Arja Sarpola Vesa Hietapelto Jorma Jalonen Jukka Jokela Risto S. Laitinen Jaakko Rämö 《Journal of mass spectrometry : JMS》2004,39(10):1209-1218
Earlier characterization of some hydrolysis products of AlCl3·6H2O was confirmed by electrospray ionization tandem mass spectrometry with increasing collision energy of projectile ions. At lower collision energies, the aqua ligands were stripped off. At higher energies, two hydroxo groups formed a bridging oxo group with loss of one water molecule. Aluminum complexes could also capture aqua ligands in the collision chamber so long as the parent ion did not fragment, and the fragment ion spectra broadened toward higher m/z values. The chloro ligands were eliminated as hydrochloric acid. The aluminum cores remained highly intact. Copyright © 2004 John Wiley & Sons, Ltd. 相似文献
2.
Flow injection analysis (FIA) with ESI-MS and ion chromatography (IC) with inductively coupled plasma-MS (ICP-MS) as the complementary technique have been explored for the determination of metal ions as their metal-EDTA complexes. ESI-MS enabled the identification of metal-EDTA complexes such as [Mn(EDTA)](2-), [Co(EDTA)](2-), [Ni(EDTA)](2-), [Cu(EDTA)](2-), [Zn(EDTA)](2-), [Pb(EDTA)](2-), and [Fe(EDTA)](1-) and their MS spectral showed that these metal-EDTA complexes were present in solution. Based on the ESI-MS, ion chromatographic separation and ICP-MS detection of these complexes are possible because IC-ICP-MS requires stable metal-EDTA complex during the chromatographic separation. The separation of these metal-EDTA complexes was achieved on an anion-exchange column with a mobile phase containing 30 mM NH(4)(HPO(4))(2) at pH 7.5 within 7 min with ICP-MS providing element specific detection. The ICP-MS LODs for the metal-EDTA were in the range of 0.1-0.5 microg/L with the exception of Fe (15 microg/L). The proposed method was a simple procedure for sample processing, using direct injection of sample without removal of sample matrix and was successfully applied to the determination of metal-EDTA complexes in real samples. 相似文献
3.
Osaka I Watanabe M Takama M Murakami M Arakawa R 《Journal of mass spectrometry : JMS》2006,41(10):1369-1377
Linear and cyclic polylactic acids (PLAs) were characterized using electrospray ionization mass spectrometry (ESI-MS) as part of our ongoing investigation of the hydrolysis mechanism of biodegradable polymers. The condensation oligomers of linear polylactic acid (LPLA) were synthesized by thermal dehydration of L-lactic acid. The trimer and tetramer base polymers of cyclic polylactic acid (CPLA) were obtained by cyclization reactions of lactic acid trimers and tetramers, respectively. In the ESI-MS/MS measurement, LPLA yielded three types of product ion series, while CPLA yielded only one type, from which the repeated units of CPLA were removed. The MS/MS spectrum of the NH4+ adduct ion for both cyclic and linear PLA showed loss of one ammonia molecule. The postsource decay (PSD) spectrum of CPLA by matrix-assisted laser desorption ionization (MALDI) mass spectrometry was similar to the ESI-MS/MS spectrum, while that of LPLA was different. In addition, the degradation of cyclic and linear PLAs by solvolysis was investigated. Solvolysis with anhydrous MeOH was quite feasible, but did not readily occur in the presence of even a small amount of water in the MeOH solvent. 相似文献
4.
Electrospray ionization mass spectrometry (ESI-MS) is being increasingly employed in the study of metal-ligand equilibria in aqueous solution. In the present work, the ESI-MS spectral changes due to different settings of the following instrumental parameters are analyzed: the solution flow rate (F(S)), the nebulizer gas flow rate (F(G)), the sprayer potential (E), and the temperature of the entrance capillary (T). Twenty-eight spectra were obtained for each of six samples containing aluminum(III) and 2,3-dihydroxypyridine at various pH, in the absence or in the presence of a buffer and of sodium ions. Among the considered instrumental parameters, T produced the largest effects on the ionic intensities. F(S) and F(G) affected the ESI-MS spectra to a lower extent than T. In the investigated conditions E had the weakest effects on the spectra.The correlations observed between the ionic intensities and these instrumental parameters were interpreted considering the presence of three kinds of perturbations occurring in the ESI-MS ion source: formation of some dimers in the droplets, different transfer efficiencies from the droplets to the gas phase for different complexes (according to their surface activity), and subsequent partial thermal decomposition of the dimers and of one of the monomeric complexes in the gas phase. Our results show that the evaluation of the effects produced in the ESI-MS spectra by a change of instrumental parameters can allow to identify the perturbations occurring when metal-ligand solutions are studied by ESI-MS. 相似文献
5.
M(NO(3))(x)(-) ions are generated by electrospray ionization (ESI) of metal solutions in nitric acid in negative ion mode. Collision-induced reactions of these ions are monitored in a tandem mass spectrometer (MS) of quadrupole-octopole-quadrupole (QoQ) geometry. For Group 1 and 2 elements, the M(NO(3))(x)(-) ions dissociate into NO(3)(-) and neutral metal nitrate molecules. These elements also form some M(x)(NO(3))x+1- clusters, especially Li(+). Metal nitrate ions from transition elements and Group 13 elements fragment into oxo products and also undergo internal electron transfer to leave the M atom in a lower oxidation state. To calibrate the collision energy, the dissociation energy of O-NO(2)(-) is found to be 5.55 eV, about 0.76 eV lower than a value derived from thermochemistry. The product ions from Fe(NO(3))(4)(-) ions have low formation thresholds of only 0.5 to 2 eV. 相似文献
6.
AlCl(3) solution was analyzed at concentrations from 0.02 to 100 mM using an electrospray ionization quadrupole mass spectrometer (ESI-Q-MS), and the dissolution state of aluminum ions is discussed. Results obtained using ESI-Q-MS were consistent with those obtained using (27)Al nuclear magnetic resonance ((27)Al NMR). Aluminum species existed mainly as positively charged monomeric aluminum hydroxide coordinated with several water molecules in solution. The complexation of chloride ions by aluminum ions differed between the positive and negative ion modes. Chemical reactions that partially modified chemical forms of species through ESI-Q-MS measurement were also observed. In the same aluminum chloride solution, using ESI-TOF-MS and ESI-Q-MS/MS studies, the disagreement of the reports is discussed. It is concluded that ESI-TOF-MS might show also the gas-phase reaction in the mass spectrometer but the dissolution state of aluminum species can be shown by ESI-Q-MS. 相似文献
7.
8.
Fragmentation pathways of a series of pentacoordinated bisaminoacylspirophosphoranes were elucidated by electrospray ionization multistage mass spectrometry (ESI-MS(n)) in negative mode. The deprotonated ions of pentacoordinated bisaminoacylspirophosphoranes tend to eliminate a corresponding amino acid to form base peak. The hydrogen/deuterium exchange experiment, the high-resolution mass spectrometry, (13)C stable isotope labeling experiment and theoretical calculations were used to rationalize the proposed fragmentation pathways and to verify the differences between the fragmentation pathways. The results indicate that the negative molecular ions of pentacoordinated bisaminoacylspirophosphoranes dissociate through its open-chain tricoordinated tautomers. The relative Gibbs free energies (ΔG) of the product ions and proposed fragmentation pathways were estimated using the B3LYP/6-31 + + G(d, p) model. The results have some potential applications in the identification structures of similar spirophosphorane compounds by ESI-MS(n). 相似文献
9.
Tamar Shamai Yamin Hagit Prihed Moran Madmon Merav Blanca Avi Weissberg 《Journal of mass spectrometry : JMS》2020,55(10)
V‐nerve agents present information‐poor spectra, both in GC‐EI‐MS and LC‐ESI‐MS/MS, with dominant fragments/product ions corresponding to the amine‐containing residue. Hence, derivatives/isomers with the same amine residue exhibit similar mass spectral patterns, leading to ambiguity in the phosphonate structure. We present a simple approach for their structural elucidation based on two complementary experiments: ESI‐MS/MS of the original compound, which provides information about the amine moiety, and ESI‐MS/MS of the phosphonic acid hydrolysis products generated by N‐iodosuccinimide, which provides ions' characteristic of the phosphonate structure. This approach enables the structural elucidation of the original V‐agents with a higher degree of certainty. 相似文献
10.
Branched polyethylenimines (PEIs) with lower average molecular weights (600, 1200 and 1800 Da) have been studied by Electrospray Ionization (ESI) and Matrix‐Assisted Laser Desorption/Ionization (MALDI) mass spectrometry. In both, ESI and MALDI mass spectra, the main distribution arises from protonated PEI oligomers with NH2 end groups, [PEI + H]+, which are observed at m/z 43n + 18. A trace of sodium contamination in the PEI samples results in the presence of a series that appears at m/z 43n + 40 [PEI + Na]+. However, only the MALDI mass spectra show a [PEI + K]+ series at m/z 43n + 56, because of matrix contamination with potassium, and a series generated by condensation of the matrix with PEI at m/z 43n + 30. Collisionally activated dissociation tandem mass spectrometry (CAD (MS/MS)) of protonated PEI oligomers is shown to yield three fragment ion series bn, and Kn. The experiments have demonstrated the capabilities of these mass spectrometry techniques, along with CAD MS/MS to detect and characterize such polar synthetic polymers. Copyright © 2011 John Wiley & Sons, Ltd. 相似文献
11.
A fast and sensitive ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed for the determination of lovastatin in human plasma. With simvastatin as internal standard, sample pretreatment involved one-step extraction with n-hexane-methylene dichloride-isopropanol (20:10:1, v/v/v) of 0.5 mL plasma. Chromatographic separation was carried out on an Acquity UPLC BEH C(18) column with mobile phase consisting of acetonitrile-water (containing 5 mmol/L ammonium acetate; 85:15, v/v) at a flow-rate of 0.35 mL/min. The detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) via electrospray ionization source with positive mode. The analysis time was shorter than 1.7 min per sample. The standard curve was linear (r2>or=0.99) over the concentration range 0.025-50.0 ng/mL with a lower limit of quantification of 0.025 ng/mL. The intra- and inter-day precision values were below 11% and the accuracy (relative error) was within 6.0% at three quality control levels. This is the first method of MS with MRM coupled to UPLC for the determination of lovastatin, which showed great advantages of high sensitivity, selectivity and high sample throughput. It was fully validated and successfully applied to the pharmacokinetic study of lovastatin tablets in healthy Chinese male volunteers after oral administration. 相似文献
12.
Smith SI Guziec LJ Guziec FS Hasinoff BB Brodbelt JS 《Journal of mass spectrometry : JMS》2007,42(5):681-688
Binding interactions of a new series of anthrapyrazoles (APs) with DNA were evaluated by electrospray ionization mass spectrometry (ESI-MS). Relative binding affinities were estimated from the ESI-MS data based on the fraction of bound DNA for DNA/anthrapyrazole mixtures, and they show a correlation to the shift in melting point of the DNA measured from a previous study. Minimal sequence specificity was observed for the series of anthrapyrazoles. Upon collisionally activated dissociation of the duplex/anthrapyrazole complexes, typically ejection of the ligand was the dominant pathway for most of the complexes. However, for complexes containing AP2 or mitoxantrone, strand separation with the ligand remaining on one of the single strands was observed, indicative of a different binding mode or stronger binding. 相似文献
13.
Xiang Gao Feng Ni Jian Bao Yan Liu Zhen Zhang Pengxiang Xu Yufen Zhao 《Journal of mass spectrometry : JMS》2010,45(7):779-787
The fragmentation reactions of N‐monoalkyloxyphosphoryl amino acids (N‐MAP‐AAs) were studied by electrospray ionization tandem mass spectrometry (ESI‐MS). The sodiated cyclic acylphosphoramidates (CAPAs) were formed through a characteristic pentacoordinate phosphate participated rearrangement reaction in the positive‐ion ESI‐MS/MS and HR‐MS/MS of N‐MAP‐AAs, in which the fragmentation patterns were clearly different from those observed in the corresponding ESI‐MS/MS of N‐dialkyloxyphosphoryl amino acids/peptides and N‐phosphono amino acids. The formation of CAPAs depended on the chemical structures of N‐terminal phosphoryl groups, such as alkyloxy group, negative charge and alkali metal ion. A possible integrated rearrangement mechanism for both P‐N to P‐O phosphoryl group migration and formation of CAPAs was proposed. The fragmentation patterns of CAPAs as novel intermediates in gas phase were also investigated. In addition, it was found that the formation of α‐amino acid CAPAs was more favorable than β‐ or γ‐CAPAs in gas phase, which was consistent with previous solution‐phase experiments. Copyright © 2010 John Wiley & Sons, Ltd. 相似文献
14.
In this study, electrospray ionization mass spectrometry (ESI-MS) is used to study the formation of G-quadruplex by d(GGAGGAGGAGGA) which locates at the promoter region of c-myb gene. In addition, a natural small molecule, dehydrocorydaline from a Chinese herb, is found to have the highest binding affinity with the G-quadruplex in nine natural small molecules studied, and the binding selectivity of this natural molecule toward the c-myb G-quadruplex with respect to corresponding duplex DNA is significantly higher than that of the broad-spectrum G-quadruplex-ligand TMPyP4. The result from ESI-MS indicates that the gas-phase kinetic stability of the G-quadruplex can be enhanced by binding of dehydrocorydaline. To further investigate the binding properties of dehydrocorydaline to the G-quadruplex, Autodock3 is used to calculate the docked sites and docked energies of small molecules binding to the G-quadruplex and the result shows that the docked energy of dehydrocorydaline is the biggest in the nine small molecules used, consistent with the result from ESI-MS. 相似文献
15.
A reliable and rapid method based on rapid-resolution liquid chromatography-diode array detection (RRLC-DAD) and electrospray ionization time-of-flight mass spectrometry (ESI-TOF/MS) has been developed for the isolation and characterization of multiple constituents in the root of Stellera chamaejasme L., which was extracted by sonication with methanol in an optimized procedure. Separation of the multiple constituents was achieved on an Agilent Zorbax XDB-C18 (50x3.0 mm i.d.; 1.8 microm) column using a gradient elution at a flow rate of 0.4 mL/min. The detection wavelength was 210 nm. Mass spectra were acquired in both positive and negative modes. A formula database of the known chemical constituents in the root of Stellera chamaejasme L. was established by an Agilent software. Twenty-two obvious peaks appeared in the total ion chromatogram and nine of them were characterized by TOF/MS. The RRLC-DAD and ESI-TOF/MS method with ultrasonic extraction would be useful for rapid and effective characterization of chemical constituents in the root of Stellera chamaejasme L. 相似文献
16.
Hydrophilic interaction liquid chromatography (HILIC) is here successfully coupled to negative-ion electrospray ionization time-of-flight mass spectrometry (ESI-TOFMS) for the analysis of synthetic and chemically modified oligonucleotides. Separation was performed on a 2.1 mm × 100 mm PEEK ZIC® HILIC column packed with hydrophilic stationary phase with a permanent zwitterionic functional group and a particle size of 3.5 μm with an average pore diameter of 200 Å. A method was developed to separate homogeneous and heterogeneous oligonucleotides as well as methylated oligonucleotides using a quaternary pumping system containing ammonium acetate and water with an acetonitrile gradient. Analyses of oligonucleotides were performed by LC/MS with a detection limit of 2.5 picomole (20 mer) with signal to noise ratio (S/N) of 4.12. The influence of the eluent composition, type of buffer and its concentration, and organic modifier were also evaluated. The HILIC LC/MS method presented in this paper used common, ‘MS friendly’, mobile phases achieving sensitive and selective oligonucleotide analysis. 相似文献
17.
Osaka I Kondou M Selvapalam N Samal S Kim K Rekharsky MV Inoue Y Arakawa R 《Journal of mass spectrometry : JMS》2006,41(2):202-207
When an intramolecular cavity exists in a molecule, it can trap another chemical species to form a host-guest complex. We examine the formation of such an inclusion complex with cucurbit[n]uril (CBn, n = 6, 7) as the host to trap alkali metal or ammonium ions as the guest, by electrospray ionization mass spectrometry (ESI-MS). The results show that the inclusion complexes are formed between the three-dimensional cylinder of CBn hosts and the guest cations. Selectivity of the complex formation is dependent both on (1) ion-dipole interactions between the cylindrical portal of the CBn hosts and the guest cations and (2) the hydrophobic interactions at the inner cavity of CBn. 相似文献
18.
《Journal of mass spectrometry : JMS》2017,52(9):591-596
Sartans and related analogues with 5‐oxo‐l, 2, 4‐oxadiazole ring and tetrazole ring are investigated in detail using collision‐induced dissociation (CID) method in positive ion mode by electrospray ionization tandem mass spectrometry (ESI‐MSn). It is found that the protonated sartans and related analogues tend to form the N‐substituted‐3‐substituted phenanthridin‐6‐amine ion which has a large conjugative structure. The possible fragmentation pathways were proposed for the first time, and the key structure of product ions was confirmed by high resolution tandem mass spectrometry and theoretical calculation. It is very helpful for understanding the intriguing roles of sartans analogues in fragmentation reactions and enriching the knowledge of the gas‐phase chemistry of the oxadiazole and tetrazole ring. Copyright © 2017 John Wiley & Sons, Ltd. 相似文献
19.
Barata JF Barros CM Santana-Marques MG Neves MG Faustino MA Tomé AC Ferrer Correia AJ Cavaleiro JA 《Journal of mass spectrometry : JMS》2007,42(2):225-232
Liquid secondary ion and electrospray mass spectrometry were used to study the complexation in-source of 5,10,15-tris(pentafluorophenyl)corrole with several divalent transition-metal ions. The metallocorrole ions formed in-source were identified by comparing their product ion mass spectra with the spectra of the same ions formed from metallocorroles obtained from classical procedures. Positive metallocorrole ion formation is accompanied by oxidation of the metal centre. Mechanisms were proposed for the oxidation processes, and data from negative-ion spectra reinforced these mechanisms. 相似文献
20.
Copper chloride anion clusters with both copper oxidation states can be made by laser desorption of CuCl(2) crystals. We have used this method to study the dissociation characteristics of such cluster ions. The stability and the structure of the observed complexes were probed by ab initio calculations. These calculations show that many of these complexes are bridged structures. Thus, for the Cu(2)Cl(4) dimer anion, formally [ClCu-Cl-CuCl(2)](-) , with putative mixed copper oxidation states, the two copper ions become equivalent through bridging. Such bridging does not occur when redox inactive metal ions are present as in [ClCu-Cl-CaCl(2)](-) . By observing the dissociation characteristics of a variety of metal chloride cluster anions produced from binary mixtures, the following Cl(-) affinity order is obtained: FeCl(3) > CuCl > CaCl(2) > FeCl(2) > AgCl ≈ CuCl(2) ≈ ZnCl(2) > LiCl. Ab initio calculations on the Cl(-) affinity of selected chlorides confirm this order as do Cl(-) affinity estimates from the experimentally known vertical electron detachment energies of the superhalogens CaCl(3)(-) and LiCl(2)(-) . An equimolar mixture of CuCl(2) and FeCl(3) produces an intense cluster ion, which, from (65)Cu labeling experiments, is best described as FeCl(4)(-)···Cu(+)···(-)Cl(4) Fe, a Cu(+) bound superhalogen FeCl(4)(-) dimer. The Cu(+) ion can be replaced by the redox inactive alkali cations and by Ag(+) but these metal ion bound FeCl(4)(-) dimers show an entirely different fragmentation behavior which is attributed to the absence of bridging. Electrospray ionization (ESI) of CuCl(2) produces an extended series of (CuCl(2))(n) Cl(-) anions (n = 1-11) and so in ESI very limited reduction of Cu(2+) takes place. The (CuCl(2))(n) Cl(-) anions show an abundant dissociation via loss of neutral Cu(2)Cl(4) which according to our ab initio calculations is 9 kcal/mol more stable than two CuCl(2). 相似文献