首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The present paper deals with a method of solid-phase extraction of tocopherol acetate (TA, 49.6 microg/g) from emulsified nutritional supplements, which contains 50 kinds of compounds, followed by high-performance liquid chromatography (HPLC) with fluorescence detection The TA concentration is 5 to approximately 100,000 times lower than that of other compounds in the samples. Measuring the loading capacity of the larger amounts of vegetable oil onto the Bond Elut C18 cartridge was examined for the complete retention of smaller level of TA. A sample solution was applied to a solid-phase extraction cartridge and then TA was eluted by acetonitrile followed by HPLC. This method was suitable for the determination of TA in emulsified nutritional supplements. The proposed method was simple, rapid (analysis time: ca. 15 min), sensitive [detection limit: ca. 0.1 ng per injection (100 microl) at a signal-to-noise ratio of 3:1], and reproducible (relative standard deviation: ca. 2.5% (n=5)). The calibration graph of TA was linear in the range of 0.1 to 100 ng per injection (100 microl). Recovery of TA was over 90% by the standard addition method.  相似文献   

2.
Retinol palmitate (vitamin A, 73.3 microg/g) in an emulsified nutritional supplement was determined by solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) with fluorescence detection (excitation 350 nm, emission 480 nm) using monosodium L-glutamate as a dissolving agent to obtain higher recovery of vitamin A from the emulsified sample solution. A Bond Elut C2 cartridge (500 mg) was chosen for SPE after comparison with 16 other types. A sample solution was applied to a conditioned Bond Elut C2 cartridge and then vitamin A was eluted with ethanol followed by HPLC. The proposed method was simple, rapid (sample preparation time by SPE: ca. 8 min, retention time: ca. 8 min), sensitive [detection limit: ca. 0.1 pg/injection (100 microl) at a signal-to-noise ratio of 3:1], highly selective and reproducible (relative standard deviation (RSD): ca. 2.9% (n = 5), between-day RSD ca. 3.7 (5 days). The recovery of vitamin A was over 90% by the standard addition method.  相似文献   

3.
Determination of small amounts of vitamin K1 (0.8 microg/g) in nutritional supplements with high fat content (20 mg/g) was performed by solid-phase extraction and high-performance liquid chromatography (HPLC) with fluorescence detection after reduction on a platinum oxide catalyst. The concentration ratio of plant oils to vitamin K1 (0.8 microg/g) was about 25,000:1. A sample solution was applied to a solid-phase extraction cartridge and vitamin K1 was eluted with ethanol, followed by HPLC. The proposed method was simple, rapid (analysis time: ca. 12 min), sensitive [detection limit: ca. 0.1 pg per injection (100 microl) at a signal-to-noise ratio of 3:1], highly selective and reproducible [relative standard deviation: ca. 1.3%. (n=5)]. The calibration graph of vitamin K1 was linear in the range of 0-2 pg per injection (100 microl). Recovery of vitamin K1 was over 90% by the standard addition method.  相似文献   

4.
Determination of small amounts of the fat-soluble species Vitamin A (VA) (2.5 μg/g) and β-carotene (9 μg/g) from emulsified nutritional supplements containing 50 kinds of co-existing compounds and a fat content between 2000 and 8000 times higher was performed by solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) with fluorescence detection set at ex. 350 nm and em. 480 nm, and visible detection at 450 nm using an Inertsil ODS 80A (5 μm) analytical column. Mobile phases of methanol-ethanol (50:50) and acetonitrile-ethanol (70:30) were used for the both vitamins. A Bond Elut C18 cartridge was chosen for SPE after comparison with eight other types of SPE cartridge. Retention time of VA and β-carotene was 7 and 8 min, respectively, giving a limit of detection of ca. 0.1 ng per injection at a signal-to-noise ratio 3:1. Recoveries of VA and β-carotene were over 90% by the standard addition method. Relative standard deviation of VA and β-carotene were ca. 2.9 (n=5) and 2.3% (n=5), respectively.  相似文献   

5.
A high-performance liquid chromatographic (HPLC) method for determining glycarbylamide (GB) in chicken tissue was developed. GB was extracted with acetonitrile, followed by solid-phase extraction cleanup using a Bond Elut cartridge column with neutral alumina. After the extract had been evaporated to dryness, the residue was dissolved in 1.0 mL 0.1 N sodium hydroxide. Then 1.0 mL 0.1 M potassium dihydrogen phosphate solution was added to it. HPLC separation was done on a 250 x 4.6 mm id TSK-GEL ODS 80 column with 0.05M potassium dihydrogen phosphate as the mobile phase. Ultraviolet detection was done at a wavelength of 260 nm. The calibration curve of standard GB solutions was linear between 0.16 and 3 micrograms/mL (correlation coefficient, r = 0.999). The recovery of GB from chicken muscle spiked at 0.8 microgram/g was 88.6 +/- 2.3% (mean +/- standard deviation, n = 5), and the lower limit of determination was 0.05 microgram/g in chicken muscle.  相似文献   

6.
A new procedure is developed for the extraction of polycyclic aromatic hydrocarbons (PAHs) from the particulate phase of cigarette smoke. The procedure applies solid-phase extraction using a Bond Elut CH cartridge as a sample preparation step. The efficiency of the cleanup procedure is verified using a gas chromatographic (GC)-high-resolution mass spectrometric (MS) technique, proving that no interference occurs in the PAHs' determination. The efficient cleanup allows GC detection using either high- or low-resolution MS detection. Enhanced sensitivity is obtained using GC-MS and selected ion monitoring. This new technique has several advantages over other reported techniques. The method is simple and robust and has good repeatability and accuracy. The estimated detection limit is 0.1 ng/cigarette for benzo[a]pyrene. In addition to that, the recovery from the smoke pad in which the smoke is collected is approximately 97% for all PAHs. Results for the PAH analyses for 1R5F, 1R4F, and 1R3 Kentucky reference cigarettes are reported in this study. These results provide useful evidence for clarifying the controversy about previously reported data.  相似文献   

7.
A simple, rapid, and reliable method for the determination of residual sulphonamide antibacterials (SAs) (sulfadiazine, sulfamerazine, sulfadimidine, sulfamethoxypiridazine, sulfisozole, sulfamonomethoxine, sulfamethoxazole, sulfisoxazole, sulfadimethoxine, and sulfaquinoxaline) in animal liver and kidney was developed using a combination of clean-up on a Bond Elut PSA cartridge and HPLC with UV detection. The SAs were extracted with ethyl acetate and then dissolved in 5 ml of 50 v/v% ethyl acetate-n-hexane after being evaporated to dryness. For clean-up of the crude sample, the resuspended extract was applied to a Bond Elut PAS (primary/secondary amine cartridge), and then SAs were eluted from the cartridge using 5 ml of 20 v/v% acetonitrile-0.05 M ammonium formate before being analysed by HPLC. Recoveries of the SAs at the levels of 0.5 and 0.1 microg/g were 70.8-98.2%, the rerative standard deviation were less than 7.0%, and the detection limits were 0.03 microg/g. The present analysis method of SAs in animal kidney and liver using HPLC with a clean-up procedure was demonstrated to be highly applicable to the direct LC-MS-MS analysis without any modification.  相似文献   

8.
The analytical method described here provides the appropriate sensitivity and selectivity for the determination of unlabelled hydroxypropyl-beta-cyclodextrin as a parenteral carrier in pharmaceutical formulations. The method may also be used in clinical trials evaluating the fate and pharmacokinetic profile of this compound, which was isolated from the biological matrix by solid-phase extraction with Bond Elut C18 cartridges. The lack of uniformity of the product was circumvented by the use of a size-exclusion chromatographic column. An indirect colorimetric complexation method was used for detection. The detection limit was 0.1 micrograms per 2 ml of biological fluid and the extraction recovery was sufficient (78%).  相似文献   

9.
A solid-phase extraction (SPE) method for sample clean-up followed by a reversed-phase high-performance liquid chromatography (HPLC) procedure for the assay of five antidepressant drugs (trazodone, doxepin, desipramine, maprotiline and imipramine) is reported. The drugs were recovered from plasma buffered at a suitable pH using C18 Bond-Elut cartridges and mixtures of methanol-aqueous buffer as washing and elution solvents. The recoveries of the drugs using other sorbent materials (C8, C2, cyclohexyl, cyanopropyl and phenyl Bond Elut and copolymer HLB waters cartridges) were also examined. The selectivity of SPE was examined by using spiked plasma samples and the CH cartridge gave rise to the cleanest extracts. Cyclohexyl cartridges were conditioned successively with 2 ml of methanol and 1 ml of acetic acid-sodium acetate buffer (0.1 M, pH 4.0). Plasma sample was buffered at pH 4.0 and then applied to the sorbent. The washing step was performed subsequently with 1.5 ml of acetate buffer (0.1 M, pH 4.0), 100 microl of acetonitrile and 1 ml of methanol-acetate buffer (30:70, v/v). Finally, the analytes were eluted with 0.5 ml of methanol-acetate buffer (70:30, v/v). The extract was evaporated to dryness, reconstituted in mobile phase, and chromatographed on a reversed-phase C18 column with ultraviolet detection at 215 nm. The recoveries of trazodone, doxepin, desipramine, maprotiline and imipramine from spiked plasma samples using the CH cartridge were 58 2, 84 3, 83 3, 83 3 and 82 2%, respectively. The within-day and between-day repeatabilities were lower than 6% and 9%, respectively. The linearity of calibrations for the five antidepressants was between 0.005 and 2 microg/ml. The limits of detection were 1 ng/ml for trazodone, doxepin and desipramine and 2 ng/ml for maprotiline and imipramine.  相似文献   

10.
The results of validation of a method for the analysis of free and bound phenolics in wine and grapes are presented. Wine and grape extracts are fractionated by automated solid-phase extraction on Bond Elut PPL cartridges to give free and bound phenolic fractions. Bound fractions are subjected to acid hydrolysis, and the phenolics released are recovered by solid-phase extraction on Bond Elut PPL cartridges. The fractions are further purified by automated solid-phase extraction on Bond Elut silica cartridges. After derivatisation to form trimethylsilyl ethers, the phenolics are determined by gas chromatography–mass spectrometry with selected ion monitoring. The method is suitable for robust, high-throughput monitoring of the concentrations of phenolics that can affect the palatability of wine.  相似文献   

11.
A new method for the high performance liquid chromatographic (HPLC) determination of N-(N-acetyl-L-methionyl)-O,O-bis(ethoxycarbonyl)dopamine (TA-870), a dopamine prodrug, in biological fluid has been developed. In order to measure with an electrochemical detector (ECD), TA-870 was passed first through an immobilized carboxylesterase column to be converted to the electrochemically active deethoxycarbonylated TA-870 (DEC-TA-870). The properties of this carboxylesterase immobilized on Sepharose 4B were examined by this flow injection system. Hydrolysis of TA-870 with this immobilized carboxylesterase was a maximum at pH 7-8 and 50 degrees C, and the activity decreased in the presence of organic solvent such as acetonitrile. For the determination of TA-870 in biological fluids, an HPLC-immobilized enzyme-ECD system using a column-switching technique was developed. The blood was deproteinized with ethanol, and TA-870 in the ethanol extracts was adsorbed in Bond Elut C18. The dichloromethane eluate from Bond Elut C18 was injected into the HPLC system. The HPLC apparatus was composed of three pumps, two separation columns (LiChrosorb Si 60 and mu Bondasphere), a trap column (Bond Elut), an enzyme column, ECD and the column-switching system. The calibration curve for TA-870 in blood was linear in the range from 2 to 200 ng/mL. This new assay method might be useful also for the determination of other catechol ester compounds.  相似文献   

12.
A specific and sensitive gas chromatographic-mass spectrometric method for the determination of three metabolites of the angiotensin-converting enzyme inhibitor, imidapril, in plasma and urine was developed. The metabolites were isolated from plasma and urine using a Bond Elut C18 solid-phase extraction cartridge. The isolated metabolites were converted to sensitive derivatives by pentafluorobenzyl bromide and heptafluoro-n-butyric acid anhydride. Following derivatization, the sample solutions were analysed by wide-bore column gas chromatography-mass spectrometry with multiple ion detection. The detection limits of the three metabolites were each 1 ng/ml in plasma and 5 ng/ml in urine. Analysis of the spiked plasma and urine samples demonstrated the good accuracy and precision of the method. This method was very useful for use in pharmacokinetic and bioavailability studies of the three metabolites of imidapril in humans.  相似文献   

13.
The metabolism of (+/-)fenfluramine, 1-(m-trifluoromethylphenyl)-2-N-ethylpropane, an anoretic agent, was investigated in humans. The analysis method was based on the use of ion-exchange resin extraction, solid-phase purification on the Bond Elut1M C8 cartridge, gradient elution high-performance liquid chromatography, enzymic hydrolysis of conjugates, further purification by Bond Elut C8 cartridge, derivatisation and capillary column gas chromatography-mass spectrometry (GC-MS). After administration of a 1 mg kg-1 oral dose, four metabolites plus unchanged fenfluramine were recovered in the 0-24 h urine from human volunteers and characterised by GC-MS. In the conjugated form, fenfluramine, norfenfluramine and m-trifluoromethylhippuric acid were detected by GC-MS. In the aglycone form, the major metabolite, 1-(m-trifluoromethylphenyl)-1,2-propane diol (fenfluramine diol), was monitored using GC-MS. The mass spectral characteristics of the m-trifluoromethylhippuric acid methyl ester, 1-(m-trifluoromethylphenyl)-1,2-propane ditrifluoracetate derivatives and the norfenfluramine and fenfluramine free base obtained under electron-impact ionization are presented. The metabolism of fenfluramine is discussed including a metabolic pathway in man accounting for the formation of its biotransformation products.  相似文献   

14.
The possibility of using monosodium L-glutamate (MSG) (20 mM MSG, pH 2.1) in the mobile phase for the determination of ascorbic acid (AA) in foods by high-performance liquid chromatography (HPLC) with electrochemical detection was examined. The hydrodynamic voltammogram of AA and the background current were also examined. The applied potential was set at 400 mV versus an Ag/AgCl reference electrode. It was demonstrated that MSG was a useful mobile phase for the determination of AA in foods. This paper also examines the stability of AA under various conditions in order to optimize HPLC conditions and the pre-run sample stabilization. The proposed method is simple, rapid (analysis time: approximately 6 min), sensitive (detection limit: approximately 0.1 ng per injection (5 microl) at a signal-to-noise ratio of 3), highly selective and reproducible (relative standard deviation: approximately 2.5%, n=7). The calibration graph of AA was linear in the range 0.1-50 ng per injection (5 microl). Recovery of AA was over 90% by the standard addition method.  相似文献   

15.
A rapid high-performance liquid chromatographic procedure has been developed for the assay of 1,4-dioxane in cosmetic products. After solid-phase extraction, using Bond Elut CN and Bond Elut C18 cartridges, samples were analysed directly on a LiChrospher CH-8 reversed-phase column with spectrophotometric detection at 200 nm and acetonitrile - water as eluent. Recovery of 1,4-dioxane from different cosmetic matrices was between 81.5 and 90.1% in the 30-90 microgram g(-1) range. The minimum quantifiable amount was 6.5 microgram g(-1). The method is simple, reproducible and specific and is suitable for routine analyses of commercial cosmetics.  相似文献   

16.
The behavior and main characteristics of a commercial immunosorbent (IS) cartridge for the solid-phase extraction of phenylureas are determined in this work. The measured capacity for the analyte-antigen (isoproturon) in a new cartridge is 215 ng and, after more than 100 adsorption-desorption cycles, the remaining capacity still is approximately 70 ng, demonstrating the good stability of the bonded antibody and the interesting possibility of extensive cartridge reuse. Only isoproturon and diuron are specifically retained in this sorbent. The weak nonspecific retention of other pesticides, including other phenylureas, can be avoided by increasing the sample volume during the loading step. Thus, a very selective and sensitive method for the determination of isoproturon and diuron in natural and potable waters is developed by loading a 50-mL sample adjusted to pH 7.4 in the IS cartridge, eluting with methanol-water (60:40, v/v), and analyzing the eluate by high-performance liquid chromatography with UV detection. The clean chromatograms, low detection limits (approximately 0.1 micro g/L), and good precision (< 5%) obtained with this rapid and simple method demonstrate that immunoaffinity extraction can be an excellent alternative for sample preparation in the environmental monitoring of particular pesticides in water matrices.  相似文献   

17.
This work presents a modified method to analyze polar and water-soluble naphthalene monosulfonic acid (NS) isomers in industrial effluents and river water samples. The method involves extraction of samples by a styrene-divinylbenzene copolymer solid-phase extraction cartridge, and on-line derivatization in the GC injection port using a large-volume (10 microl) sample injection with tetrabutylammonium salts. The analytes were then identified and quantitatively determined by GC-MS. The large-volume injection-port derivatization technique provides sensitivity, fast and reproducible results for NS isomers, to quantitation at 0.05 microg/l in 200 ml of water sample. Enhanced extracted mass chromatograms of molecular ion and [M-56]+ ion of butylated NS isomers by electron impact ionization MS allows us to determine residues at trace levels in environmental samples. Recoveries of the NS isomers in spiked water samples ranged from 70 to 82% with RSDs around 10%. Naphthalene-2-sulfonic acid was found as a major pollutant and propagated in surface water and industrial effluents.  相似文献   

18.
A simple and rapid analytical method of five phenolic acids, gallic, chlorogenic, caffeic, ellagic and ferulic acid, which are naturally occurring bioactives, were determined in fruit juices by isocratic LC using photodiode array UV detection. The sample was pre-treated by solid-phase extraction (a combination of Sep-Pak Plus tC18 and Bond Elut PSA).  相似文献   

19.
A molecularly imprinted polymer (MIP) prepared using caffeine, as a template, was validated as a selective sorbent for solid-phase extraction (SPE), within an automated on-line sample preparation method. The polymer produced was packed in a polypropylene cartridge, which was incorporated in a flow system prior to the HPLC analytical instrumentation. The principle of sequential injection was utilised for a rapid automated and efficient SPE procedure on the MIP. Samples, buffers, washing and elution solvents were introduced to the extraction cartridge via a peristaltic pump and a multi-position valve, both controlled by appropriate software developed in-house. The method was optimised in terms of flow rates, extraction time and volume. After extraction, the final eluent from the extraction cartridge was directed to the injection loop and was subsequently analysed on HPLC. The overall set-up facilitated unattended operation, operation and improved both mixing fluidics and method development flexibility. This system may be readily built in the laboratory and can be further used as an automated platform for on-line sample preparation.  相似文献   

20.
A reversed-phase isocratic high-performance liquid chromatographic method for the determination of total teicoplanin in plasma is reported. The method developed uses a bracketing injection technique in conjunction with large injection volumes on a 1 mm diameter column to form a limited injection-generated gradient. The chromatography yields adequate resolution among all the major components for individual quantitation and also allows quantitation of total teicoplanin in plasma using ultraviolet detection. Pretreatment is by solid-phase extraction which uses C8 Bond Elut cartridges and gives effective clean up from endogenous materials. The method offers a faster and simplified means to determine total teicoplanin in plasma than those previously reported, and has a detection limit of 50 ng/ml.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号