首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 640 毫秒
1.
自行研制的全盘自动化气相色谱仪在通用计算机的支持下,通过单纯形自动寻优,在色谱专家水平上建立了分析样品的最佳气相色谱分析方法。  相似文献   

2.
Fast gas chromatography/negative-ion chemical ionization mass spectrometric (GC/NICI-MS) assay combined with rapid and nonlaborious sample preparation is presented for the simultaneous determination of benzodiazepines and alpha-hydroxy metabolites, zaleplon and zopiclone in whole blood. The compounds were extracted from 100 microl of whole blood by simultaneous multitube, microscale liquid-liquid extraction (LLE) and derivatized by N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA), without the need for the time-consuming concentration stage. In the analytical separation, various parameters of fast GC/NICI-MS were applied, e.g. the use of hydrogen as a GC carrier gas, a high carrier gas velocity, a small film thickness of the analytical column, fast MS data acquisition, fast temperature ramping, and high initial and final temperatures of GC column. Sensitive identification, screening and quantitation of 18 compounds of interest were achieved in chromatographic separation in only 4.40 min. Accurate and reproducible results were obtained by using five different and carefully selected deuterated analogues on the basis of the chemical properties of the target analytes. Nevertheless, for alpha-OH-midazolam, and for bromazepam and flunitrazepam at low concentrations, the results can be considered only semiquantitative on the basis of the validation data. The extraction efficiencies ranged from 74.3 to 105.7% and the limits of quantitation (LOQ) from 1 to 100 ng ml(-1). Rapid sample preparation and fast chromatographic separation allowed cost-efficient, reliable and high sample-throughput analyses with a low amount of manual work. The method was fully validated and accredited according to EN ISO/IEC 17025 standards and is applicable for sensitive, reliable and quantitative determination of benzodiazepines, zaleplon and zopiclone, e.g. in clinical and forensic toxicology.  相似文献   

3.
Large-volume injection utilizing programmable temperature vaporizer in solvent vent mode is combined with fast capillary gas chromatography and mass spectrometric detection. Optimized injection and chromatographic conditions made possible manual injection of a 20-microL ethyl acetate extract containing 15 organochlorine pesticides and their separation on a short, 0.1-mm-i.d. column in less than 8 min.  相似文献   

4.
A comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones has been conducted. Nine different mixtures of bath salts were analyzed in this study. The three different chromatographic techniques were examined using a general set of controlled synthetic cathinones as well as a variety of other synthetic cathinones that exist as positional isomers. Overall 35 different synthetic cathinones were analyzed. A variety of column types and chromatographic modes were examined for developing each separation. For the ultra high performance supercritical fluid chromatography separations, analyses were performed using a series of Torus and Trefoil columns with either ammonium formate or ammonium hydroxide as additives, and methanol, ethanol or isopropanol organic solvents as modifiers. Ultra high performance liquid chromatographic separations were performed in both reversed phase and hydrophilic interaction chromatographic modes using SPP C18 and SPP HILIC columns. Gas chromatography separations were performed using an Elite‐5MS capillary column. The orthogonality of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography was examined using principal component analysis. For the best overall separation of synthetic cathinones, the use of ultra high performance supercritical fluid chromatography in combination with gas chromatography is recommended.  相似文献   

5.
快速气相色谱法分析石油饱和烃   总被引:6,自引:0,他引:6  
武杰  曹磊  李英明  端裕树 《色谱》2004,22(5):479-481
提出了一种快速分析原油和岩石抽提物中饱和烃组分的毛细管气相色谱(GC)方法。由于在该方法中采用了细内径毛细管柱,故饱和烃的GC分析周期由原来的80~90 min缩短至15 min,分析速度加快约5倍,大大提高了工作效率和仪器通量,使石油饱和烃得到了很好的分离分析。该方法符合中华人民共和国石油天然气行业标准SY/T5120-1997的要求。20万理论塔板数的细径柱的应用,可供石油中异构烷烃,尤其是甾烷、萜烷类的气相色谱/质谱(GC/MS)快速分析方法及芳烃的GC快速分析方法借鉴。  相似文献   

6.
A GC/FID methodology for determination of twenty-one free amino acids in quince fruit (pulp and peel) and jam is described. The sample preparation was simple, involving a SCX Solid-Phase Extraction (SPE) purification step and a fast derivatization with ethyl chloroformate for gas chromatographic analysis. The chromatographic separation was achieved using a CP-Sil 19 CB wcot fused-silica capillary column. Under the chosen conditions, with temperature and pressure programming, this capillary column was able to separate all the amino acids not only in a short time but also with good separation. The GC/FID procedure is rapid, sensitive, reproducible and accurate. The detection limit values for amino acids were low, between 0.004 and 0.115 microg/mL, and the method was precise. As a general rule, the recovery values were high. Due to its rapidity and low cost, this technique can be useful in the quality control of quince products.  相似文献   

7.
The detector is an integral and important part of any chromatographic system. The chromatographic peak profiles (i.e. peak separation) should, ideally, be unaffected by the detector--it should only provide the sensing capacity required at the end of a column separation process. The relatively new technique of comprehensive 2-D GC (GC x GC) extends the performance of GC manyfold, but comes at a price--existing GC systems may not be adequately designed with the requirements of GC x GC in mind. This is primarily the need for precise measurement of very fast peaks entering the detector (e.g. as fast as 50 ms basewidth in some instances). The capacity of the detector to closely track a rapidly changing chromatographic peak profile depends on a number of factors, such as design of flow paths and make-up gas introduction, type of detector response mechanism, and the chemistry of the response. These factors are discussed here as a means to appreciate the technical demands of detection in GC x GC. The MS detector will not be included in this review.  相似文献   

8.
A high resolution gas chromatographic method is described for the separation of rhesus monkey urinary metabolites of doxylamine with the use of on-column injection, a fused silica column (DB-1701), and nitrogen/phosphorus detection. An ancillary separation of doxylamine and six other antihistamines is also presented.  相似文献   

9.
The separation of coeluting congeners of Aroclor 1242, 1254, and 1260 on a DB-1 (low polarity) capillary gas chromatographic (GC) column is achieved when cuts of those peaks are transferred onto a smectic liquid crystalline column, which is commercially available. This procedure requires the use of a gas chromatograph equipped with two independent ovens for optimizing the temperature conditions of each column. Excellent base line separations are achieved on multicuts, up to six, of the same injection. This unique multidimensional/multimodal capillary GC system, in which the two separation modes of vapor pressure and molecule geometry are employed, is a powerful analytical technique for the separation of complex organic mixtures.  相似文献   

10.
Recently developed MOF surface-coating techniques, the controlled SBU approach (CSA) for the generation of MOF-5, and the use of self-assembled monolayers have been combined to generate a wall-bonded, crosslinked stationary phase for gas chromatographic capillary columns displaying excellent performance in the separation of natural gas components. The chromatographic performance of this new type of column has been compared to the state-of-the-art solution for this separation problem, namely a coated silica column of the porous layer open tubular (PLOT) type. Chromatographic parameters such as separation, resolution, and tailing factors, as well as plate numbers and heights in the case of isothermal operation, have been determined. Kinetic and thermodynamic parameters characterizing the analyte-stationary phase interaction have been determined for various C1-C4 analytes.  相似文献   

11.
气相色谱专家系统中柱系统的推荐   总被引:2,自引:0,他引:2  
许国旺  张玉奎 《分析化学》1993,21(2):143-147
本文给出气相色谱专家系统中柱系统推荐软件的总体结构和设计及一个运用所研制的软件进行咨询的例子。用户只要回答与样品中组分结构有关的几个关键问题,软件即可对样品可否采用气相色谱法进行判断和对气相色谱柱系统进行推荐。从初步使用和验证来看,本系统是成功的。  相似文献   

12.
为了满足当今教学的信息化发展趋势,本研究基于随机扩散理论建立了气相色谱仿真模型并开发了相关的计算模拟软件Stochastic Diffusion-Chroma。以混合组分分别在气相色谱填充柱和毛细管柱中的扩散分离模拟为例,探究了随机扩散理论模型在色谱理论教学和实验教学方面的应用。基于随机扩散理论的仿真教学改变了传统的教学模式,将学生较难理解的抽象色谱动力学基本理论转变为动态的具体形象,激发了学生的学习兴趣,提高教学质量。  相似文献   

13.
A procedure was developed for modelling the gas chromatographic separation on a system of columns coupled in series. This procedure can be used for computer based optimization of lengths and order of serially coupled columns at isothermal conditions. The sample component retention factors and column resistances needed for the model can easily be measured on each individual column. The proposed procedure was verified by analyzing a 52 component hydrocarbon mixture on three columns of different polarity coupled in series by various column orders. Good agreement between experimental and calculated retention data was found. The procedure is also well suited for optimization of the chromatographic selectivity by coupling columns with different selectivity in series.Dedicated to Professor Dr. h.c. mult. J.F.K. Huber on the occasion of his 70th birthday  相似文献   

14.
High-speed gas chromatographic (GC) separation of residual solvents in pharmaceutical preparations, using a flow-modulation technique, is described. These volatile compounds are separated on a series-coupled (tandem) column ensemble consisting of a polyethylene glycol column and a trifluoropropylmethyl/dimethylpolysiloxane column. This column ensemble is operated in stop-flow mode to enhance, or "tune", the separation. A valve between the junction point of the tandem column ensemble and a source of carrier gas at a pressure above the GC inlet pressure is opened for intervals of 2-8 s. This stops or slightly reverses the flow of carrier gas in the first column. Stop-flow pulses are used to increase the separation of target analytes that overlap in the total ensemble chromatogram, compared to non-stop-flow, or conventional, operation. All 36 target compounds, based on ICH Classes I and II residual solvent lists, are resolved in 12 min using the stop-flow technique and a single chromatographic analysis.  相似文献   

15.
Summary The possibility of constructing a mathematical model of n-alkanes retention upon their separation by gas solid chromatography with temperature programming has been studied. The functional dependence between the number of the carbon atoms in n-alkane molecules, their retention in isothermal conditions and temperature of chromatographic column was used for constructing this mathematical model. It showed necessary to take into account the variance in the process temperature programming of both the carrier gas volume velocity and the column inlet pressure to obtain the adequate mathematical model of the chromatographic retention. With the use of the specific retention parameters of substances i.e. relative to the surface or the mass of sorbents the proposed model can be used not only for Silochrom C-80 but for the whole class of macroporous silica sorbents.  相似文献   

16.
Rapid drug metabolite profiling can be achieved using fast chromatographic separation and fast mass spectrometric scanning without compromising the separation efficiency. Fast chromatographic separations of drug and its metabolites can be achieved by eluting from a short narrow-bore guard cartridge column (20 x 2 mm I.D., 3 microns BDS Hypersil C8) at flow-rate of 1.0 ml/min and with a gradient volume greater than 90 column volumes. The need for chromatographic separation is important for automated data dependent multiple-stage mass spectrometry (MSn) experimentation. The total analysis time of 8 min permits profiling of metabolites in a 96-well plate in 13 h. The narrow chromatographic peaks resulting from the high flow-rate require the use of a mass spectrometer capable of fast scan speed due to the need to perform multiple MS experiments within the same chromatographic analysis. A method has been developed for screening potentially biologically active in vitro microsomal metabolites by affinity binding with a receptor. After separation by centrifugal ultrafiltration, the bound ligands are released and characterized by LC-MS. In vitro microsomal metabolites of tamoxifen, raloxifene and adatanserin were screened for potential biological activity using this method. The in vitro metabolites of tamoxifen captured by the receptor include N-demethyltamoxifen and three species of hydroxytamoxifen; these data are consistent with those from a conventional binding study and bioassay. In addition, both hydroxyraloxifene and dihydroxyraloxifene are also recognized by the receptor. The specificity of the molecular recognition process is illustrated by the absence of binding with control microsomal incubate and with adatanserin and its metabolites. Therefore, active metabolites can be rapidly profiled by fast LC, automated MSn, and receptor binding. This information can be obtained quickly and can add value to the drug discovery process.  相似文献   

17.
This paper reports the use of DryLab, a computer simulation software package, to assist in the development and optimization of a reversed-phase high-performance liquid chromatographic (HPLC) method for the separation of a model drug candidate and its degradation products. Prior to the optimization process, columns with various bonded phases are evaluated for their chromatographic performance using the sample of interest. Simultaneous optimization of two separation variables and the use of resolution maps to predict the optimal conditions are illustrated. Options to optimize column conditions (column length and flow-rate) to further reduce run time are briefly discussed. The accuracy of DryLab-predicted retention times and resolution is compared with experimental values. The DryLab software used in this study provided satisfactory predictions for the selected model, with average errors of less than 3.5 and 11.8% for retention time and resolution, respectively.  相似文献   

18.
王东新 《分析测试学报》2005,24(5):39-41,45
溶胶-凝胶色谱柱有很强的热稳定性,在升温过程中,固定相的流失很低,且有很长的柱寿命与之相比,静态法涂渍及用自由基引发交联反应使固定相固载化的传统色谱柱在柱温远低于溶胶-凝胶柱使川温度的条件下,固定相明显流失且柱寿命短。  相似文献   

19.
Summary High resolution gas chromatography requires the highest performance characteristics of gas chromatographic systems in terms of sampling and sample handling in strumentation, columns, and data handling. This paoper describes high precision computer measurements for characterizing capillary column efficiencies which are within 75% of the theoretical limit of capillary GC. Particular emphasis is given to detailed peak shape analysis, measurement accuracy and reproducibility, and system stability. Using known instrument performance parameters, it is then possible to characterize column performance with high accuracy in a meaningful manner. It is proposed that wall-coated tubular columns be characterized in terms of their chromatographic performance by the following parameters: Trennzahl (separation number), number of theoretical plates/meter, program temperature beseline stability, acid-base ratio, and the coefficient of skewness for 1-octanol. Statistical moments (m2) and hybrid moments are used to describe capillary column chromatographic performance because they may be related to basic physico-chemical column processes. These measurements are very sensitive parameters for characterizing GC columns. Using an online computer-based data system, the limits of capillary GC are shown to be limited by the sampling and injection steps.  相似文献   

20.
A surfactant-bound monolithic stationary phase based on the co-polymerization of 11-acrylamino-undecanoic acid (AAUA) is designed for capillary high performance liquid chromatography (HPLC). Using D-optimal design, the effect of the polymerization mixture (concentrations of monomer, crosslinker and porogens) on the chromatographic performance (resolution and analysis time) of the AAUA–EDMA monolithic column was evaluated. The polymerization mixture was optimized using three proteins as model test solutes. The D-optimal design indicates a strong dependence of chromatographic parameters on the concentration of porogens (1,4-butanediol and water) in the polymerization mixture. Optimized solutions for fast separation and high resolution separation, respectively, were obtained using the proposed multivariate optimization. Differences less than 6.8% between the predicted and the experimental values in terms of resolution and retention time indeed confirmed that the proposed approach is practical. Using the optimized column, fast separation of proteins could be obtained in 2.5 min, and a tryptic digest of myoglobin was successfully separated on the high resolution column. The physical properties (i.e., morphology, porosity and permeability) of the optimized monolithic column were thoroughly investigated. It appears that this surfactant-bound monolith may have a great potential as a new generation of capillary HPLC stationary phase.  相似文献   