首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 10 毫秒
1.
The paper represents results on numerical investigation of flow and heat transfer between two isothermal vertical plates under laminar natural convection. A system of complete Navier–Stokes equations is solved for a two-dimensional gas flow between the plates along with additional rectangular regions (connected to inlet and outlet sections), whose characteristic sizes are much greater than the spacing between the plates. The calculations were performed over very wide ranges of Rayleigh number Ra = 10 ÷ 105 and a relative channel length AR = L/w = 1 ÷ 500. The influence of the input parameters on the gas-dynamic and thermal structure of thermogravitational convection, the local and mean heat transfer, and also the gas flow rate between the plates (convective draft. We determined sizes of the regions and regime parameters when the local heat flux on the walls tends to zero due to the gas temperature approach to the surface temperature. It is shown that the mean heat transfer decreases as the relative channel length AR grows, whereas the integral gas flow rate (convective draft) and Reynolds number in the channel Re = 2wUm/ν increase. The use of a modified Rayleigh number Ra* = Ra · (w/L) (Elenbaas number) leads to generalization of calculation data on mean heat transfer. These data are in good agreement with the correlations for heat transfer [1, 2] and gas flow rate [3]. The reasons of variation of the data in the range of low Rayleigh numbers are discussed in detail.  相似文献   

2.
Results of numerical investigation of the flow and heat transfer at turbulent free convection between the vertical parallel isothermal plates with different temperatures are presented. The temperature factor R T varied within ?2 ÷ 1. The Rayleigh number changed within Ra = 107 ÷ 109, and the ratio of geometrical sizes of plates and distances between them was constant A = L/w = 10. Numerical studies were performed via the solution to the two-dimensional Navier—Stokes equations and energy equation in Boussinesq approximation. The considered boundary-value problem has the unknown conditions at the inlet and outlet between the plates. To describe turbulence, the modified low-Reynolds k-? model was used. The effect of the temperature factor on the flow structure at the channel inlet and outlet was analyzed. Data on distributions of velocities and temperatures between the plates, local and integral heat transfer allow deeper understanding of the mechanism of transfer processes between the parallel plates with asymmetrical heating.  相似文献   

3.
The results of numerical computations of a free laminar convection and heat transfer between two parallel isothermal plates in the presence of a single rib on the channel surface are presented. The investigations have been conducted for a channel with the aspect ratio AR = L/w = 10, where L is the channel height, and w is the distance between the plates. An infinitely thin adiabatic rib was located on one of the channel walls in the middle of its height. The relative rib height l/w was varied in the range 0÷0.8. The wall temperature was higher than the ambient temperature, and the Rayleigh number was varied in the range Ra = 102÷105. The main attention has been paid to the study of the influence of the rib height and the Rayleigh number on local and integral heat transfer and the Reynolds number in the channel (the convective thrust). A fundamental difference in the heat transfer over the channel height has been shown on the ribbed wall and on a smooth surface. The computational results have been compared with the case of a symmetric distribution of the ribs on the both walls with the integral height equal to a single rib.  相似文献   

4.
Numerical investigation of laminar free convection heat transfer in the vertical parallel plate channel with asymmetric heating is presented. Both inlet and exit effects are included into the analysis. A numerical solution is obtained for a Prandtl number of 0.71 and for modified Rayleigh number [`(Ra)]\overline {Ra} = 10−1 ÷ 105, and varying heating ratio TR = 0 ÷ 1 and aspect ratio A = 10. Fully elliptic Navier-Stokes and energy equations are solved using the finite volume techniques with staggered grid arrangements. The obtained results show a strong influence of the temperature ratio on local and average heat transfer coefficient on the hot and cold plates. With reduction of TR the heat transfer parameter on the hot wall grows, and on the cold one, on the contrary, it decreases. As a result, the total heat exchange from two plates depends poorly on the parameter TR.  相似文献   

5.
针对大功率LED光源存在的散热问题,在风冷散热条件下,对加装导流罩的大功率LED散热器进行优化设计。在肋片结构参数固定的条件下,利用流体分析软件对导流罩的内径、高度、进气口直径以及散热器肋片夹角进行优化。通过改变这些参数来改变散热片表面气体流体的流形、风速等值,最终改变肋片表面对流换热系数。获得的导流罩和肋片夹角参数:导流罩高度85 mm,进气口直径76 mm,出气口直径83 mm,散热器肋片夹角9。通过优化使散热器温度有一定程度的降低,为大功率LED灯具散热设计提供了一种优化方案。  相似文献   

6.
Abstract

An experimental study is carried out to investigate the effect of entrance and exit conditions that prevail due to different flow arrangements on the thermal performance of a copper micro-channel heat sink. Three flow arrangements—U-type, S-type, and P-type—were considered for the analysis with a test piece having inlet and outlet plenum dimensions of 10 mm × 30 mm × 2.5 mm with an array of parallel micro-channels having an individual width of 330 μm and a uniform channel depth of 2.5 mm. Performance evaluations for different flow conditions at inlet and outlet plenums were made by maintaining constant heat supply at 125 W, 225 W, and 375 W with varying Reynolds number ranging from 224 to 1,121. Nusselt number and pressure drop were computed by measuring temperature difference and pressure drop across the inlet and outlet plenum for various test combinations. Maximum heat transfer was observed for the U-type flow arrangement, followed by the P-type and S-type; maximum pressure drop was noted for the S-type flow arrangement, followed by the U-type and P-type arrangements for a constant Reynolds number. A detailed analysis of the experimental results indicate that from a pressure drop point of view, the P-type flow arrangement is preferred, whereas from the heat transfer point of view, the U-type is found to be a better option.  相似文献   

7.
The flow boiling heat transfer of water in a microchannel heat sink with variable initial vapor quality at the inlet is investigated. The stainless steel microchannel heat sink contains ten 640 × 2050 μm channels with a length of 120 mm; the wall roughness is 10 μm. The data on the local heat-transfer coefficient distribution in heat sink length are obtained in the range of mass fluxes from 30 to 90 kg/m2s, heat fluxes from 40 to 170 kW/m2, and vapor qualities from 0 to 1. The heat transfer instability associated with dry spots resulting from insufficient wetting of channel walls introduces substantial contribution to the heat transfer mechanism and leads to decreasing heat transfer in heat sink length downward the flow. The developed method for calculating the flow boiling heat transfer of water in a microchannel heat sink allows more accurate prediction of heat transfer drop than available methods.  相似文献   

8.
Ultrasound is considered to be an effective active heat transfer enhancement method, which is widely used in various fields. But there is no clear understanding of flow boiling heat transfer characteristics in micro/mini-channels under ultrasonic field since the studies related are limited up to now. In this paper, a novel minichannel heat exchanger with two ultrasonic transducers inside the inlet and outlet plenum respectively is designed to experimentally investigate the impacts of ultrasound on flow boiling heat transfer enhancement in a minichannel heat sink. Flow visualization analyses reveal that ultrasound can promote rapid bubble motion, bubble detachment from heating wall surface and thereby new bubble generation, and decrease the length of confined bubble. Furthermore, the flow boiling experiments are initiated employing working fluid R141b at different ultrasonic parameters (e.g., frequency, power, angle of radiation) and heat flux under three types of ultrasound excitations: no ultrasound (NU), single inlet ultrasound (IU), inlet and outlet ultrasound (IOU). The results indicate that ultrasound has obvious augmentation effects on flow boiling heat transfer even though the intensification effects will be limited with the heat flux increases. The higher ultrasonic power, the lower ultrasonic frequency and the higher ultrasonic radiation angle, the better intensification efficiency. The maximum enhancement ratio of have in the saturated boiling section reaches 1.88 at 50 W, 23 kHz and 45° under the experimental conditions. This study will be beneficial for future applications of ultrasound on flow boiling heat transfer in micro/mini-channels.  相似文献   

9.
The purpose of this paper is to investigate, numerically, the effect of internal fins on the flow pattern, temperature distribution and heat transfer between concentric horizontal cylinders. A Galerkin finite element method is adopted for the discretization of the governing equations. The numerical procedure consists in solving series of transient problems of increasing Ra. Results are presented using air (Pr = 0.7) with Rayleigh numbers ranging from 103 to 106 for different fin configurations (1 and 2), geometries (sharp, round and divergent tip) and lengths (l = 0.25, 0.5 and 0.75). They are illustrated in terms of isotherms, velocity fields, Nusselt numbers and fin efficiencies. Configuration 2 presents a heat transfer rate 10% above that of configuration 1, at Ra = 106. The heat transfer is about the same for the three geometries, but the best fin efficiency is associated with the fin with a round tip.  相似文献   

10.
An experimental study of mixed-convection heat and mass transfer flow of a CuS04 + H2S04 + H2O solution in a horizontal channel is performed by using an electrochemical system. Unstable temperature and concentration gradients imposed by a heated cathodic bottom initiate an ascending (secondary) flow of light boundary-layer fluid into the freestream. To visualize the flow, the shadowgraph technique is used. Electrical measurements are used to obtain mass transfer rates and to infer a Sherwood number. The ranges of the parameters studied in the present work for the square channel are Pr = 5-7, Sc = 1,700-2,300, Re = 100-1,000, Grm= 1.27 X 106 and Grab = 4.06 × 106-2.4S × 107.  相似文献   

11.
对某大型核反应堆非能动安全壳冷却系统(PCS)中安全壳外部的热环境进行了研究。建立了安全壳外部狭长空间的自然对流换热计算模型,基于Navier-Stokes(N-S)方程进行了求解,同时研究了安全壳出口高度对非能动安全壳冷却系统冷却性能的影响规律。结果表明:在标准大气压下、进口空气温度308.15K时,基准型安全壳按面积加权的出口平均温度为330.33K,引射的冷却空气质量流量为275.85kg/s,冷却空气带走的热量为6160kW;随着安全壳出口高度的增加,安全壳出口质量流量、换热量不断增加,但变化曲线斜率不断降低,最后趋于平缓,同时,衡量冷却空气有效冷却能力的温度效率线性降低,流动损失线性增大,兼顾换热量与流动损失存在一个最优解。  相似文献   

12.
A. Trejo  C. Garcia 《实验传热》2013,26(1):97-112
Transient heat transfer of liquid methane under forced convection in a 1.8 mm × 1.8 mm asymmetrically heated square channel was investigated. This study is aimed at understanding the heat transfer behavior of cryogenic propellant in cooling channels of a regeneratively cooled rocket engine at the start-up condition. To simulate high heat load conditions representative of regeneratively cooled rocket engines, a high heat flux test facility with cryogenic liquid handing capabilities was developed at the Center for Space Exploration Technology Research. The time history of inlet and outlet fluid temperatures and test section channel wall temperatures were measured at high heat flux conditions (from 1.19 to 3.80 MW/m2) and a Reynolds number (Re) range of 1.88 × 105 to 3.45 × 105. The measured wall temperature data point toward possible film boiling within the test section during certain tests, particularly with higher heat fluxes and lower Reynolds number conditions that resulted in higher wall temperatures. The transient average Nusselt numbers (NuL) of the channel obtained from the experimental measurements are lower than those calculated from the Sieder–Tate correlation (NuO); however, the ratio (NuL/NuO) increases with the increase in Reynolds number. The ratio is around 0.25 at the lower end of Re and then increases to 0.7 at the maximum Re studied in the present investigation.  相似文献   

13.
Boiling heat transfer in a refrigerant R 21 flow in a microchannel heat sink is studied. A stainless steel heat sink with a length of 120 mm contains ten microchannels with a size of 640×2050 μm at cross-section with a wall roughness of 10 μm. The local heat-transfer coefficient distribution along the heat sink length is obtained. The ranges of parameters are: mass flow from 68 to 172 kg/m2s, heat fluxes from 16 to 152 kW/m2, and vapor quality from 0 to 1. The maximum values of the heat transfer coefficient are observed at the inlet of microchannels. The heat transfer coefficients decrease substantially along the length of channels under high heat flux conditions and, on the contrary, change insignificantly under low heat flux condition. A comparison with the well-known models of flow boiling heat transfer is performed and the range of applicability is defined.  相似文献   

14.
In this study, the effect of both hexagonal pin fins (HPFs) and cylindrical pin fins (CPFs) into the rectangular channel on heat transfer augmentation, Nusselt number and friction factor were experimentally investigated. In planning of the experiments, different Reynolds number, pin fin array, pin fin geometry and the ratio of the distance between pin fin spacing (s) to the pin fin hydraulic diameter (s/Dh) were chosen as the design parameters. Air was used as the fluid. The Reynolds number, based on the channel hydraulic diameter of the rectangular channel, was varied from 3188 to 19531. In the experiments, the heating plate was made of stainless steel foil. The foil was electrically heated by means of a high current DC power supply to provide a constantly heated flux surface. The heat transfer results were obtained using the infrared thermal imaging technique. The heat transfer results of the hexagonal pin fins (HPFs) and cylindrical pin fins (CPFs) are compared with those of a smooth plate. Best heat transfer performance was obtained with the hexagonal pin fins. The maximum thermal performance factor ((?), was obtained as Re = 3188, staggered array, s/Dh = 0, ? = 2.28.  相似文献   

15.
作为一种新型微通道换热器,印刷电路板式换热器(Printed Circuit Heat Exchanger,PCHE)因比表面积大、耐高压和低温、海上适应性强以及便于模块化等特点,近年来逐渐成为浮式LNG接收站和浮式储存及再气化装置的主低温换热器首选.针对改进后的错列S型翅片,对超临界LNG在翅片通道内的流动传热特性展...  相似文献   

16.
The results of experimental investigation of critical flow of liquid nitrogen in a long adiabatic channel are presented. As the experimental specimen a channel with a length of 1646 mm, and an inner diameter of 4 mm was used. Pressure in the experiments at the inlet to the specimen was changed in the range pin = (3.06–5.39) × 105 Pa, the outlet pressure was pout = (1.26–4.44) × 105 Pa, and the volumetric flow rate was in the range V = (0–0.042) × 10–3 m3/s. The calculation of the coordinate of the cross section, in which one should expect the emergence of a shock wave, has been conducted. The calculation of local values of speed of sound and the velocity of the mixture allowed us to determine the critical value of the volumetric vapor quality in the critical cross section. Quantitative comparison of the conditions of emergence and existence of the critical flow in the long channel in comparison with short channels is carried out. Fundamental differences are shown.  相似文献   

17.
The paper deals with the numerical study of heat and mass transfer in the process of direct evaporation air cooling in the laminar flow of forced convection in a channel between two parallel insulated plates with alternating wet and dry zones along the length. The system of Navier–Stokes equations and equations of energy and steam diffusion are being solved in two-dimensional approximation. At the channel inlet, all thermal gas-dynamic parameters are constant over the cross section, and the channel walls are adiabatic. The studies were carried out with varying number of dry zones (n = 0–16), their relative length (s/l = 0–1) and Reynolds number Re = 50–1000 in the flow of dry air (φ0 = 0) with a constant temperature at the inlet (T 0 = 30 °C). The main attention is paid to optimization analysis of evaporation cell characteristics. It is shown that an increase in the number of alternating steps leads to an increase in the parameters of thermal and humid efficiency. With an increase in Re number and a decrease in the extent of wet areas, the efficiency parameter reduces.  相似文献   

18.
高密度、 小体积和高集成的电子元器件散热困难, 易造成过早失效, 采用微通道换热器可以实现小体积内高热流的散热, 但流动阻力很大. 为了保证传热效果, 降低流动阻力, 本文提出了一种新型的微通道结构并对其流动与传热特性进行了数值模拟. 首先研究了微通道形状和结构, 模拟结果表明: 进出口截面宽高比为0.8 的矩形微通道的换热效果最好; 并在此基础上提出一种康托尔分型凹槽结构, 研究了有无康托尔分形以及不同分形级数对流动与传热性能的影响, 综合对比发现: 第二级康托尔分形模型 N2 既能保证热阻显著降低, 又能相比阵列结构降低压降, 具有明显的换热优势; 最后对这种康托尔分形结构的凹槽形状, 尺寸及不同方向上的分形进行研究, 结果表明梯形凹槽的下上表面长度比b/a 为0.6 、 流动方向分形比fx 为1 .25 和通道高度方向分形比fy 为1 .5 时换热流动性能最佳.  相似文献   

19.
An experimental study of condensation heat transfer characteristics of flow inside horizontal micro-fin tubes is carried out using R410A, R22, and R32 as the test fluids. This study especially focuses on the influence of heat transfer area upon the condensation heat transfer coefficients. The test sections were made of double tubes using the counter-flow type; the refrigerants condensation inside the test tube enabled heat to exchange with cooling water that flows from the annular side. The saturation temperature and pressure of the refrigerants were measured at the inlet and outlet of the test sections to defined state of refrigerants, and the surface temperatures of the tube were measured. A differential pressure transducer directly measured the pressure drops in the test section. The heat transfer coefficients and pressure drops were calculated using the experimental data. The condensation heat transfer coefficient was measured at the saturation temperature of 48°C with mass fluxes of 50–380 kg/(m2s) and heat fluxes of 3–12 kW/m2. The values of experimental heat transfer coefficient results are compared with the predicted values from the existing correlations in the literature, and a new condensation heat transfer coefficient correlation is proposed.  相似文献   

20.
The effect of suppression of turbulence in a downward bubbly flow and its impact on the wall shear stress and heat transfer are discussed. Measurements were carried out for Reynolds numbers Re = 5000–10000, which were calculated from the velocity of the liquid phase and with the gas volumetric flow rate ratio β = 0–0.05. Data on the size of bubbles detaching from the edges of an array of capillaries in a liquid flow are given. The influence of the disperse phase dimensions on the wall shear stress and heat transfer is discussed. It is shown that change in the size of the dispersed phase can lead to both intensification and deterioration of heat transfer as compared with a single-phase flow at constant flow rates of liquid and gas at the channel inlet. The cause of the heat transfer deterioration is “laminarization” of the flow in the near-wall region. An analysis of the spectral power of signals is given.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏