首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 796 毫秒
1.
In a thiocyanate solution containing iron (II), nitrite and ascorbic acid, a linear-sweep polarographic wave appears at ?0.42 V (vs. SCE). In anodic sweeps, the derivative peak current is directly proportional to the concentration of thiocyanate over the range 2×10?8?1×10?6 M; the detection limit is 1×10?8 M. The procedure is used for the determination of trace thiocyanate (10?3?10?4 M) in saliva. The mechanism of the electrode process is discussed; the polarographic wave is ascribed to catalytic reduction of dissolved oxygen in the presence of an adsorbed ternary Fe/SCN/NO complex.  相似文献   

2.
On the basis of a detailed study of the pilocarpine-induced nickel(II) pre-wave using various polarographic techniques, an electrode process mechanism is proposed in which the formation of a catalytic complex between aquo-nickel(II) and veronalate-nickel(II) on the one hand and unprotonated pilocarpine adsorbed on the electrode surface on the other is followed by the reduction of nickel(II) in the complex and the release of the catalytic ligand. The pre-peak recorded by differential-pulse polarography in the system 1 × 10?3 M Ni(II)-1 × 10?2 M sodium veronal, nitric acid (pH 8.5) (with ionic strength maintained at 0.2 with sodium nitrate) can be used for quantitative determination of pilocarpine at concentrations in the range 2.5 × 10?7-8 × 10?6 M.  相似文献   

3.
《Analytical letters》2012,45(7):1743-1751
Abstract

A new method for determining nitrite is proposed. the mechanism for the polarographic waves and the condition for determining nitrite are discussed in this paper. In cathodic sweeps, the peak height is directly proportional to the concentration of nitrite over the range 5×10?9?6×10?7 g/ml, the detection limit is 4×10?9g/ml. the experiments showed that this polarographic wave is an adsorption wave, and useful in determination of nitrite in water sample.  相似文献   

4.
The determination of trace rhenium (VII) by differential pulse polarography in the system of H2SO4-(NHsOH)2 · H2SO4-TeO2?4 is markedly improved by the addition of Nitron, which is adsorbed on the surface of mercury electrode. The limit of detection is down to 2 × 1010 M. The adsorptive peak potential is ?0.80 V (vs. SCE). In the ranges of 5 × 1010—10?8, 1 × 10?5—10?7 and 1 × 10?7—10?6M, there are good linear relationships between the peak current increment and the concentration, of which the relative standard deviations are 9.5, 6.6, 1.8% respectively with the correlation coefficients of linear regression of 0.995–0.999. The results relating to this polarographic wave show that it is an adsorption-catalytic wave. The mechanism of the electrode reaction is discussed.  相似文献   

5.
A differential-pulse polarographic method for the determination of amino acids is reported, based on the formation of Schiff's base compounds in borax buffer solution (pH 10.10) containing acetaldehyde. The compounds are reduced at a mercury electrode with peak potentials of about ?1.5 V (vs. SCE) and well defined polarographic waves are obtained which can be used to determine amino acids in borax medium. The differential-pulse polarographic method was found to be the most sensitive and suitable for the determination of amino acids in the concentration range 1 × 10?6–8 × 10?4 M (lysine) and 2.8 × 10?6–1 × 10?3 M (arginine). The polarographic characteristics of these waves were studied by differential-pulse polarographic and cyclic voltammetric methods. The waves are ascribed to the reduction of the imido group in the Schiff's base compounds. The procedure was applied to the determination of lysine and arginine in foodstuffs and the total proteins in serum samples.  相似文献   

6.
The linear-sweep polarographic determination of active chlorine is based on its reaction with phenylthiourea in acidic phosphate buffer (pH 2.5) containing potassium chloride. The product, C,C-diphenyldithiodiformamidine, is strongly adsorbed and then reduced at a mercury electrode with two peaks at about ?0.35 V and ?0.87 V (vs. SCE). In the presence of 0.05 M potassium chloride, the potential of the first peak shifts positively to ?0.31 V. This peak provides high sensitivity and selectivity for the determination of traces of active chlorine. The linear range is 1×10?7?2.5×10?5 M and the detection limit is 5×10?8 M (3.6 μg l?1). The method is used for the direct determination of active chlorine in tap water. The mechanism of the reaction was studied by cyclic voltammetry, electrolysis and potentiometric titration. The first peak (?0.35 V) is ascribed to the reduction of a mercury (II) sulfide film produced by reaction of the adsorbed dithio product with mercury. In the presence of 0.05 M chloride, the formation of a mixed HgS·xHg2Cl2 film shifts the peak to ?0.31 V.  相似文献   

7.
《Analytical letters》2012,45(3-4):453-459
Abstract

A simple d.c. polarographic method has been developed for the determination of metronidazole in dosages forms. In Robinson - Britton buffer (pH 4.38) and in presence of 1.60 × 10?3 % Triton X-100, the drug produced a well defined 4-electron polarographic wave followed by another wave of about half the height of the first wave. The current is proportional to the concentration and permits the drug to be determined by d.c. polarography in the concentration range 5.0 × 10?5 -7.0 × 10?4 M. Results obtained by the proposed method are in excellent agreement with that provided by the USP-XX method. A rapid, sensitive and accurate polarographic method for the determination of metronidazole in the tablets which are produced locally is proposed.  相似文献   

8.
The polarographic behaviour of cyfluthrin (CY), an α-cynoester pyrethroid, was studied using a dropping mercury electrode and hanging mercury drop electrode in methanolic Britton–Robinson (B–R) buffer of pH 2.0–12.0 with different ionic media. The nature of the electrode process was examined, the number of electrons was evaluated, and the reduction mechanism was proposed. Quantitative determination was achieved in the concentration range of 6.0?×?10?8 to 1.15?×?10?5?mol?dm?3 using a differential pulse polarographic method with a lower detection limit of 2.4?×?10?8?mol?dm?3. The proposed method was successfully applied in the determination of CY in formulations, grains, soils, and spiked water samples.  相似文献   

9.
An organically modified sol‐gel electrode using 3‐aminopropyltrimethoxy silane for covalent immobilization of a redox mediator namely toluidine blue has been reported. Cyclic voltammetric characterization of the modified electrode in the potential range of 0.2 V to ?0.6 V exhibited stable voltammetric behavior in aqueous supporting electrolyte with a formal potential of ?0.265 V vs. SCE, corresponding to immobilized toluidine blue. The electrocatalytic activity of the modified electrode when tested towards nitrite ion exhibited a favorable response with the electrocatalytic reduction of nitrite occurring at a reduced potential of ?0.34 V. A good linear working range from 2.94×10?6 M to 2.11×10?3 M with a detection limit of 1.76×10?6 M and quantification limit of 5.87×10?6 M was obtained for nitrite determination. The stable and quick response (4 s) of the modified electrode towards nitrite under hydrodynamic conditions shows the feasibility of using the present sensor in flow systems. Significant improvements in the operational stability by overcoming the leachability problem and repeatability with a relative standard deviation of 1.8% of the TB thin film sensor have been obtained by the strategy of immobilization of the mediator in the sol‐gel matrix.  相似文献   

10.
It was found that in acidic chloride media the complex of Mo(VI) with 1,10‐phenantroline induces catalytic reduction of KClO3. This catalytic effect can be utilized for sensitive differential pulse polarographic determination of Mo(VI) with a low detection limit of 2.9×10?11 M (2.8 ng/L). The optimal Mo(VI) response was obtained at pH 2.8, in the presence of (6–12)×10?5 M 1,10‐phenantroline and 2×10?2 M KClO3. The sensitivity was 1.73 nA/nM and the catalytic response was linear up to 7.5×10?7 M Mo (VI). The interferences from inorganic ions and surface‐active substances were investigated. The results of the determination of Mo(VI) in CRM water sample showed good reproducibility (R.S.D. for standard solution is below 1.2% and for water samples is 8.9%) and accuracy of the elaborated catalytic polarographic method.  相似文献   

11.
Electrochemical reduction of the dacarbazine‐Cu2+ complex was investigated using cyclic voltammetry and square wave voltammetry at a hanging mercury drop electrode. The reduction of the dacarbazine‐Cu2+ complex is irreversible. A reduction mechanism is proposed comprising a one‐electron reduction of the Cu2+ directly within the complex. The sharp peak of the adsorbed dacarbazine‐Cu2+ complex associated with an effective interfacial accumulation facilitates the determination of the anticancer drug dacarbazine in pharmaceutical formulations and biological fluids. Detection limits for dacarbazine of 6.12×10?10 M, 1.57×10?10 M and 1.97×10?9 M were achieved for the determination of the drug in vial, human urine and serum, respectively.  相似文献   

12.
A lead film plated in situ at a carbon paste support was tested as a novel, potential electrode for adsorptive stripping voltammetric determination of cobalt traces in an ammonia buffer solution. To show the practical applicability of the new electrode, a catalytic adsorptive Co system in a supporting electrolyte containing 0.1 M ammonia buffer, 5×10?4 M nioxime and 0.25 M nitrite was selected and investigated as a model solution. Pb and Co ions were simultaneously accumulated in situ on the electrode surface: Pb ions electrochemically at ?1.3 V) and then at ?0.75 V, at which potential the Co(II)‐nioximate complex was also pre‐concentrated via adsorption. Instrumental parameters, such as the time of nucleation and formation of Pb film deposits, the time of accumulation of the Co‐nioxime complex at the PbF/CPE, and the procedures of electrode regeneration, were optimized to obtain good reproducibility and sensitivity of the Co response. The optimized procedure yields favorable and highly stable stripping responses with good precision (RSD=3% for a 5×10?8 M Co) and good linearity (up to 5×10?7 M, coefficient of determination, R=0.996). The detection limit was 4×10?10 M Co (0.023 μg L?1) for an accumulation time of 120 s. The method enables the determination of Co in the presence of high excesses of Ni or Zn. The voltammetric data were correlated with the structural characterization by scanning electron microscopy (SEM) and X‐ray fluorescence spectroscopy (XRF).  相似文献   

13.
The results of a study on the polarographic behaviour of TBP and its influence on the determination of uranyl ions is presented. The half-wave potential of the adsorption wave of TBP depends on the concentration of TBP, type of supporting elec trolyte and its concentration. In the presence of TBP the polarographic wave of U(VI) ion is changed. Below 7·10?5 M TBP the polarographic wave of U(VI) is not affected, between 7·10?5 and 2·10?4 M TBP the shape, height and half-wave potential of U(VI) waves are changed and above 2·10?4 M, up to saturated solution of TBP, the waves of U(VI) do, not change further. The bes supporting electrolytes for the determination of U(VI) are KNO3 or NaClO4 in concentrations of 0.1 to 0.5 M, pH 1–2 and TBP concentrations from 3·10?4 to 1.2·10?3 M.  相似文献   

14.
《Analytical letters》2012,45(7):1208-1224
Abstract

This paper describes development of a new analysis system for determination of lorazepam by a novel square wave voltammetry method to perform a very sensitive method. The method used for determination of lorazepam involves measuring the changes in admittance voltammogram of a gold ultramicroelectrode (in 0.05 M H3PO4 solution) caused by adsorption of the lorazepam on the electrode surface. Variation of admittance in the detection process is created by inhibition of oxidation reaction of the electrode surface, by adsorbed lorazepam. Furthermore, signal-to-noise ratio is significantly increased by application of discrete fast Fourier transform (FFT) method, background subtraction, and two-dimensional integration of the electrode response over a selected potential range and time window. Also in this work, some parameters such as SW frequency, eluent pH, and accumulation time were optimized. Calibration plots are given for solutions containing 10?6–10?11 M of lorazepam. The detection limit is calculated to be 6.0 × 10?12 M (~ 2 pg/ml). The relative standard deviation at concentration 3.0 × 10?8 M is 6.1% for 5 reported measurements.  相似文献   

15.
An electroanalytical method for the simultaneous determination of paracetamol (PAR), caffeine (CAF), and orphenadrine (ORPH) using the square‐wave voltammetry (SWV) and a cathodically pretreated boron‐doped diamond electrode was developed. The method exhibits linear responses to PAR, CAF, and ORPH in the concentration ranges 5.4×10?7–6.1×10?5 M, 7.8×10?7–3.5×10?5 M, and 7.8×10?7–3.5×10?5 M, respectively, with detection limits of 2.3×10?7 M, 9.6×10?8 M, and 8.4×10?8 M, respectively. The proposed method was successfully applied in the simultaneous determination of these analytes in pharmaceutical formulations.  相似文献   

16.
The differential pulse polarographic behaviour of 2,4,6-trinitrophenyl (TNP) derivatives of several primary amines and amino acids was investigated in the presence of sulphite ion. All the derivatives produced a polarographic peak for their complexes with sulphite (1 × 10?2 M) in pH 8.0 phosphate buffer (0.05 M)/0.1 M potassium chloride. The derivatives of proteins and peptides did not give such a peak. A 5-min reaction time at room temperature (or 50°C for lysine) and pH 10.5 using 1 × 10?4 M 2,4,6-trinitrobenzene-1-sulphonic acid provides the optimal conditions for the determination of 5 × 10?6?2.5 × 10?5 M amines. The relative standard deviation for determining 1 × 10?5 M glycine (n = 5) was 1%.  相似文献   

17.
For the first time, a novel carbon nanotube bed electrode impregnated with silver–nanoparticles (AgNPs) for the determination of trace amounts of gabapentin (GBP) is described. We synthesized the AgNPs via a new procedure. The voltammetric behavior of the electrode was investigated by cyclic voltammetry. There were linear relationships in the ranges from 3.1×10?9 to 2.9×10?2 M and from 1.0×10?8 to 1.0×10?2 GBP with square wave and differential pulse voltammetric peak currents, respectively. The detection limits were 5.6×10?10 and 9.7×10?9 M, respectively. The electrode showed excellent response over a period of 2 months and was successfully applied in human plasma and pharmaceutical capsular products.  相似文献   

18.
A method for the determination of trace amounts of silver with a chemically modified carbon paste electrode is described. The modified electrode is prepared by simply mixing a chelating resin (a polythioether backbone and dioxymonosulphur polyethylene polyimines in the side-chain polymer) with graphite powder and Nujol oil. By immersing the electrode in a silver sample solution (pH = 6.5–7.5), silver can be adsorbed on the electrode surface and then determined by voltammetry in a separate blank solution. The response depends on the concentration of silver and the preconcentration time. For a preconcentration time of 5 min, the detection limit is about 3 × 10?10 M and the linear range is from 5 × 10?10 to 1 × 10?7 M with a relative standard deviation of 4%. Many common metal ions have no or little effect on the determination of silver. The recommended procedure was applied to the determination of trace amounts of silver in waste water.  相似文献   

19.
《Analytical letters》2012,45(4):595-606
A highly sensitive polyvinyl chloride (PVC) membrane electrode, based on copper(II)-bis(N-4-methylphenyl-salicyldenaminato) complex, (CuL2), as a carrier was reported for the determination of chromate ion. The influence of membrane composition, pH, and possible interfering anions on the response of the ion selective electrode was investigated. The sensor exhibited a Nernstian slope of 29.7 mV per decade when the chromate concentration was varied between 2.0 × 10?7–1.50 × 10?2 M in a wide pH range (6.0 to 9.0). The detection limit of the ion selective electrode was 9.2 × 10?8 M. The proposed sensor was used for at least 4 months without any considerable divergence in potential. It was applied as indicator electrode in potentiometric titration of chromate ion with Pb2+ and Tl+.  相似文献   

20.
《Analytical letters》2012,45(10):831-840
Abstract

An indirect polarographic method is described based on the alprade reaction. The formaldehyde produced is determined by its decrease of the hydroxylamine a-c polarographic wave. Sorbitol, ethanediol, mannitol, ethanolamine, serine and threonine are determined in the range 5 – 30 × 10?6 M while 2.5 – 10 × 10?6 M triethanolamine are determinable.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号