首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Donaldson EM  Mark E 《Talanta》1982,29(8):663-669
The chloroform extraction of 30 elements (Fe, Co, Ni, Zn, Cd, Ge, Sn, V, As, Sb, Bi, Cu, Ag, Au, Mn, Re, Ga, In, Tl, Se, Te, Cr, Mo, U, Pt, Pd, Rh, Ir, Ru and Ce) from 0.1-8M sulphuric acid in the presence of potassium ethyl xanthate has been studied. Pd(II), Bi, As(III), Sb(III), Se(IV) and Te(IV) are completely extracted and Au(III) is largely extracted over the range of acid concentration investigated. Fe(II), Tl(I), Rh(III) and Cr(VI) are only slightly extracted and Se(VI), Te(VI), Ru(III), Cr(III), Mn(II), Zn, Ce(IV), Ir(IV) and Ge(IV) are not extracted at all. Depending on the acid concentration, the remaining elements are all partly extracted. Results are compared with those obtained in an earlier study of the extraction of xanthate complexes from hydrochloric acid media. The processes involved in the formation of some xanthate complexes and potential analytical separations are discussed.  相似文献   

2.
Oximidobenzotetronic acid is recommended for the separation and gravimetric determination of palladium and cobalt An ethanolic solution of the reagent quantitatively precipitates palladium(II) from solutions which are 0.75 N in acid up to pH 5.1, the complex is weighed as Pd(C9H5NO4)2. Cobalt(II) can be determined in the filtrate after the precipitation of palladium. With 0.5 N acid solutions, no interference was found from Pt(IV), Ir(IV), Rh(III), Ru(III), Os(IV), Au(III), Ag(I), Cu(II), Fe(III), Ni(II), Hg(II). Pb(II), Bi(III), Cd(II), As(V), Se(VI), Te(IV), Mo(VI), Sb(III), Al(III), Cr(III), Zn(II), Ti(IV), Zr(IV). acetate, oxalate, citrate, tartrate, phosphate and fluoride.  相似文献   

3.
The ion chromatography of chloro complexes of Au(III), Ir(IV), Ir(III), Os(IV), Pd(II), Pt(IV), Rh(III) and Ru(III) was investigated using anion-exchange and ion-interaction techniques involving silica-based phases. Chloride was either absent or at a very low level and the pH was high enough to enable steel-fabricated liquid chromatography equipment to be used. With anion exchange, Ir(IV), Ir(III), Os(IV) and Pt(IV) gave good stable chromatography and all produced linear calibration plots, except Ir(IV) owing to instability of the sample solution. The detection limits were Ir(III) 5, Os(IV) 10 and Pt(IV) 2 ng ml?1. The ion-interaction technique was not so successful, only Au(III) and Pd(II) giving stable chromatography. The calibration plots were slightly curved, although acceptable, and the detection limits were 10 and 30 ng ml?1 for Au (III) and Pd(II), respectively.  相似文献   

4.
A procedure is described for determining the noble metals in geological samples of varied composition (Si enriched or Cr enriched). This rapid separation procedure allows very low detection limits for all PGE (except Rh) and Ag. It uses the coprecipitation of Pd, Pt, Au, Ag and Ru with Se and Te, and the fixation of Os on an ion-exchange resin. Ir is systematically determined by epithermal NAA using multiparameter coincidence spectrometry.  相似文献   

5.
Summary The extraction of the elements Ti, V, Cr, Mn, Fe, Co, Ni, Zn, Ga, As, Nb, Mo, Ru, Rh, Pd, Ag, Cd, In, Sn, Sb, La, W, Re, Os, Ir, Pt, Au, Hg, Tl, Pb and Bi from hydrochloric acid into methyl isobutyl ketone has been studied as a function of hydrochloric acid concentration. The results are presented in graphical form. The data were obtained by studying the distribution patterns of the elements after equilibration on a Craig countercurrent liquid-liquid extraction apparatus.
Zusammenfassung Die Extraktion der Elemente Ti, V, Cr, Mn, Fe, Co, Ni, Zn, Ga, As, Nb, Mo, Ru, Rh, Pd, Ag, Cd, In, Sn, Sb, La, W, Re, Os, Ir, Pt, Au, Hg, Tl, Pb und Bi mit Methylisobutylketon aus salzsaurer Lösung als Funktion der Säurekonzentration wurde studiert. Die Ergebnisse wurden aus den Spitzen der Verteilungskurven nach Einstellung des Gleichgewichts in einem diskontinuierlichen Gegenstrom-flüssig-flüssig-Extraktionsapparat berechnet.

Résumé On a étudié l'extraction des éléments Ti, V, Cr, Mn, Fe, Co, Ni, Zn, Ga, As, Nb, Mo, Ru, Rh, Pd, Ag, Cd, In, Sn, Sb, La, W, Re, Os, Ir, Pt, Au, Hg, Tl, Pb et Bi en solution chlorhydrique par la méthylisobutylcétone. On présente les résultats sous forme graphique. Les données ont été obtenues en étudiant les diagrammes de distribution des éléments après équilibrage sur un appareil Craig à extraction à contre-courant liquide-liquide.
  相似文献   

6.
Strelow FE  Wienert CH  van der Walt TN 《Talanta》1974,21(11):1183-1191
Indium can be separated from Zn, Pb(II), Ga, Ca, Be, Mg, Ti(IV), Mn(II), Fe(III), Al, U(VI), Na, Ni(II) and Co(II) by selective elution with 0.50M hydrochloric acid in 30% aqueous acetone from a column of AG50W-X8 cation-exchange resin, all the other elements being retained by the column. Lithium is included in the elements retained by the column when 0.35M hydrochloric acid in 45% aqueous acetone is used for eluting indium, but the elution of indium is slightly retarded. Ba, Sr, Zr, Hf, Th, Sc, Y, La and the lanthanides, Rb and Cs should also be retained according to their distribution coefficients. Cd, Bi(III), Au(III), Pt(IV), Pd(II), Rh(III), Mo(VI) and W(VI) can be eluted with 0.20M hydrobromic acid in 50% aqueous acetone before the elution of indium, and Ir(III), Ir(IV), As(III), As(V), Se(IV), Tl(III), Hg(II), Ge(IV), Sb(III) and Sb(V), though not investigated in detail, should accompany these elements. Relevant distribution coefficients and elution curves and results for analyses of synthetic mixtures of indium with other elements are presented.  相似文献   

7.
We established Multitracer, a new versatile radiotracer technique, for simultaneous tracing of a number of elements in various chemical, environmental, and biological systems. Metal foil targets (typically Au, Ag, Ge, Cu and Fe) are irradiated with C, N, or O ions accelerated up to 135 MeV/nucleon by RIKEN Ring Cyclotron. Radiochemical procedures have been developed to remove the target material leaving the nuclides as Multitracer solutions containing various radionuclides of Be, Na, Mg, K, Ca, Sc, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, As, Se, Br, Rb, Sr, Y, Zr, Nb, Mo, Tc, Ru, Rh, Pd, Ag, Cd, In, Sn, Te, I, Ba, Ce, Pm, Eu, Gd, Tb, Tm, Yb, Lu, Hf, W, Re, Os, Ir, Pt, and Hg. Multitracers enable efficient tracing of a number of elements, and comparison of their behavior under strictly identical experimental conditions. Such features will be demonstrated by means of an example of application to a model experiment for the study of removal mechanism of various elements from the ocean.  相似文献   

8.
Luminol-K2S2O8体系中金属离子化学发光行为的研究   总被引:1,自引:0,他引:1  
张新荣  章竹君 《化学学报》1987,45(2):195-197
报导了在自行设计的流动注射式化学发光分析仪上,对Luminal-K2S2O8体系中32种金属离子的化学发光行为的系统研究.确定了对金属离子的最优测定条件以及大多数金属离子的检出极限和线性范围.  相似文献   

9.
Hualing D  Zhide H 《Talanta》1989,36(6):633-637
The ion flotation of 31 metal ions in hydrochloric/nitric acid solution with the cationic surfactant cetylpyridinium chloride was investigated. A 25-ml portion of 0.27-2.87 x 10(-4)M metal ion and 1.8-6.0 x 10(-4)M cetylpyridinium chloride solution in 0.17-3.4M acid mixture ([HCl]:[HNO(3)] = 2.4:1) was subjected to flotation in a cell, 22.5 cm high and 4.0 cm in diameter, for 5 min, with nitrogen bubbles. Ir(IV), Pt(IV), Ge(IV), Sn(IV), Bi(III), Au(III), Tl(III), Pd(II) and Sn(II) were floated from solution in 95-100% yield; Ru(III), Rh(III), Ir(III), Hg(II), Ag(I) and Tl(I) were partly floated, while Cr(VI), Ti(IV), Zr(IV), Ga(III), In(III), Fe(III), Sb(III), Al(III), Mn(II), Fe(II), Co(II), Ni(II), Cu(II), Zn(II), CD(II) and Pb(II) were floated with less than 20% yield. The flotation behaviour of these metal ions in the mixed acid system was compared with that in hydrochloric acid. The flotation is more efficient in the mixed acid system.  相似文献   

10.
Ruthenium(III) has been efficiently extracted from 0.05 M sodium succinate at pH 9.5 by 2-octylaminopyridine in xylene and stripped with aqueous 10% (w/v) thiourea solution and determined spectrophotometrically. Various parameters viz., pH, weak acid concentration, reagent concentration, stripping agents, contact time, loading capacity, aq.: org. volume ratio, solvent has been thoroughly investigated for quantitative extraction of ruthenium(III). The utility of method was analyzed by separating the ruthenium(III) from binary mixture along with the base metals like Cu(II), Ag(I), Fe(II), Co(II), Bi(III), Zn(II), Ni(II), Se(IV), Te(IV), Al(III) and Hg(II) as well as platinum group metals (PGMs). Ruthenium(III) was also separated from ternary mixtures like Os(VIII), Pd(II); Pd(II), Pt(IV); Pd(II), Au(III); Pd(II), Cu(II); Fe(II), Cu(II); Ni(II), Cu(II); Co(II), Ni(II); Se(IV), Te(IV); Rh(III), Pd(II); Fe(III), Os(VIII). The stoichiometry 1: 2: 1 (metal: succinate: extractant) of the proposed complex was determined by slope analysis method by plotting graph of logD [Ru(III)] versus logC [2-OAP] and logD [Ru(III)] versus logC [succinate]. The interference of various cations and anions has been studied in detail and the statistical evaluations of the experimental results are reported. The method was successfully applied for the analysis of ruthenium in various catalysts, synthetic mixtures corresponding to the composition of alloys and minerals.  相似文献   

11.
Donaldson EM  Wang M 《Talanta》1986,33(1):35-44
The methyl isobutyl ketone extraction of 15 elements (Cu, Ag, Zn, Cd, In, Tl, Ge, Sn, As, Sb, Bi, Se, Te, Mo and Pd) as iodide complexes from 0.1-5 M sulphuric acid/0.01-0.5M potassium iodide media has been studied. At the optimum potassium iodide concentrations, and a 1:2 v v ratio of organic to aqueous phase, Cu(II), Ag, Cd, In(III), Tl(III), Sb(III), Bi, Te(IV) and palladium(II) are completely extracted in a single step from 1-5M sulphuric acid. All these elements except palladium are also quantitatively extracted from 0.05-0.5M iodide/2M sulphuric acid. Zn, Sn(IV) and As(III) are completely extracted at high acid and iodide concentrations, and at the highest concentrations of acid and iodide investigated, Ge is partly extracted and Mo(VI) is slightly extracted. The extraction of Se(IV) is incomplete because of its reduction to the elemental state by iodide. The back-extraction of the elements has also been investigated and the forms in which they are extracted and potential analytical separations and interferences are discussed.  相似文献   

12.
Anuse MA  Mote NA  Chavan MB 《Talanta》1983,30(5):323-327
The solvent extraction separation of Pt(IV), Pd(II), Os(VIII), Ru(III) and Au(III) from one another and also from Rh(III) and Ir(III) with 1-(2'-nitro-4'-tolyl)-4,4,6-trimethyl-(1H, 4H)-2-pyrimidinethiol has been investigated. Photometric procedures have been developed for the determination of Pd(II), Os(VIII) and Ru(III) with the same reagent. The reagent allows the enrichment of Pd(II) and Au(III) at the trace level from a large volume of aqueous medium even in the presence of base metals. The method can be used for the determination of platinum metals and gold in alloys.  相似文献   

13.
采用含N、S功能团的螯合树脂YPA_4富集铂族元素和金。Au、Pt、Pd、Os的吸附率为98%以上,Ir为92%,Ru为90%,Rh为87%。把树脂灰化,用激光将其灰份气化输入等离子体激发,光谱测定。取样5g时,可测定0.2ng/g的Au,0.6ng/g的Os、Ir,0.06ng/g的Pt、Pd、Rh、Ru。标样分析结果与标准植吻合。  相似文献   

14.
The method of normal phase high-performance liquid chromatography has been applied to the separation and determination of Pd(II), Pt(II), Rh(III), Ir(IV), Ru(III) and Os(IV) as chelates with 8-hydroxyquinoline on a 62 x 2 mm column packed with Silasorb 600 5 mu silica gel by elution with methylene chloride-isopropyl alcohol mixture (97:3 v/v). The detection limits (ng per 5 mul), were Pd 0.3, Pt 1.0, Rh 1.0, Ir 5.0, Ru 1.5, Os 25. The separation time was 12 min at a flow-rate of 0.1 ml/min.  相似文献   

15.
Donaldson EM 《Talanta》1976,23(6):417-426
The solvent extraction of metal xanthates is reviewed with emphasis on the characteristics and analytical uses of ethyl xanthate complexes. Elements reviewed include As, Sb, Bi, Cd, Co, Cu. Cr, Ga, Au, In, Fe, Pb, Mn, Hg, Mo, Ni, Pd, Pt, Re, Ag, Se, Te, Tc, Tl, Sn, U, V and Zn.  相似文献   

16.
An imidazoline group-containing chelating fiber was prepared by means of the reaction of nitrile groups with ethylenediamine in an hydrazine-modified polyacrylonitrile fiber. The adsorption properties of the chelating fiber for Au(III), Pd(II), Pt(IV), Ir(IV), Os(IV), Rh(III) and Ru(IV) ions, such as binding capacity, distribution coefficient, sorptive rate and quantitative elution of Au(III), Pd(II) and Pt(IV) ions were investigated. The imidazoline group-containing chelating fiber possessed high binding capacities and good adsorption kinetic properties, exhibited high affinity for noble metals in 0.1-1.0 mol/L HCl and could be efficiently re-used. After the separation of trace Au(III), Pd(II) and Pt(IV) ions from a matrix using the chelating fiber, these ions could be determined by ICP-AES with satisfactory results, and the relative standard deviation for Au(III), Pd(II) and Pt(IV) ions was less than 6%.  相似文献   

17.
A study has been made of the sorption of Ir(IV), Rh(III), Pt(IV), Ru(IV), Os(VIII), Pd(II) and Au(III) from aqueous solutions by silica chemically modified with nitrogen-containing organic ligands, as a function of hydrochloric acid concentration, time of contact, concentration of the element and the ionic strength. Sorption of noble-metal ions at pH > 1 on a sorbent containing monoamine groups seems to be due to a complexation mechanism, and to an anion-exchange mechanism at pH < 1. With aminopropyl-silica 1000-fold concentration of Ir(IV) and Rh(III) from their 10(-8)-10(-7)M solutions was achieved and these metals were subsequently determined on the sorbent surface by X-ray fluorescence. Detection limits were 10-20 ng/ml. There was no interference from 1000-fold quantities of non-ferrous metal ions and Fe(III). With the sorbent containing bonded diethylenetriamine groups, 1000-fold concentration of Au(III) was achieved, and it was then determined on the sorbent surface by an atomic-emission method. Conditions for desorption of Au(III) with pyridine and potassium thiocyanate were developed.  相似文献   

18.
Strelow FW 《Talanta》1980,27(3):231-236
Gallium can be separated from Zn, Cu(II), In, Cd, Pb(II), Bi(III), Au(III), Pt(IV), Pd(II), Tl(III), Sn(IV) and Fe(III) by elution of these elements with 0.50M hydrobromic acid in 80% acetone medium, from a column of AG50W-X4 cation-exchange resin. Gallium is retained and can be eluted with 3M hydrochloric acid. Separations are sharp and quantitative except for iron(III) which shows extensive tailing. With 0.20M hydrobromic acid in 80% acetone as eluting agent, all the species above except iron(III) and copper(II) can be separated from gallium with very large separation factors. Only a 1-g resin column and small elution volumes are required to separate trace amounts and up to 0.5 mmole of gallium from more than 1 g of zinc or the other elements. Hg(II), Rh(III), Ir(IV), Se(IV), Ge(IV), As(III) and Sb(III) have not been investigated, but should be separated together with zinc according to their known distribution coefficients. Relevant elution curves, results for the analysis of synthetic mixtures and for amounts of some elements remaining in the gallium fraction are presented.  相似文献   

19.
An imidazoline group-containing chelating fiber was prepared by means of the reaction of nitrile groups with ethylenediamine in an hydrazine-modified polyacrylonitrile fiber. The adsorption properties of the chelating fiber for Au(III), Pd(II), Pt(IV), Ir(IV), Os(IV), Rh(III) and Ru(IV) ions, such as binding capacity, distribution coefficient, sorptive rate and quantitative elution of Au(III), Pd(II) and Pt(IV) ions were investigated. The imidazoline group-containing chelating fiber possessed high binding capacities and good adsorption kinetic properties, exhibited high affinity for noble metals in 0.1–1.0 mol/L HCl and could be efficiently re-used. After the separation of trace Au(III), Pd(II) and Pt(IV) ions from a matrix using the chelating fiber, these ions could be determined by ICP-AES with satisfactory results, and the relative standard deviation for Au(III), Pd(II) and Pt(IV) ions was less than 6%. Received: 5 July 1999 / Revised: 4 October 1999 / Accepted: 4 October 1999  相似文献   

20.
Yatirajam V  Ram J 《Talanta》1974,21(6):439-443
A simple and selective extraction of molybdenum is described. Tungsten is masked with tartaric acid and molybdenum(VI) is reduced in 2M hydrochloric acid by boiling with hydrazine sulphate. Iron, copper and vanadium are then masked with ascorbic acid, thiourea and potassium hydrogen fluoride respectively. The molybdenum(V) is extracted as its xanthate complex into chloroform, from 1M hydrochloric acid that is 0.4M potassium ethyl xanthate. The complex is decomposed by excess of liquid bromine, and the molybdenum is stripped into alkaline hydrogen peroxide solution. The molybdenum is then determined by standard methods. Large amounts of Cu(II), Mn(II), Fe(III), Ti(IV), Zr, Ce(IV), V(V), Nb, Cr(VI), W(VI), U(VI), Re(VII) and Os(VIII) do not interfere. Several synthetic samples and ferromolybdenum have been rapidly and satisfactorily analysed by the method.  相似文献   