1.
The effects of extremely low frequency magnetic field (ELF-MF)(1 mT, 50 Hz) on the heat shock protein (HSP) synthesis in Escherichia coli were investigated. Two magnetic field signals were studied: sinusoidal (SMF) and pulsed square wave (PMF). It was found that bacteria exposed to SMF showed a significantly higher level of DnaK and GroEL proteins as compared to sham-exposed bacteria as revealed by Western blot, whereas a lower level was observed after PMF exposure. Similar results were obtained when bacterial cells were exposed to heat shock (HS) after ELF-MF exposure: again SMF and PMF resulted in an increase and in a reduction of HSP amount in comparison with sham control, respectively. In conclusion, the MF influences the synthesis of HSPs in E. coli in a way that critically depends on the signal characteristics.  相似文献   

2.
The previously introduced technique of potential-modulated fluorescence (PMF) spectroscopy was used to study the potential-induced fluorescence change of some different dyes at the polarized 1,2-dichloroethane (DCE)/water (W) interface. A zwitterionic dye (POLARIC 488PPS) showed a PMF response similar to that for the previously studied dye (di-4-ANEPPS) with the same ionic state, and the PMF response was likewise explained by the potential-dependent reorientation of the dye at the DCE/W interface. Though a monocationic dye (POLARIC 488PM) showed no distinct PMF signal, a dicationic dye (di-2-ANEPEQ) showed two relatively weak but detectable PMF signals at lower and higher potential. It has thus been found that the ionic state of a potential-sensitive dye strongly influences the potential-induced reorientation of the dye at the interface and consequently its PMF response. These results support the reorientation/solvatochromic mechanism proposed for "slow" dyes but do not necessarily exclude the electrochromic mechanism proposed for "fast" dyes. PMF spectroscopy would provide useful information on the design of slow dyes for the measurement of the resting potential of cell membranes.  相似文献   

3.
We have shown that weak oscillating electromagnetic fields in the pericellular environment modulate key steps in coupling of signals from humoral stimuli at cell surface receptors to intracellular systems. This paper summarizes evidence that enzymatic activity within the cell provides sensitive molecular markers about both the sequence and the energetics of transmembrane coupling mechanisms. As research tools, these imposed fields appear to offer unique opportunities for understanding highly non-linear, non-equilibrium aspects of these coupling mechanisms, including the basis for amplification of weak pericellular stimuli to achieve an energetic threshold in signaling to intracellular enzyme systems.A three-stage model of membrane transductive coupling is proposed: a first stage in which weak pericellular electrochemical oscillations and binding of humoral stimulating molecules at receptor sites initiates a highly cooperative modification of calcium binding, a second stage involving transmission of signals initiated at receptor sites to the cell interior; and a third stage dealing with intracellular response to the transmembrane signal.Low frequency pulsed magnetic fields modulate stimulation of adenylate cyclase by parathyroid hormone (PTH) in bone cells. From collateral studies of field effects on PTH-binding to its receptor and from studies of fluoride activation of adenylate cyclase, there is evidence that an important field action is on membrane coupling proteins between receptors for PTH and adenylate cyclase.In addition to an action on adenylate cyclase, weak pericellular fields modulate activity of messenger enzymes, the protein kinases, and of an enzyme essential for cell growth, omithine decarboxylase. In human lymphocytes, cAMP-independent protein kinases are transiently inhibited by exposure to weak (athermal) microwave fields sinusoidally modulated at 16 Hz. In liver and ovary cells exposed to the same fields, and in bone cells exposed to low frequency pulsed magnetic fields, omithine decarboxylase activity is increased.Experimental data and models interrelating the pericellular electrochemical environment, cancer-promoting phorbol esters and activities of protein kinases and ornithine decarboxylase are discussed.  相似文献   

4.
We previously studied the response of mammalian cultured cells to weak, 60 Hz-electromagnetic (EM) fields. Two time constants, similar to those observed in chemotaxis, were found to govern the cellular response to the field. We concluded that a system of temporal sensing, similar to that employed in chemotaxis by motile bacteria, was operative. We termed the shorter time (approximately 0.1 s) the "sensing" time, and the longer time (approximately 10 s) the "memory" time. To investigate the possibility that temporal sensing was a general property of EM field-cell interaction, the temporal properties of another EM field-induced effect was studied. The EM field-induced protection against the effects of extreme hypoxia was examined in chick embryos. Embryos were exposed to 60 Hz-magnetic fields, the amplitudes of which were regularly altered throughout the 20-min exposure. Alteration was accomplished either by turning the field off and on at regular intervals (1-50 s), or by introducing brief (10 or 100 ms), zero amplitude gaps, once each second, throughout exposure. When the field was turned on and off at 0.1 s intervals, the protective effect conferred by a constant field was lost. At progressively longer on/off intervals, protection was progressively restored, maximizing at intervals of 10-30 s. Gapping the magnetic field for 10 ms, each second of exposure conferred the same protection as that observed for an uninterrupted field, but gapping the field at 100 ms each second produced a significant reduction in protection. These data exhibit remarkable consistency with those obtained in similar temporal studies of the magnetic field-induced enhancement of ornithine decarboxylase activity in L929 fibroblasts. It appears that temporal sensing is a general feature of the EM field-cell interaction.  相似文献   

5.
Modified two-dimensional (2D) triple-resonance H(C)P and H(P)C experiments based on INEPT/HMQC and double-INEPT schemes are applied to the study of organophosphorus compounds at natural abundances. The implementation of effective (1)H--(13)C gradient selection, additional purging pulsed field gradients, spinlock pulses, and improved phase cycling is demonstrated to allow weak correlation signals based on long-range couplings to be readily observed. Through the combination of two heteronuclear long-range coupling constants, (n)J(CH) and (n)J(PC) in H(C)P experiments or (n)J(PH) and (n)J(PC) in H(P)C experiments, protons can be correlated to a second heteronucleus through 4-7 chemical bonds. These experiments thus overcome the inherit limitations of classical (1)H-X HMBC experiments, which require a nonzero value of the heteronuclear coupling constant (n)J(XH). Ultra-broadband inversion composite pulses are successfully employed in the H(P)C INEPT/HMQC and H(P)C double-INEPT pulse sequences to increase the utility of the experiments and the quality of obtained spectra. This work extends and completes a set of 2D phase-sensitive triple-resonance experiments applicable at natural abundances, and also offers insight into the methodology of triple-resonance experiments and the application of pulsed field gradients. A one-dimensional triple-resonance experiment employing carbon detection is suggested for accurate determination of small (n)J(PC).  相似文献   

6.
The obvious enhancement effect of magnetic nanoparticles (MNPs) introduced in Cr/Co/Cr/Au substrate on the pulsed magnetic field-modulated surface plasmon coupled emission (SPCE) was investigated, and the observed enhancement factor was 4 comparing with the magnetic field modulated SPCE without MNPs. This is the new observation for the magnetic field modulated SPCE, and this method was designed as a biosensor, which to our knowledge, is the first application of magnetic field-modulated SPCE in biosensing and detection field. This strategy is a universal approach to increase the fluorescence signal and helps to build the new SPCE based stimulus-response system.  相似文献   

7.
The spin mixing process of the radical pair in the sodium dodecyl sulfate (SDS) micelle is studied by using a novel technique nanosecond pulsed magnetic field effect on transient absorption. We have developed the equipment for a nanosecond pulsed magnetic field and observed its effect on the radical pair reaction. A decrease of the free radical yield by a reversely directed pulsed magnetic field that cancels static field is observed, and the dependence on its magnitude, which is called pulsed MARY (magnetic field effect on reaction yield) spectra, is studied. The observed spectra reflect the spin mixing in 50-200 ns and show clear time evolution. Theoretical simulation of pulsed MARY spectra based on a single site modified Liouville equation indicates that the fast spin dephasing processes induced by the modulation of electron-electron spin interaction by molecular reencounter affect to the coherent spin mixing by a hyperfine interaction in a low magnetic field.  相似文献   

8.
This article demonstrates the enhancement of magnetic nanoparticles on magnetic field modulation of surface plasmon coupled emission (SPCE), and this method is designed as a biosensor to prove the feasibility of magnetic field modulated SPCE to be employed in the field of biosensing and biodetection.  相似文献   

9.
To further investigate the (19)F and (1)H nuclear hyperfine structure and Zeeman effect in the simplest singlet carbene, HCF, we recorded polarization quantum beat spectra (QBS) of the pure bending levels 2(0) (n) with n = 0-7 and combination bands 1(0) (1)2(0) (n) with n = 1-6 and 2(0) (n)3(0) (1) with n = 0-3 in the HCF A(1)A(")<--X(1)A(') system. The spectra were measured under jet-cooled conditions using a pulsed discharge source, both at zero field and under application of a weak magnetic field (<30 G). Analysis yielded the nuclear spin-rotation constants C(aa) and weak field Lande g(aa) factors. Consistent with a two-state model, the majority of observed vibrational levels exhibit a linear correlation of C(aa) and g(aa), and our analysis yielded effective (a) hyperfine constants for the (19)F and (1)H nuclei (in MHz) of 728(23) and 55(2), respectively. The latter was determined here owing to the high resolving power of QBS. The vibrational state selectivity of the (19)F hyperfine constants is discussed, and we suggest that the underlying Renner-Teller interaction may play an important role.  相似文献   

10.
The effect of weak pulse electric fields on the destructive activity and surface properties of Pseudomonas bacteria is studied. It is revealed that the physiological response of bacteria on their treatment by external pulse fields depends on field parameters and is accompanied by the changes in the values of electrokinetic potential and hydrophobicity. The treatment of bacteria by the electric field with pulse duration of 1–10 ms and frequency of 100–500 Hz tends to increase by 20–30% the destruction of NaAg(CN)2. It is suggested that changes in surface properties and the enhancement of biochemical activity of bacteria are based on the metabolic reaction of the cell related to the stimulation or suppression of the bacteria respiration upon the imposition of external field.  相似文献   

11.
A polystyrenesulfonic acid resin in the hydrogen form is a useful stationary phase for chromatographic separation of adenine, caffeine, theobromine, theophylline, tannic acid, xanthine and tea components with aqueous ethanol as eluent. The results indicated that caffeine, theophylline, theobromine, adenine, xanthine and tannic acid could be separated on a column of Dowex-50W-X8(H)+ by elution with 25% ethanol as eluent.  相似文献   

12.
We report control of the haze value in a liquid crystal (LC) cell driven by a fringe electric field. When a fringe field is applied to a vertically aligned (VA) cell, a large spatial phase difference with a short grating period is induced in the LC layer. The average grating period of a VA cell driven by a fringe field is a quarter of the pitch of the interdigitated electrodes, which is half of the grating period of a VA cell driven by an in-plane field. Moreover, a sharper spatial phase profile is built around the edges of the interdigitated electrodes, which led to a high haze of 84.3% in the translucent state. The device was haze-free in the transparent state owing to the use of an LC layer without a polymer structure. To increase the haze value of the LC device while retaining a short response time, we developed an LC cell with crossed interdigitated electrodes where a large spatial phase difference is induced with little dependence on the azimuth angle. By applying a fringe electric field to a 20 μm thick LC cell using crossed interdigitated electrodes, we demonstrated a very high haze of 95.4% and a response time of less than 5 ms.  相似文献   

13.
We have recently reported that weak electromagnetic (EM) field exposure of chick embryos induces a response that can be used to protect against subsequent hypoxic insult. This work is continued here with an exposure response study using 20-min exposure to 60 Hz magnetic fields over a range of 2-10 microT. Once again, the biomarker used was induction of hypoxia protection. A sigmoidal response curve was found, with exposures to magnetic field strengths > or = 4 microT inducing maximum hypoxia protection (68% survival). We also attempted to determine whether the magnetic or induced electric component of the EM field was responsible for the observed protection. This was accomplished by making measurements with two different orientations of the magnetic fields (perpendicular and parallel to the major axis of the egg). Owing to the configuration of the embryo in the egg, the induced electric field at the embryo was lower when the magnetic field was parallel to the major axis even though the magnetic field strength was the same for each orientation. Exposure of the embryos to the parallel orientation resulted in a reduced protective response. An exposure-response curve generated for this orientation of the field also showed a more "drawn-out" appearance, consistent with the observed distribution of embryo positions within the egg. Our results suggest that the induced electric, not the applied magnetic field, plays a primary role in the protective effect observed in this chick embryo model.  相似文献   

14.
Cryptochromes are suggested to be involved in the bird magnetoreception based on the radical pair mechanism (RPM), a well established theory of weak magnetic field effects on chemical reactions. Two members of cryptochrome/photolyase family were found to respond to magnetic field, however, no direct responses of bird cryptochrome to magnetic field as weak as the Earth's magnetic field have been obtained so far. In this study, we used transient fluorescence spectroscopy to characterize the weak magnetic field effects of bird cryptochromes. To do this, we cloned the cryptochrome 1 gene (clCRY1) from the retina of homing pigeons (Columba livia), expressed it in insect Sf9 cells and analyzed the transient fluorescence of purified clCRY1 by application of 45–300 μT magnetic fields. The flavin adenine dinucleotide (FADox) and glucose oxidase (GOD) in PBS buffer were set as controls which could be excited by light to generate radicals, but would not be sensitive to magnetic field. We observed that the transient fluorescence spectra of clCRY1 were sensitive to the applied magnetic field at room temperature. Our result provides a new proof of the cryptochrome‐based model of avian magnetoreception in vitro.  相似文献   

15.
《中国化学会会志》2018,65(2):163-188
We present a few novel pulsed electron paramagnetic resonance techniques developed in our laboratory for the studies of structure and dynamics of the photo‐excited triplet state of organic molecules. We discuss many aspects of these new techniques and the significances of these measurements: (1) enhancing NMR signal intensity by dynamic nuclear polarization ‐ integrated solid effect, (2) performing magnetic resonance in zero‐field and low‐field by pulsed microwave, (3) mapping molecular motion of organic crystals by pulsed zero‐field and low‐field experiments, (4) probing spin dynamics at level anti‐crossing by fast field switching, (5) measuring hyperfine interaction by electron spin echo envelop modulation and spin‐echo electron nuclear double resonance and (6) detecting spin dynamics, nuclear quantum oscillation, entanglements and new avenues for quantum computer. We have employed the highly electron spin polarized pentacene triplet state as the model system in all of our pulsed EPR experiments. We performed most of our experiments at room temperature. The goals of our studies are aiming to improve spin detectability, to probe molecular dynamics, to determine electronic structures, to measure molecular interaction and motion, and to examine quantum coherence and oscillation which may yield new avenues in the applications of pulsed EPR techniques to quantum computer.  相似文献   

16.
The two-pulse COSY revamped by asymmetric Z-gradient echo detection (CRAZED) NMR experiment has the basic form 90 degrees -Gdelta-t(rec)-beta-nGdelta-t(rec)-FID, with a phase-encoding gradient pulse G of length delta applied during the evolution time tau for transverse magnetization, readout pulse beta, rephasing gradient nGdelta, and recovery time t(rec) prior to acquisition of the free-induction decay. Based on the classical treatment of the spatially modulated dipolar demagnetizing field and without invoking intermolecular multiple-quantum coherence, a new formulation of the first-order approximation for the theoretical solution of the nonlinear Bloch equations has been developed. The nth-order CRAZED signal can be expressed as a simple product of a scaling function C(n)(beta,tau) and a signal amplitude function A(n)(t), where the domain t begins immediately after the beta pulse. Using a single-quantum coherence model, a generalized rf phase shift function has also been developed, which explains all known phase behavior, including nth-order echo selection by phase cycling. Details of the derivations are provided in two appendices as supplementary material. For n>1, A(n)(t) increases from zero to a maximum value at t=t(max) before decaying and can be expressed as a series of n exponential decays with antisymmetric binomial coefficients. Fourier transform gives an antisymmetric binomial series of Lorentzians, where the composite lineshape exhibits negative wings, zero integral, and a linewidth that decreases with n. Analytical functions are presented for t(max) and A(n)(t(max)) and for estimating the maximal percent error incurred for A(n)(t(max)) when using the first-order model. The preacquisition delay Delta=delta+t(rec) results in the loss of the data points for t=0 to Delta. Conventional Fourier transformation produces time-zero truncation artifacts (reduced negative wing amplitude, nonzero integral, and reduced effective T(2) ( *)), which can be avoided by time-domain fitting after right shifting the data by Delta. A doped water sample (9.93 mM NiSO(4), 10 mm sample tube) was used to study the behavior of the CRAZED signal for n=1-4 with beta=90 degrees at 7 T (300 MHz (1)H frequency) as a function of Delta, with and without radiation damping. Pulse-acquire experiments were used to determine the relaxation times (T(1)=61.8 ms and T(2) ( *)=29.7 ms), and the radiation damping time constant T(rd)=18.5 ms. When experimental CRAZED data sets were right shifted by Delta, excellent least-squares fits to the first-order model function were obtained for all n using a minimal set of free variables. Without radiation damping the fitted T(2) ( *)values (29.7-30.2 ms) agreed with the reference value. With radiation damping the fitted effective T(2) ( *) values were 16.2 ms for a 90 degrees pulse-acquire experiment and 18.8-20.2 ms for the CRAZED experiment with n=1-4 and signal amplitudes spanning a range of 10(5).  相似文献   

17.
A paramagnetic ferrocenium-based ionic liquid that exhibits a magnetic memory effect coupled with a liquid-solid phase transformation has been developed. Based on field alignment of the magnetically anisotropic ferrocenium cation, the magnetic susceptibility in the solid state can be tuned by the weak magnetic fields (<1 T) of permanent magnets.  相似文献   

18.
The work deals with the experimental study of the emulsion whose dispersion medium is a magnetic fluid while the disperse phase is formed by a glycerin-water mixture. It is demonstrated that under effect of a magnetic field chain aggregates form from the disperse phase drops. Such emulsion microstructure change affects its macroscopic properties. The emulsion dielectric permeability and specific electrical conductivity have been measured. It is demonstrated that under the effect of relatively weak external magnetic fields (~1 kA/m) the emulsion electrical parameters may change several fold. The work theoretically analyzes the discovered regularities of the emulsion electrical properties.  相似文献   

19.
When Escherichia coli B was aerobically grown at 43 degrees C in a medium whose concentration was one-fourth that of the Luria-Bertani (LB) medium supplemented with 1.5 g/l of glutamic acid, drastic cell death was observed after the end of the logarithmic growth phase. However, when the same experiment was conducted under inhomogeneous 5.2-6.1 T magnetic field, cell death was extremely suppressed and the ratio of viable cell number under high magnetic field to that under geomagnetic field reached as much as 100,000. When the magnetic field exposure was restricted to 12 h after the logarithmic growth phase, a similar high degree of suppressive effect on the death was observed. The findings that the amount of sigma S protein encoded by the rpoS gene under the high magnetic field was larger than that under the geomagnetic field, and that the magnetic field effect disappeared when the rpoS gene-deficient strain was cultivated under the high magnetic field, suggest the interaction of magnetic field with a stationary phase specific gene.  相似文献   

20.
《Chemical physics letters》1985,119(5):421-425
The electron spin echo method combined with pulsed gradients of an external magnetic field has been proposed for studies on the spatial distribution of paramagnetic centres. The relationship has been found between the distribution function of paramagnetic centres and the dependence of the spin echo signal on the parameters of the applied gradients. The resolution of the method depends on the ratio of the inverse phase relaxation time (T2−1) to the magnetic field-gradient and may be much higher than the resolution of standard ESR tomography. The method has been applied to a model system.  相似文献   