共查询到20条相似文献,搜索用时 15 毫秒
1.
《Analytical letters》2012,45(4):659-673
Abstract A mercury (II) ion‐selective polyvinyl chloride (PVC) membrane sensor based on ethylenediamine bisthiophenecarboxaldehyde (EDBT) as a novel nitrogen‐ and sulfur‐containing sensing material was successfully developed. The ionophore was produced through Schiff's base formation between ethylenediamine and 2‐thiophenecarboxaldehyde. These two reagents have the advantages of low cost and simple chemical compounds. Ortho‐nitro phenyl pentyl ether (o‐NPPE) as solvent and sodium tetraphenyl borate (NaTPB) as a lipophilic salt were chosen. The sensor exhibited a good linear response of 30.0±0.4 mV per decade within the concentration range of 10?7–10?2 and a detection limit of 7.0×10?8 mol L?1 Hg(II). The sensor showed good selectivity and fast response for the mercury (II) ion with respect to some alkali, alkaline earth, transition, and heavy metal ions. The EDBT–based sensor was suitable for aqueous solutions of pH range from 2.0 to 4.5. It can be used for about 3 months without any considerable divergence in potential. The formation constant of ionophore complex with Hg(II) ion was calculated by using the segmented sandwich membrane method. The structure of both the ionophore and its Hg(II) complex were examined using infrared spectra and elemental analysis. The proposed sensor was applied for the determination of Hg(II) content in some dental amulgum alloys and as an indicator electrode for potentiometric titration of Hg(II) ion with EDTA solution, as well as with I?, OH?, and IO3 ? ions. In addition, the solubility products of the previous ions were determined by using this sensor. 相似文献
2.
《Analytical letters》2012,45(10):1923-1938
Abstract In this work, for the first time, we introduce a highly selective and sensitive lutetium(III) micro‐sensor. N‐(2‐furylmethylene) pyridine‐2,6‐diamine (FPD) was used as a membrane‐active component to prepare a highly sensitive Lu(III)‐selective polymeric membrane microelectrode. Theoretical calculations for FPD, lutetium and some other metal ions were carried out and selectivity toward Lu(III) ions was confirmed. The best performance was achieved by a membrane composed of 32% PVC, 60% o‐nitrophenyloctyl ether, 4% potassium tetrakis (p‐chlorophenyl) borate (KTpClPB) and 4% FPD. The electrode exhibits a Nernstian response for Lu(III) ions over a particular concentration range (1.0×l0?11?1.0×10?6 mol l?1) with a slope of 20.5±0.2 mV decade?1. The detection limit is 3.0×10?11 mol l?1 while the sensor presents a response time of <10 s and a useful working pH range of 4.0–10.5. As a matter of fact, the proposed sensor discriminates relatively well for Lu(III) ions in compare to common alkali, alkaline earth, heavy metals and, specially, lanthanide ions. The sensor was successfully applied as an indicator electrode in a potentiometric titration of Lu(III) ions with EDTA. In addition, it was used for determination of lutetium in some soil samples where domestic devices were stored. The proposed sensor was evaluated for Lu(III) ions determination in some binary mixtures. 相似文献
3.
《Analytical letters》2012,45(8):1596-1609
Abstract An original highly selective and sensitive PVC membrane sensor, working as a Fe(III) ion selective electrode and using 4‐amino‐6‐methyl‐3‐methylmercapto‐1,2,4‐triazin‐5‐one (AMMTO) as an ionophore, has been developed. This cetain sensor demonstrated the following performance; a linear dynamic range between 1.0×10?6 and 1.0×10?1 M with a near Nernstian slope of 19.4±0.5 mV per decade; a detection limit of 6.8×10?7 M; characteristically, the best performance was obtained with a membrane composition of 30% poly(vinyl chloride), 65.5% nitrophenyl octyl ether, 2% sodium tetraphenyl borate and 2.5% AMMTO. Furthermore, the potentiometric response of the developed electrode is independent of the solution pH in the range of 2.2–4.8. The sensor possesses the advantages of short conditioning time, fast response time (<15 s) and, especially, great selectivity towards transition and heavy metal ions and some mono, di‐ and trivalent cations. The electrode can be used for at least 9 weeks without any considerable potential divergence. It was effectively used as an indicator electrode in the potentiometric titration of Fe(III) ions with EDTA and the direct determination of Fe3+ in different water samples. 相似文献
4.
Molecular switches that are controllable, reversible and readable at molecular level are an essential compo-nent of molecular electronics1 and chemical sensors.2-6 Of particular interest are the molecules which show dramatic and reversible changes in color and/or lumi-nescence in visible spectral region upon exposure to specific substrates. A number of chromophore- spacer-receptor systems that can selectively recognize specific guest molecules at their receptor site and pro-duce measurable col… 相似文献
5.
《Journal of Dispersion Science and Technology》2013,34(3-4):633-640
Abstract In this paper we report a novel DNA‐enrichment technology based on amino‐modified functionalized silica nanoparticles. The approach takes advantage of the amino‐modified silica nanoparticles that have been prepared in one step by the controlled synchronous hydrolysis of tetraethoxysilane and N‐(β‐amimoethyl)‐γ‐aminopropyltriethoxysilane in water nanodroplets of water‐in‐oil microemulsions. The functionalized silica nanoparticles display a positive surface charge at neutral pH due to the presence of amino groups on the surface of these nanoparticles. DNA‐enrichment has been realized in the form of nanoparticle–DNA complexes that is accomplished through electrostatic binding between the positive charge of the amino group and the negative charge of the phosphate groups of the nucleic acid. These nanoparticles have high affinity to bind DNA. The results show that 1 mg of nanoparticles can bind 97.2 µg of plasmid DNA with 4.3 kb. This novel DNA‐enrichment technology has been used successfully in gene delivery. 相似文献
6.
Ali Delibaş 《高分子科学杂志,A辑:纯化学与应用化学》2013,50(9):969-975
The new acrylamide monomer, N‐(4‐Bromophenyl)‐2‐methacrylamide (BrPMAAm) has been synthesized by reacting 4‐Bromoaniline with methacryloyl chloride in the presence of triethylamine(NR3) at 0–5°C. The radical‐initiated copolymerization of (BrPMAAm), with 2‐acrylamido‐2‐methyl‐1‐propanesulfonic acid (AMPS) has been carried out in dimethylformamide (DMF) solution at 70±1°C using 2,2′‐azobisisobutyronitrile (AIBN) as an initiator with different monomer‐to‐monomer ratios in the feed. The copolymers were characterized by FTIR, 1H‐ and 13C‐NMR spectroscopy. The copolymer composition was evaluated by nitrogen content (N for AMPS‐units) in polymers led to the determination of reactivity ratios. The monomer reactivity ratios for BrPMAAm (M1)‐AMPS (M2) pair were computed using the Fineman‐Ross (F‐R), Kelen‐Tüdös (KT) and Extended Kelen‐Tüdös (EKT) methods. These parameters were also estimated using a non‐linear computational fitting procedure, known as reactivity ratios error in variable model (RREVM). The mean sequence lengths determination indicated that the copolymer was statistically in nature. By TGA and DSC analyses, the thermal properties of the polymers have been studied. The antimicrobial effects of polymers were also tested on various bacteria, and yeast. 相似文献
7.
《Analytical letters》2012,45(5):902-916
Abstract A novel Pr(III) ion‐selective polyvinyl chloride (PVC) membrane sensor, based on N,N‐bis(α‐methylsalicylidene)diethylenetriamine (BMT) as a new ionophore, has been prepared and studied. The electrode showed good selectivity for Pr(III) ion with respect to most common cations, including alkali, alkaline earth, transition, and heavy metal ions. This electrode has a wide linear dynamic range from 1.0×10?6 to 1.0×10?2 M with a Nernstian slope of 19.8±0.2 mV per decade and a low detection limit of 6.5×10?7 M, in the pH range of 3.0–8.4, while response time was rapid (<15 s). As far as applications of the recommended sensor are concerned, first it was employed as an indicator electrode in the potentiometric titration of Pr(III) ions with EDTA. Second, it was effectively applied to the determination of concentration of Pr(III) ions in soil and sediment samples, and validation with CRMs. 相似文献
8.
Russian Journal of General Chemistry - A novel luminescence coordination polymer [Zn(hmph)(bibp)]n (1) has been synthesized by mild solvothermal method. It crystallizes in the orthorhombic space... 相似文献
9.
《Analytical letters》2012,45(12):2251-2266
Abstract A highly selective and sensitive poly(vinyl chloride) membrane electrode, using 4-4′-Methylenediantipyrine as an ionophore, has been prepared and examined as a Ba2+-selective electrode. The influence of the anion excluder (sodium tetraphenyl borate, NaTPB) and the effect of the plasticizers dibutyl phthalate (DBP), nitrobenzene (NB), and benzyl acetate (BA) were studied. The best performance was obtained with the sensor having a membrane composition (w/w) of (MAP, 2.0%), (PVC, 30%), (NB, 66%), (NaTPB, 2.0%) with a wide working concentration range of 1.0 × 10?6 to 1.0 × 10?2 M between the pH values of 3.4 and 10.6. Furthermore, a Nernstian slope of 29.7±0.3 mV/decade of activity was demonstrated with a response time of 15 s. The sensor could be used over a period of 2 months with no potential divergence, revealing a good selectivity for a broad variety of cations including alkali, alkaline earth, heavy and transition metals. Regarding the practical applicability of this sensing device, it was successfully applied for the Ba2+ ions detection in a lithophone pigment and as an indicator electrode in the potentiometric titration of the under study cations. 相似文献
10.
Xiao Xia CHEN Fang WANG Yan Xia XU Sheng Shui HU Depatment of Chemistry Wuhan University Wuhan State Key Laboratory of Transducer Technology Chinese Academy of Sciences Beijing 《中国化学快报》2006,17(4):496-498
A novel amperometric sensor for the determination of nitric oxide was developed by coating polythionine / nafion on a glassy carbon electrode. This sensor exhibited a great enhancement to the oxidation of nitric oxide. The oxidation peak currents were linear to the concentration of nitric oxide over the wide range from 3.6×10-7 to 6.8×10-5 mol.L-1, and the detection limit was 7.2×10-8 mol.L-1. Experimental results showed that this nitric oxide sensor possessed excellent selectivity and longer stability. NO releasing from rat kidney was monitored by this sensor. 相似文献
11.
《Analytical letters》2012,45(4):683-695
Abstract A highly selective and sensitive triiodide sensor based on a 2‐(((2‐(((E)‐1‐(2‐hydroxy phenyl) methylidine) amino) phenyl) imino) methyl) phenol with iodine (CTC) as membrane carrier was developed. The electrode revealed a Nernstian behavior over a very wide triiodide‐ion concentration range (5.0×10?8–1.0×10?2 M), and relatively low detection limit (3.0×10?8 M). The potentiometric response is independent of the pH of solution in the pH range of 3.0–10.0. The electrodes manifest advantages of low resistance, very fast response (<12 s), and most importantly, good selectivities relative to a wide variety of inorganic and organic anions, including iodide, bromide, chloride, fluoride, sulfite, sulfate, cyanide, thiocyanate, and acetate. In fact, the selectivity behavior of the proposed triiodide ion‐selective electrode shows great improvements compared to the previously reported electrodes for the triiodide ion. The proposed membrane sensor can be used for at least 6 months without any significant divergences in the potential. The electrode was successfully applied as an indicator electrode in the titration of triiodide with thiosulfate ion. 相似文献
12.
Microwave‐promoted reaction of 1,3‐disubstituted imidazolium salts with potassium thioacetate or potassium thiocyanate under solvent‐free conditions provided a rapid and efficient synthesis of 1,3‐disubstituted imidazole‐2‐thiones. 相似文献
13.
A general method for the preparation of 2‐(N‐Substituted)‐2‐imidazolines and 2‐(N‐Substituted)‐1,4,5,6‐tetrahydropyrimidines is described. These heterocycles can be synthesized from their respective anilines with 2‐chloro‐2‐imidazoline or 2‐chloro‐1,4,5,6‐tetrahydropyrimidine, generated in situ from imidazolidin‐2‐one and tetrahydropyrimidin‐2(1H)‐one activated by dimethyl chlorophosphate, in good to excellent yields. 相似文献
14.
《Analytical letters》2012,45(1):190-203
Abstract In this work, for the first time we report a highly selective and sensitive Gd(III) optical sensor based on immobilization of (Z)-N′-((pyridine-2-yl) methylene) thiophene-2-carbohydrazide (PMTC) on a triacetylcellulose membrane. This optode exhibits a linear range 5.0 × 10?8 to 2.0 × 10?5 M of Gd(III) ion concentration with a detection limit of 1.1 × 10?8 M. The response time of the newly designed optode was within 1–2 min, depending on the Gd(III) ion concentration. The response of the sensor is independent of the pH solution in the range of 2.0–9.0. It manifests advantages of low detection limit, fast response time, and most significant, very good selectivity with respect to a number of lanthanide ions (La, Ce, Sm, and Eu ions). The proposed sensor could be successfully regenerated with a thiourea solution. Its response was reversible and reproducible (RSD less than 1.3%). This optode was applied to the determination of Gd(III) in synthetic and real samples. 相似文献
15.
The reaction of the lithio derivative of novel polyethylene glycol (PEG)‐supported α‐phenylselenopropionate with aldehydes, followed by oxidation–elimination with 30% hydrogen peroxide and then treatment with sodium nitrite, formed PEG‐bound 2‐nitromethyl‐2‐alkenoates. Subsequent cleavage from the PEG efficiently afforded methyl (E)‐2‐nitromethyl‐2‐alkenoates in good yields and high purities. 相似文献
16.
A novel series of 1,3‐bis(2‐dihydrothiazolyl)thiaalkoxy‐p‐tert‐butylcalix[4]arenes generated by the reaction between 4,5‐dihydrothiazole‐2‐thiol and the different dibromide calix[4]aryl groups have been synthesized and structurally characterized by IR, 1H NMR, 13C NMR, and MS. From their analytical data, it was found that compounds 8, 9, and 10 had cone conformations, whereas compound 11 existed as a mixture conformation. To verify the structure of the synthetic compounds, a single‐crystal X‐ray structure of compound 8 was obtained. 相似文献
17.
Huilan Zhang Cheng Lu Shang Hongyuan Zhang Wen Zhang Aiping 《Russian Journal of Electrochemistry》2021,57(8):872-884
Russian Journal of Electrochemistry - A simply sensitive sensor based on a reduced graphene oxide–TiO2 nanocomposite modified glassy carbon electrode (RGO–TiO2/GCE) was developed for... 相似文献
18.
Ashok K. Singh A.K. Jain Anjali Upadhyay K.R.J. Thomas Prerna Singh 《International journal of environmental analytical chemistry》2013,93(8):813-827
The construction and performance characteristics of polymeric membrane electrodes based on neutral ionophore 5,5′‐(5,5′‐(benzo[c][1,2,5]thiadiazole‐4,7‐diyl)bis(thiophene‐5,2‐diyl))bis‐(N1,N1,N3,N3‐tetraphenylbenzene‐1,3‐diamine) (L) for quantification of cadmium ions, are described. Effect of plastisizers dibutylpthalate (DBP), tri‐n‐butylphosphate (TBP), dioctylpthalate (DOP), o‐nitrophenyloctyl ether (o‐NPOE), 1‐chloronaphthalene (CN) and ionic additives sodium tetraphenylborate (NaTPB), potassium tetrakis p‐(chlorophenyl)borate (KTpClPB) was studied. Best performance was obtained with the membrane having a composition L?:?PVC?:?DBP?:?NaTPB?≡?2?:?37?:?59?:?2 (w/w; mg). The membrane electrode exhibits Nernstian response in the concentration range 6.3?×?10?8 to 1.0?×?10??1?mol?L?1 with detection limit 3.6?×?10?8?mol?L?1 and is not affected by H+ ions over a wide pH range 3.0–10.0. The electrode possess a fast response time of 10?s and shelf life period of 3 months. The analytical utility of the proposed electrode has demonstrated by its application in the determination of cadmium in water, medicinal plants and soil samples. It could also be used successfully as an indicator electrode in the potentiometric titration of Cd2+ with EDTA (ethylenediaminetetraacetic acid). 相似文献
19.
20.
Tarek M. Abou Elmaaty 《合成通讯》2013,43(16):2281-2285
Starting from indan‐1,3‐dione, a novel two‐step synthesis of the oxepine derivatives 5a,b and the pyran derivatives 7 and 8 under very simple reaction conditions is described. 相似文献