首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Combining fluorescence detection with flow analysis and solid phase extraction (SPE), a highly sensitive and automatic flow system for measurement of ultra-trace ammonium in open ocean water was established. Determination was based on fluorescence detection of a typical product of o-phthaldialdehyde and ammonium. In this study, the fluorescence reaction product could be efficiently extracted onto an SPE cartridge (HLB, hydrophilic–lipophilic balance). The extracted fluorescence compounds were rapidly eluted with ethanol and directed into a flow cell for fluorescence detection. Compared with the common used fluorescence method, the proposed one offered the benefits of improved sensitivity, reduced reagent consumption, negligible salinity effect and lower cost. Experimental parameters were optimized using a univariate experimental design. Calibration curves, ranging from 1.67 to 300 nM, were obtained with different reaction times. The recoveries were between 89.5 and 96.5%, and the detection limits in land-based and shipboard laboratories were 0.7 and 1.2 nM, respectively. The relative standard deviation was 3.5% (n = 5) for an aged seawater sample spiked with 20 nM ammonium. Compared with the analytical results obtained using the indophenol blue method coupled to a long-path liquid waveguide capillary cell, the proposed method showed good agreement. The method had been applied on board during a South China Sea cruise in August 2012. A vertical profile of ammonium in the South East Asia Time-Series (SEATS, 18° N, 116° E) station was produced. The distribution of ammonium in the surface seawater of the Qiongdong upwelling in South China Sea is also presented.  相似文献   

2.
《Analytical letters》2012,45(15):2503-2512
We report that ammonium ion, as its organic amine counterparts, can be sensitively detected as a coreactant in the electrochemiluminescence (ECL) reaction of a novel iridium complex (pq)2Ir(N-phMA), where pq is 2-phenylquinoline anion and N-phMA is N-phenylmethacrylamide. The modified ECL electrode was fabricated by casting deposition of a homogeneous MWNTs/PVA/(pq)2Ir(N-phMA) dispersion solution onto the surface of a glassy carbon electrode. The electrode responds sensitively to ammonium ion in a wide concentration range. Two regression equations were established: Y = 0.7016X + 46.8 (R2 = 0.9985) and Y = 0.2565X + 174.2 (R2 = 0.9991) for the concentration from 1–180 nM and 180–1800 nM, respectively. The limit of detection was as low as 0.13 nM (S/N = 3).  相似文献   

3.
《Analytical letters》2012,45(14):2275-2282
A flow injection technique combined with a chemiluminescence method was established for the determination of bovine serum albumin (BSA). Strong chemiluminescence was observed when BSA-dichlorofluoresce (DCF) complex was oxidized by sodium hypochlorite (NaClO) in an alkaline medium and in the presence of cetyltrimethylammonium bromide (CTAB). The reaction conditions of the chemiluminescence were carefully optimized. Under the optimal conditions, the method had a linear range of 0.01–20.0 μg/mL, with a detection limit of 0.007 μg/mL for BSA (3σ). The relative standard deviation of 1.0 μg/mL BSA (n = 8) is 1.4%. The method was applied to determine BSA in milk samples and it worked well.  相似文献   

4.
《Analytical letters》2012,45(7):1000-1013
Abstract

A Nafion/ionophore, 4-tert-butylcalix[4]arene-tetrakis(N,N-dimethylthioacetamide) composite coated and bismuth film modified glassy carbon electrode. (GC/NA-IONO/BiFE) was described to determine trace lead sensitively and selectively. The characteristics of such modified GC/NA-IONO/BiFE were studied by scanning electron microscopy and cyclic voltammetry. The influence of various experimental parameters upon the stripping lead signal at the GC/NA-IONO/BiFE was explored. Under the optimized conditions, the differential pulse voltammetric stripping response is highly linear over the 0.1–8.0 nM lead range examined (180 s preconcentration at ?1.2 V), with a detection limit of 0.044 nM and good precision (RSD = 5.4% at 0.5 nM). Also applicability to seawater samples was demonstrated at such modified electrode. The high selectivity of ionophore coupled with the excellent electrochemical characteristics of bismuth endow the GC/NA-IONO/BiFE a promising and robust tool for monitoring of trace lead rapidly and precisely.  相似文献   

5.
A highly efficient ultrasonic-assisted dispersive liquid–liquid microextraction (UA-DLLME) procedure coupled with gas chromatography–mass spectrometry was developed for simultaneous analysis of multiclass herbicides with endocrine-disrupting properties in environmental water samples. The parameters affecting the method’s extraction efficiency, such as the types and volumes of the extractant and dispersive solvents, sample pH, and salt concentration, were systematically optimized by response surface methodology based on central composite design to achieve excellent recoveries for multiclass herbicides. The final UA-DLLME protocol involved 115.6 µL of chloroform (extractant), 861.5 µL of ethanol (dispersive solvent), 5.0 mL of water samples, pH 10.0, and 4.3% NaCl solution. The performance of the developed UA-DLLME was compared with that of conventional solid-phase extraction (SPE). Under optimal extraction conditions, UA-DLLME exhibited a higher enrichment factor and greater sensitivity than SPE, with limits of detection and limits of quantification of 0.004–0.024 and 0.013–0.079 µg L?1, respectively, for seawater samples. The accuracy and precision of UA-DLLME were satisfactory for seawater samples spiked at three levels (0.2, 2.5, and 5.0 µg L?1). Average recoveries ranging from 82.3 to 101.8% were achieved, with relative standard deviations lower than 12.8%. The proposed analytical method was successfully applied to the simultaneous determination and quantification of 17 herbicides in environmental river and seawater samples.  相似文献   

6.

A heart-cut two-dimensional high-performance liquid chromatography method for enantiomeric determination of salbutamol, salmeterol and atenolol in urine is presented. It involves the use of two separations in a liquid chromatography–liquid chromatography achiral–chiral coupling. Target compounds were previously separated in a primary column (Kinetex™ HILIC, 2.6 μm, 150 × 2.1 mm I.D.) with a mixture of MeOH:ACN:ammonium acetate buffer (5 mM, pH 6) 90:5:5 (v/v/v) as mobile phase at a flow rate of 0.40 mL min−1. Enantiomeric separation was carried out by transferring peak of each compound through a switching valve to a vancomycin chiral column (Chirobiotic™ V, 2.6 μm, 150 × 2.1 mm I.D.) using MeOH:ammonium acetate buffer (2 mM, pH 4) 97:3 (v/v) as mobile phase at a flow rate of 0.50 mL min−1. Ultraviolet detection was done at 227 nm. The method was applied to determine target analytes in urine samples after enzymatic hydrolysis with β-glucuronidase from Helix pomatia, followed by a solid-phase extraction procedure using Isolute® HCX mixed-mode cartridges. Extraction recoveries ranged from 82 to 90 % in urine samples. Detection limits were 0.091–0.095 μg for each enantiomer of atenolol and between 0.058 and 0.076 and 0.18–0.14 μg for enantiomers of salbutamol and salmeterol, respectively (3 mL of urine). Linearity ranges were between 0.5 and 10 μg mL−1. Intraday and interday reproducibilities of enantiomeric ratio and enantiomeric fraction, expressed as relative standard deviation, were between 1.9 and 9.0 %. The optimized method was successfully applied to the analysis of urine samples obtained from excretion studies in volunteers and in freeze-dried urine samples, containing urinary components with MW < 10,000 and components with MW > 10,000, spiked with different amounts of studied drugs.

  相似文献   

7.
Formaldehyde is known as a highly toxic compound to humans and identified as a carcinogenic substance. In this study, Hantzsch reaction was utilized for the derivatization of trace amounts of formaldehyde in aqueous samples with acetylacetone in the presence of ammonia to form an extractable colored product named 3,5-diacetyl 1,4-dihydrolutidine (DDL) and its further extraction using two-phase hollow fiber liquid-phase microextraction. The main experimental variables affecting the extraction performance were investigated and optimized. Under the optimum conditions (sample volume 12 mL; reaction temperature 70 °C; ammonium acetate buffer solution 4 mL 0.1 mol L?1; acetylacetone 5 mL 0.15 mol L?1; solvent octanol, salt concentration 20% (w/v) NaCl; pH of donor phase 7.0; stirring speed 400 rpm and extraction time 30 min), the linear dynamic range, limit of detection (LOD as 3S b/m) and relative standard deviation (RSD %) of the proposed method were obtained as 5–250 μg L?1 (r 2 = 0.9979), 3.6 μg L?1 and 2.5%, respectively. Finally, the applicability of the proposed method was examined, and very good results were obtained. The results confirmed the applicability of the proposed method as a versatile, low-cost and sensitive preconcentration method for determination of low concentrations of formaldehyde in aqueous solutions.  相似文献   

8.
High speed counter-current chromatography in semi-preparative scale was used to separate and purify ergosta-4,6,8(14),22-tetraen-3-one from Ganoderma atrum, a famous traditional Chinese medicine. A two-phase solvent system composed of a mixture of n-hexane–ethanol–water (6: 5: 1, v/v/v) was used and the separation conditions were optimized. In a typical run in less than 400 min, 100 mg of samples can be separated to yield 14 mg of ergosta-4,6,8(14),22-tetraen-3-one with 99.1% purity. The structure of this compound was elucidated by UV, EI-MS, 1H NMR and 13C NMR.  相似文献   

9.
The reaction of various anthranilic acid derivatives or their esters with 4-oxotetrahydrothiophene-3-carbonitrile 2, 2-oxocyclopentanecarbonitrile (9, n = 1) or 2-oxocyclohexanecarbonitrile (9, n = 2) in ethanol under reflux conditions giving rise the formation of single products isolated in each case after simple filtration. The products were characterized as pyrazolo[1,5-a]quinazolin-5-ones 4 instead of the expected pyrazol-3-amines 3. These cascade condensation–intramolecular acylation processes generated in one-step reactions from simple starting materials novel heterocyclic scaffolds ready for further functionalization. The present synthetic protocol provides acceptable yields of new tetracyclic products in high purity.  相似文献   

10.
《Analytical letters》2012,45(14):2184-2192
A new procedure for trace tungsten W(VI) in soil by fluorescence quenching method coupled with cloud point extraction (CPE) as the separation-preconcentration method was described. The Triton X-100 CPE behavior of W(VI)-salicylfluorone (SAF)was investigated. Under the optimized conditions, the fluorescence quenched intensity (ΔF) was linearly with W(VI). The range of linear was 0.8 ~ 20.0 μg · L?1, the detection limit (DL) was 0.14 ng · mL?1 (3σ), the relative standard deviation 3.3% (c = 10.0 μg · L?1, n = 5) and the recovery was 101.0–102.2%. The proposed method applied to the analysis of W(VI) in certified reference materials and real samples.  相似文献   

11.
Shen  Mingyue  Xie  Mingyong  Nie  Shaoping  Wang  Yuanxing  Chen  Junhui  Li  Chang  Li  Jing 《Chromatographia》2008,67(11):999-1001

High speed counter-current chromatography in semi-preparative scale was used to separate and purify ergosta-4,6,8(14),22-tetraen-3-one from Ganoderma atrum, a famous traditional Chinese medicine. A two-phase solvent system composed of a mixture of n-hexane–ethanol–water (6: 5: 1, v/v/v) was used and the separation conditions were optimized. In a typical run in less than 400 min, 100 mg of samples can be separated to yield 14 mg of ergosta-4,6,8(14),22-tetraen-3-one with 99.1% purity. The structure of this compound was elucidated by UV, EI-MS, 1H NMR and 13C NMR.

  相似文献   

12.
《Analytical letters》2012,45(17):2493-2507
In this work, an improved hydride-generation atomic fluorescence spectrometry (HG-AFS) method for the determination of total arsenic (As) in wastewater and sewage sludge samples was applied. The samples were digested completely with mixtures of HNO3 and HClO4. Analytical conditions were studied and optimized through uniform experimental design U*10(108) combined with a single factor test. A mathematical model was established, and a quadratic polynomial stepwise regression analysis by using the DPS software was employed to obtain the factors that impact the fluorescence intensity. This technique is then combined with a single factor test. The optimized experimental conditions were obtained as follows: PMT voltage was 305 V, lamp current was 70 mA, KBH4 concentration was 2.0% (m/v), carrier liquid (HCl) concentration was 5% (v/v), carrier gas (Ar) flow rate was 300 mL min?1, and reaction acidity was 10% (v/v) HCl. The pre-reduction of all forms of As to As(III) was performed by using a mixed solution of 1% thiourea and 1% ascorbic acid. The content of total As was determined under the optimized experimental conditions. The detection limits for total As in wastewater and sewage sludge were 0.09 µg L?1 and 0.01 mg kg?1, respectively. The linear ranges were 0.24–100 µg L?1, and the recovery was 91.0–102.0%. The relative standard deviation (RSD, n = 5) for eleven replicate measurements of the certified reference materials containing 60.6 ± 4.2 µg L?1 As (certified sample of water) and 10.7 ± 0.8 mg kg?1 As (certified sample of soil) were 3.1% and 1.6%, respectively. The proposed method was validated by the analysis of certified reference materials and was successfully applied to the determination of total As in real samples of wastewater and sewage sludge with satisfactory results.  相似文献   

13.
《Analytical letters》2012,45(12):1805-1819
Abstract

Floated organic drop microextraction (FDME)–high performance liquid chromatography (HPLC) has been developed for extraction and determination of carbamate and benzoylurea insecticide residues from peach juice drink samples. The components were separated by a Diamonsil C18 instrument (5 µm, 250 mm × 4.6 mm i.d.). The mobile phase was a mixture of acetonitrile, methanol, and water (the ratio of volume was 18:70:12). Factors relevant to the extraction efficiency were studied and optimized. The methodology exhibited good linearity between 0.01 and 10.0 µg/mL with a correlation coefficiency of 0.9999. The average recovery of pesticides ranged from 88.49% to 101.86%. The relative standard deviations (RSDs) (n = 6) were 1.99–3.47%.  相似文献   

14.
《Analytical letters》2012,45(17):3210-3220
Abstract

A flow injection (FI) method is described for the determination of pirimicarb. It was found that an enhanced chemiluminescence (CL) signal is obtained when employing the luminol–H2O2–horseradish peroxidase (HRP) system. Under the optimum experimental conditions, the enhanced CL intensity was linear with the concentration 4.25–30.75 ng mL?1 (r = 0.997, n = 8) with a relative standard deviation of 0.99%, containing 12.75 ng mL?1 (n = 8). The limit of detection of the investigated compound was 0.12 ng mL?1. The method shows a moderate selectivity against other pesticides (Amitrole, Atrazine, 2,4,5-T, Dichlorprop, and Metamidophos).The proposed method was sensitive, simple, rapid, and successfully applied to the determination of pirimicarb when it is applied in freshwater; the mean recoveries were 98.3–118.5%.  相似文献   

15.
《Analytical letters》2012,45(16):2477-2486
A novel solid-phase microextraction (SPME) fiber was prepared by coating multiwalled carbon nanotube (MWCNTs) on a stainless steel wire, and its characteristics were studied. To evaluate the MWCNTs coating, the fiber was used for the extraction of some organochlorine pesticides (OCPs) from water samples by Headspace SPME (HS-SPME) mode. Potential factors affecting the extraction efficiency such as extraction time, extraction temperature, agitation, ionic strength, desorption temperature, and time were also optimized. Several experiments were carried out by water spiked with target compounds to evaluate the analytical characteristics of the proposed method under optimized conditions. The linearity was from 0.1 to 10 ug/L with the linear correlation coefficients (r) ranging from 0.9956 to 0.9995. The limits of detection (LOD, S/N = 3) for these pesticides were between 0.43 and 2.13 ng/L and the precision (RSD, n = 5) was 2.53–12.25%. When this method was applied for the spiked real river sample, the relative recoveries ranged from 72.4% to 134.7% for the tested OCPs.  相似文献   

16.
We developed a CZE method for simultaneous determination of pyridine-triphenylborane (PTPB) anti-fouling agent and its degradation products such as diphenylborinic acid (DPB), phenylboronic acid (MPB), and phenol in artificial seawater (ASW) with no extraction procedure. The ASW samples, in which 20 % (v/v) acetonitrile was added, were injected directly into the capillary using vacuum injection. As the background electrolyte, 60 mM sodium tetraborate adjusted to pH 9.8 was used. The LODs (S/N = 3) for PTPB, DPB, MPB, and phenol were, respectively, 55, 78, 126, and 30 μg L?1. The RSDs (n = 4) for analytes listed above were in the respective ranges of 2.7–5.7, 0.68–6.1, and 0.69–1.1 % for the peak area, peak height, and migration time. Simple degradation experiments were conducted to verify the usefulness of the proposed method. The PTPB samples dissolved in ASW were put in the open air, and rooms with and without light. The sample solutions were analyzed over time. We inferred that PTPB in ASW was more degraded by photolysis than by hydrolysis. The proposed CZE method has been demonstrated as a useful tool to elucidate the PTPB degradation process and its degradation products in ASW.  相似文献   

17.
The method developed for cesium concentration from large freshwater samples was tested and adapted for analysis of cesium radionuclides in seawater. Concentration of dissolved forms of cesium in large seawater samples (about 100 L) was performed using composite absorbers AMP-PAN and KNiFC-PAN with ammonium molybdophosphate and potassium–nickel hexacyanoferrate(II) as active components, respectively, and polyacrylonitrile as a binding polymer. A specially designed chromatography column with bed volume (BV) 25 mL allowed fast flow rates of seawater (up to 1,200 BV h?1). The recovery yields were determined by ICP-MS analysis of stable cesium added to seawater sample. Both absorbers proved usability for cesium concentration from large seawater samples. KNiFC-PAN material was slightly more effective in cesium concentration from acidified seawater (recovery yield around 93 % for 700 BV h?1). This material showed similar efficiency in cesium concentration also from natural seawater. The activity concentrations of 137Cs determined in seawater from the central Pacific Ocean were 1.5 ± 0.1 and 1.4 ± 0.1 Bq m?3 for an offshore (January 2012) and a coastal (February 2012) locality, respectively, 134Cs activities were below detection limit (<0.2 Bq m?3).  相似文献   

18.
Due to interesting therapeutic properties of 166Ho and the antineoblastic antibiotic, bleomycin (BLM), 166Ho-bleomycin (166Ho-BLM) was developed as a possible therapeutic compound. 166Ho chloride was obtained by thermal neutron irradiation (1 × 1013 n cm?2 s?1) of natural Ho(NO3)3 samples (specific activity = 3–5 GBq mg?1), dissolved in acidic media. At optimized conditions (room temperature, 12 h, 0.15–0.3 mg bleomycin for 74 MBq 166HoCl3) a radiochemical purity of 94–97% was obtained as shown by ITLC and HPLC (specific activity, 700–740 GBq mmol?1). Biodistribution studies of 166Ho chloride and 166Ho-BLM were performed in wild-type rats. The accumulation of the radiolabeled compound in lungs, liver and spleen demonstrates a similar pattern to the other radiolabeled bleomycins.  相似文献   

19.

We developed a CZE method for simultaneous determination of pyridine-triphenylborane (PTPB) anti-fouling agent and its degradation products such as diphenylborinic acid (DPB), phenylboronic acid (MPB), and phenol in artificial seawater (ASW) with no extraction procedure. The ASW samples, in which 20 % (v/v) acetonitrile was added, were injected directly into the capillary using vacuum injection. As the background electrolyte, 60 mM sodium tetraborate adjusted to pH 9.8 was used. The LODs (S/N = 3) for PTPB, DPB, MPB, and phenol were, respectively, 55, 78, 126, and 30 μg L−1. The RSDs (n = 4) for analytes listed above were in the respective ranges of 2.7–5.7, 0.68–6.1, and 0.69–1.1 % for the peak area, peak height, and migration time. Simple degradation experiments were conducted to verify the usefulness of the proposed method. The PTPB samples dissolved in ASW were put in the open air, and rooms with and without light. The sample solutions were analyzed over time. We inferred that PTPB in ASW was more degraded by photolysis than by hydrolysis. The proposed CZE method has been demonstrated as a useful tool to elucidate the PTPB degradation process and its degradation products in ASW.

  相似文献   

20.
A novel sequential injection method for the determination of nitrite at nanomolar level in seawater samples has been developed. The pink azo compound was formed based on the Griess reaction and quantitatively adsorbed onto a Sep-Pak C18 cartridge. The enriched azo compound was rinsed with water and ethanol (28%, v/v) in turn, and then eluted with an eluent containing 26.6% (v/v) ethanol and 0.108 mol L−1 H2SO4. Finally the azo compound was measured using a spectrophotometer at 543 nm. Under the optimized conditions, the linear calibration ranges were 0.71–42.9 nmol L−1 for a 150-mL sample and 35.7–429 nmol L−1 for a 15-mL sample. The relative standard deviation of 8 measurements was 1.44% for 14.3 nmol L−1 nitrite. For the 150 mL sample, the detection limit was estimated to be 0.1 nmol L−1. The throughput of the method was about 4 samples per hour. The proposed method has been successfully applied to the in-field determination of nanomolar concentrations of nitrite in seawater.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号