首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 10 毫秒
1.
Monolithic capillary columns were prepared by copolymerization of styrene and divinylbenzene inside a 200 microm i.d. fused silica capillary using a mixture of tetrahydrofuran and decanol as porogen. Important chromatographic features of the synthesized columns were characterized and critically compared to the properties of columns packed with micropellicular, octadecylated poly(styrene-co-divinylbenzene) (PS-DVB-C18) particles. The permeability of a 60 mm long monolithic column was slightly higher than that of an equally dimensioned column packed with PS-DVB-C18 beads and was invariant up to at least 250 bar column inlet pressure, indicating the high-pressure stability of the monolithic columns. Interestingly, monolithic columns showed a 3.6 times better separation efficiency for oligonucleotides than granular columns. To study differences of the molecular diffusion processes between granular and monolithic columns, Van Deemter plots were measured. Due to the favorable pore structure of monolithic columns all kind of diffusional band broadening was reduced two to five times. Using inverse size-exclusion chromatography a total porosity of 70% was determined, which consisted of internodule porosity (20%) and internal porosity (50%). The observed fast mass transfer and the resulting high separation efficiency suggested that the surface of the monolithic stationary phase is rather rough and does not feature real pores accessible to macromolecular analytes such as polypeptides or oligonucleotides. The maximum analytical loading capacity of monolithic columns for oligonucleotides was found to be in the region of 500 fmol, which compared well to the loading capacity of the granular columns. Batch-to-batch reproducibility proved to be better with granular stationary phases compared to monolithic stationary phase, in which each column bed is the result of a unique column preparation process.  相似文献   

2.
Monolithic macroporous poly(styrene-co-divinylbenzene) stationary phases have been prepared by free radical polymerization within the confines of 4.6-mm I.D. chromatographic columns. The optimized porous properties allow the mobile phase to flow through these columns at flow-rates of up to 10 ml/min. As opposed to the simultaneously tested columns packed with either silica or synthetic polymer beads, the monoliths exhibit only modest back pressure. The monolithic columns were able to separate mixtures of peptides and proteins in a very short time. Under the optimized conditions, the separation of five proteins can be easily achieved in less than 20 s.  相似文献   

3.
The main factors affecting the porosity of methacrylate-ester based monolithic columns were investigated. We prepared 23 monolithic capillary columns with porosity controlled by varying the proportions of butyl methacrylate and ethylene dimethacrylate monomers and of 1,4-butanediol and 1-propanol as the porogen solvent in the polymerization mixtures by thermally initiated in-situ polymerization in fused-silica capillaries. Using mixture design software, we systematically varied the composition of the polymerisation mixtures to find significant factors affecting flow-through pore formation. Multivariate analysis of the experimental data obtained for the fabricated columns yielded a model for prediction of the flow-through porosity in monolithic beds as a function of the composition of the polymerization mixture used to prepare polymethacrylate monolithic capillary columns. The mean error of prediction was lower than 8% for eight columns prepared independently of the original set of 15 columns used to derive the flow-through model. The flow-through porosity increases with increasing concentration of the binary porogen solvent mixture, the concentration of 1,4-butanediol being the main factor enhancing flow-through pore formation. On the other hand, increasing concentrations of the hydrophobic monomer butyl methacrylate and increasing concentrations of 1-propanol have a negative effect on flow-through pore formation. The capillary columns prepared with a high proportion of flow-through pores and a minimum amount of mesopores can be used for fast gradient separations of both low-molecular weight compounds and biopolymers.  相似文献   

4.
The morphology of organic monolithic stationary phases based on poly(styrene-divinylbenzene) was modified by changing the ratio of monomers to microporogen in order to make them also suitable for small molecule separations. The morphology of the columns was characterized by high-resolution scanning electron micrography, showing larger primary globules and larger macropores, as well as no mesopores >20 nm in the monolithic skeleton. The permeability of the modified monoliths was approximately three times higher than that of columns which have been optimized for large molecule separations, enabling operation of a 30 cm long column at pressures below 250 bar. In the isocratic separation of dansylated amino acids, plate counts of 50000–107000 m−1 were achievable, which are equivalent to efficiencies obtained with 3.1 μm porous particles. The separation performance for small molecules in gradient elution was investigated using mixtures of dansylated amino acids, β-lactam antibiotics, and thyroid hormones. Finally, the modified monolithic capillary columns also proved to be highly efficient in the separation of biopolymers such as peptides and proteins, enabling peak width at half height of 3–8 s and peak capacities of 110–180 in 15–30 min gradient runs.  相似文献   

5.
Tightly cross-linked poly(styrene-co-divinylbenzene) microgels with molecular weights in the range 107 to 108 g mole?1 were studied in solution in dimethylformamide containing 7 g dm?3 LiBr. Laser light scattering photon correlation spectroscopy (PCS) was used to measure z-average translational diffusion coefficients D?z and dilute solution viscometry to measure intrinsic viscosities [η]; values of the equivalent hydrodynamic radii 〈R η ? and 〈RD?1〉 were derived. Weight-average molecular weights M?w and z-average mean-square radii of gyration 〈S2z were determined by conventional light scattering. The microgels were investigated by gel permeation chromatography, and molecular weight data obtained using the [η]M calibration procedure were in satisfactory agreement with results obtained by electron microsocopy and conventional light scattering.  相似文献   

6.
Hydrophobic organo-silane based monolithic capillary columns were prepared by thermally initiated free radical polymerisation within the confines of 200 microm i.d. fused silica capillaries. A novel crosslinker, namely bis(p-vinylbenzyl)dimethylsilane (BVBDMS), was copolymerised with p-methylstyrene (MS) in the presence of 2-propanol and toluene, using alpha,alpha'-azoisobutyronitrile (AIBN) as initiator. Monolithic capillary columns, differing in the total monomer, microporogen content and microporogen nature were fabricated and the chromatographic efficiency of each monolith, regarding the separation of proteins, peptides and oligonucleotides, was evaluated and compared. Changes in monolith morphology were monitored by scanning electron microscopy (SEM). Porosity and specific surface areas of the supports were studied by means of mercury intrusion porosimetry and BET measurements, respectively. Pressure drop vs. flow rate measurements proved the prepared poly(p-methylstyrene-co-bis(p-vinylbenzyl)dimethylsilane) (MS/BVBDMS) monoliths to be mechanically stable and swelling propensity (SP) factors of 0.78-1.10 indicate high crosslinking homogeneity.  相似文献   

7.
Macroporous poly(styrene-co-divinylbenzene) particles were produced in a micron-size range by two-stage swelling and continuous polymerization. The molecular weight of the polystyrene seed particles was controlled by incorporating a urethane acrylate. It was found that the porosity of the particles produced by the seeded polymerization was dependent on the molecular weight of the seed polymer. As the molecular weight of the polystyrene seed increased, the porous particles produced became macroporous. Interestingly, the high molecular weight of the polystyrene seed had a negligible influence on the change of porosity of the seeded polymerized particles. It is believed that the viscosity of the swollen droplet phase remained pretty high with the change in composition because the polystyrene seed copolymerized with urethane cacrylate had many side chains. Received: 16 December 1999 Accepted: 9 August 2000  相似文献   

8.
Divinylbenzene polymer monolithic capillary columns were prepared on the basis of capillaries 0.01 to 0.53 mm in diameter. Separation properties of the columns were investigated with the use of a test mixture of light hydrocarbons. The permeability and C parameter in the Van Deemter equation were determined for all the columns. For the most part, the columns had similar characteristics: permeability was in the range (2.2 ± 0.2) × 10?9 cm2, with parameter C in the range (0.7 ± 0.2) × 10?3 s (with n-butane as a sorbate). It was thus established that capillary diameter has only a slight effect on the efficiency of monolithic capillary columns (unlike packed capillary columns and microcolumns, whose properties, according to the literature data, depend strongly on the column diameter). The difference in properties between the narrowest monolithic column (capillary diameter 0.01 mm) and the others is explained by column overloading.  相似文献   

9.
A new phosphorus-modified poly(styrene-co-divinylbenzene) chelating resin (PS–N–P) was synthesized by P,P-dichlorophenylphosphine oxide modified commercially available ammoniated polystyrene beads, and characterized by Fourier transform infrared spectroscopy and elemental analysis. The adsorption properties of PS–N–P toward U(VI) from aqueous solution were evaluated using batch adsorption method. The effects of the contact time, temperature, pH and initial uranium concentration on uranium(VI) uptake were investigated. The results show that the maximum adsorption capacity (97.60 mg/g) and the maximum adsorption rate (99.72 %) were observed at the pH 5.0 and 318 K with initial U(VI) concentration 100 mg/L and adsorbent dose 1 g/L. Adsorption equilibrium was achieved in approximately 4 h. Adsorption kinetics studied by pseudo second-order model stated that the adsorption was the rate-limiting step (chemisorption). U(VI) adsorption was found to barely decrease with the increase in ionic strength. Equilibrium data were best modeled by the Langmuir isotherm. The thermodynamic parameters such as ?G 0, ?H 0 and ?S 0 were derived to predict the nature of adsorption. Adsorbed U(VI) ions on PS–N–P resin were desorbed effectively (about 99.39 %) by 5 % NaOH–10 % NaCl. The synthesized resin was suitable for repeated use.  相似文献   

10.
Following current trends in miniaturization of analytical chemistry, an inexpensive disposable analytical tool in the form of a liquid chromatography column fabricated on a poly(dimethyl siloxane) (PDMS) chip was created. Ease of fabricating the chromatography column was demonstrated by molding collocated monolithic support structures (COMOSS) directly in the column. Positive photo-resist, SPR 220, was used to create column structures on a negative relief master providing final channel dimensions of 2.7-5.2 microm wide by 10.0 microm deep, while monolithic dimensions were 9.8 x 9.8 x 10.0 microm - 12.3 x 12.3 x 10.0 microm. The ability to separate biological samples such as peptides from a tryptic digest of fluorescein isothiocyanate labeled bovine serum albumin (FITC-BSA) was shown. Separations in capillary electrochromatographic (CEC) mode were performed yielding column efficiencies of 4.0 x 10(5) plates/m.  相似文献   

11.
The production of beads with cross-link density varying from the centre to the surface is described.  相似文献   

12.
This study describes the ability of on-line concentration capillary electrochromatography (CEC) coupled with UV or mass spectrometry (MS) for the determination of nine common non-steroidal anti-inflammatory drugs (NSAIDs) in water samples. A series of poly(stearyl methacrylate-divinylbenzene) (poly(SMA-DVB)) monolithic columns, which were prepared by single step in situ polymerization of divinylbenzene (DVB), stearyl methacrylate (SMA) and vinylbenzenesulfonic acid (VBSA, charged monomer), were developed as separation columns for the first time. The effects of polymerization condition of monolithic columns on analyte separations were examined, and the results indicated that separation performances were markedly improved in monolithic columns prepared with short reaction time (3 h) and low SMA:DVB ratio (40/60 ratio of SMA:DVB). Subsequently, an on-line concentration step of step-gradient elution was combined to this CEC system, and by optimizing the difference in eluent strength between the sample matrix and mobile phase, all NSAIDs detection sensitivity were improved (limit of detection (LOD) was 3.4-10 μg/L for UV, and 0.01-0.19 μg/L for MS). When compared to the best CE and LC reports on NSAIDs analyses so far, this on-line concentration CEC method provided better detection ability within shorter separation time (12 min) when either UV or MS detector was employed. This is the first report for on-line concentration CEC with MS detection applied in trace solute analyses of real samples.  相似文献   

13.
Monolithic silica capillary columns for hydrophilic interaction liquid chromatography (HILIC) were prepared by on-column polymerization of acrylic acid on monolithic silica in a fused silica capillary modified with anchor groups. The products maintained the high permeability (K=5 x 10(-14)m(2)) and provided a plate height (H) of less than 10 microm at optimum linear velocity (u) and H below 20 microm at u=6mm/s for polar solutes including nucleosides and carbohydrates. The HILIC mode monolithic silica capillary column was able to produce 10000 theoretical plates (N) with column dead time (t(0)) of 20s at a pressure drop of 20 MPa or lower. The total performance was much higher than conventional particle-packed HILIC columns currently available. The gradient separations of peptides by a capillary LC-electrospray mass spectrometry system resulted in very different retention selectivity between reversed-phase mode separations and the HILIC mode separations with a peak capacity of ca. 100 in a 10 min gradient time in either mode. The high performance observed with the monolithic silica capillary column modified with poly(acrylic acid) suggests that the HILIC mode can be an alternative to the reversed-phase mode for a wide range of compounds, especially for those of high polarity in isocratic as well as gradient elution.  相似文献   

14.
Macroporous poly(styrene-divinylbenzene) monolithic columns were prepared in fused silica capillaries of 100 microm id by in-situ copolymerization of styrene with divinylbenzene in the presence of propan-1-ol and formamide as the porogen system. The monoliths were subsequently alkylated with linear alkyl C-18 groups via Friedel-Crafts reaction to improve the retention and chromatographic resolution of strongly polar phenolic acids. A new thermally initiated grafting procedure was developed in order to shorten the time of the alkylation process. The grafting procedure was optimized with respect to the reaction temperature, time, the grafting reactant concentration, and the solvent used. The type of solvent and the grafting temperature are the most significant factors affecting the hydrodynamic properties, porosity, and efficiency of the columns. While the equivalent particle diameter of the grafted column increased, the capillary-like flow-through pore diameter decreased in comparison to non-alkylated monoliths. The hydrodynamic permeability of the monolith decreased, but the monolithic column still permitted fast micro-HPLC separations.  相似文献   

15.
A novel method was developed for the preparation of highly efficient anion- and cation-exchange microHPLC columns using an on-column polymerization of methacrylates having amine or sulfonic acid functional groups onto monolithic silica capillary columns modified with 3-methacryloxypropyltriethoxysilane as the anchor groups. The chromatographic evaluation of the columns using nucleic acids, nucleotides, and inorganic anions as samples showed the characteristics of the ion-exchange-type stationary phases. These columns exhibited higher separation efficiency when compared with the conventional particle-packed columns. A capillary column for the simultaneous anion- and cation-exchange separation could be prepared by a step-by-step functionalization. The advantages of this column preparation will include: (1) no need of column packing; (2) no need of the preparation of silane reagents possessing anion- and cation-exchange functionalities; (3) the amount of immobilized polymer could be controlled by changing polymerization conditions. These columns should be suitable for the separation of biologically active compounds by the microHPLC modes.  相似文献   

16.
Monolithic capillary columns were prepared by thermally initiated free radical polymerisation of phenyl acrylate (PA) and 1,4-phenylene diacrylate (PDA) in the confines of 200 microm I.D. fused silica capillaries. Polymerisation was performed in the presence of 2-propanol and tetrahydrofuran (THF) as inert diluents (porogens), using alpha,alpha'-azoisobutyronitrile (AIBN) as initiator. Morphology and porosity of the resulting monoliths were comprehensively studied by scanning electron microscopy (SEM), mercury intrusion porosimetry and inverse size-exclusion chromatography (ISEC). The novel poly(phenyl acrylate-co-1,4-phenylene diacrylate) (PA/PDA) monoliths showed high mechanical stability and were successfully applied to the separation of proteins and oligodeoxynucleotides, employing reversed-phase (RP) and ion-pair reversed-phase (IP-RP) conditions, respectively. Maximum loading capacities for cytochrome c and d(pT)(16) were evaluated and found to be in the region of 200 fmol. Batch-to-batch reproducibility was determined for three independently prepared PA/PDA monolithic capillary columns. Relative standard deviations (RSDs) of retention time (t(R)) of 0.7-1.6% for proteins and 0.2-2.5% for d(pT)(12-18) proved high reproducibility of the PA/PDA supports.  相似文献   

17.
Transport properties of cation-exchange membranes have been studied. The self-diffusion coefficients of sodium and chloride ions, the transport numbers of sodium ions and water, and the conductivities were measured in 0.1 M sodium chloride at 25°C. The concentration potentials were determined in the system 0.05/0.15 M sodium chloride.The membranes were prepared by sulphonation of oriented polyethylene (PE) film modified with 30 wt % of styrene—divinylbenzene copolymer (poly(St-co-DVB)). The copolymer was introduced by interpolymerization of the monomers within the film without its dissolution. A sequence of membranes having similar ion-exchange capacity but differing in water content was then obtained from sheets of normal PE/poly(St-co-DVB)SO3Na membranes by expanding them by heating in water followed by a thermal treatment in air.The deviations of the measured transport properties from the behaviour of homogeneous membranes and the analysis of the Kedem—Katchalsky relationships for composite membranes have led to the conclusion that in PE/poly(St-co-DVB)SO3Na membranes a structure prevails with a series arrangement of layers with different properties.  相似文献   

18.
19.
SynthesisofPoly(styrene┐co┐divinylbenzene)┐supportedDichloroCyanuricAcidZHONGJing-fang*,LIChen-xi,HEBing-linandWUZhi-zhong(St...  相似文献   

20.
Short-term polymerization or the so-called low-conversion polymerization was applied for the preparation of N-vinylcarbazole (NVC) and 1,4-divinylbenzene (DVB) monolithic capillary columns. The synthesis was carried out by thermally initiated free radical copolymerization under the influence of inert micro- (toluene) and macroporogen (1-decanol) and α,α′-azoisobutyronitrile (AIBN) as radical initiator. The morphological and porous properties were studied by scanning electron microscopy (SEM), nitrogen adsorption, and mercury intrusion porosimetry (MIP). The copolymerization process was studied by monomer conversion measurements. This approach led to increased porosity and specific surface area. A specific surface area above 400 m2/g of the monolith and a distinct bimodal pore size distribution were obtained. The chromatographic performance was determined in terms of theoretical plate heights and number of theoretical plates. The lowest plate height value was found to be 3.9 μm (corresponding to ≈256,000 plates per meter) applying methylparaben utilizing an 80 mm?×?0.2 mm i.d. monolithic capillary. The developed NVC/DVB monolithic supports showed high separation efficiency towards small molecules, which was exemplified applying reversed-phase (RP) separation of alkylbenzenes, beta-blockers, flavanoids, parabens, and phenones. The loading capacity was analyzed for isocratic separation of seven alkylbenzenes and was found to be up to 77 ng total mass of alkylbenzenes. Furthermore, a long-term stability test of 1,000 consecutive runs was performed and resulted in a maximum variance of 0.97, 0.85, and 0.16 % RSD for resolution, peak width at half height, and retention times, respectively. The material was proven to have a high permeability of 1.11E?14 m2, applying water as a mobile phase.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号