首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple method is described for the simultaneous determination of free and complexed copper ions in a flow-injection system comprising ion-exchange and flame atomic absorption spectrometry. Sampling rates for 400-μl samples were 90 h?1. Typical relative standard deviations for the simultaneous determinations were 1.6% for the complexed metal (0.50 μg ml?1) and 1.0% for the free metal (0.20 μg ml?1).  相似文献   

2.
Technetium is an effective quencher of the fluorescence produced by 2,5-diphenyloxazole (PPO), 1,4-bis(4-methyl-5-phenyl-2-oxazolyl)benzene (POPOP) and 2,2′-pyridil [1,2-dioxo-1,2-bis(2-pyridyl)ethane]. Spectrofluorimetric procedures for 0.01–12 μg Tc ml?1 with PPO and 0.1–12 μg ml?1 with 2,2′-pyridil, and a spectrophotometric method for 1–15 μg ml?1 are described. The distribution of technetium in vegetation is measured by applying the PPO method.  相似文献   

3.
《Analytical letters》2012,45(10):1705-1717
Abstract

The ternary fluorescent complexes of nucleic acids/8-hydroxyquinoline/ lanthanum (III) were studied. Nucleic acids in the study involve natured and thermally denatured calf thymus DNA, fish sperm DNA and yeast RNA. In the range of pH 8.0–8.4 (controlled by NH3-NH4Cl buffer) ternary fluorescent complexes are formed which emit at 485.0 nm for calf thymus DNA and at 480.0 nm for yeast RNA (when excited at 267.0 nm) and emits at 483.0 nm for fish sperm DNA when excited at 265.0 nm. Based on the fluorescence reactions sensitive fluorometric methods for nucleic acids were proposed. Using optimal conditions, the calibration curves were linear in the range of 0.4–3.6 μg˙ml?1 for calf thymus DNA, 0.4–4.0 μg-ml?1 for fish sperm DNA and 0.4–4.0 μg˙ml?1 for yeast RNA, respectively. The limits of determination (3σ) were 0.076 μg˙ml?1 for calf thymus DNA, 0.068 μg˙ml?1 for fish sperm DNA and 0.329 μg˙ml?1 for yeast RNA, respectively. Five synthetic samples were determined with satisfaction.

  相似文献   

4.
《Analytical letters》2012,45(11):2045-2058
Abstract

Two simple and sensitive spectrophotometric procedures are suggested for analysis of triamterene. The first procedure is based on the reaction of triamterene with p-chloranilic acid (p-CA) in methylene chloride to form a highly stable coloured product, exhibiting maximum absorbance at λ 530 nm. Beer's law is obeyed in the range of 40–220 μg.ml?1 with a mean percentage accuracy of 99.98 ± 0.446. Limit of determination is 20 μg.ml?1. In the second procedure, the drug is determined via charge transfer complex formation with 2,3 dichloro-5,6-dicyano p-benzoquinone (DDQ) using methylene chloride as a solvent. Here the reaction product has two well defined maxima at 460 nm and 530 nm where each has been utilized for quantitative determination. Beer's law is obeyed in concentration ranges of 25–125 μg.ml?1 and 25–150 μg.ml?1 with mean percentage accuracies of 99.92 ± 0.449 and 100.00 ± 0.511 for both maxima. 460 and 530 nm. respectively. Limit of determination is 12.5 μg.ml?1 at both maxima. Optimum conditions for each procedure have been studied and the stoichiometry of both reactions was ascertained using Job's method of continuous variation. The validity of the suggested procedures was assessed by applying the standard addition technique using the drug capsules. Both procedures are statistically analyzed as compared with BP method for analysis of triamterene (non aqueous titration) revealing good accuracy and precision as indicated by t and F tests.  相似文献   

5.
《Analytical letters》2012,45(12):2515-2531
ABSTRACT

Propofol is coupled with 2, 6-dichloroquinone-4-chlorimide (DCQ) in a reaction buffered at pH 9.6 to give a colored product having an analytically useful maximum at 635 nm. The factors affecting the color generation were optimized and incorporated in the procedure. The reacted propofol has a molar absorptivity of 3.9 × 10?4 L mol?1 cm?1, and Beer's law is obeyed for concentrations 1-5 μg ml?1 with detection limit 0.25 μg ml?1. The method was found applicable to biological fluids (plasma and urine) spiked with propofol at concentration levels 1-5 μg ml?1 for plasma and 1-5 μg 0.5 ml?1 urine (less sensitivity is obtained with urine volumes above 0.5 ml) with detection limits 0.28 μg ml?1 for plasma and 0.4 μg 0.5 ml?1 urine. The average recovery for the commercial preparation (1% w/v propofol emulsion intravenous injection for infusion) was 99.54% with an RSD of 1.05%. The method was validated by an adopted HPLC method. The results obtained by the HPLC method for the commercial preparation were statistically compared with the proposed method and evaluated at the 95% confidence limits.  相似文献   

6.
《Analytical letters》2012,45(12):2279-2288
Abstract

An integrated-sensor method for the determination of formaldehyde based on retention of the reaction product of the analyte with p-rosaniline and sulfite in a flow-cell packed with Dowex 1-X-8 anion exchange resin was developed. The method has a good selectivity with a detection limit of 0.3 μg ml?1 (1 ml sample) or 75 ng ml?1 (2 ml sample), and a linear range between 1–30 μg ml?1. The relative standard deviations (n = 11) were 2.8 and 1.3% for 2 and 20 μg ml?1 formaldehyde, respectively. Depending on the working conditions, the sampling frenquency ranged between 10 and 18 h?1. The method was applied to the determination of formaldehyde in well water.  相似文献   

7.
《Analytical letters》2012,45(12):2491-2500
ABSTRACT

A method for the simultaneous determination of valsartan and hydrochlorothiazide in tablets is described. The procedure, based on the use of reversed-phase high-performance liquid chromatography, is linear in the concentration range 5.0-10.0 μg ml?1 for valsartan and 0.5-2.0 μg ml?1 for hydrochlorothiazide, is simple and rapid and allows accurate and precise results. The limit of detection was 1.0 μg ml?1 for valsartan and 0.05 μg ml?1 for hydrochlorothiazide.  相似文献   

8.
A simple, rapid determination is reported for danthron (1,8-dihydroxyanthraquinone) in pharmaceutical tablets. In a flow-injection system, danthron is reduced by sodium dithionite in 11 methanol/borate buffer to give a fluorescent complex. Linearity ranges from 30 μg ml?1 to below 0.1 μg ml?1. In urine samples, danthron is separated from other fluorescing species by reversed-phase high-performance liquid chromatography before its reduction by dithionite in a post-column reactor. Urine preparation requires no extraction. Spiked urine samples were studied in the working range of 0.02–2.0 μg ml?1 danthron.  相似文献   

9.
Phthalimide dithiosemicarbazone forms a 1:1 complex with osmium at pH 3.3–4.5 (?450 = 1.3 · 104 l mol?1 cm?1 ) which is applied to the photometric determination of osmium; Beer's law is obeyed for the range 1–12 μg Os ml?1. The oxidation of the reagent with cerium(IV) is catalyzed by osmium(VIII), and this reaction allows a more sensitive procedure for the determination of osmium; the calibration curve is linear over the range 0.05–0.4 μg Os ml?1. The interferences in both procedures are described.  相似文献   

10.
A simple and sensitive method was developed for the analysis of preservatives sodium benzoate, methylparaben and propylparaben in nystatin suspensions by reversed-phase high performance liquid chromatography (HPLC), equipped with a C18 column and PDA detector. The mobile phase was a mixture of acetonitrile and acetate buffer of pH 4.4 (35:65 v/v). Under the optimized experimental conditions, separation of the preservatives was achieved in less than 20 min. The limits of quantifications (LOQs) and the linear dynamic ranges (LDRs) of sodium benzoate, methylparaben and propylparaben were 0.3 and 50–1000 μg Ml?1, 0.5 and 50–600 μg ml?1 and 0.3 and 50–900 μg ml?1, respectively; the respective precisions (%RSD) at 500 μg ml?1 level were 0.72%, 0.73% and 0.51% (n = 6). The average recoveries of sodium benzoate, methylparaben and propylparaben for spiked nystatin samples were obtained as 98%, 97% and 98%, respectively.  相似文献   

11.
Magnetic solid phase extraction (MSPE) based on cetyltrimethylammonium bromide (CTAB)-coated magnetic iron oxide nanoparticles (C-MIONPs) was investigated for the separation, preconcentration and determination of Rose Bengal (RB) in aqueous solutions. The influences of different analytical parameters such as pH, temperature, ionic strength, volume of desorbent solvent, amount of adsorbent and interfering ions in the adsorption of RB on C-MIONPs were investigated. The RB adsorption on C-MIONPs follows Langmuir isotherm. The sizes of C-MIONPs were in the range of 20–80 nm. The method was capable of determining RB concentration in the range of 0.01–1.20 μg ml?1. The limit of detection (LOD) of RB based on three times the standard deviation of the blank (3Sb) was found to be 5.91 × 10–3 μg ml?1 (n = 8). The relative standard deviation (RSD) for 0.3 μg ml?1 and 0.8 μg ml?1 of RB were 4.1% and 1.1%, respectively. The proposed method was applied to the determination of RB in Brucella Antigen solution and water samples from the Karoon River.  相似文献   

12.
The fluoroquinolone antibacterial agent ofloxacin was studied by adsorptive stripping voltammetry. Controlled interfecial accumulation of ofloxacin on a static mercury drop electrode in the hanging mercury drop mode provides high sensitivity. The linear concentration range was 0.079–197.5 μg ml?1 when using a 60-s preconcentration at ?1 V vs. Ag/AgCl in Britton-Robinson buffer of pH 6.00. The detection limit of ofloxacin was 1 ng ml?1. The precision is excellent with a relative standard deviation of ca. 0.75% at a concentration of 0.848 μg ml?1.  相似文献   

13.
A zinc reductor minicolumn is used in a flow-injection system for reduction of europium(III) to europium(II). Europium(II) is indirectly determined either spectrophotometrically by oxidation with iron(III) and reaction of the iron(II) formed with 1,10- phenanthroline, or spectrofluorimetrically by reaction with cerium(IV) and measurement of the cerium(III) produced. The reductor functions efficiently at flow rates up to 1 ml min?1, which allows sample injection rates up to 100 h?1. Linear calibration is achieved for 10–200 and 0.5–4 μg ml?1 with detection limits of 2.5 and 0.25 μg ml?1, by spectrophotometry and spectrofluorimetry, respectively.  相似文献   

14.
The method is based on a fluorescence reaction of the epoxy group with nicotinamide and 3-acetylpyridine. Oleandomycin phosphate and triacetyloleandomycin can be determined in the ranges 1–80 μg ml?1and 5–80 μg ml?1, respectively, with relative standard deviations of 3–5%. The method can be applied to pharmaceutical preparations. Results obtained by this method and by bioassay in an examination of residual potency agreed well when degradation was done under neutral or alkaline conditions.  相似文献   

15.
The method is based on the oxidation of L-ascorbic acid with potassium hexacyanoferrate (III). Excess of oxidant is determined spectrophotometrically by oxidation of phthalophenone to phenolphthalein in alkaline solution. Linear calibration graphs are obtained for 0–7 μg ml?1 ascorbic acid at 553 nm, with a detection limit of 0.1 μg ml?1. Sugars and other organic compounds do not interfere when present in moderate amounts.  相似文献   

16.
A rapid, simple spectrophotometric method for the determination of μg amounts of ruthenium, based on the formation of a pink complex between the metal and prochlorperazine maleate (PCPM) in sulphuric or hydrochloric acid solution, is described. The complex has an absorption maximum at 530 nm and its molar absorptivity is 6.733·103 l mol?1 cm?1. The sensitivity is 0.0151 μg Ru cm?2 for log Io/I = 0.001. Beer's law is valid over the range 0.2–10 μg Ru ml?1 ; the optimal range for spectrophotometric determination is 0.8–8.0 μg Ru ml?1. Job's method of continuous variation, the mole ratio method and the slope ratio method indicate a 1:1 composition for the complex. The effects of acidity, time, temperature, order of addition of reagents, reagent concentration, and the interferences from various ions are reported.  相似文献   

17.
The tetrahydrazide of ethylenediamine tetraacetic acid (NH2NH)4-EDTA was synthesized from the EDTA ester and hydrazine hydrate in ethanolic solution, the resulting (NH2NH)4-EDTA being recrystallized in 60% ethanol. When the spectrophotometric study of the iron(III) (NH2NH)4-EDTA complex in aqueous solution was made two absorption maxima at 530 and 450 nm at pH 4.5 and 11.0, respectively, were found. Beer's law is obeyed in the range 1.0–20.0 μg Fe(III) ml?1 at 530 nm and pH 4.5 and 0.5–12.0 μg Fe(III) ml?1 at 450 nm and pH 11.0, the molar absorptivities being 1.95 × 103 1 mol?1 cm?1 at 530 nm and 3.35 × 103 1 mol?1 cm?1 at 450 nm, respectively. The Ringbom optimal interval falls between about 3 and 18 μg Fe(III) ml?1 at 530 nm and about 2–14 μg Fe(III) ml?1 at 450 nm. The reaction between the metal and the ligand was also investigated. The method has been successfully applied to the determination of iron in talcs.  相似文献   

18.
《Analytical letters》2012,45(13-14):1349-1358
Abstract

1-Hydroxy-2-carboxyanthraquinone reacts with magnesium in ethanol-water mixtures to form a red complex having an absorption maximum at 490 nm in alkaline medium. A detailed study of the characteristics of this complex has been carried out and a spectrophotometric method for the determination of magnesium at the 0.4–4.0 μg ml?1 level is proposed. The method has been sensitized by employing first derivative spectrophotometry. By the use of the derivative approach magnesium can be determined between 0.08–0.40 μg ml?1. Statistical analysis of the results is also described.  相似文献   

19.
The selective and very sensitive fluorimetric determination of mebendazole and flubendazole is based on alkaline hydrolysis and adsorption on Whatman 42 filter paper. Limits of detection are 0.1 μg ml?1 and 0.5 μg ml?1, respectively, with linear response sponse up to 10 μg ml?1 and 50 μg mlt?1. The fluorescence produced is very stable (λem = 460 nm) and the method is applicable to anthelmintic pharmaceutical preparations.  相似文献   

20.
A method for the simultaneous flow injection spectrophotometric determination of calcium and magnesium with Arsenazo III based on the use of diode-array detector and merging zones is described. The method is applicable to the resolution of mixtures in which the chromogenic reagent has a high absorbance and its spectrum strongly overlaps those of its complexes. In resolving the mixtures, the excess reagent is considered as another component. Quantitation is based on the normal absorbance and first-derivative absorbance spectra. The method is applied to 0.2–1.5 μg ml?1 Ca and 0.1–1.0 μg ml?1 Mg. The analysis rate is 50 h?1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号