pulse voltammetry on carbon paste electrode. The lowest limits of determination were found for adsorptive stripping differential pulse voltammetry in 0.1 mol dm?3 H3PO4 (5×10?7 mol dm?3 , 1×10?7 mol dm?3, and 1×10?7 mol dm?3 for 5‐aminoquinoline, 6‐aminoquinoline and 3‐aminoquinoline, respectively). The possibility to determine mixtures of 8‐aminoquinoline with 3‐aminoquinoline or 5‐aminoquinoline or 6‐aminoquinoline, and mixtures of 5‐aminoquinoline with 3‐aminoquinoline or 6‐aminoquinoline by differential pulse voltammetry was verified. Binary mixtures of 8‐aminoquinoline with 3‐aminoquinoline or 6‐aminoquinoline, and of 3‐aminoquinoline with 5‐aminoquinoline could be successfully analyzed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号