首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
In this approach a fluorometric technique has been developed to study chromium speciation, based on optimised conditions using chemometric methods of experimental design and central composite design. Full and fractional factorial design was used for evaluation of the effective factors in determination of Cr(VI) by fluorometric using Rhodamine-6G in the presence of H2SO4. Theory and methodology of a central composite design as a chemometric method for the optimisation of analytical procedures were developed in this approach. It was found that the analytical performance for measurement at the point of optimum in this technique is superior and more accurate than that of one variable at a time. Cr(VI) and Cr(III) were measured in a wastewater sample using the proposed technique. The results confirm the selective determination and speciation of Cr(VI)/Cr(III).  相似文献   

2.
荧光法测定硫酸软骨素含量的新方法   总被引:1,自引:0,他引:1  
在pH=5.0的乙酸-乙酸钠缓冲溶液中,结晶紫在232.0 nm光的激发下,于467.0 nm处有一个荧光峰,其与硫酸软骨素(Chs)反应生成的缔合物在467.0 nm处荧光强度增强,且荧光强度差值与Chs浓度在0.002~1.7μg/mL范围内呈线性关系,相关系数(R)达到0.9997,回收率在99.73%~100.51%.该方法快速、灵敏和准确,可用于硫酸软骨素定量检测.  相似文献   

3.
A method for speciation of Cr(III) and Cr(VI) in real samples has been developed. Cr(VI) has been separated from Cr(III) and preconcentrated as its pyrrolidinedithiocarbamate (APDC) complex by using a column containing Amberlite XAD–2000 resin and determined by FAAS. Total chromium has also been determined by FAAS after conversion of Cr(III) to Cr(VI) by oxidation with KMnO4. Cr(III) has been calculated by subtracting Cr(VI) from the total. The effect of pH, flow‐rate, adsorption and batch capacity and effect of various metal cations and salt anions on the sorption onto the resin were investigated. The adsorption is quantitative in the pH range of 1.5–2.5, and Cr(VI) ion was desorbed by using H2SO4 in acetone. The recovery of Cr(VI) was 97 ± 4 at a 95% confidence level. The highest preconcentration factor was 80 for a 200 mL sample volume. The adsorption and batch capacity of sorbent were 7.4 and 8.0 mg g?1 Cr(VI), respectively, and loading half time was 5.0 min. The detection limit of Cr(VI) is 0.6 μg/L. The procedure has been applied to the determination and speciation of chromium in stream water, tap water, mineral spring water and spring water. Also, the proposed method was applied to total chromium preconcentration in microwave digested moss and rock samples with satisfactory results. The developed method was validated with CRM‐TMDW‐500 (Certified Reference Material Trace Metals in Drinking Water) and BCR‐CRM 144R s (Certified Reference Material Sewage Sludge, Domestic Origin) and the results obtained were in good agreement with the certified values. The relative standard deviations were below 6%.  相似文献   

4.
Abstract

The coupling of ion chromatography (IC) and inductively-coupled plasma mass spectrometry (ICP-MS) provides a powerful tool for the simultaneous determination of Cr(III) and Cr(VI) in water samples. The experimental set-up of the technique is described in detail and performance data are given, whereby detection limits of 0.1 μg/l could be achieved for both chromium species without pre-concentration. With this method, a complete analysis can be done in less than 3 minutes. In order to improve the repeatability of the method, Rh(III) as internal standard is used. Stability of the two chromium species in water turned out to be a major problem and optimal conditions for storage were determined. For real water samples storage at 4 °C in the dark at neutral pH and analysis as fast as possible is recommended. The application of the IC-ICP-MS technique to real water samples and the comparison to another, more time-demanding and less sensitive method proves the capacity of the method.  相似文献   

5.
A new solid phase extraction (SPE) method has been developed for the speciation of Cr(III) and Cr(VI). This method is based on the adsorption of Cr(VI) on modified alumina‐coated magnetite nanoparticles (ACMNPs). Total chromium in different samples was determined as Cr(VI) after oxidation of Cr(III) to Cr(VI) using H2O2. The chromium concentration has been determined by flame atomic absorption spectrometric (FAAS) technique and amount of Cr(III) was calculated by substracting the concentration of Cr(VI) from total chromium concentration. The effect of parameters such as pH, amount of adsorbent, contact time, sample volume, eluent type, H2O2 concentration and cetyltrimethylammonium bromide (CTAB) concentration as modifier on the quantitative recovery of Cr(VI) were investigated. Under the optimal experimental conditions, the preconcentration factor, detection limit, linear range and relative standard deviation (RSD) of Cr(VI) were 140 (for 350 mL of sample solution), 0.083 ng mL?1, 0.1‐10.0 ng mL?1 and 4.6% (for 5.0 ng mL?1, n = 7), respectively. This method avoided the time‐consuming column‐passing process of loading large volume samples in traditional SPE through the rapid isolation of CTAB@ACMNPs with an adscititious magnet. The proposed method was successfully applied to the determination and speciation of chromium in different water and wastewater samples and suitable recoveries were obtained.  相似文献   

6.
The possibility of using moss (Funaria hygrometrica), immobilized in a polysilicate matrix as substrate for speciation of Cr(III) and Cr(VI) in various water samples has been investigated. Experiments were performed to optimize conditions such as pH, amount of sorbent and flow rate, to achieve the quantitative separation of Cr(III) and Cr(VI). During all the steps of the separation process, Cr(III) was selectively sorbed on the column of immobilized moss in the pH range of 4-8 while, Cr(VI) was found to remain in solution. The retained Cr(III) was subsequently eluted with 10 ml of 2 mol l−1 HNO3. A pre-concentration factor of about 20 was achieved for Cr(III) when, 200 ml of water was passed. The immobilized moss was packed in a home made mini-column and incorporated in flow injection system for obtaining calibration plots for both Cr(III) and Cr(VI) at low ppb levels that were compared with the plots obtained without column. After separation, the chromium (Cr) species were determined by inductively coupled plasma mass spectrometry (ICP-MS) and flame atomic absorption spectrometry (FAAS). The sorption capacity of the immobilized moss was found to be ∼11.5 mg g−1 for Cr(III). The effect of various interfering ions has also been studied. The proposed method was applied successfully for the determination of Cr(III) and Cr(VI) in spiked and real wastewater samples and recoveries were found to be >95%.  相似文献   

7.
 A method is described for the quantitative preconcentration and separation of trace chromium in water by adsorption on melamine-urea-formaldehyde resin. Cr(VI) is enriched from aqueous solutions on the resin. After elution the Cr(VI) is determined by FAAS. The capacity of the resin is maximal at ∼ pH 2. Total chromium can be determined by the method after oxidation of Cr(III) to Cr(VI) by hydrogen peroxide. The relative standard deviations (10 replicate analyses) for 10 mg/L levels of Cr(VI), Cr(III) and total chromium were 1.5, 3.5 and 2.8% respectively. The procedure has been applied to the determination and speciation of chromium in lake water, tap water and chromium-plating baths.  相似文献   

8.
《Analytical letters》2012,45(13-14):2877-2885
Abstract

The adsorption studies of Cr(VI) in presence of Cr(III) on the sulphide of Lead, Zinc and Copper has been studied. It has been found that in case of lead sulphide 100% adsorption of Cr(VI) took place at pH 4.0 and of Cr(III) at pH 7.0. While in case of zinc sulphide the 100% adsorption of Cr(VI) took place at pH 4.5 and of Cr(III) at pH 6.5. In case of copper sulphide 100% adsorption of Cr(VI) took place at pH 5.0 and of Cr(III) at pH 7.0. This difference in adsorption at different pH values forms the basis for the determination of these ions. The method is accurate.  相似文献   

9.

Twenty-five uncultivated surface soil samples collected from the northern and southern regions of Dhaka Export Processing Zone (DEPZ), industrial area of Bangladesh, were analyzed for their contents of Y, lanthanides and natural radionuclides (Th and U) using an inductively coupled plasma mass spectrometer (ICP-MS). Analogous concentrations of the Y, lanthanides, Th and U were observed in the both regions of DEPZ around several kilometer distances. Further, the measured values showed no particular contamination. However, the concentrations of the light lanthanides (La, Ce and Nd) in the Bangladeshi soils were around twice the worldwide average value. But, the smooth curve of the chondrite normalized patterns of the lanthanides suggested that the lanthanide contents of the Bangladeshi soils in this area are the results of the natural dispersion process rather than anthropogenic activities. In addition, the relatively high Th and U concentrations and Th/U ratio were observed in Bangladeshi soils of this area, most likely due to the effect of their parent materials such as clay stones which have a high Th/U ratio. Since this is the first precise result for the Y, lanthanides, Th and U contents in Bangladeshi soils, it could be useful in understanding the background level and the characteristics of these elements in Bangladeshi soils.  相似文献   

10.
In the present work, the catalytic adsorptive stripping voltammetric procedure for trace determination of Cr(VI) in the presence of a high excess of Cr(III) in natural waters with a complicated matrix has been developed. The influence from potentially interfering substances such as organic matter was successfully eliminated by exploiting adsorptive properties of polymeric resin. The detection limit estimated from 3 times the standard deviation for a low Cr(VI) concentration in the simultaneous presence of a 2×103 fold excess of Cr(III), 50 mg L?1 surfactants, 50 mg L?1 humic substances and the accumulation time of 30 s was about 5.3×10?10 mol L?1.  相似文献   

11.
A sensitive and selective protocol for the extraction of all forms of Cr(VI) from solid materials followed by determination by catalytic adsorptive stripping voltammetry has been elaborated. Cr(VI) was leached to a solution with 0.2 mol L?1 (NH4)2SO4/NH4OH+0.1 mol L?1 EDDS (pH 9.5) and simultaneously Cr(III) was transferred to a nonactive electrochemical complex with EDDS. The method allows for Cr(VI) determination in solid samples containing even a 1000–2000 fold excess of extractable Cr(III) without its noticeable influence. The effects of several experimental variables such as the composition and pH of the extractant, the time and temperature of the solid sample mixing with the extractant were studied. At the optimized conditions more than 95% of total Cr(VI) recoveries from solid samples were achieved. The validation of the proposed procedure was carried out by Cr(VI) determination in certified reference material CRM 019 Ash, spiked and unspiked with Cr(III), and by comparing the obtained results with those obtained using other common extraction procedures.  相似文献   

12.
Threshold values for Cr(VI) in various types of solid matrices have been set up to protect human health and biota. To ascertain the compliance of solids with these limits different types of extractants and different conditions of pH and temperature have been proposed in the literature. These extraction procedures are reviewed and their potentialities in quantitatively extracting Cr(VI) from solids without inducing undesired Cr(VI)–Cr(III) interconversions during the extraction are carefully evaluated. This evaluation takes into account the knowledge of the kinetics of most important redox reactions of chromium gathered in recent years. Among possible Cr(VI) reductants made available during the digestion, a number of species including Fe(II), sulphide, sulfite and humic matter were considered, while oxidants included hydrogen peroxide, dissolved oxygen, manganese oxides. Theoretical calculations suggest that pH higher than 10, high temperature and high concentrations of carbonate and magnesium ions minimize Cr(III)–Cr(VI) interconversions. The EPA Method 3060A meets these basic requirements. However, the applicability of this method to the analysis of Cr(VI) in soil and sediment samples, whose extracts may suffer from the interference by humic matter, is questionable.  相似文献   

13.
Summary Chromium can be present in aqueous solution as Cr(VI) or in monomeric, dimeric, trimeric and higher polymeric forms of Cr(III). Many monomeric forms of Cr(III) are possible, with the water molecules of Cr(H2O) 6 3+ substituted by anionic or neutral species. This proliferation of Cr(III) species makes the complete speciation of chromium a continuing challenge to the analyst. A simple and effective cation exchange procedure for the separation of various of these species uses a small glass column containing 1 mL of pre-treated cation exchange resin (Na+ form). Stepwise elution with solutions of perchloric acid, Ca2+ (pH=2) and La3+ (pH=2) separates Cr(VI) and seven Cr(III) species from CrX3 to tetramer. Radiometric (Cr-51), spectrophotometric and other detection methods can be employed; the use of radiochromium gives the lowest detection limit.  相似文献   

14.
A simple, rapid, and selective on-line method for the speciation and determination of Cr(III) and Cr(VI) in aqueous solutions by ion-pairing HPLC coupled with flame atomic absorption spectrometry (FAAS) is described. The composition of the mobile phase has been optimized for better separation. The effects of column temperature, volume of injection loop, fuel flow rate of FAAS, and nebulizer suction rate of FAAS have also been investigated. Separation is accomplished in almost 2.5 min on a 25 cm length C18 column at 40 degrees C. The selectivity of the method has been established by investigating the effect of interfering elements on chromium determination. The detection limit (3sigma) achieved by the method was calculated as 3.7 ng/mL for Cr(III) and 2.0 ng/mL for Cr(VI). The proposed method has been validated by analyzing certified reference material (BCR 544) and successfully applied to the analysis of drinking water and wastewater samples with a relative error below 6%.  相似文献   

15.
16.
《Electroanalysis》2017,29(5):1222-1231
A microbial sensor, namely carbon paste electrode (CPE) modified with Citrobacter freundii (Cf–CPE) has been developed for the detection of hexavalent (Cr(VI)) and trivalent (Cr(III)) chromium present in aqueous samples using voltammetry, an electroanalytical technique. The biosensor developed, demonstrated about a twofold higher performance as compared to the bare CPE for the chosen ions. Using cyclic voltammetry and by employing the fabricated Cf–CPE, the lowest limit of detection (LLOD) of 1x10−4 M and 5x10−4 M for Cr(VI) and Cr(III) ions respectively could be achieved. By adopting the Differential Pulse Cathodic Stripping Voltammetric technique, the LLOD could be further improved to 1x10−9 M and 1x10−7 M for Cr(VI) and Cr(III) ions respectively using the biomodified electrodes. The reactions occurring at the electrode surface‐chromium solution interface and the mechanisms of biosorption of chromium species onto the biosensor are discussed. The stability and utility of the developed biosensor for the analysis of Cr(VI) and Cr(III) ions in chromite mine water samples has been evaluated.  相似文献   

17.
A simple, inexpensive method based on solid-phase extraction (SPE) on sawdust from Cedrus deodera has been developed for speciation of Cr(III) and Cr(VI) in environmental water samples. Because different exchange capacities were observed for the two forms of chromium at different pH—Cr(III) was selectively retained at pH 3 to 4 whereas Cr(VI) was retained at pH 1—complete separation of the two forms of chromium is possible. Retained species were eluted with 2.5 mL 0.1 mol L−1 HCl and 0.1 mol L−1 NaOH. Detection limits of 0.05 and 0.04 μg mL−1 were achieved for Cr(III) and Cr(VI), respectively, with enrichment factors of 100 and 80. Recovery was quantitative using 250 mL sample volume for Cr(III) and 200 mL for Cr(VI). Different kinetic and thermodynamic properties that affect sorption of the chromium species on the sawdust were also determined. Metal ion concentration was measured as the Cr(VI)–diphenylcarbazide complex by UV–visible spectroscopy. The method was successfully applied for speciation of chromium in environmental and industrial water samples.  相似文献   

18.
The production of reference materials for quality control of Cr(III) and Cr(VI) speciation in environmental samples is described. It concerns in the first place two lyophilized solutions containing Cr(III) and Cr(VI) at different concentrations, respectively representative for drinking water and filter leaching solutions, and in the second place filters loaded with welding dust. Twenty-four laboratories with experience in the field participated in an intercomparison exercise organized to validate the suitability of the reference materials and to gauge the state-of-the-art of Cr speciation throughout Europe. The outcome of this exercise is discussed.  相似文献   

19.
An inductively coupled plasma atomic emission spectrometric (ICP-AES) method was developed for speciation and simultaneous determination of Cr and As, since these two analytes are commonly determined in various water samples in order to assess their toxicity. The objective of this research was to study the speciation of Cr(III), Cr(VI) in the presence of As(III) and/or As(V) using solid phase extraction (SPE) and ICP-AES. For these measurements, four spectral lines were used for each analyte with the purpose of selecting the most appropriate for each element. Finally with the use for first time of a cation-exchange column filled with benzosulfonic acid and elution with HCl, the speciation in solutions which contained [Cr(III)?+?Cr(VI)?+?As(V)] and [Cr(III)?+?Cr(VI)?+?As(III)] was examined. It was demonstrated that the separation of the two chromium species is almost quantitative and the simultaneous determination of chromium species and total arsenic analytes is possible, with very good performance characteristics. The estimated limits of detection for Cr(III), Cr(VI), As(III) and/or As(V) were 0.9?µg?L?1, 1.1 µg?L?1, 4.7 µg?L?1 and 4.5 µg?L?1 respectively, the calculated relative standard deviations (RSDs) were 3.8%, 4.1%, 5.2% and 5.1% respectively, and finally the accuracy of the methods was estimated using a certified aqueous reference material and found to be 5.6% and 4.8% for Cr(III) and Cr(VI) respectively. The method was applied to the routine analysis of various water samples.  相似文献   

20.
A new procedure for the speciation of chromium by means of differential pulse voltammetry using screen‐printed carbon electrodes (SPCEs) has been proposed. Two different modified carbon working, a Ag/AgCl reference and a carbon counter screen‐printed electrodes have been connected in array mode for the simultaneous determination of Cr(III) and Cr(VI). Mercury films or gold nanoparticles have been ground onto the SPCEs in order to improve their selectivity to each chromium species. The quantification of the peak currents observed at ?1.25 V in Hg‐SPCE and ?0.1 V in AuNPs‐SPCE were carried out. The method has been applied to the speciation of chromium in waste water from a tannery factory.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号