共查询到20条相似文献,搜索用时 0 毫秒
1.
邵明 陈宏芳 李澄 汪晓莲 黄胜利 李洁 阮丽娟 伍健 许咨宗 汪兆民 G.Eppley W.J.Llope F.Geurts J.Schambach 《中国物理 C》2004,28(7):733-737
多气隙电阻板室(MRPC)飞行时间探测器模型从2003年2月开始在美国布鲁克海文国家实验室(BNL)的AGS束流上顺利完成了为期10周的测试(共28个MRPC模块168路读出,其中12个模块即72个读出道配置了读出电子学).实验表明工作气体的选择对MRPC的工作性能有很大影响.测量了几种不同成分的混合气体(A)90%C2H2F4+5%iso-C4H10+5%SF6、(B)95.3%C2H2F4+47%iso-C4H10及(C)100%C2H2F4下MRPC探测效率和时间分辨等特性的变化,并给出了相应条件下的流光信号几率 相似文献
2.
3.
4.
Six-gap resistive plate chamber (MRPC) prototypes with semiconductive glass electrodes (bulk resistivity~1010.cm) were studied for suitability in time-of-flight (TOF) applications at high rates. These studies were performed using a continuous electron beam of 800 MeV at IHEP and an X-ray machine. Time resolutions of about 100 ps and efficiencies larger than 90% were obtained for flux densities up to 28 kHz/cm2. 相似文献
5.
Six-gap resistive plate chamber (MRPC) prototypes with semiconductive glass electrodes (bulk resistivity ~ 10^10Ω·cm) were studied for suitability in time-of-flight (TOF) applications at high rates. These studies were performed using a continuous electron beam of 800 MeV at IHEP and an X-ray machine. Time resolutions of about 100 ps and efficiencies larger than 90% were obtained for flux densities up to 28 kHz/cm^2. 相似文献
6.
Fu-Yue Wang Yi Wang Bo Xie Dong Han Peng-Fei L& uuml Bao-Hong Guo Yuan-Jing Li 《中国物理C(英文版)》2016,40(11):116006-116006
The Compact Muon Solenoid (CMS) at LHC intends to use a high rate trapezoid MRPC for the muon system upgrade, but the size of the MRPC is limited by the dimensions of low resistivity glass. We have designed a prototype of a large MRPC in which the electrodes are developed by gluing two pieces of glass plates. Simulation of the weighting field and cosmic ray test shows that the efficiency of the glued MRPC is higher than 96% and the time resolution is better than 71 ps. 相似文献
7.
8.
《中国物理C(英文版)》2016,(5)
With the constant increase of accelerator luminosity, the rate requirements of MRPC detectors have become very important, and the aging characteristics of the detector have to be studied meticulously. An online aging test system has been set up in our lab, and in this paper the setup of the system is described and the performance stability of a high-rate MRPC studied over a long running time under a high luminosity environment.The high rate MRPC was irradiated by X-rays for 36 days and the accumulated charge density reached 0.1 C/cm~2.No obvious performance degradation was observed for the detector. 相似文献
9.
10.
11.
In order to test the performance of detector prototypes in a laboratory environment, we design and build a large area (90 cm×52 cm) test platform for cosmic rays based on a well-designed Multi-gap Resistive Plate Chamber (MRPC) with excellent time resolution and a high detection efficiency for minimum ionizing particles. The time resolution of the MRPC module used is tested to be ~80 ps, and the position resolution along the strip is ~5 mm, while the position resolution perpendicular to the strip is ~12.7 mm. The platform constructed by four MRPC modules can be used for tracking cosmic rays with a spatial resolution of ~6.3 mm, and provide a reference time ~40 ps. 相似文献
12.
13.
M. M. Devi N. K. Mondal B. Satyanarayana R. R. Shinde 《The European Physical Journal C - Particles and Fields》2016,76(12):711
The multigap resistive plate chambers (MRPCs) are gas ionization detectors with multiple gas sub-gaps made of resistive electrodes. The high voltage (HV) is applied on the outer surfaces of outermost resistive plates only, while the interior plates are left electrically floating. The presence of multiple narrow sub-gaps with high electric field results in faster signals on the outer electrodes, thus improving the detector’s time resolution. Due to their excellent performance and relatively low cost, the MRPC detector has found potential application in time-of-flight (TOF) systems. Here we present the design, fabrication, optimization of the operating parameters such as the HV, the gas mixture composition, and, performance of six-gap glass MRPC detectors of area 27 cm \(\times \) 27 cm, which are developed in order to find application as trigger detectors, in TOF measurement etc. The design has been optimized with unique spacers and blockers to ensure a proper gas flow through the narrow sub-gaps, which are 250 \(\upmu \)m wide. The gas mixture consisting of R134A, Isobutane and SF\(_{6}\), and the fraction of each constituting gases has been optimized after studying the MRPC performance for a set of different concentrations. The counting efficiency of the MRPC is about 95% at 17.9 kV. At the same operating voltage, the time resolution, after correcting for the walk effect, is found to be about 219 ps. 相似文献
14.
15.
抛光垫是化学机械抛光的重要组成部分,其磨损的非均匀性对被加工工件面型精度和抛光垫修整有重要影响。基于直线摆动式抛光方式,研究了抛光过程中抛光垫与工件的相对运动,建立了抛光垫磨损模型,分析了抛光工艺参数对抛光垫磨损及均匀性的影响。研究结果表明,工件与抛光垫的转速比为1.11,正弦偏心直线摆动形式,摆动幅度系数为2,摆动频率系数在0.1~0.2之间,抛光垫表面磨损更均匀,并根据抛光垫表面磨损特性优化了抛光垫形状。优化的抛光垫具有更好的面型保持性,延长了修整间隔,为抛光工艺设计提供理论指导。 相似文献
16.
In this paper, we proposed a novel quantum secure direct communication scheme with one-time pad in stabilizer formalism. Based
on the reuse of qubit sequence, an efficient secure communication of secret messages without first producing a shared secret
key can be achieved. One hence may find that the amount of private key needed for quantum communication is smaller than that
in the general case. Therefore, the present protocol which is feasible with the present-day techniques may be applied to quantum
communication with short-length encoding. 相似文献
17.
M. I. Nasser M. A. Moharram 《International Journal of Infrared and Millimeter Waves》1989,10(1):73-82
In this work, the temperature dependence of the intensities of the IR absorption bands corresponding to the fundamental vibrations, overtones and combination frequencies of diphenyl is presented. A thorough discussion of the interpretation of the fundamental modes of vibration has been made on the basis of the temperature dependence of the intensities of these absorption bands.The structure of the diphenyl molecule has been the subject of numerous investigations. Despite a considerable amount of work on the Raman(1), IR(3,4,5) and ultraviolet (2) spectra, the assignment of the fundamental frequencies has not yet been established with certainty, Some assistance can be obtained from the temperature dependence of the IR spectrum of this material. 相似文献
18.
John W. Daily 《Journal of Quantitative Spectroscopy & Radiative Transfer》1977,17(3):339-341
The effect of turbulent temperature fluctuations on line-reversal temperature measurements is examined in the thin gas, small fluctuation limit. It is shown that in this limit the fluctuations have no effect on the time average results. Only in case of a spacially uniform temperature can the fluctuating component of the temperature be directly measured. For the case of a spacially uniform mean temperature, a spacial average of the fluctuating component can be measured. For the completely non-uniform case, only a complex spacial average of the fluctuating and mean temperatures can be measured. 相似文献
19.
20.
Qingdian Kong Lianke Song Handong Peng Hailong Wang Lihua Kong Congmin Wang Lan Wang 《中国光学快报(英文版)》2008,6(11)
In order to reduce the error caused by the change of temperature, the relation between three-in-one composite compensator's phase retardation and temperature is calculated according to the characteristic of multiple-order quartz wave-plate. The results show that the influence on phase retardation increases with the increase of temperature and order of wave-plate. The phase retardation and the angle that the second wave-plate rotates are in a linear relationship in certain ranges. However, there is also some regularity in nonlinear areas which can be determined by theoretical calculation. The calculated result is well in agreement with experiments. 相似文献