 共查询到20条相似文献,搜索用时 31 毫秒
1.
High-performance liquid chromatographic assay procedures have been developed for naproxen, ibuprofen and diclofenac in human plasma and synovial fluid samples. A single liquid-liquid extraction procedure was used to isolate each compound from acidified biological matrix prior to the quantitative analysis. A Spherisorb ODS column (12.5 cm x 4.6 mm I.D.) was used for all the chromatography. Naproxen was eluted with a mobile phase of methanol-S?rensen's buffer at pH 7 (37:63, v/v). Ibuprofen and diclofenac were eluted using mobile phases of methanol-water at pH 3.3 (65:35, v/v and 63:37, v/v, respectively). Diphenylacetic acid was used as the internal standard for the assay of naproxen and flurbiprofen was used in the analysis of ibuprofen and diclofenac. Inter- and intra-day coefficients of variation were less than 7%. The assays were used in clinical studies of the three drugs in osteo- and rheumatoid arthritis patients.  相似文献   

2.
《Analytical letters》2012,45(9):555-562
Abstract

A method for the determination of gold in biological materials such as serum, urine, synovial fluid and tissues was investigated. After the dry ashing of the samples, gold was extracted from 6 M HCL into MIBK. The amount of gold was determined directly in the organic phase by the atomic absorption spectrometry. The range of the working curve was from 0.1 to 5.0 μg and the accuracy and recovery of the present method were satisfactory for practical purposes.  相似文献   

3.
Zhou  Jing  Zhang  Yingxue  Xu  Baiqiu  Zhang  Xu  Cui  Shufen 《Chromatographia》2014,77(17):1213-1221

In this study, a liquid-phase solvent bar micro-extraction technique was used to investigate both the extraction and back-extraction processes of the target analyte. A novel concentration curve method and a classic time curve method, used under the same experimental conditions, verified the symmetry between the extraction process (target analyte moves from sample matrix to the organic solvent-based extraction phase) and the back-extraction process (target analyte moves from organic solvent to the sample matrix), providing the basis to use the target analyte in the back-extraction process to calibrate its extraction process. A quantitative calibration can be achieved using back extraction on the target analyte from the blank sample matrix in the organic solvent. Information from the process of back extraction of the target analyte, such as the time constant a, can be directly used to calculate the initial concentration of the target analyte in the sample matrix. This new kinetic calibration method employs a liquid-phase solvent bar micro-extraction technique combined with high-performance liquid chromatography with a diode array detector (HPLC-DAD) and was successfully used to analyze three local anesthetics in biological samples; it extends the application of the kinetic calibration to HPLC-DAD and establishes a novel, simple and accurate method to determine the concentration of the free drug in biological samples and its protein-binding ratio.

  相似文献   

4.
Abstract

A high performance liquid chromatographic assay for quantitating amodiaquine (A) in tablets, urine, plasma, bile and saliva is described. The method involved acid extraction of the drug from tablets and chloroform extraction of its base from the biological fluids after alkalinization with ammonia. Quinidine was used as the internal standard. A μ-Bondapak phenyl column was used for separation together with a mobile phase made of methanol, water and glacial acetic acid (pH 2.3). Good chromatograms with efficient separation of drug and internal standard peaks were observed. Retention times of 5.2 and 7.1 min. were obtained for the drug and the internal standard respectively. Correlation between areas under the curve and drug concentration was high. The mean percentage recovery of A from tablets was 102.03%, while from the biological fluids, it ranged from 85.2 to 104.61%. Urine and saliva obtained from volunteers and bile obtained from animals administering amodiaquine showed chromatograms similar to those obtained for blank samples spiked with A. Interference from table't excipients of biological fluids was undetectable or negligible. The method was found to be precise and simple.  相似文献   

5.
《Analytical letters》2012,45(21-22):1649-1663
Abstract

A rapid and sensitive high-performance liquid chromatographic method for the determination of diclofenac sodium in plasma has been developed. The method is specific and free of interference from metabolites and common anti-inflammatory agents. The UV detector (215 nm) response was linear over a range of 5-1000 ng/ml. Day-to-day and within-day calibration curves were reproducible. The method was validated by analysis of spiked human plasma samples, partly in a blind fashion. The accuracy and precision of the method are satisfactory over the range of 5-1000 ng/ml. The method was cross-checked with the GC method. Results show a correlation coefficient of 0.983 and a slope of 1.04. The method is suitable for the routine analysis of large numbers of plasma samples usually obtained in bioavailability and pharmacokinetic studies.  相似文献   

6.
Determination of Se in biological materials was attempted by microwave-induced plasma mass spectrometry (MIP-MS). (1) Serum samples were available after 10 times dilution with 0.5% nitric acid solution containing 0.1% Triton X-100. When oxygen gas was inserted into the plasma gas (nitrogen) in order to improve the combustion, the sensitivity was reduced to 45%. The detection limit of this method was 0.5 ng/mL. (2) Standard reference materials on commercial base were used to evaluate the accuracy of the Se determination by MIP-MS after microwave digestion. In samples like bovine liver and human hair with Se concentrations of more than 0.7 μg/g, the standard curve method after internal standard (IS) correction was acceptable. This procedure was unsuitable for samples with low Se concentrations such as milk powder (certified value of Se 0.11 μg/g), or plant leaf samples. (3) Instead of IS correction, the peak height of the spectrum was used for calculations from the matrix matched calibration curve. The results of all materials were close to the certified values, even at 25 ng/g. The detection limit of the MIP-MS with microwave digestion and IS correction was 0.05 ng/mL in standard solutions. The detection limit of the peak height method was 0.1 ng/mL and was estimated to be < 20 ng/g in plant materials. Received: 25 September 1998 / Revised: 15 February 1999 / Accepted: 18 February 1999  相似文献   

7.
《Analytical letters》2012,45(8):995-1001
Abstract

A simple near-IR transmission spectroscopy method for the determination of percent carbon coverage in trimethylsilylated silicas has been developed. The alkylated silica is slurried in carbon tetrachloride, a solvent with a similar refractive index to silica, to reduce light scattering. Percent carbon is then determined by measuring either the peak height or peak area ratio of the peak at 1180 nm (due to the second overtone of the C-H stretch) to the peak at 1385 nm (due to the overtone of the SiO-H stretch). Comparison with results from elemental analysis permits construction of a correlation curve that can then be used to determine % carbon in unknown samples.  相似文献   

8.
In this study, a liquid-phase solvent bar micro-extraction technique was used to investigate both the extraction and back-extraction processes of the target analyte. A novel concentration curve method and a classic time curve method, used under the same experimental conditions, verified the symmetry between the extraction process (target analyte moves from sample matrix to the organic solvent-based extraction phase) and the back-extraction process (target analyte moves from organic solvent to the sample matrix), providing the basis to use the target analyte in the back-extraction process to calibrate its extraction process. A quantitative calibration can be achieved using back extraction on the target analyte from the blank sample matrix in the organic solvent. Information from the process of back extraction of the target analyte, such as the time constant a, can be directly used to calculate the initial concentration of the target analyte in the sample matrix. This new kinetic calibration method employs a liquid-phase solvent bar micro-extraction technique combined with high-performance liquid chromatography with a diode array detector (HPLC-DAD) and was successfully used to analyze three local anesthetics in biological samples; it extends the application of the kinetic calibration to HPLC-DAD and establishes a novel, simple and accurate method to determine the concentration of the free drug in biological samples and its protein-binding ratio.  相似文献   

9.
Determination of Se in biological materials was attempted by microwave-induced plasma mass spectrometry (MIP-MS). (1) Serum samples were available after 10 times dilution with 0.5% nitric acid solution containing 0.1% Triton X-100. When oxygen gas was inserted into the plasma gas (nitrogen) in order to improve the combustion, the sensitivity was reduced to 45%. The detection limit of this method was 0.5 ng/mL. (2) Standard reference materials on commercial base were used to evaluate the accuracy of the Se determination by MIP-MS after microwave digestion. In samples like bovine liver and human hair with Se concentrations of more than 0.7 μg/g, the standard curve method after internal standard (IS) correction was acceptable. This procedure was unsuitable for samples with low Se concentrations such as milk powder (certified value of Se 0.11 μg/g), or plant leaf samples. (3) Instead of IS correction, the peak height of the spectrum was used for calculations from the matrix matched calibration curve. The results of all materials were close to the certified values, even at 25 ng/g. The detection limit of the MIP-MS with microwave digestion and IS correction was 0.05 ng/mL in standard solutions. The detection limit of the peak height method was 0.1 ng/mL and was estimated to be < 20 ng/g in plant materials.  相似文献   

10.
《Analytical letters》2012,45(11):2009-2021
Abstract

The anticancer agent CAI was quantitated from human plasma using a C-18 column with a mobile phase consisting of acetonitrile and water (each containing 0.01M ammonium acetate) pumped over a gradient at a flow rate of 1.0 mL min. The detection of CAI and the internal standard, harmine, was accomplished using a photodiode-array detector set at 264 and 323 nm, respectively. The chromatographic run time was 17.5 minutes. The plasma samples were prepared for HPLC analysis using a C-18 solid phase extraction procedure. Two calibration curves were prepared. and the assay was shown to be linear in the concentration range of 0.02 to 0.5 μg/mL for the low curve and 0.25 to 10.0 μg/mL for the high curve, with average correlation coefficients of 0.9933 and 0.9938, respectively. Intra-assay and inter-assay imprecisions were less than 10.0% with an error of accuracy of less than 11.0%. The assay was reproducible with the sensitivity needed for the prediction of CAI levels in the plasma of cancer patients.  相似文献   

11.
In a recent collaborative study intended to extend the variety of reference materials certified for iodine, three mineralization methods were developed to quantify the total iodine content of biological and nutritional materials by inductively coupled plasma mass spectrometry (ICP-MS). A mixture of water-soluble tertiary amines was used as the matrix solution for two oxygen combustion methods and for a simple extraction at room temperature. Calibrations with matrix-matched standards, internal calibration, and isotope dilution with 129I were used. Good agreement between neutron activation analysis (NAA) and the two combustion methods was observed except for < 0.1 mg kg–1 iodine concentrations. The amine extraction method gave the most reliable results for the mixed diet, milk powder, and infant formula samples but low recoveries for other biological materials owing to an incomplete extraction and solubilization of iodine. The NAA method, with its freedom from reagent blank, is a useful technique for the independent determination of iodine in biological, environmental and food matrices, especially for verification of iodine results obtained by ICP-MS.  相似文献   

12.
In this study a new RP‐HPLC with photo‐diode array detection method for the determination of ibuprofen ((RS)‐2‐(4‐isobutylphenyl)propionic acid) in human plasma samples was developed. Samples were prepared by SPE and analyzed by an isocratic elution mode over a C18 column using 80% methanol. A novel sample pretreatment method, based on the addition of ionic liquids possessing chaotropic ions to small human plasma sample (100 μL), was elaborated. 1‐Butyl‐3‐methylimidazolium chloride and 1‐butyl‐3‐methylimidazolium tetrafluoroborate (BMIM BF4) were tested from the point of view of extraction yield. Quantification was based on calibration curve applying diclofenac as the internal standard. Owing to dilution of plasma sample by 2 mM aqueous solution of BMIM BF4 before SPE, appropriate sample purification and extraction yields higher than 95% with precision lower than 2% can be achieved. Linear coefficients of correlation (r2) were >0.99 in the range of 0.3–5 μg/mL ibuprofen concentration in plasma. The limit of quantification was 65 ng/mL and the detection limit for ibuprofen was 19.5 ng/mL.  相似文献   

13.
A rapid, accurate and precise HPLC-ESI-MS method for the determination of rat plasma uridine concentrations was developed and is described here. Sample preparation involves methanol precipitation of plasma proteins in a 96-well Captiva protein precipitation filter plate. A clear extract is drawn through the filter plate with vacuum, followed by evaporation of the extract and subsequent reconstitution prior to chromatography on a reversed-phase column with an aqueous mobile phase [0.1% (v/v) glacial acetic acid]. Detection was accomplished by positive-ion electrospray ionization mass spectrometry. A calibration curve ranging in concentration from 0.78 to 25 microM was constructed by best-fit, 1/x weighting linear regression analysis of the calibration standard concentrations vs peak height ratios of analyte with internal standard. The correlation coefficient was >0.995. The overall assay accuracy as shown by the back-calculated concentrations of the calibration curve ranged from 96.6 to 103% with RSD ranging from 4.5 to 20%. While this assay method was developed for the determination of uridine in rat plasma, it could be readily adapted for determination of uridine in plasma from other species, such as human.  相似文献   

14.
Mohammed Zougagh 《Talanta》2009,79(2):284-1947
A simple and enantioselective method for the determination of menthone enantiomers in peppermint essential oil samples is proposed. The method involves the initial supercritical fluid extraction (SFE) to clean-up and extraction of analytes and their preconcentration on C18 adsorption cartridges followed by achiral liquid chromatographic separation and direct circular dichroism (CD) detection. The calibration curve of the anisotropy factor (g) versus the enantiomeric excess was linear, with a correlation coefficient (R2) of 0.9970. The precision evaluated by UV peak area and CD peak area was suitable both in terms of intra- and inter-day precision (RSD < 5.1% in all cases). The usefulness of the proposed method was demonstrated by analyzing natural and spiked peppermint oil samples. This method has the advantages of being rapid and precise without using an expensive chiral column. It was demonstrated to be suitable for the simultaneous determination of both enantiomers and for assessing the chemical purity of menthone.  相似文献   

15.
A simple and sensitive liquid chromatography/tandem mass spectrometry method employing electrospray ionization, to quantify lisinopril in human plasma using pseudoephedrine hydrochloride as the internal standard (IS), has been developed and validated. A mixture of methanol and 0.1% formic acid in water (50:50, v/v) was used as the isocratic mobile phase. A simple liquid-liquid extraction procedure was used as sample preparation method. The method validation demonstrated the specificity, lower limit of quantification, accuracy, and precision of measurements. Selected reaction monitoring was specific for lisinopril and pseudoephedrine hydrochloride; no endogenous materials from blank plasma interfered with the analysis of lisinopril or the IS. The assay was linear over the concentration range 0.78-100 ng/mL. The correlation coefficients for the calibration curves ranged from 0.9984-0.9998. The intra- and inter-day precision, determined for quality control samples, were less than 4.18%. The method was employed in a pharmacokinetic study after oral administration of 10 mg lisinopril to 20 healthy volunteers.  相似文献   

16.
In this paper, for the first time, surfactant‐assisted electromembrane extraction coupled with capillary electrophoresis with UV detector was introduced for the extraction of acidic drugs from biological fluids. In this technique, in the presence of the nonionic surfactant in the donor phase, tendency of analyte ions into the supported liquid membrane (SLM) was increased. Naproxen and diclofenac were selected as model acidic drugs. In order to obtain the best extraction efficiency, several factors influencing the extraction efficiency were investigated. Optimal extractions were accomplished with 1‐octanol as the SLM, 15 Volt dc potential as the driving force, pH 12 in acceptor solution, and 0.2 mmol/L Triton X‐100 with pH 7.4 in donor solution. Equilibrium extraction conditions were obtained after 15 min of operation where the whole assembly agitated at 1000 rpm. Under the optimized conditions, preconcentration factors in the range of 176–184 and recoveries in the range of 88–92% were obtained. The applied method offers acceptable linearity with correlation coefficients higher than 0.9992. Limits of detection of 1.51 ng/mL and 2.42 ng/mL were obtained for naproxen and diclofenac, respectively. Finally, the developed method was successfully applied for the determination of naproxen and diclofenac in different matrices including plasma and urine samples.  相似文献   

17.
A rapid, sensitive and specific LC-MS-MS method has been developed for the determination of clarithromycin (CLA) in human plasma using roxithromycin (ROX) as the internal standard. Samples were prepared via liquid-liquid extraction with methyl tert-butyl ether (MTBE) and chromatographed on a Supelco RP(18) (4.6 x 50 mm, 3 microm particle size) column with a mobile phase consisting of acetonitrile:methanol:60 mM (pH 3.5) ammonium acetate buffer (32.5:32.5:35) at a constant flow rate of 0.8 mL/min. The run time was 3 min with retention times of approximately 1.65 and 1.70 min for CLA and ROX, respectively. Detection was performed on a PE Sciex API 365 mass spectrometer equipped with a turboionspray ionization source in multiple reaction monitoring (MRM) mode. The MRM pairs were m/z 748.5 --> m/z 158.2 for CLA and m/z 837.7 --> m/z 679.3 for ROX, respectively, with dwell times of 200 ms for each transition. The validated calibration curve range was 5.00-5000 ng/mL, based on 0.100 mL plasma sample volume with signal-to-noise ratio (S/N) greater than 60 for CLA at the lower limit of quantification level (5.00 ng/mL). The correlation coefficients (r(2)) of the calibration curves were better than or equal to 0.996. The inter-day (n = 18) precision and accuracy of the quality control (QC) samples were less than 3.58% RSD (relative standard deviation) and -10.8% bias, respectively. The intra-day (n = 6) precision and accuracy of the quality control samples were less than 5.0 and 12.6%, respectively. There was no significant deviation from the nominal values after a 10-fold dilution of high concentration QC samples using blank matrix. The QC samples were stable when left on the bench for 24 h or after three freeze-thaw cycles. The processed samples were also stable in HPLC autosampler at 10C for over 72 h. No matrix ionization suppression was observed when extracted blank matrix or reconstitution solvent was injected onto the system with post-column infusion of clarithromycin and roxithromycin. No carryover was observed when an extracted blank plasma sample was injected immediately after a 5000 ng/mL ULOQ (the upper limit of quantification) standard. The mean recovery was 81.5 and 78.3%, respectively, for clarithromycin and internal standard.  相似文献   

18.
The use of DSC curves is proposed as an alternative method to determine the degree of N-acetylation (DA) in chitin/chitosan samples, based in both peak area and height of the decomposition signal. Samples with DA from 74 to 16% were prepared from a chitin commercial sample and the DA was determined by 1H NMR, 13C CP/MAS NMR and IR spectra. The effect of water content, heating rate, sample mass and gas flow on the DSC peaks were evaluated and optimized. Using optimized conditions a linear relationship between peak area and height with the DA could be achieved with linear correlation coefficients of −0.998 and −0.999 (n = 7), respectively. The calibration graphs were used to determine the DA of a commercial chitosan sample with relative errors ranging from 2 to 3% for both peak area and peak height, when compared with the DA determined by 1H NMR method.  相似文献   

19.
A highly sensitive, specific and simple LC–MS/MS method for quantification of capmatinib (INC280) in rat plasma was presented. The LC–MS/MS method was validated in terms of specificity and selectivity, linearity, accuracy and precision, matrix effect, extraction recovery, dilution integrity, carryover and stability as per the US Food and Drug Administration's bioanalytical method validation guideline. The validated assay was applied for quantification of capmatinib from a pharmacokinetic study in rats following oral administration at the doses of 1.0, 3.0 and 9.0 mg/kg. The calibration curve ranges from 1 to 2000 ng/ml with desirable linearity and r2 > 0.99. The intra- and inter-batch accuracies were within 99.24–103.59 and 97.76–102.83% with coefficients of variation 5.08–7.36 and 3.18–4.99%, respectively. No significant interference was observed by endogenous peak at the retention time of capmatinib and IS. The assay was free from any matrix effect and showed precise recovery across the calibration curve range, and samples were stable under all experimental conditions. The validated assay was successfully applied to analyze plasma samples of pharmacokinetic study in rat to determine the concentration of capmatinib. In summary, a novel method for analyzing capmatinib in rat plasma has been successfully validated and is now being utilized for quantification of capmatinib from pre-clinical studies.  相似文献   

20.
In a recent collaborative study intended to extend the variety of reference materials certified for iodine, three mineralization methods were developed to quantify the total iodine content of biological and nutritional materials by inductively coupled plasma mass spectrometry (ICP-MS). A mixture of water-soluble tertiary amines was used as the matrix solution for two oxygen combustion methods and for a simple extraction at room temperature. Calibrations with matrix-matched standards, internal calibration, and isotope dilution with 129I were used. Good agreement between neutron activation analysis (NAA) and the two combustion methods was observed except for < 0.1 mg kg–1 iodine concentrations. The amine extraction method gave the most reliable results for the mixed diet, milk powder, and infant formula samples but low recoveries for other biological materials owing to an incomplete extraction and solubilization of iodine. The NAA method, with its freedom from reagent blank, is a useful technique for the independent determination of iodine in biological, environmental and food matrices, especially for verification of iodine results obtained by ICP-MS. Received: 11 February 1998 / Revised: 21 April 1998 / Accepted: 16 June 1998  相似文献   