共查询到20条相似文献,搜索用时 15 毫秒
1.
Frédéric Destaillats Cristina Cruz-HernandezKornél Nagy Fabiola Dionisi 《Journal of chromatography. A》2010,1217(9):1543-1548
Monoacylglycerols (MAGs) are lipids found in trace amounts in plants and animal tissues. While they are widely used in various industrial applications, accurate determination of the regio-specific distribution is hindered by the lack of stable, commercially available standards. Indeed, unsaturated β-MAG (or Sn-2 MAG) readily undergoes isomerization into α-MAG (acyl chain is attached to the Sn-1 or the Sn-3 position). In the present study, we describe structural elucidation of α- and β-regio-isomers of monopalmitoyl-glycerol (MAG C16:0) as model compounds in their silylated forms using gas chromatography–mass spectrometry (GC–MS) with electronic impact (EI) ionization. MS fragmentation of α-MAG C16:0 is characterized by the loss of methylene(trimethylsilyl)oxonium (103 amu) and the consecutive loss of acyl chain yielding a fragment ion at m/z 205. The fragmentation pattern of β-MAG C16:0 shows a series of diagnostic fragments at m/z 218, 203, 191 and 103 that are not formed from the α-isomer and hereby enable reliable distinction of these regio-isomers. Possible fragmentation scenarios are postulated to explain the formation of these marker ions, which were also applied to characterize the regio-isomer composition of a complex mixture of MAG sample containing n-3 long-chain polyunsaturated fatty acids. 相似文献
2.
Dan Li Anthony D. Rands Scott C. Losee Brian C. Holt John R. Williams Stephen A. Lammert Richard A. Robison H. Dennis Tolley Milton L. Lee 《Analytica chimica acta》2013
An automated sample preparation system was developed and tested for the rapid detection of Bacillus anthracis endospores by gas chromatography–mass spectrometry (GC–MS) for eventual use in the field. This reactor is capable of automatically processing suspected bio-threat agents to release and derivatize unique chemical biomarkers by thermochemolysis (TCM). The system automatically controls the movement of sample vials from one position to another, crimping of septum caps onto the vials, precise delivery of reagents, and TCM reaction times and temperatures. The specific operations of introduction of sample vials, solid phase microextraction (SPME) sampling, injection into the GC–MS system, and ejection of used vials from the system were performed manually in this study, although they can be integrated into the automated system. Manual SPME sampling is performed by following visual and audible signal prompts for inserting the fiber into and retracting it from the sampling port. A rotating carousel design allows for simultaneous sample collection, reaction, biomarker extraction and analysis of sequential samples. Dipicolinic acid methyl ester (DPAME), 3-methyl-2-butenoic acid methyl ester (a fragment of anthrose) and two methylated sugars were used to compare the performance of the autoreactor with manual TCM. Statistical algorithms were used to construct reliable bacterial endospore signatures, and 24 out of 25 (96%) endospore-forming Bacillus species were correctly identified in a statistically designed test. 相似文献
3.
van der Werf ID Germinario G Palmisano F Sabbatini L 《Analytical and bioanalytical chemistry》2011,399(10):3483-3490
Pyrolysis gas chromatography–mass spectrometry (PyGC-MS) was used as a rapid method for the characterization of permanent
marker ink. Twenty-four samples of various colours purchased from different manufacturers were characterised. Four main typologies
of polymer-binding medium could be distinguished on the basis of the pyrolysis products, and differentiation between permanent
markers of different manufacturers could be accomplished. For some permanent marker samples, PyGC-MS analysis allowed pigment
identification as well. 相似文献
4.
This review article underlines the detection-oriented derivatization of neutral steroids in liquid chromatography-mass spectrometry (LC-MS). Steroids have strong biological activity at very low concentrations in target tissues and, therefore, the analysis of steroids in body fluids or tissues is necessary to elucidate the nature of the many endocrine disease processes and thus be useful for diagnosis and treatment. LC-MS has recently been used for steroid analysis because of its specificity and versatility, but the ionization efficiencies of most steroids are relatively low for the different ionization methods. Derivatization enhances the ionization efficiencies of steroids, leading to high sensitivity and specific detection. For electrospray ionization MS the introduction of permanently charged moieties or easily ionizable moieties effectively increases the sensitivity of detection of steroids. The introduction of moieties with proton affinity or electron affinity enhances the analyte signals in positive and negative atmospheric pressure chemical ionization MS, respectively. 相似文献
5.
Presumable structures of polyethanolamines, synthesized by the catalytic β-hydroxyethylation of ammonia with an excess of ethylene oxide are determined by gas chromatography–electron ionization mass spectrometry and tandem mass spectrometry qualitatively, following fragmentation ways and also taking into account retention data. The preferable paths of consecutive reactions of the synthesis of polyethanolamines in a homologous series of isomers are found. 相似文献
6.
7.
A novel selectable one-dimensional (1D) or two-dimensional (2D) gas chromatography–mass spectrometry (selectable 1D/2D GC–MS) system with selective detection was developed by using capillary flow technology and low thermal mass GC (LTM-GC). The main advantages of this system are the simple and fast selection of 1D GC–MS or 2D GC–MS operation without any instrumental set-up change (e.g.2D GC–MS can be run just after 1D GC–MS run), and simultaneous mass spectrometric and olfactometry or element-specific detection for both 1D and 2D separation to assure selection of a heart-cut region and correct identification of compounds of interest. The feasibility and benefit of the proposed system with selective detection, e.g. olfactometry, nitrogen phosphorus detection (NPD), and pulsed flame photometric detection (PFPD), was demonstrated with an identification of trace amounts of aroma components in beverages (beer and coffee). Using stir bar sorptive extraction (SBSE) and selectable 1D/2D GC–Olfactometry/MS on a beer sample, β-damascenone could be determined at 1.9 ng mL−1 (RSD 3.1%, n = 6) as a potent aroma compound. In a coffee sample, two odor active compounds were clearly resolved from a 4.2 s heart-cut and were assigned probable identifications as 4,5-dimethyl thiazole and dimethyl trisulfide based on a NIST library search, dual linear retention indices (dual LRI) and elemental information obtained by SBSE in combination with selectable 1D/2D GC–NPD/PFPD/MS. 相似文献
8.
Stefan Otto Thorsten Streibel Sabrina Erdmann Martin Sklorz Detlef Schulz-Bull Ralf Zimmermann 《Analytica chimica acta》2015
A novel analytical system for gas-chromatographic investigation of complex samples has been developed, that combines the advantages of several analytical principles to enhance the analytical information. Decomposition of high molecular weight structures is achieved by pyrolysis and a high separation capacity due to the chromatographic step provides both an universal as well as a selective and sensitive substance detection. The latter is achieved by simultaneously applying electron ionization quadrupole mass spectrometry (EI-QMS) for structural elucidation and [1 + 1]-resonance-enhanced-multi-photon ionization (REMPI) combined with time-of-flight mass spectrometry (ToFMS). The system has been evaluated and tested with polycyclic aromatic hydrocarbon (PAH) standards. It was applied to crude oil samples for the first time. In such highly complex samples several thousands of compounds are present and the identification especially of low concentrated chemical species such as PAH or their polycyclic aromatic sulfur containing heterocyclic (PASH) derivatives is often difficult. Detection of unalkylated and alkylated PAH together with PASH is considerably enhanced by REMPI–ToFMS, at times revealing aromatic structures which are not observable by EI-QMS due to their low abundance. On the other hand, the databased structure proposals of the EI-QMS analysis are needed to confirm structural information and isomers distinction. The technique allows a complex structure analysis as well as selective assessment of aromatic substances in one measurement. Information about the content of sulfur containing compounds plays a significant role for the increase of efficiency in the processing of petroleum. 相似文献
9.
Esposito S Deventer K T'Sjoen G Vantilborgh A Delbeke FT Goessaert AS Everaert K Van Eenoo P 《Analytical and bioanalytical chemistry》2012,402(9):2789-2796
This work describes a liquid chromatography–electrospray tandem mass spectrometry method for detection of desmopressin in
human plasma in the low femtomolar range. Desmopressin is a synthetic analogue of the antidiuretic hormone arginine vasopressin
and it might be used by athletes as a masking agent in the framework of blood passport controls. Therefore, it was recently
added by the World Anti-Doping Agency to the list of prohibited substances in sport as a masking agent. Mass spectrometry
characterization of desmopressin was performed with a high-resolution Orbitrap-based mass spectrometer. Detection of the peptide
in the biological matrix was achieved using a triple-quadrupole instrument with an electrospray ionization interface after
protein precipitation, weak cation solid-phase extraction and high performance liquid chromatography separation with an octadecyl
reverse-phase column. Identification of desmopressin was performed using three product ions, m/z 328.0, m/z 120.0, and m/z 214.0, from the parent ion, m/z 535.5. The extraction efficiency of the method at the limit of detection was estimated as 40% (n = 10), the ion suppression as 5% (n = 10), and the limit of detection was 50 pg/ml (signal-to-noise ratio greater than 3). The selectivity of the method was
verified against several endogenous and synthetic desmopressin-related peptides. The performance and the applicability of
the method were tested by analysis of clinical samples after administration of desmopressin via intravenous, oral, and intranasal
routes. Only after intravenous administration could desmopressin be successfully detected. 相似文献
10.
11.
Jian-Hua Wang Chun-Shan Quan Xiao-Hui Qi Xin Li Sheng-Di Fan 《Analytical and bioanalytical chemistry》2010,396(5):1773-1779
Bacteria communicate with each other by a process termed “quorum sensing” (QS), and diffusible, low-molecular-weight chemicals,
called signal molecules, are used as the communication languages. In cell-free Burkholderia cepacia CF-66 culture supernatants, five compounds suspected of being signal molecules were identified. The gene (cepI) related with AHLs synthesis were not detected by polymerase chain reaction (PCR) using specific primers. Gas chromatography–mass
spectrometry (GC–MS) revealed that these compounds were not AHLs but the diketopiperazines (DKPs) cyclo(Pro–Phe), cyclo(Pro–Tyr),
cyclo(Ala–Val), cyclo(Pro–Leu), and cyclo(Pro–Val), all of which were both d and l-type. Four kinds of DKPs had been isolated from other Gram-negative bacteria, but the other was a novel kind discovered in
CF-66, and l-cyclo (Pro–Phe) was quantified by GC–MS. It was found that exogenous DKPs had a negative effect on the candidacidal activity
of the culture supernatant extracts. 相似文献
12.
Manuela Reitz Heike Gerhardt Christian Schmitt Oliver Betz Klaus Albert Michael Lämmerhofer 《Analytica chimica acta》2015
This article reports on the chemical analysis of molecular profiles of tarsal secretions of the desert locust Schistocerca gregaria (Forsskål, 1775) by gas chromatography hyphenated with quadrupol mass spectrometry (GC–MS) as well as 1H-nuclear magnetic resonance (1H NMR) spectroscopy. Special focus of this study was to elaborate on sampling methods which enable selective microscale extraction of insect secretions in a spatially controlled manner, in particular tarsal adhesive secretions and secretions located on cuticle surfaces at the tibia. Various solvent sampling procedures and contact solid-phase microextraction (SPME) methods were compared in terms of comprehensiveness and extraction efficiencies as measured by signal intensities in GC–MS. Solvent sampling with water as extraction solvent gave access to the elucidation of chemical profiles of polar compound classes such as amino acids and carbohydrates, but is extremely tedious. Contact SPME on the other hand can be regarded as a simplified and more elegant alternative, in particular for the lipophilic compound fraction. Many proteinogenic amino acids and ornithine as well as carbohydrate monomers arabinose, xylose, glucose, and galactose were detected in tarsal secretions after acid hydrolysis of aqueous extracts. Qualitatively similar but quantitatively significantly different molecular profiles were found for the lipid fraction which contained mainly n-alkanes and internally branched monomethyl-, dimethyl-, and trimethyl-alkanes in the C23–C49 range as well as long chain fatty acids and aldehydes. Especially, hydrocarbons with >C40 carbon numbers have previously been rarely reported for insect secretions. The results suggest that the investigated insect secretions are complex emulsions which allow the attachment of tarsi on various otherwise incompatible materials of smooth and rough surfaces. The solid consistence of the established alkanes at ambient temperatures might contribute to a semi-solid consistence of the adhesive, amalgamating partly opposing functions such as slip resistance, tarsal release, desiccation resistance, and mechanical compliance. The methods developed can be extended to other similar applications of studying compositions of insect secretions of other species. 相似文献
13.
A method based on gas chromatography-mass spectrometry analysis of acetylated methyl glycosides was developed in order to analyze monosaccharides obtained from various hemicelluloses. The derivatives of monosaccharide standards, arabinose, glucose, and xylose were studied in detail and (13)C-labeled analogues were used for identification and quantitative analysis. Excellent chromatographic separation of the monosaccharide derivatives was found and identification of the anomeric configuration was feasible through a prepared and identified pure methyl 2,3,4,6-tetra-O-acetyl-β-D-glucopyranoside. The electron ionization mass spectrum and fragmentation path was studied for each monosaccharide derivative. Fragment ion pairs of labeled and unlabeled monosaccharides were used for quantification; m/z 243/248 for glucose, 128/132 for xylose, and 217/218 for arabinose. Using the intensity ratios obtained from the extracted ion chromatograms, accurate quantification of monosaccharide constituents of selected hemicelluloses was demonstrated. 相似文献
14.
Michał Brokl Ana Cristina Soria Isabel Martínez-Castro Maria Luz Sanz Ana Isabel Ruiz-Matute 《Journal of chromatography. A》2009,1216(22):4689-4692
Gas chromatography (GC) data (linear retention indices and relative areas) and mass spectra (most representative m/z fragments) of 12 reducing trisaccharides as trimethylsilyl oximes (TMSO) and four non-reducing as trimethylsilyl (TMS) ethers have been described for the first time and related to their structural features. Some trends have been observed: earlier elution of non-reducing compounds and fructotrioses; aldotrioses bearing the reducing end with link in position 6 showing the highest retention. Abundance of several fragment ions and their ratios were useful for trisaccharide characterization; some of these features seem to be useful for the characterization of new trisaccharides. 相似文献
15.
A preliminary investigation using gas chromatography–mass spectrometry (GC–MS) to analyze the nicotine contained in tobacco leaves was carried out. Nicotine is an alkaloid and tobacco leaves was extracted with methanol and determined by GC–MS. The detection limit for nicotine was at the ppm level for non selective monitoring and the nanogram level for selective detection. This is a simple chromatography–mass spectrometry method for the analysis of nicotine in tobacco leave. Compared to other currently utilized methods for the detection of nicotine in tobacco leaves, the GC–MS provided advantages of high sensitivity, nicotine specific detection and lower instrumentation cost. 相似文献
16.
Jingming Wu Ruikang HuJunqi Yue Zhaoguang YangLifeng Zhang 《Journal of chromatography. A》2009,1216(7):1053-1058
Injection-port derivatization combined with solid-phase extraction (SPE) was developed and applied for the first time to determine five types of fecal sterols (coprostanol, cholestanol, epicholestanol, epicoprostanol and cholesterol) with gas chromatography–mass spectrometry (GC–MS). In this method, silylation of fecal sterols was performed with N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) at GC injection-port. The factors influential to this technique such as injection-port temperature, purge-off time, derivatization reagent (BSTFA) volume, and the type of organic solvent were investigated. In addition, the conditions of SPE (including the type of SPE cartridge, the type of elution organic solvent) were also studied. After SPE followed by injection-port silylation by GC–MS, good linearity of analytes was achieved in the range of 0.02–10 ng/mL with coefficients of determination, R2 > 0.995. Good reproducibility was obtained with relative standard deviation less than 19.6%. The limits of detection ranged from 1.3 ng/mL to 15 ng/mL (S/N = 3) in environmental water samples. Compared with traditional off-line silylation of fecal sterols performed with water bath (60 °C, 30 min), this injection-port silylation method is much simpler and convenient. The developed method has been successfully applied for the analysis of fecal sterols from real environmental water samples. 相似文献
17.
Deepesh Kumar Singh Sunil Kumar Sanghi Sorna Gowri Navin Chandra Shail Bala Sanghi 《Journal of chromatography. A》2011,1218(33):5683-5687
A simple and highly sensitive gas chromatographic method has been developed for the determination of low molecular weight short-chain aliphatic amines (SCAAs) after their simultaneous extraction and in-syringe derivatization with pentafluorobenzoyl chloride (PFBOC). Derivatization of the low molecular weight aliphatic amines in bicarbonate buffer of pH 10.5 with PFBOC was followed by immersed solvent microextraction. Derivatization conditions, including reagent concentration, reaction pH, ionic concentration of buffer, reaction time, stirring rate, reaction temperature and extraction solvent, have been investigated for method optimization. Linearity was studied within range of 0.15 pg ml−1–50 ng ml−1. The correlation coefficients were between 0.9934 and 0.9999. Detection limit of derivatized amines proved to be in the range of 0.117–1.527 pg ml−1, and the intraday and interday relative standard deviation (RSD) values were less than 8% with respect to peak area. The method was applied for analysis of lake, river and industrial waste water. The recoveries of extraction from lake, river and industrial waste water samples, which have been spiked with different levels of aliphatic amines, were in the range of 68–99%, 63–102% and 62–105%, respectively. 相似文献
18.
Comparative study of extraction techniques for determination of garlic flavor components by gas chromatography–mass spectrometry 总被引:5,自引:0,他引:5
Several sampling techniques based on steam distillation (SD), simultaneous distillation and solvent extraction (SDE), solid-phase trapping solvent extraction (SPTE), and headspace solid-phase microextraction (HS-SPME) have been compared for the determination of Korean garlic flavor components by gas chromatography–mass spectrometry (GC–MS). Diallyl disulfide (57.88%), allyl sulfide (23.59%), and diallyl trisulfide (11.40%) were found to be the predominant flavor components of garlic samples extracted by SDE whereas these components were at levels of 89.77%, 2.43%, and 3.89% when the same sample was extracted by SD, 97.77%, 0.17%, and 0.10% by SPTE, and 97.85%, 0.01%, and 0.01% by HS-SPME using the 50/30-m divinyl benzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) fiber. Thermal degradation of components such as allyl methyl sulfide, dimethyl disulfide, and thiirane were observed for SDE and SD but not for SPTE or HS-SPME. HS-SPME had several advantages compared with SD, SDE, and SPTE—rapid solvent-free extraction, no apparent thermal degradation, less laborious manipulation, and less sample requirement. Five different fiber coatings were evaluated to select a suitable fiber for HS-SPME of garlic flavor components. DVB/CAR/PDMS was most efficient among the five types of fiber investigated. 相似文献
19.
Doménech-Carbó MT Osete-Cortina L de la Cruz Cañizares J Bolívar-Galiano F Romero-Noguera J Fernández-Vivas MA Martín-Sánchez I 《Analytical and bioanalytical chemistry》2006,385(7):1265-1280
The alterations produced by microbiological attack on terpenoid resin-based varnishes from panel and canvas paintings have
been evaluated using pyrolysis–gas chromatography–mass spectrometry (Py–GC–MS) and gas chromatography–mass spectrometry (GC–MS).
The proposed methods include the on-line derivatisation of drying oils and diterpenoid resins using hexamethyldisilazane during
pyrolysis and the application of methyl chloroformate as a derivatisation reagent for triterpenoid resins in GC–MS. Two types
of specimens, consisting of model oil medium prepared from linseed oil and model spirit varnishes prepared from colophony
and mastic resins dissolved in turpentine, have been used as reference materials. For a series of specimens upon which different
genera of bacteria and fungi were inoculated and encouraged to grow, analyses indicated that no mechanisms that commonly occur
during the attack of enzymes on drying oils and terpenoid biodegraders were observed to occur in the oil medium and varnishes
studied. Thus, the degradation pathways observed in the performed trials usually occur as consequence of natural ageing. Specific
trials consisting of the application of biocides to uninoculated colophony varnish resulted in the identification of processes
that produce undesirable degradation of the varnish due to interactions between the biocide and the varnish components. Finally,
the studied biocides—Biotin, New-Des and Nipagine—generally exhibited good inhibiting effects on the microorganisms studied,
although some interesting differences were found between them regarding the application method and type of biocide. 相似文献
20.
Buszewski B Ligor T Jezierski T Wenda-Piesik A Walczak M Rudnicka J 《Analytical and bioanalytical chemistry》2012,404(1):141-146
In this work, a chromatographic method for identification of volatile organic compounds was compared with canine recognition. Gas chromatography and mass spectrometry (GC-TOF MS) were used for determination of concentrations of trace gases present in human breath. The technique enables rapid determination of compounds in human breath, at the parts per billion level. Linear correlations were from 0.83-234.05 ppb, the limit of detection was the range 0.31-0.75 ppb, and precision, expressed as relative standard deviation (RSD), was less than 10.00 %. Moreover, trained dogs are able to discriminate breath samples of patients with diagnosed cancer. We found a positive correlation between dog indications and the ethyl acetate and 2-pentanone content of breath (r = 0.85 and r = 0.97, respectively). The methods presented for detection of lung cancer markers in exhaled air could be used as a potential non-invasive tool for screening. In addition, the canine method is relatively simple and inexpensive in comparison with chromatography. 相似文献