首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple, rapid, sensitive and reliable liquid chromatography–electrospray ionization mass spectrometry method for the quantification of imperatorin in rat plasma after oral administration and total furocoumarins of Radix Angelica dahuricae has been established. The plasma samples were deproteinized by adding internal standard (IS) osthole solution, which was prepared by acetonitrile. The analysis was performed on a Shim-pack C18 column (150 × 2.0 mm i.d., 5 μm) using acetonitrile and 0.5% formic acid solution (70:30, v/v) as a mobile phase. The detection was performed on a quadrupole mass spectrometer detector with an ESI interface operated in the selected ion monitoring mode. The linear quantification range of the method was 2–4000 ng mL?1 in rat plasma with a correlation coefficient greater than 0.99, the limit of detection (LOD) was 0.5 ng mL?1 and the lower limit of quantification (LLOQ) 2 ng mL?1. The intra- and inter-day relative standard deviations (RSD) were less than 2.5 and 3.5%, respectively. The recoveries were above 90%. The validated method was successfully applied to a pharmacokinetic study of imperatorin in rats after oral administration and total furocoumarins of Radix Angelica dahuricae.  相似文献   

2.
A highly sensitive liquid chromatographic-atmospheric pressure chemical ionization-tandem mass spectrometric method is developed to quantitate phenacetin and its metabolite paracetamol in rabbit plasma. The analytes and internal standard oxazepam are extracted from plasma by liquid–liquid extraction using ethyl acetate, and separated on a Zorbax SB-C18 column (2.1 mm × 150 mm, 5 μm) using acetonitrile–0.1% formic acid in water (40:60 v/v) at a flow of 0.4 mL min?1. Detection is carried out by multiple reaction monitoring on a ion-trap LC-MS-MS system with an atmospheric pressure chemical ionization interface. The assay is linear over the range 4–1,600 ng mL?1 for phenacetin and 3–2,000 ng mL?1 for paracetamol, with a lower limit of quantitation of 4 ng mL?1 for phenacetin and 3 ng mL?1 for paracetamol. Intra- and inter-day precision are less than 7.1% and the accuracy are in the range 97.3–103.5%. The validated method is successfully used to analyze the drug in samples of rabbit plasma for pharmacokinetic study.  相似文献   

3.
Xin Hu  Yun-Feng Lv  Kai-Shun Bi 《Chromatographia》2009,69(9-10):1073-1076
A rapid and simple high-performance liquid chromatographic tandem mass spectrometric method has been developed and validated for analysis of strictosamide in rat plasma. Chromatographic separation was achieved on a C18 column by gradient elution with mixtures of methanol, water, and acetonitrile containing 0.05% acetic acid. Digoxin was used as internal standard. Selected reaction monitoring (SRM) was used for MS quantitation. Linearity was good in the range 0.05–20 ng mL?1 in rat plasma. The lower limit of quantitation was 0.04 ng mL?1. The method is precise and reliable and can be applied to pharmacokinetic studies.  相似文献   

4.
A reliable and sensitive liquid chromatographic–tandem mass spectrometric method, with rutin as internal standard, has been developed and validated for simultaneous determination of danshensu, salvianolic acid B (SAB), and hydroxysafflor yellow A (HSYA) in beagle dog plasma. Plasma samples spiked with the analytes were extracted by solid-phase extraction and the analytes were separated on a 250 × 4.6 mm i.d., 5-μm particle, C18 column with methanol–acetonitrile–0.5% formic acid 20:25:55 (v/v) as mobile phase at a flow rate of 1 mL min?1. LC–MS–MS analysis was performed with a Finnigan TSQ triple-quadrupole tandem mass spectrometer operated in negative-ion selected-reaction-monitoring mode, using electrospray ionization. The accuracy and precision of the method were acceptable and linearity was good over the range 20–4,000 ng mL?1 for danshensu, 50–10,000 ng mL?1 for SAB, and 10–2,000 ng mL?1 for HSYA. The method was successfully applied to a pharmacokinetic study of a traditional Chinese medicinal preparation, Danhong lyophilized powder for injection.  相似文献   

5.
A valid and sensitive LC-MS–MS method is adopted for pharmacokinetics study of berberine and palmatine in rabbit plasma. After mixing with internal standard tetrahydroberberine, plasma samples were pretreated with 1.5 mL acetonitrile. Chromatographic separation was on a C18 column using a mixture of water (containing 10 mmol L?1 ammonium acetate, pH 3.5) and acetonitrile (50∶50, v/v) as mobile phase. The detection was performed by selected ion monitoring mode via electrospray ionization source operating in the positive ionization mode. The method was linear over the concentration range of 2.0–200.0 ng mL?1 for berberine and 1.0–100.0 ng mL?1 for palmatine. The lowest limits of quantitation (LLOQ) were 2.0 ng mL?1 for berberine and 1.0 ng mL?1 for palmatine. The intra- and inter-day precision values were less than 14.3% and the deviations were within ±11.0%. The fully validated LC-MS–MS method has been successfully applied to a pharmacokinetic study of berberine, palmatine in rabbit plasma after oral administration of Coptidis and coptidis–gardeniae couple extract. The results indicated that the plasma profiles of the two compounds in rabbit confirmed to one-compartment open model and the combinational utilization with Gardeniae could increase the bioavailability of berberine and palmatine, the two major active components of Coptidis.  相似文献   

6.
A simple, rapid and sensitive HPLC method has been developed and validated for the analysis of letrozole in human plasma. The separation was achieved on a monolithic silica column using acetonitrile–phosphate buffer. A fluorescence detector was used for the quantitation with excitation and emission wavelengths at 230 and 295 nm. The assay enables the measurement of letrozole for therapeutic drug monitoring with a minimum quantification limit (LOQ) of 0.5 ng mL?1. The method involves a simple, one-step extraction procedure with complete recovery. Calibration was linear over the concentration range 0.5–80 ng mL?1. The coefficients of variation for inter-day and intra-day assay were found to be less than 8%.  相似文献   

7.
A selective, sensitive, and accurate method has been developed and validated for the quantification of tangeretin in rat plasma. The application of LC-electrospray-ion trap mass spectrometry in full scan and multiple reactions monitoring modes were investigated. Following solid phase extraction using a hydrophilic–lipophilic balance cartridge, the analytes were separated on a C18 column using an isocratic mobile phase composed of acetonitrile/water (50:50, v/v) containing 0.3% formic acid. In full scan mode, the LOQ was 2 ng mL?1. The standard calibration curve was linear (R 2 = 0.9999) over the concentration range 2–200 ng mL?1. The precision over the concentration range was within 15% (RSD) and the accuracy was ranged from 86 to 115%. In multiple reaction monitoring mode, the LOQ was 1 ng mL?1 and the standard calibration curve was linear (R 2 = 0.9976) over the concentration range 1–100 ng mL?1 with a precision of 12% and accuracy rangeing from 91 to 113%.  相似文献   

8.
A rapid and specific high-performance liquid chromatographic method coupled with electrospray ionization mass spectrometric detection has been developed and validated for identification and quantification of wogonin and oroxylin A in rat plasma. Wogonin, oroxylin A, and diazepam (internal standard) were extracted from plasma samples by liquid–liquid extraction with ethyl acetate. Chromatographic separation was achieved on a C18 column with acetonitrile–0.6% aqueous formic acid 35:65 (v/v) as mobile phase at a flow rate of 0.2 mL min?1. Detection was performed with a single-quadrupole mass spectrometer in selected-ion-monitoring (SIM) mode. Linearity was good within the concentration range 14.4–360 ng mL?1 for wogonin and 10.8–271 ng mL?1 for oroxylin A; the correlation coefficients (r 2) were 0.9999. The intra-day and inter-day precision, as RSD, was below 12.4%, and accuracy ranged from 81.1 to 111.9%. The lower limit of quantification was 14.4 ng mL?1 for wogonin and 10.8 ng mL?1 for oroxylin A. This method was successfully used in the first pharmacokinetic study of wogonin and oroxylin A in rat plasma after oral administration of the active fraction from Xiao-xu-ming decoction.  相似文献   

9.
A simple, sensitive, and precise high performance liquid chromatographic method for the analysis of pantoprazole, rabeprazole, esomeprazole, domperidone and itopride, with ultraviolet detection at 210 nm, has been developed, validated, and used for the determination of compounds in commercial pharmaceutical products. The compounds were well separated on a Hypersil BDS C18 reversed-phase column by use of a mobile phase consisting of 0.05 M, 4.70 pH, potassium dihydrogen phosphate buffer - acetonitrile (720:280 v/v) at a flow rate of 1.0 mL min?1. The linearity ranges were 400–4,000 ng mL?1 for pantoprazole, 200–2,000 ng mL?1 for rabeprazole, 400–4,000 ng mL?1 for esomeprazole, 300–3,000 ng mL?1 for domperidone and 500–5,000 ng mL?1 for itopride. Limits of detection (LOD) obtained were: pantoprazole 147.51 ng mL?1, rabeprazole 65.65 ng mL?1, esomeprazole 131.27 ng mL?1, domperidone 98.33 ng mL?1 and itopride 162.35 ng mL?1. The study showed that reversed-phase liquid chromatography is sensitive and selective for the determination of pantoprazole, rabeprazole, esomeprazole, domperidone and itopride using single mobile phase.  相似文献   

10.
Fang Gao  Li Ding  Pengcheng Ma  Fei Wu 《Chromatographia》2010,71(11-12):1007-1014
Zofenoprilat is an active metabolite of zofenopril, which is very unstable in plasma because of oxidative degradation of its thiol group. In this method, p-bromophenacyl bromide was used as derivatization reagent, immediately after plasma separation, to react with the free thiol group of zofenoprilat and form the derivative zofenoprilat-p-BPB. After acidification with 50% acetic acid, the derivatized plasma samples were extracted with methyl tert-butyl ether and separated on a C18 column with 40:60 (v/v) 10 mM ammonium acetate buffer solution containing 0.1% formic acid–acetonitrile as mobile phase. Calibration plots were linear over the concentration range 1–500 ng mL?1 for zofenopril and 2–1,800 ng mL?1 for zofenoprilat. The method was successfully used to study the bioavailability of zofenopril calcium capsules relative to that of zofenopril calcium tablets in healthy Chinese volunteers.  相似文献   

11.
A sensitive and rapid LC–MS–MS method was developed for the simultaneous determination of ebastine and carebastine in human plasma. Solid-phase extraction was used to isolate the compounds from the biological matrix followed by separation on a Symmetry C18 column under isocratic conditions. The mobile phase was 10 mM ammonium formate in water/acetonitrile (40:60, v/v). Detection was carried out using a triple-quadrupole mass spectrometer in positive electrospray ionization and multiple reaction monitoring mode. The method was fully validated over the concentration range of 0.1–10 ng mL?1 for ebastine and 0.2–200 ng mL?1 for carebastine in human plasma, respectively. The lower limit of quantification (LLOQ) was 0.1 ng mL?1 for ebastine and 0.2 ng mL?1 for carebastine. For ebastine and carebastine inter- and intra-day precision (CV%) and accuracy values were all within ±15% and 85–115%, respectively. The extraction recovery was on average 60.0% for ebastine and 60.3% for carebastine.  相似文献   

12.
13.
A sensitive and selective liquid chromatography tandem mass spectrometry method for quantitative determination of lobeline hydrochloride in rabbit plasma was developed and validated. After addition of triazolam as internal standard, protein precipitation by acetonitrile was used as sample preparation. Chromatographic separation was achieved on a Zorbax SB-C18 column with acetonitrile-0.1% formic acid as mobile phase with gradient elution. Electrospray ionization source was applied and operated in positive ion mode; multiple reaction monitoring mode was used for quantification using target fragment ions m/z 338.1 → 315.8 for lobeline hydrochloride and m/z 342.9 → 308.0 for the IS. Calibration plots were linear over the range of 2–500 ng mL?1 for lobeline hydrochloride in plasma. Lower limit of quantitation for lobeline hydrochloride was 2 ng mL?1. Mean recovery of lobeline hydrochloride from plasma was in the range 97.5–102.3%. RSD of intra-day and inter-day precision were both <9%. This developed method is successfully used in pharmacokinetic study of lobeline hydrochloride in rabbit.  相似文献   

14.
A gradient liquid chromatography-tandem mass spectrometry method has been developed and validated for the determination of gastrodin and ligustrazine hydrochloride in rat plasma and brain dialysates. Zolpidem was used as internal standard. For plasma samples, solid-phase extraction was used and the brain dialysates were collected from freely moving rats using brain microdialysis. Both were followed by HPLC separation and positive electrospray ionization tandem mass spectrometry detection (ESI–MS–MS). Chromatographic separation was achieved on a Symmetry RP-18 column using gradient elution with methanol and water containing 0.5% formic acid and 2 mM ammonium formate. Selected reaction monitoring (SRM) mode was used for quantitation. Good linearities were obtained in the range of 0.05–100 and 0.01–50 μg mL?1 for gastrodin and ligustrazine hydrochloride in rat plasma, and 0.05–1,000 ng mL?1 for both in dialysate. The lower limit of quantitation was 0.01 ng mL?1 for gastrodin and 0.05 ng mL?1 for ligustrazine. The method is precise and reliable and can be applied to pharmacokinetic studies.  相似文献   

15.
《Analytical letters》2012,45(14):2157-2169
Abstract

A rapid, sensitive, and specific liquid chromatography–tandem mass spectrometric (HPLC-MS/MS) method has been developed for quantification of ferulic acid in rat plasma. The analyte and docetaxel (internal standard) were extracted from plasma samples with diethyl ether and analyzed on a C18 column. The chromatographic separation was achieved within 3.5 min by using acetonitrile-water as the mobile phase and the flow rate was 0.2 mL · min?1. The method was linear within the range of 0.5 ? 800 ng · mL?1. The lower limit of quantification (LLOQ) was 0.5 ng · mL?1. Finally, the method is successfully applied for the pharmacokinetic study of ferulic acid in rats following intravenous administration.  相似文献   

16.
A sensitive, simple, and accurate method for determination and pharmacokinetic study of ferulic acid and isoferulic acid in rat plasma was developed using a reversed-phase column liquid chromatographic (RP-LC) method with UV detection. Sample preparations were carried out by protein precipitation with the addition of methanol, followed by evaporation to dryness. The resultant residue was then reconstituted in mobile phase and injected into a Kromasil C18 column (250 × 4.6 mm i.d. with 5 μm particle size). The mobile phase was methanol-1% formic acid (33:67, v/v). The calibration plots were linear over the range 5.780–5780 ng·mL?1 for ferulic acid and 1.740–348.0 ng·mL?1 for isoferulic acid. Mean recoveries were 85.1% and 91.1%, respectively. The relative standard deviations (RSDs) of within-day and between-day precision were not above 15% for both of the analytes. The limits of quantification were 5.780 ng·mL?1 for ferulic acid and 1.740 ng·mL?1 for isoferulic acid. This RP-LC method was used successfully in pharmacokinetic studies of ferulic acid and isoferulic acid in rat plasma after intravenous injection of Guanxinning Lyophilizer.  相似文献   

17.
The purpose of this article was to develop a rapid and robust LC–MS–MS method for quantifying shikonin and deoxyshikonin simultaneously in rat plasma using emodin as internal standard. The LC system consisted of an Agilent ZORBAX SB-C18 (1.8 μm, 250 × 4.6 mm, 20 °C) column. Elution with an isocratic mobile phase consisted of methanol/10 mM ammonium acetate in water/acetonitrile containing 0.05% formic acid (45:10:45, v/v/v) at a flow rate of 0.8 mL min?1 yielded sharp, high-resolved peaks within 12 min. The lower limits of quantitation were 0.5 ng mL?1 for shikonin, and 8 ng mL?1 for deoxyshikonin. Correlation coefficient (r) values for the linear range of two analytes were greater than 0.99. Assay precision was <13% and accuracy was 87–99%. This newly developed method was used to the pharmacokinetic studies of the shikonin analogues in rats after intravenous administration (n = 4).  相似文献   

18.
A simple and rapid method using liquid chromatography-mass spectrometry was developed and applied to determine the concentration of huperzine A in rat plasma or cerebrospinal fluid following a single intravenous injection or nasal administration. The chromatographic separation of the analytes was performed by column switching. A Zorbax SB-C18 pre-column was used as the first column for sample clean-up, and then the analytes were eluted onto a Zorbax SB-C18 column, the second column, and detected by electrospray ionization MS using single ion monitoring in positive mode. Hup B was used as internal standard. Linear calibration curve was achieved over a dynamic range of 0.5–500 ng mL?1 for Hup A in plasma sample and 0.5–200 ng mL?1 in CSF sample. The inter- and intra-assay coefficients of variation for the analysis were within ±6.67%. The mean absolute recoveries of Hup A from plasma were between 94.7 and 106.7%.  相似文献   

19.
A simple, sensitive and specific liquid chromatographic method with UV detection (228 nm) was developed for the simultaneous estimation of rosiglitazone and glimepride in human plasma. Rosiglitazone and glimepride were extracted from plasma using liquid–liquid extraction. Separation was achieved with an RP C18 Column using a mixture of phosphate buffer (50 mM) with octane sulfonic acid (10 mM), methanol and acetonitrile as a mobile phase (55:10:35, v/v). pH was adjusted to 7.0. Amlodipine was used as an internal standard (IS). LOD of the method was found to be 20 ng mL?1 for both drugs. Results were linear over the studied range 40.994–2007.556 ng mL?1 for rosiglitazone (r ≥ 0.99) and 41.066–2094.84 ng mL?1 for glimepride( r ≥ 0.99). The method was found to be simple, selective, precise and reproducible for the estimation of both drugs from spiked human plasma.  相似文献   

20.
A simple, sensitive and rapid ultra-performance liquid chromatography-mass spectrometry (UPLC-MS) method was developed and validated for the quantification of mitragynine in rat plasma using amitriptyline hydrochloride as an internal standard. Sample preparation involved a one-step liquid?Cliquid extraction using methyl t-butyl ether. Mitragynine was separated on an Acquity UPLC? BEH HILIC column using isocratic elution with a mobile phase of 10 mM ammonium formate buffer containing 0.1% formic acid:acetonitrile (15:85, v/v). At a flow rate of 0.2 mL min?1, the retention time of mitragynine was found to be 1.3 min. Ionization was performed in the positive ion electrospray mode. The selected mass-to-charge (m/z) ratio transition of mitragynine ion [M + H]+ used in the selected ion recording (SIR) was 399.1. The calibration curve was found to be linear over a concentration range of 1?C5,000 ng mL?1 (r = 0.999) with a lower limit of quantification (LLOQ) of 1 ng mL?1. Intra- and inter-day assay variations were found to be less than 15%. The extraction recoveries ranged from 85?C93% at the three concentrations (2, 400 and 4,000 ng mL?1) in rat plasma. This method was successfully used to quantify mitragynine in rat plasma following intravenous administration of the compound.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号