A selective reversed phase liquid chromatography/mass spectrometry (LC/MS(n)) method is described for the identification of erythromycin impurities and related substances in commercial erythromycin samples. Mass spectral data are acquired on a LCQ ion trap mass spectrometer equipped with an electrospray interface operated in positive ion mode. The LCQ is ideally suited for identification of impurities and related substances because it provides on-line LC/MS(n) capability. Compared with UV detection, this hyphenated LC/MS(n) technique provides as a main advantage efficient identification of novel substances without time-consuming isolation and purification procedures. Using this method four novel related substances were identified in commercial samples.  相似文献   

2.
A selective reversed phase liquid chromatography/mass spectrometry (LC/MS(n)) method is described for the identification of related substances in commercial gramicidin samples. Mass spectral data are acquired on an LCQ ion trap mass spectrometer equipped with an electrospray interface operated in the positive and the negative ion mode. The LCQ is ideally suited for identification of related substances because it provides on-line LC/MS(n) capability. Compared with UV detection the main advantage of this hyphenated LC/MS(n) technique is the efficient identification of novel related substances without time-consuming isolation and purification procedures. Using this method four novel related substances were separated and identified in a commercial sample.  相似文献   

3.
A selective reversed-phase liquid chromatography/mass spectrometry (LC/MS(n)) method was developed for the characterization of components of the semi-synthetic macrolide clarithromycin. Mass spectral data were acquired online on a LCQ ion trap mass spectrometer equipped with an electrospray ionization source operated in the positive ion mode. One unknown compound was structurally elucidated and two other unknowns were characterized using the MS/MS and MS(n) collision-induced dissociation spectra of reference substances as interpretative templates, combined with knowledge of the nature of functional group fragmentation behaviour. Given the importance attached to the identification of impurities of unknown identity in pharmaceutical substances, this study is useful for companies producing clarithromycin.  相似文献   

4.
A selective reversed-phase liquid chromatography/mass spectrometry (LC/MS(n)) method is described for the identification of azithromycin impurities and related substances in commercial azithromycin samples. Mass spectral data are acquired on an LCQ ion trap mass spectrometer equipped with an atmospheric pressure chemical ionization interface operated in positive ion mode. The LCQ provides on-line LC/MS(n) capability, making it ideally suited for identification purposes. In comparison with UV detection, this hyphenated technique provides as its main advantage efficient identification of novel substances without time-consuming isolation and purification procedures. Using this technique, six novel related substances detected in commercial azithromycin samples have been studied.  相似文献   

5.
Product ions obtained by tandem mass spectrometry (MS/MS) are quite effective for the amino acid sequencing of linear peptides. However, in the case of cyclic peptides, the fragmentation pattern is complicated because the cleavages occur randomly and product ions are generated as a(n), b(n), c(n), x(n), y(n) and z(n) series ions; therefore, the authors have never obtained sufficient sequence information. In order to overcome this problem, we applied ion trap liquid chromatography/multi-stage mass spectrometry (LC/MS(n)) and characterized the product ions obtained from anabaenopeptins and aeruginopeptins as the cyclic peptides. For the anabaenopeptins, MS(2) analysis did not provide sufficient sequence information on the cyclic structure, and MS(3) analysis was applied to sequence the constituent amino acids. Diagnostic product ions were obtained by the MS(3) analysis and were quite effective for obtaining the sequence information of the constituent amino acids. MS(2) analysis was, however, sufficient to obtain the sequence information of the aeruginopeptins. In both cases, the resulting product ions obtained from the cyclic structures were formed by the two-bond fission mechanism of the precursor ion, in which an initial fission of the cyclic structure to a linear one and subsequent fission(s) at the peptide bonds are included. The fragmentations were similar for the structurally related compounds, indicating that the cleavages occurred at definite peptide bonds. In addition, the resulting product ions are generated as b(n) series ions and the mass difference facilitates the amino acid sequencing. Thus, ion trap LC/MS(n) provides sequence information, and the resulting product ions are reproducible among the structurally related compounds and reliable for the sequencing of the constituent amino acids of the cyclic structure.  相似文献   

6.
Three unknown impurities in an amodiaquine bulk drug sample were detected by reversed-phase high-performance liquid chromatography with ultraviolet detection (HPLC/UV). A liquid chromatography/tandem mass spectrometry (LC/MS(n)) method is described for the investigation of these impurities. Mass spectral data were acquired on an LCQ ion trap mass analyzer equipped with an electrospray ionization (ESI) source operated in positive ion mode. The fragmentation behavior of amodiaquine and its impurities has been studied. Based on the mass spectral data and the specifics of the synthetic route, the possible structures of these impurities were elucidated as 4-[(5-chloroquinolin-4-yl)amino]-2-(diethylaminomethyl)phenol (impurity I), 4-[(7-chloroquinolin-4-yl)-amino]phenol (impurity II) and 4-[(7-chloroquinolin-4-yl)amino]-2-(diethylaminomethyl)-N(1)-oxy]phenol (impurity III). The structures were confirmed by their independent synthesis and NMR spectral assignment.  相似文献   

7.
Anatoxin-a (AN) and homoanatoxin-a (HMAN) are potent neurotoxins produced by a number of cyanobacterial species. A new, sensitive liquid chromatography/multiple tandem mass spectrometry (LC/MS(n)) method has been developed for the determination of these neurotoxins. The LC system was coupled, via an electrospray ionisation (ESI) source, to an ion-trap mass spectrometer in positive ion mode. The [M+H](+) ions at m/z 166 (anatoxin-a) and m/z 180 (homoanatoxin-a) were used as the precursor ions for multiple MS experiments. MS(2)bond;MS(4) spectra displayed major fragment ions at m/z 149 (AN), 163 (HMAN), assigned to [Mbond;NH(3)+H](+); m/z 131 (AN), 145 (HMAN), assigned to [Mbond;NH(3)bond;H(2)O+H](+), and m/z 91 [C(7)H(7)](+). Although the chromatographic separation of these neurotoxins is problematic, reversed-phase LC, using a C(18) Luna column, proved successful. Calibration data for anatoxin-a using spiked water samples (10 mL) in LC/MS(n) modes were: LC/MS (25-1000 microg/L), r(2) = 0.998; LC/MS(2) (5-1000(microg/L), r(2) = 0.9993; LC/MS(3) (2.5-1000 microg/L), r(2) = 0.9997. Reproducibility data (% RSD, N = 3) for each LC/MS(n) mode ranged between 2.0 at 500 microg/L and 7.0 at 10 microg/L. The detection limit (S/N = 3) for AN was better than 0.03 ng (on-column) for LC/MS(3) which corresponded to 0.6 microg/L.  相似文献   

8.
We have previously described the site-specific glycosylation analysis of rat brain Thy-1 by LC/multistage tandem mass spectrometry (MS(n)) using proteinase-digested Thy-1. In the present study, detailed structures of oligosaccharides released from Thy-1 were elucidated by mass spectrometric oligosaccharide profiling using LC/MS with a graphitized carbon column (GCC-LC/MS). First, using model oligosaccharides, we improved the oligosaccharide profiling by ion trap mass spectrometry (IT-MS) coupled with Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS). Sequential scanning of a full MS(1) scan with FT-ICR-MS followed by data-dependent MS(n) with IT-MS in positive ion mode, and a subsequent full MS(1) scan with FT-ICR-MS followed by data-dependent MS(n) with IT-MS in negative ion mode enabled the monosaccharide composition analysis as well as profiling and sequencing of both neutral and acidic oligosaccharides in a single analysis. The improved oligosaccharide profiling was applied to elucidation of N-linked oligosaccharides from Thy-1 isolated by sodium dodecyl sulfate-polyacrylamide gel electrophoresis. It was demonstrated that Thy-1 possesses a significant variety of N-linked oligosaccharides, including Lewis a/x, Lewis b/y, and disialylated structure as a partial structure. Our method could be applicable to analysis of a small abundance of glycoproteins, and could become a powerful tool for glycoproteomics.  相似文献   

9.
Liquid chromatography (LC) methods compatible with mass spectrometry (MS) that are suitable for impurity profiling of vancomycin mixtures have not been described in the literature. The mobile phases of the existing methods contain non-volatile additives and/or solvents that give problems in combination with MS. In this paper, a reversed-phase LC/tandem mass spectrometry method is described for the investigation of vancomycin and related substances. The LC method uses a Zorbax Extend C18 column (250 x 4.6 mm i.d.), 5 microm, and a mobile phase consisting of methanol, water and ammonium acetate solution (pH 9.0). This method allows us to separate vancomycin and its impurities. Mass spectral data are acquired on an LCQ ion trap mass spectrometer equipped with an electrospray interface operated in the positive and negative ion modes. The LCQ is ideally suited for identification of impurities and related substances because it provides on-line LC/MSn capability, which allows efficient identification without time-consuming isolation and purification procedures. Using this method, the fragmentation of vancomycin and known derivatives was studied and the structures of six substances occurring in commercial samples were elucidated.  相似文献   

10.
With a recently developed liquid chromatographic (LC) method, using a phosphate buffer, several unknown impurities present in dirithromycin samples were separated. In this paper, a reversed-phase liquid chromatography-tandem mass spectrometry method is described for the investigation of dirithromycin and related substances. The method employed uses a Zorbax Extend C18 column (250 mm x 4.6 mm I.D.), 5 microm, and a mobile phase consisting of acetonitrile, 2-propanol, water and ammonium acetate solution pH 8.5. Mass spectral data are acquired on an LCQ ion trap mass spectrometer equipped with an electrospray ion (ESI) source operated in the positive ion mode. The LCQ is ideally suited for the identification of related substances because it provides on-line LC/MS(n) capability, which allows efficient identification without time-consuming isolation and purification procedures. Using this method, the fragmentation behavior of dirithromycin and its related substances was studied and the unknown impurities occurring in commercial samples were investigated. In total the structures of nine impurities were elucidated, among which three were different analogues with a modification in the side chain on the oxazine ring. Two impurities showed a different alkyl group in position C13. In two impurities the desosamine sugar was involved with changes in the degrees of methylation of the amino group. One unknown impurity was identified as dirithromycin F and another unknown was characterized as dirithromycin N-oxide.  相似文献   

11.
Extending the dynamic range of microcapillary liquid chromatography/tandem mass spectrometry (LC/MS/MS) peptide sequencing methods is essential for extracting new discoveries from proteomic studies. The complexity of global protein digests and in vivo processed peptide repertoires (as isolated from immunologically important HLA complexes) have led to the development of novel separation methods to increase the number of peptides identified by a single analysis. Separation of complex mixtures by multidimensional high-performance liquid chromatography (HPLC) decreases the number of isolated peptides contained in each fraction and increases the likelihood of detecting low abundant peptides in a background of dominant signals. In this study, we have evaluated the use of two dimensions of reversed-phase chromatography for resolving and sequencing naturally processed HLA-A2 presented peptide repertoires. The first dimension of separation was reversed-phase chromatography using the strong ion pairing reagent trifluoroacetic acid (TFA) to ensure the highest efficiency of peptide fractionation. The second dimension of reversed-phase chromatography was online with an electrospray ionization (ESI) ion trap mass spectrometer. Mobile phases used for the second dimension of chromatography were modified with volatile reagents including a contemporary acetate-modified acidic solvent, which was compared with mobile phases prepared with ammonium hydroxide at an alkaline pH. As expected, we demonstrate improved separation of the HLA-A2 presented fractions using the alkaline pH conditions. However, less obvious was the improved peptide signal-to-noise detected for peptide signals by positive ion ESI ion trap mass spectrometric detection, which was attributed to a reduced chemical background when using the alkaline pH mobile phases that allowed the ion trap to fill with the peptide ions until the automatic gain control detected a full trap. The term 'wrong-way-round ionization' has been used to describe intense [M+H](+) ions generated during ESI under strongly basic solutions. Ultimately, a larger number of the HLA-A2 peptide repertoire was sequenced by coupling TFA-modified reversed-phase fractionation with alkaline-modified microcapillary LC/MS/MS analysis of each fraction. In the present report, we compare the two second-dimension approaches and demonstrate the quality of data that was acquired using alkaline pH reversed-phase conditions.  相似文献   

12.
The occurrence of human and veterinary pharmaceutical compounds in surface waters (e.g. streams, lakes and reservoirs) is an important emerging environmental issue. There is a need for robust, sensitive and reliable analytical methods for measuring these compounds in a variety of natural water and wastewater matrices. This paper describes a method for the determination of seven tetracycline (TC) and six sulfonamide (SA) compounds in pristine and wastewater-influenced surface water using solid-phase extraction, and LCQ Duo ion trap liquid chromatography/tandem mass spectrometry (LC/MS/MS) with positive electrospray ionization (ESI(+)) and selected reaction monitoring (SRM). The seven TCs and six SAs analyzed using this method include oxytetracycline (OTC), chlortetracycline (CTC), tetracycline (TC), democlocycline (DMC), doxycycline (DXC), meclocycline (MCC), minocycline (MNC), sulfathiazole (STZ), sulfamerazine (SMR), sulfamethazine (SMT), sulfachloropyridazine (SCP), sulfamethoxazole (SMX), and sulfadimethoxane (SDM). This study discusses the effects of flow rate, LC column diameter and LC column temperature on UV and/or mass peak quality of the different analytes. Several product ions for MS/MS detection have been identified and compared for ion trap and triple quadrupole LC/MS/MS instruments. Statistical analysis for determination of the method detection limit (MDL), accuracy and precision of the method is described. Matrix effects are evaluated in deionized, pristine and wastewater-influenced river water. The method is applied to evaluate the occurrence of these compounds in a small watershed in northern Colorado.  相似文献   

13.
The characteristics shown in the electrospray ionization/ion trap mass spectra of ring-opened LI-F antibiotics (cyclic depsihexapeptides with a 15-guanidino-3-hydroxypentadecanoic group as a side-chain) were examined. Collision-induced dissociation (CID) MS of protonated molecules of the depsipeptides produced many fragment ions. Most of these fragment ions contained information for determining the amino acid sequences of antifungal antibiotics. The fragment ions were classified into six groups (b(n'), B(n'), B'(n'), beta(n'), y(n) and Y(n)). According to MS(3) spectra, the B(n'), B'(n) and beta(n) ions can be considered to be derived with a cleavage at each CO--NH in the peptide bonds of [MH--NH(3)](+),[MH--NH(3)--OH](+) and [MH--NH(3)--2H(2)O](+), respectively, in ion trap MS. Losses of NH(3) and H(2)O from the amino acid residues of the depsipeptides in ion trap MS are likely to be smaller than those from the side-chain. The measurements with electrospray ionization (ESI)/ion trap MS of depsipeptides with a side chain containing polar groups may provide useful information for structural determination.  相似文献   

14.
Two isomeric pairs of 2-aminopyridine (PA)-derivatized fucosylated and non-fucosylated oligosaccharides (complex-type N-glycans of IgG) were analyzed using liquid chromatography/ion trap mass spectrometry (LC/ITMS) with a sonic spray ionization source and by varying the collision-induced dissociation voltage. Reproducibility of MS(n) (n = 2) spectra obtained by LC/ITMS was tested considering both fragment ions (m/z) and intensities. A comparison of their MS(n) spectra and evaluation of similarities (or matching), based on correlation coefficients between MS(n) spectra, was investigated as a possibility for structural assignment of the isomers. It is shown that such MS(n) spectral matching is useful and applicable to the structural assignment of relatively large fucosylated and sialylated PA-oligosaccharides released from IgG based on Bn- and Yn-type fragmentations of the corresponding [M+H+Na](2+) ions.  相似文献   

15.
In the pharmaceutical industry, a higher attrition rate during the drug discovery process means a lower drug failure rate in the later stages. This translates into shorter drug development time and reduced cost for bringing a drug to market. Over the past few years, analytical strategies based on liquid chromatography/mass spectrometry (LC/MS) have gone through revolutionary changes and presently accommodate most of the needs of the pharmaceutical industry. Among these LC/MS techniques, collision induced dissociation (CID) or tandem mass spectrometry (MS/MS and MS(n)) techniques have been widely used to identify unknown compounds and characterize metabolites. MS/MS methods are generally ineffective for distinguishing isomeric compounds such as metabolites involving oxygenation of carbon or nitrogen atoms. Most recently, atmospheric pressure ionization (API) source decomposition methods have been shown to aid in the mass spectral distinction of isomeric oxygenated (N-oxide vs hydroxyl) products/metabolites. In previous studies, experiments were conducted using mass spectrometers equipped with a heated capillary interface between the mass analyzer and the ionization source. In the present study, we investigated the impact of the length of a heated capillary or heated ion transfer tube (a newer version of the heated capillary designed for accommodating orthogonal API source design) in inducing for-API source deoxygenation that allows the distinction of N-oxide from hydroxyl compounds. 8-Hydroxyquinoline (HO-Q), quinoline-N-oxide (Q-NO) and 8-hydroxyquinoline-N-oxide (HO-Q-NO) were used as model compounds on three different mass spectrometers (LCQ Deca, LCQ Advantage and TSQ Quantum). Irrespective of heated capillary or ion transfer tube length, N-oxides from this class of compounds underwent predominantly deoxygenation decomposition under atmospheric pressure chemical ionization conditions and the abundance of the diagnostic [M + H - O](+) ions increased with increasing vaporizer temperature. Furthermore, the results suggest that in API source decompostion methods described in this paper can be conducted using mass spectrometers with non-heated capillary or ion transfer tube API interfaces. Because N-oxides can undergo in-source decomposition and interfere with quantitation experiments, particular attention should be paid when developing API based bioanalytical methods.  相似文献   

16.
1-Hydroxypyrene glucuronide is identified as the single major aqueous metabolite of the tetracyclic aromatic hydrocarbon pyrene, in tissue from a deposit-feeding marine polychaete, Nereis diversicolor. Identification was performed using an ion trap mass spectrometer fitted with an atmospheric pressure chemical ionization (APCI) probe and connected to a high-performance liquid chromatography/diode array detector (HPLC/DAD) system. Besides 1-hydroxypyrene, the 339-nm UV trace of tissue samples from pyrene-exposed worms showed only one dominant peak that could be related to pyrene metabolism. Negative APCI-MS of this supposed 1- hydroxypyrene conjugate gave a characteristic signal at m/z 429 corresponding to the molecular ion of 1-hydroxypyrene glucuronide plus eluent adducts ([M - H + 2H(2)O](-)). Fragmentation pathways were studied by isolating the abundant ion at m/z 429 in the ion trap and performing multiple mass spectrometric experiments (MS(n)). The fragmentations observed were consistent with the proposed identification. Two low intensity LC peaks that could be related to pyrene metabolism by their DAD absorption spectra were also present in the 339-nm UV chromatogram of tissue samples. However, these peaks could not be identified by their mass spectra in negative ion mode due to ion suppression by very abundant co-eluting impurities. The present method shows that LC/MS(n) is a fast and useful analytical tool for identification of aqueous polycyclic aromatic hydrocarbon biotransformation products in samples from relatively small marine invertebrates with limited sample preparation.  相似文献   

17.
a(n) ions are frequently formed in collision-induced dissociation (CID) of protonated peptides in tandem mass spectrometry (MS/MS) based sequencing experiments. These ions have generally been assumed to exist as immonium derivatives (-HN(+)═CHR). Using a quadrupole ion trap mass spectrometer, MS/MS experiments have been performed and the structure of a(n) ions formed from oligoglycines was probed by infrared spectroscopy. The structure and isomerization reactions of the same ions were studied using density functional theory. Overall, theory and infrared spectroscopy provide compelling evidence that a(n) ions undergo cyclization and/or rearrangement reactions, and the resulting structure(s) observed under our experimental conditions depends on the size (n). The a(2) ion (GG sequence) undergoes cyclization to form a 5-membered ring isomer. The a(3) ion (GGG sequence) undergoes cyclization initiated by nucleophilic attack of the carbonyl oxygen of the N-terminal glycine residue on the carbon center of the C-terminal immonium group forming a 7-membered ring isomer. The barrier to this reaction is comparatively low at 10.5 kcal mol(-1), and the resulting cyclic isomer (-5.4 kcal mol(-1)) is more energetically favorable than the linear form. The a(4) ion with the GGGG sequence undergoes head-to-tail cyclization via nucleophilic attack of the N-terminal amino group on the carbon center of the C-terminal immonium ion, forming an 11-membered macroring which contains a secondary amine and three trans amide bonds. Then an intermolecular proton transfer isomerizes the initially formed secondary amine moiety (-CH(2)-NH(2)(+)-CH(2)-NH-CO-) to form a new -CH(2)-NH-CH(2)-NH(2)(+)-CO- form. This structure is readily cleaved at the -CH(2)-NH(2)(+)- bond, leading to opening of the macrocycle and formation of a rearranged linear isomer with the H(2)C═NH(+)-CH(2)- moiety at the N terminus and the -CO-NH(2) amide bond at the C terminus. This rearranged linear structure is much more energetically favorable (-14.0 kcal mol(-1)) than the initially formed imine-protonated linear a(4) ion structure. Furthermore, the barriers to these cyclization and ring-opening reactions are low (8-11 kcal mol(-1)), allowing facile formation of the rearranged linear species in the mass spectrometer. This finding is not limited to 'simple' glycine-containing systems, as evidenced by the IRMPD spectrum of the a(4) ion generated from protonated AAAAA, which shows a stronger tendency toward formation of the energetically favorable (-12.3 kcal mol(-1)) rearranged linear structure with the MeHC═NH(+)-CHMe- moiety at the N terminus and the -CO-NH(2) amide bond at the C terminus. Our results indicate that one needs to consider a complex variety of cyclization and rearrangement reactions in order to decipher the structure and fragmentation pathways of peptide a(n) ions. The implications this potentially has for peptide sequencing are also discussed.  相似文献   

18.
2-Chloroethylethyl sulfide (CEES) is used as a simulant for mustard (HD) in a study to develop secondary ion mass spectrometry (SIMS) for rapid, semi-quantitative detection of mustard on soil. Selectivity and sensitivity are markedly improved employing multiple-stage mass spectrometry (MS(n)) using an ion trap SIMS. C(2)H(5)SC(2)H(4)(+) from CEES eliminates C(2)H(4) and H(2)S, which are highly diagnostic. CEES was detectable at 0.0012 monolayer on soil. This corresponds to approximately 15 ppm (mass/mass) for a soil having a surface area of 12 m(2) g(-1). A single analysis could be conducted using only 2 mg of soil in under 5 min.  相似文献   

19.
A sensitive, integrated top-down liquid chromatography/mass spectrometry (LC/MS) approach, suitable for the near complete characterization of specific proteins in complex protein mixtures, such as inclusion bodies of an E. coli lysate, has been successfully developed using a hybrid linear ion trap/Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. In particular, human growth hormone (hGH) (200 fmol) was analyzed with high sequence coverage (>95%), including the sites of disulfide linkages. The high mass accuracy and resolution of the FTICR mass spectrometer was used to reveal high charge state ions of hGH (22 kDa). The highly charged intact protein ions (such as the 17+ species) were captured and fragmented in the linear ion trap cell. The fragment ions from MS/MS spectra were then successfully analyzed in the FTICR cell in an on-line LC/MS run. Peptide fragments from the N-terminal and C-terminal regions, as well as large interior fragments, were captured and identified. The results allowed the unambiguous assignment of disulfide bonds Cys53-Cys165 and Cys182-Cys189, indicative of proper folding of hGH. The disulfide bond assignments were also confirmed by analysis of the tryptic digest of a sample of hGH purified from inclusion bodies. On-line LC/MS with the linear ion trap/FTICR yields high mass accuracy in both the MS and MS/MS modes (within 2 ppm with external calibration). The approach should prove useful in biotechnology applications to characterize correctly folded proteins, both in the early protein expression and the later processed stages, using only a single automated on-line LC/MS top-down method.  相似文献   

20.
For the determination of glutathione (GSH) and its oxidized form (GSSG) in spruce needles their electrospray mass and MS/MS spectra were recorded with an ion trap mass spectrometer (ITMS, LCQ, Finnigan) and a triple stage quadrupole mass spectrometer (TSQ, Quattro II, Micromass). A study of the stability of GSH in aqueous solutions shows the presence of dimeric and trimeric forms of GSH, as well as GSSG, GSH-sulfonate and GSH-sulfinic acid. The same components were also found in extracts of spruce needles. We developed an assay which is suitable for monitoring low concentrations of GSH and similar compounds in plant tissues, employing the sensitivity and specificity of LC/MS/MS. Preliminary results on the mass spectrometric determination of GSH in spruce needles are given.  相似文献   