首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
In the present study, the determination of mineral and trace elements (Al, B, Ca, Cu, Fe, K, Mg, Mn, Na, P and Zn) from pine needles using three sample pre-treatment methods followed by inductively coupled plasma optical emission spectrometry, was examined. Sample pre-treatment methods tested were microwave digestion, ultrasound-assisted digestion and dry ashing. The new ultrasound-assisted digestion method was optimised by the analysis of the standard reference material (SRM) 1575a (pine needles) sample. The speed of dry ashing method was significantly increased by ultrasound dissolution after ashing. All the ICP-OES measurements were performed in robust plasma conditions which were tested by measuring the Mg II 280.270 nm/Mg I 285.213 nm line intensity ratios. The microwave digestion resulted generally in slightly higher element concentrations than ultrasound-assisted digestion. B, Cu and Na resulted in such low concentrations that they could not be accurately determined by using the microwave digestion method. The t-tests found no significant differences between the certified and the determined element concentrations of the SRM 1575a using the dry ashing method followed with ultrasound dissolution.  相似文献   

2.
Two microwave heated digestion techniques have been tested with a view to the evaluation of the effectiveness of wet decomposition procedures: a high-pressure/temperature focused microwave heated and an on-line microwave heated system. The efficiency of decomposition was studied using a number of biological reference materials as well as urine and sewage plant effluent. Oxidation reagents included mixtures of nitric acid, nitric acid/hydrogen peroxide and peroxodisulphate (Oxisolv). The residual carbon content of the digestate was determined coulometrically. Pressurised decomposition of a TFM-Teflon vessel is the most effective procedure (organic material is totally oxidised with nitric acid in a single-step procedure), whereas urine and sewage plant effluent are incompletely decomposed with on-line microwave heated digestion.  相似文献   

3.
Summary In order to investigate the precision and accuracy obtainable with instrumental neutron activation analysis (INAA) and inductively coupled plasma atomic emission spectrometry (ICP-AES), five different biological reference materials were analyzed. Four of them originated from the US National Institute of Standards and Technology (NIST) (Bovine Liver (SRM 1577; 1577/a; 185/A), Orchard Leaves (SRM 1571)) and one of them came from the International Atomic Energy Agency (IAEA) (Animal muscle (H-4)). The decomposition efficiency of microwave acid digestion was examined in comparison to digestions carried out in a Parrbomb. Five to ten subsamples of each material were subjected to the two digestion procedures and the solutions were analyzed by ICP-AES. The dried samples were analyzed by INAA. Up to 16 elements (Al, B, Ca, Co, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, P, Pb, S, Zn) were determined in various materials.  相似文献   

4.
Two microwave digestion systems (open-focused and closed-pressurized) were tested for the mineralization of human brain and bovine liver (NIST SRM 1577a) as dissolution steps prior to the determination of 16 trace elements (Bi, Cd, Co, Cs, Cu, Fe, Hg, Mn, Mo, Pb, Rb, Sb, Sn, Sr, Tl, and Zn) by inductively coupled plasma mass spectrometry (ICP-MS). Digestion parameters (mass of sample, digestion mixture, and power/time steps) were optimized using temperature and pressure sensors. Digestions with the open-focused microwave system require larger volumes of conc. HNO(3) and 30% H(2)O(2) than digestions with the closed-pressurized system. Both systems produce correct results for the bovine liver samples. The concentrations obtained for the digests of the open-focused system tend to be less precise than the concentrations from the "closed-pressurized" digests. Because the "open-focused" digests must be diluted to 50 mL to bring the acid concentration to 0.7-2.0 mol/L required by the ICP-MS (closed-pressurized digests need to be diluted to only 20 mL), the detection limits for the system with the open-focused digestion are higher than for the system with the closed-pressurized digestor. The open-focused digestor cannot handle more than 150 mg brain tissue, whereas the closed-pressurized system can mineralize 470 mg. The latter method gave better results with brain tissue than the open-focused system. The preparation of brain tissue as reference material for the determination of trace elements in brain samples is described.  相似文献   

5.
A microwave-assisted double insert multimode vapour-phase digestion method was developed for the digestion of organic samples. The experimental set-up was based on a third generation-type teflon microwave vessel, equipped with an automatic pressure regulating type vessel cover. A borosilicate glass holder insert, containing a smaller quartz sample insert, was fitted inside the vessel. Sulphuric acid was added to the holder insert as a microwave absorbing and temperature transferring liquid, which transferred heat to the sample insert (into which the sample was weighed) and charred the sample material. Oxidation of the sample material was carried out simultaneously with charring using nitric acid vapour, which was generated by the 1:1 (v/v) sulphuric acid-nitric acid mixture located in the bottom of the microwave vessel. This set-up generated high digestion efficiency, without any of the interferences normally associated with direct sulphuric acid usage. The method was used for determining the concentrations of Cd, Cr, Cu, Mn, Mo, Zn and Fe in certified organic reference materials using ICP-OES instrumentation. The certified organic reference materials were NRCC DOLT-2 dogfish liver, NIST-SRM 1577b bovine liver and IRMM VDA cadmium in polyethylene No. 001 and No. 004. The results were in good agreement with the certified values, forepart from Cd. For Cd the results were lower than the certified values due to volatilization losses. Sample materials that could not be digested by an earlier procedure were completely digested during a single-step, 30 min digestion. The tested sample materials included certified reference materials, 3-nitrobenzoic acid (3-NBA) and pike (Esox lucius) muscle. The residual carbon concentrations in the digestion solutions were below the detection limit of the TOC instrument. This type of digestion method is described here for the first time in the literature.  相似文献   

6.
本文提出硅石消解新技术--微波消解法.于聚氯乙烯消解罐中加硝酸、氢氟酸、高氯酸,程序加压升温分解硅石.微波消解法与冰浴法、加热消解法相比,可避免待测元素在分解过程带来的损失,且分解完全,酸用量少,操作简单、可靠.硅石经微波消解后采用火焰原子吸收光谱法检测铁、锰、镁、钙,铁、锰、镁、钙的回收率分别为97.3%~99.0%、104.4%~106.5%、95.7%~98.0%、103.1%~106.6%,与国家标准方法分析结果比较,相对误差均小于5%.  相似文献   

7.
The trace metal (Cd, Cu, Pb, Zn, Fe) contents of certified reference sediments BCSS-1, MESS-1, SRM 1645 river sediment and SRM 1646 estuarine sediment) were determined by nitric acid digestion at 140°C without silicate lattice dissolution. All the metals studied except iron were completely recovered by this digestion method. About 20% of the iron was not recovered under the given conditions. The trace metal contents in SRM 1645 were also examined by using the hydroxylammonium chloride/acetic acid leaching procedure.  相似文献   

8.
A microwave heated, vapor-phase nitric acid-hydrogen peroxide digestion method for pulverized, biological sample materials was developed. Sample masses up to 200 mg were digested using calibrated quartz inserts inside first generation type, low-pressure, Teflon-PFA microwave vessels. In the first step, samples were digested in the vapor-phase for 80 min using a progressive heating pattern. Three mL of 70% nitric acid and 0.5 mL of 30% hydrogen peroxide were used as digestion reagents. In the second step, the small residue left after first step digestion was dissolved in 1.4% nitric acid or additionally with 0.5% hydrofluoric acid by heating for 15 min. The digestion method was optimized using pike (Esox lucius) muscle as a test material. The method was further optimized using three certified reference materials. Ca, Cu, Fe, Mg and ¶Zn were determined from NIST-SRM 1577a bovine liver by ICP-AES. Cr and Ni were determined from NIST-SRM 8433 corn bran and NRCC DOLT-2 dogfish liver by GFAAS. For all elements the values obtained were close or within certified limits. Spike recoveries were between 96 to 107%. Digestion efficiency ranged from 91 to 99%.  相似文献   

9.
Summary Inductively coupled plasma atomic emission spectrometry (ICPAES) is applied to the determination of elements in paints and paint scrapings to evaluate potential occupational and environmental exposure to metals in paints. A microwave assisted digestion procedure of these materials using nitric and hydrofluoric acid mixtures under controlled pressure has been developed. The accuracy and repeatability of the recommended procedure for lead are documented and evaluated by analysing NIST SRM 1579 Powdered Lead Based Paint. Neutron activation analysis was applied as a reference method for other elements. A variety of industrial and domestic paints of different chemical composition were analysed. The advantages and limitations of microwave digestion of paints are discussed.  相似文献   

10.
NIST standard reference material SRM 2783 was employed to validate a high temperature, high pressure, two-stage microwave assisted acid digestion procedure using HNO3, HF and H3BO3 developed for the analysis of trace elements (including rare earths) in atmospheric fine particulate matter (PM2.5) prior to inductively coupled plasma mass spectrometry (ICP-MS). This method quantitatively solubilized Na, Mg, Al, K, Ti, V, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sb, Cd, Cs, Ba, Pb, Th, U and several rare earth elements (REEs) (La, Ce, Pr, Nd, Gd, Dy, Er, Sm and Eu) from SRM 1648 and SRM 2783. A small amount of HF in the first stage was required to dissolve silicates necessitating the corresponding addition of H3BO3 in second stage to dissolve fluoride precipitates of Mg, La, Ce and Th. The optimized microwave dissolution—ICP-MS method detected Na, Mg, Al, K, Ti, V, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Cd, Mo, Sb, Cs, Ba, La, Ce, Pr, Nd, Sm, Gd, Pb, Th and U at trace to ultra-trace levels in ambient airborne fine particles from three sites in North Carolina. La to light lanthanide signature ratios suggested that soil and motor vehicles are the dominant REE sources in SRM 2783 and PM2.5 samples collected during this study.  相似文献   

11.
The use of thek 0-standardization method in instrumental neutron activation analysis gives good accuracy and precision. The analysis time can be reduced drastically by employing software for thek 0-standardization calculations. In this work samples were irradiated in a TRIGA reactor and the gamma spectrum was analysed by Sampo 90 and thek 0-standardization by the KAYZERO/SOLCOI code (DSM Research). The efficiency measurement and the peak to total ratio at the reference and other geometries were measured and tested for their accuracy by analysing some reference materials. Reference materials such as SRM 1572 (Citrus leaves), SRM 1573 (Tomato leaves), SRM 1575 (Pine needles), IAEA Soil-7 (Soil) and SRM 1646 (Estuarine sediment) were analysed for the major, minor and trace element contents. The results were in good agreement with the certified or literature values. The recently released IAEA 140 (Sea plant homogenates) was also analysed for 28 elements.  相似文献   

12.
A closed microwave digestion method followed by inductively coupled plasma spectrometric (ICP-MS) analysis was evaluated for the determination of trace impurities in photoresist. To optimize the digestion procedure, several digestion parameters such as acid, heating temperature and heating time were evaluated. Besides, the digestion efficiency of used photoresist material and the recovery of analyte elements obtained by the use of gravimetric method and ICP-MS measurement, individually, were also compared to clarify the completeness of digestion. According to our experiments, the gravimetric method was found to be not so relevant to the completeness of digestion, because the remaining sample matrix could cause suppression effect in the subsequent ICP-MS measurement. In view of minimizing blank value and working time, a simple single-step heating program was proposed to mineralize 0.25 ml of photoresist material with 5 ml of nitric acid at 180 °C for 10 min. Based on the comparative study of the analytical results obtained by instrumental neutron activation analysis (INAA) and proposed method, the reliability of proposed method for the determination of trace metallic impurities in photoresist material has been confirmed.  相似文献   

13.
微波辅助湿法消解植物样品的研究   总被引:14,自引:0,他引:14  
王大宁  张寒琦 《分析化学》1990,18(5):482-484
  相似文献   

14.
Three digestion procedures have been tested on lichen samples for application in the determination of major, minor and trace elements (Al, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, V and Zn) in lichen samples collected in Aegean Region of Turkey by inductively coupled plasma atomic emission spectrometer (ICP-AES). The acid mixture of concentrated HNO3, H2O2 and HF were used. The instrument was optimized using lichen matrix considering RF power, nebulizer pressure, auxiliary flow rate and pump rate. The accuracy of the overall analyses was first estimated by analysis of two certified reference materials. Good agreement between measured and reference values were found for almost all elements. As the second way of determining the accuracy, results obtained from independent analytical techniques (ICP-AES and instrumental neutron activation analysis (INAA)) were compared for all elements by analyzing real samples. Correlation coefficients of two techniques for the elements ranged between 0.70 (Mg) and 0.96 (Fe). Among the three digestion systems, namely microwave, open vessel and acid bomb, microwave digestion system gave the best recovery results. The method detection limit (MDL) was computed using reagent blanks of microwave digestion system since it provides cleaner sample preparation. Detection limit is adequate for all elements to determine the elements in lichen samples. The precision was assessed from the replicate analyses of reagent blanks of microwave digestion system and was found to be less than 1.5% relative standard deviation (R.S.D.).  相似文献   

15.
The lowest possible sample weight for performing multielemental trace element analysis on environmental and biological samples by ICP-MS has been investigated. The certified reference materials Bovine Liver NIST SRM 1577b, Human Hair NCS DC 73347 and Oriental Tobacco Leaves CTA-OTL-1 were applied at sample weights (1, 5, 20 and 50 mg aliquots, n = 10) which were significantly lower than those recommended with most recoveries in the range of 95–110%. Samples were digested in a mixture of nitric acid, hydrogen peroxide and hydrogen fluoride by closed-vessel microwave digestion. Multielemental analysis was performed with an optimized ICP-QMS method. Aqueous standard solutions were applied for external calibration with rhodium as the internal standard element. The detection limits varied between 0.02–¶0.38 μg/g for Li, Na, Cr, Mn, Ni, Cu, Zn, Sr, Cd, Ba and Pb, and up to 1.92 μg/g for Mg, Al, Ca, Fe and Ni. Digested human plasma samples were spiked with multielemental solution (0.5–10 μg/L) to test the analytical method and the recoveries were 95–105% for most analytes. Our results show that in the case of homogeneous SRMs it is possible to use them in very low amounts (1–5 mg) for method development and quality control.  相似文献   

16.
The application of open vessel focused microwave acid digestion is described for the preparation of geological and environmental samples for analysis using inductively coupled plasma-mass spectrometry (ICP-MS). The method is compared to conventional closed-vessel high pressure methods which are limited in the use of HF to break down silicates. Open-vessel acid digestion more conveniently enables the use of HF to remove Si from geological and plant samples as volatile SiF4, as well as evaporation-to-dryness and sequential acid addition during the procedure. Rock reference materials (G-2 granite, MRG-1 gabbros, SY-2 syenite, JA-1 andesite, and JB-2 and SRM-688 basalts) and plant reference materials (BCR and IAEA lichens, peach leaves, apple leaves, Durham wheat flour, and pine needles) were digested with results comparable to conventional hotplate digestion. The microwave digestion method gave poor results for granitic samples containing refractory minerals, however fusion was the preferred method of preparation for these samples. Sample preparation time was reduced from several days, using conventional hotplate digestion method, to one hour per sample using our microwave method.  相似文献   

17.
A robust, accurate and sensitive analytical procedure for the determination of Se in plant and peat samples by hydride generation-atomic fluorescence spectrometry (HG-AFS) was developed. Aliquots (200 mg) of dried samples were digested with 3 mL nitric acid and 0.5 mL hydrogen peroxide in closed, pressurized PTFE vessels in a microwave oven at 220 °C. Addition of HBF4 or HF to the digestion mixture was not required because experiments demonstrated that Se was not hosted in the silicate fraction of the investigated sample matrices. Selenium(VI) was directly reduced to Se(IV) in the undiluted digestion solutions after addition of 3.8 mL of 4 M HCl in a microwave oven at 103 °C for 3 min. Other reduction reagents, such as hydroxylamine hydrochloride or urea, were not necessary to cope with potential interferences from nitrogen oxides that could hamper the reliable determination of Se by HG-AFS. Optimum hydride generation of Se was achieved by using 0.9% NaBH4 and 4.5 M HCl. A solution detection limit of 11 ng L−1 was obtained under the optimized experimental conditions which corresponds to a method detection limit of 2.8 ng g−1 in solid peat and plant materials. The precision of replicate measurements was better than 3% at Se concentrations of 50 ng L−1. The analytical procedure was critically evaluated by analysing two certified plant reference materials (SRM 1515 Apple Leaves and SRM 1547 Peach Leaves) as well as three peat reference materials. Excellent agreement between the experimental values ranging from 50 ng g−1 to ∼2 μg g−1 and the certified concentrations was obtained.  相似文献   

18.
A procedure for partial digestion of bovine tissue is proposed using polytetrafluoroethylene (PTFE) micro-vessels inside a baby-bottle sterilizer under microwave radiation for multi-element determination by inductively coupled plasma optical emission spectrometry (ICP OES). Samples were directly weighed in laboratory-made polytetrafluoroethylene vessels. Nitric acid and hydrogen peroxide were added to the uncovered vessels, which were positioned inside the baby-bottle sterilizer, containing 500 mL of water. The hydrogen peroxide volume was fixed at 100 µL. The system was placed in a domestic microwave oven and partial digestion was carried out for the determination of Ca, Cu, Fe, Mg, Mn and Zn by inductively coupled plasma optical emission spectrometry. The single-vessel approach was used in the entire procedure, to minimize contamination in trace analysis. Better recoveries and lower residual carbon content (RCC) levels were obtained under the conditions established through a 24-1 fractional factorial design: 650 W microwave power, 7 min digestion time, 50 µL nitric acid and 50 mg sample mass. The digestion efficiency was ascertained according to the residual carbon content determined by inductively coupled plasma optical emission spectrometry. The accuracy of the proposed procedure was checked against two certified reference materials.  相似文献   

19.
The efficiency of oxidation in wet decomposition procedures for organic materials can be of great importance to the quality of the analytical data from various measurement techniques. A novel, microwave-assisted, high-temperature/high-pressure UV-TiO2 digestion procedure was developed for the accelerated decomposition of various biological samples. The technique is based on a closed, pressurized, microwave digestion apparatus (MW). UV irradiation is generated by immersed electrodeless Cd discharge lamp operated by the focused microwave field in the single polymer vessel. To enhance oxidation efficiency, a photocatalyst TiO2 was added to the microwave heated Teflon bomb. Measures of digestion completeness were provided by the appearance of carbon content and determination of trace and minor elements, enabling a comparison of different digestion procedures and sample types. Compared with other digestion systems, unusually low residual carbon contents were obtained. For the organic compounds and biological samples digested, the residual carbon content was 1-2%, corresponding to a decomposition efficiency of 98-99%. The potential of the MW-UV-TiO2 system was illustrated by the decomposition of four certified reference materials (serum, urine, milk, arsenobetaine solution) and subsequent determination of trace and minor elements. Recoveries between 92% and 107% were found.  相似文献   

20.
研究了电感耦合等离子体质谱(ICP-MS)测定大气颗粒物中痕量稀土元素(REEs)的分析方法。在微波条件下,采用HNO3 + H2O2(3 + 1)混合介质能快速而有效地分解颗粒物样品。详细讨论了测定稀土元素的质谱干扰。通过分析不同粒径颗粒物中稀土元素的含量,初步探讨了大气颗粒物中稀土元素的分布规律。结果表明:颗粒物试样的粒径越小,稀土元素的含量越高。分析方法的检出限为0.7~2.8pg/mL,用于大气颗粒物国际标样(SRM 1648)中稀土元素分析,结果与推荐值有良好的一致性。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号