共查询到20条相似文献,搜索用时 15 毫秒
1.
A carbon paste electrode chemically modified with anion-exchangers is used for the voltammetric determination of gold(III). Tetrachloro- or tetrabromo-aurate(III) is preconcentrated on the electrode surface, modified with Amberlite LA2, and the electrode is transferred to an electrochemical cell for voltammetric measurements by cathodic stripping. The response depends on the concentration of gold in the bulk solution, preconcentration time, and other parameters. Detection limits are 100–300 μg l?1 depending on the conditions. Many elements forming stable halo complex anions interfere. 相似文献
2.
Voltammetric determination of trace amounts of mercury with a carbon paste electrode modified with an anion-exchanger 总被引:2,自引:0,他引:2
X. Cai K. Kalcher W. Diewald C. Neuhold R. J. Magee 《Fresenius' Journal of Analytical Chemistry》1993,345(1):25-31
Summary A carbon paste electrode modified with a liquid anion exchanger (Amberlite LA2) was used for the voltammetric determination of mercury(II). Mercury is preconcentrated, as tetrachloromercurate(II), onto the surface of the modified electrode only by the ion-exchange effect of the modifier without application of potential. After exchange of the medium the accumulated amount of mercury(II) is determined by differential pulse anodic stripping voltammetry in a blank electrolyte solution. The response depends on the concentration of mercury in the bulk solution, preconcentration time, and other parameters. The detection limit was 1 g Hg(II)/l when a suitable time for preconcentration was chosen. Preconcentration for 5 min yields a linear calibration graph for concentrations up to 1000 g Hg(II)/l. The effect of other ions on the determination of mercury and the applicability of the method to the analysis of phenylmercury compounds in pharmaceutical preparations were investigated. 相似文献
3.
G. Kölbl K. Kalcher A. Voulgaropoulos 《Fresenius' Journal of Analytical Chemistry》1992,342(1-2):83-86
Summary The voltammetric behaviour of gold on carbon paste electrodes chemically modified with Rhodamine B by means of electrostatical binding was studied. The dye was attached to the electrode material with hexane sulphonic acid. Gold was determined by differential pulse voltammetry after preconcentration under open circuit conditions and medium exchange. Thus, 5 g Au/l could be analyzed. Linearities between signal response and concentration were found for concentrations up to 10 mg/l when measuring in the differential pulse mode. Parameters like composition of the paste and of the analyte solution as well as interferences with other ions were investigated. 相似文献
4.
Willian Toito Suarez Luiz H. Marcolino Jr. Orlando Fatibello-Filho 《Microchemical Journal》2006,82(2):163-167
The preparation and electrochemical characterization of a carbon paste electrode modified with copper(II) hexacyanoferrate(III) (CuHCF) as well as its behavior as electrocatalyst toward the oxidation of N-acetylcysteine were investigated. The electrochemical behavior of the modified electrode and the electrooxidation of N-acetylcysteine were explored using sweep linear voltammetry. The best voltammetric response was observed for a paste composition of 20% (w/w) copper(II) hexacyanoferrate(III) complex, acetate buffer solution at pH of 6.0 as the electrolyte and scan rate of 10 mV s− 1. A linear voltammetric response for N-acetylcysteine was obtained in the concentration range from 1.2 × 10− 4 to 8.3 × 10− 4 mol L− 1, with a detection limit of 6.3 × 10− 5 mol L− 1. The proposed electrode is useful for the quality control and routine analysis of N-acetylcysteine in pharmaceutical formulations. 相似文献
5.
Voltammetric determination of traces of cobalt(II) with a chemically modified carbon paste electrode
Summary A new preconcentration and voltammetric determination method for cobalt(II) in aqueous solution with a chemically modified electrode is proposed. The accumulation behaviour and voltammetry of cobalt(II) has been investigated with a carbon paste electrode modified with cationexchanger and 1,10-phenanthroline. The electrochemical response is characterized with respect to carbon paste composition, pH, preconcentration time, cobalt(II) concentration and other variables. For a 3-min preconcentration time, the electrode gives good linearity for 1×10–7 to 4×10–6 mol/l Co(II), a detection limit of 8×10–8 mol/l. The response can be reproduced with a 4.0% relative standard deviation. The method is fairly free from many coexisting ions interferences. A rapid and convenient renewal procedure allows the use of a single electrode in multiple analytical determinations over several days. Satisfactory results are obtained for the determination of cobalt in a variety of certified standard reference materials. 相似文献
6.
A method for the determination of trace amounts of silver with a chemically modified carbon paste electrode is described. The modified electrode is prepared by simply mixing a chelating resin (a polythioether backbone and dioxymonosulphur polyethylene polyimines in the side-chain polymer) with graphite powder and Nujol oil. By immersing the electrode in a silver sample solution (pH = 6.5–7.5), silver can be adsorbed on the electrode surface and then determined by voltammetry in a separate blank solution. The response depends on the concentration of silver and the preconcentration time. For a preconcentration time of 5 min, the detection limit is about 3 × 10?10 M and the linear range is from 5 × 10?10 to 1 × 10?7 M with a relative standard deviation of 4%. Many common metal ions have no or little effect on the determination of silver. The recommended procedure was applied to the determination of trace amounts of silver in waste water. 相似文献
7.
The clay mineral montmorillonite has been tested as modifier for the carbon paste electrode with a novel electrode modification technique. The differential pulse voltammetric determination of copper(II) by means of this modified carbon paste electrode has been studied. A detection limit of 4x10(-8) mol/l has been achieved after 10 min preconcentration under open circuit conditions with subsequent anodic stripping voltammetry. The calibration curve for Cu(II) is linear in the range of 4x10(-8)-8x10(-7) mol/l. Pb interferes in a 10-fold molar and Cd and Hg in a 100-fold molar excess. The interference by humic ligands is significant. 相似文献
8.
The clay mineral montmorillonite has been tested as modifier for the carbon paste electrode with a novel electrode modification technique. The differential pulse voltammetric determination of copper(II) by means of this modified carbon paste electrode has been studied. A detection limit of 4×10-8 mol/l has been achieved after 10 min preconcentration under open circuit conditions with subsequent anodic stripping voltammetry. The calibration curve for Cu(II) is linear in the range of 4×10-8–8×10-7 mol/l. Pb interferes in a 10-fold molar and Cd and Hg in a 100-fold molar excess. The interference by humic ligands is significant. 相似文献
9.
The electroanalytical determination of isoprenaline in pharmaceutical preparations of a homemade carbon paste electrode modified with copper(II) hexacyanoferrate(III) (CuHCF) was studied by cyclic voltammetry. Several parameters were studied for the optimization of the sensor such as electrode composition, electrolytic solution, pH effect, potential scan rate and interferences in potential. The optimum conditions were found in an electrode composition (in mass) of 15% CuHCF, 60% graphite and 25% mineral oil in 0.5 mol l−1 acetate buffer solution at pH 6.0. The analytical curve for isoprenaline was linear in the concentration range from 1.96×10−4 to 1.07×10−3 mol l−1 with a detection limit of 8.0×10−5 mol l−1. The relative standard deviation was 1.2% for 1.96×10−4 mol l−1 isoprenaline solution (n=5). The procedure was successfully applied to the determination of isoprenaline in pharmaceutical preparations; the CuHCF modified carbon paste electrode gave comparable results to those results obtained using a UV spectrophotometric method. 相似文献
10.
11.
Xiaohua Cai Kurt Kalcher Josef Lintschinger Christian Neuhold 《Mikrochimica acta》1993,112(1-4):135-146
A carbon paste electrode modified with 2-mercapto-4(3H)-quinazolinone was used for the voltammetric determination of mercury(II). Mercury was preconcentrated onto the surface of the modified electrode only by the complexing effect of the modifier without application of potential (i.e. in open-circuit conditions). After exchange of the medium, the accumulated amount of mercury(II) was determined by differential pulse anodic stripping voltammetry. The response depended on the concentration of mercury in the bulk solution, preconcentration time, and other parameters. The detection limit was 0.1 g 1–1 Hg(II) for a preconcentration time of 15 min. Preconcentration for suitable times yielded a linear calibration graph from 0.5 to 6000 g 1–1 Hg(II). For multiple determinations (5 runs), the relative standard deviation was 5% for a concentration of 100 g 1–1 Hg(II). The proposed procedure was used to determine trace mercury in plant and sewage sludge samples with good results.On leave from Hainan University, Hainan Peoples Republic of China 相似文献
12.
《Fresenius' Journal of Analytical Chemistry》1992,344(1-2):34-38
Summary The anodic voltammetric behaviour of pentachlorophenol at a silica gel-modified carbon paste electrode in aqueous solution
is reported. Adsorption of the fungicide onto the electrode under open-circuit conditions is followed by application of either
differential or square wave voltammetry. The results obtained by differential pulse voltammetry at pH 2.9, with a modifier
concentration of 10% and accumulation times of 120 and 300 s, allowed the development of a method to determine pentachlorophenol
in the ranges of 1.0×10−6–1.0×10−5 and 1.0×10−7–1.0×10−6 mol l−1. The relative standard deviation is 2.6% for a concentration of 2.0×10−7 mol l−1, with a detection limit of 1.8×10−8 mol l−1 (5 ppb). The effect of other chlorophenols was studied. The results obtained by square wave voltammetry showed a behaviour
typical of an irreversible electron transfer. Amplitude, step height and frequency were optimised, taking into account the
resolution of the voltammetric response. No improvement in sensitivity was obtained with respect to DPV. Good results were
obtained by applying the proposed differential-pulse voltammetric method to the determination of pentachlorophenol in a commercial
fungicide. 相似文献
13.
The voltammetric detection of phosphoproteins was developed using a gallium(III) acetylacetonate-modified carbon paste electrode. Because phosphate groups of the protein interacted with the gallium(III) ion, the protein was accumulated on the electrode surface. A hexaammine ruthenium(III) ion, which combined with the functional groups, was used to monitor the interaction. When phosvitin and hexaammine ruthenium(III) ions were incubated in 0.1 M acetate buffer (pH 3.2), a reduction peak of hexaammine ruthenium(III) ion at the electrode decreased as the concentration of the protein increased. In contrast, an increase in the peak current was observed with a plain carbon paste electrode. These results were caused by a competitive reaction of the phosphate groups with the hexaammine ruthenium(III) and gallium(III) ions. In the presence of α-, β- and κ-caseins, the electrode response decreased due to the order of the numbers of phosphate groups. This method could be applied to the sensing of phosphoproteins at the 10(-10) M level. 相似文献
14.
A new strategy for the preparation of a DNA-modified carbon paste electrode is developed. It is found that the anodic response of mifepristone is greatly enhanced at the dsDNA-modified carbon paste electrode comparing with that obtained at the bare electrode, while the response at a ssDNA-modified electrode is similar to bare electrode. So the dsDNA-modified electrode is employed as a sensitive biosensor for the detection of mifepristone. A linear dependence of the peak currents on the concentration is observed in the range 2.0 x 10(-7) approximately 2.0 x 10(6) mol/L, with a detection limit of 1.0 x 10(-7) mol/L. The relative standard deviation is 4.3% for six successive determinations of 1.0 x 10(6) mol/L mifepristone. The determination of mifepristone tablets is carried out and satisfactory results are obtained. 相似文献
15.
A glassy carbon electrode (GCE) modified with internal-electrolysis deposited gold nanoparticles (AuNPsied) was applied to sensitively and selectively detect As(III) by anodic stripping linear sweep voltammetry (ASLSV). The AuNPsied/GCE was prepared based on the redox replacement reaction between a supporting-electrolyte-free aqueous HAuCl4 and a copper sheet in saturated KCl separated by a salt bridge. Under optimum conditions (0.5 M aqueous H2SO4, 300-s preconcentration at − 0.4 V), the ASLSV peak current for the As(0)–As(III) oxidation responded linearly to As(III) concentration from 0.02 to 3 μM with a limit of detection (LOD) of 0.9 nM (0.07 μg L− 1) (S/N = 3), while that for the As(III)–As(V) oxidation was linear with As(III) concentration from 0.02 to 1 μM with a LOD of 4 nM (0.3 μg L− 1) (S/N = 3). An appropriate high-scan-rate for ASLSV can enhance both the sensitivity and signal-to-noise ratio. This method was applied for analyses of As(III) in real water samples. 相似文献
16.
The preconcentration and voltammetric behavior of BiIII on a sodium humate modified carbon paste electrode was studied by means of cyclic voltammetry (CV) and differential pulse stripping voltammetry (DPSV). The proposed measurement involves an initial nonelectrolytic preconcentration step in which BiIII is complexed by the surface modifier in a solution of 0.05 M KNO3-0.0106 M HNO3 (pH 2.0) and a subsequent electrochemical scan step in which the preconcentrated BiIII was reduced and then oxidized promptly in supporting electrolyte of 0.5 M HNO3. The resulting DPSV anodic current was proportional to the concentration of BiIII ion over the range of 4.78 × 10−8–1.44 × 10−5 M. The detection limit was 4.78 × 10−8 M. The proposed method was used to determine bismuth in various samples. Various factors affecting the electrode behavior were also investigated at the same time. 相似文献
17.
In the present work TiO2 nanotubes (TNT) have been synthesized by alkaline hydrothermal transformation. Then they have been doped with Gd element. Characterizations of doped and undoped TNT have been done with TEM and SEM. The chemical composition was analyzed by EDX, Raman and FTIR spectroscopy. The crystal structure was characterized by XRD. Carbon paste electrode has been fabricated and mixed with Gd doped and undoped TNT to form a nanocomposite working electrode. Comparison of bare carbon paste electrode and Gd doped and undoped TNT carbon paste electrode for 1.0 ×10−3 M K4 [Fe(CN)6] voltammetric analysis; it was observed that Gd doped TNT modified electrode has advantage of high sensitivity. Gd doped TNT modified electrode has been used as working electrode for itopride assay in a pharmaceutical formulation. Cyclic voltammetry analysis showed high correlation coefficient of 0.9973 for itopride (0.04–0.2 mg/mL) with a limit of detection (LOD) and limit of quantitation values (LOQ) of 2.9 and 23.0 μg.mL−1 respectively. 相似文献
18.
19.
Azithromycin (AZ) is the first member of a class of macrolide azalides antibiotics called azolides. A simple and selective square-wave voltammetric (SWV) method has been developed for the determination of azithromycin in pure form, in pharmaceutical preparation and in biological samples. Determination of azithromycin was accomplished with hand-make carbon paste electrode (CPE) in oxidative screen mode. The counter and reference electrodes were a Pt wire and a Ag/AgCl, respectively. Various parameters that can influence the peak signal (effect of buffer, ionic strength, accumulation time, pH and the composition of the paste) have been scrutinized. The best results were obtained in acetonitrile—aqueous 1 M sodium acetate-acetic acid buffer (pH 4.6) containing 0.1 M KCl (1:9; v/v) using a 15% paraffin oil CPE. The limits of detection and quantification of the pure drug are 0.463 and 1.544 ppb (with the correlation coefficient, r=0.9785and the standard deviation, S.D.=0.1 (n=5), for the accumulation time of 60 s), respectively. The method was successfully applied to the determination of the drug in urine and two forms of pharmaceutical formulations. Recoveries were 99.2—100.5% with S.D.=0.1—and 0.8% (n=5). 相似文献
20.
Y. BallesterosM.J. Gonzalez de la Huebra M.C. QuintanaP. Hernandez L. Hernandez 《Microchemical Journal》2003,74(2):193-202
The electrochemical behaviour of kinetin (6-furfurylaminopurine) on a carbon paste modified with OV-17 silicone electrode, is studied. The determination of kinetin is possible working in square wave voltammetric techniques, reaching limits of determination of 38.7 ng ml−1. The proposed method was successfully applied to determine the cytokinin in extracts of apples (previously spiked with kinetin) and the obtained results were in accordance with the results obtained with HPLC-UV. 相似文献