共查询到20条相似文献,搜索用时 15 毫秒
1.
对倾斜角为20°、24°、28°和32°的单头以及32°的双头周向重叠三分螺旋折流板换热器和弓形折流板换热器的传热和压降性能进行了测试,换热器采用公共壳体和可更换管芯结构。采用壳侧轴向雷诺数和轴向欧拉数分别作为反映壳侧流量和阻力系数的无因次参数。试验结果显示在试验范围内周向重叠三分螺旋折流板换热器壳侧换热系数、壳侧压降和综合性能指标都随着倾斜角增大而减小;倾斜角20°方案的性能指标最佳,其平均壳侧努塞尔数和轴向欧拉数与弓形折流板方案的数值之比分别为1.123和0.45;双头螺旋折流板方案的换热系数和压降都大于同样倾斜角的单头螺旋折流板方案,但两者的综合性能较接近。 相似文献
2.
3.
A novel DC plasma torch with multiple cathodes is developed for generating laminar, transitional and turbulent plasma jets. The jet's characteristics, including jet appearance, voltage fluctuation, thermal efficiency, specific enthalpy, and distributions of temperature, pressure, and velocity, are experimentally investigated. The results show that as the gas flow rate increases, the plasma jet transforms first from the laminar state to the transitional state and second to the turbulent state. Compared with the transitional/turbulent jet, the laminar jet possesses not only a better stability and a longer hightemperature zone but also a higher average/core temperature and a higher specific enthalpy at the nozzle's outlet. With the change of jet states from the laminar to the turbulent flow, the core pressure and velocity at the nozzle's outlet increase,while the decaying rates of temperature/pressure/velocity along the jet's axial direction increase sharply. Furthermore, applications of laminar, transitional and turbulent jets for zirconia spray coating are described. The test results indicate that the long laminar jet is favorable for the deposition of a high-quality coating because the powder particles injected into the laminar jet may have better heating and lower kinetic energy. 相似文献
4.
5.
6.
Ultrasound is considered to be an effective active heat transfer enhancement method, which is widely used in various fields. But there is no clear understanding of flow boiling heat transfer characteristics in micro/mini-channels under ultrasonic field since the studies related are limited up to now. In this paper, a novel minichannel heat exchanger with two ultrasonic transducers inside the inlet and outlet plenum respectively is designed to experimentally investigate the impacts of ultrasound on flow boiling heat transfer enhancement in a minichannel heat sink. Flow visualization analyses reveal that ultrasound can promote rapid bubble motion, bubble detachment from heating wall surface and thereby new bubble generation, and decrease the length of confined bubble. Furthermore, the flow boiling experiments are initiated employing working fluid R141b at different ultrasonic parameters (e.g., frequency, power, angle of radiation) and heat flux under three types of ultrasound excitations: no ultrasound (NU), single inlet ultrasound (IU), inlet and outlet ultrasound (IOU). The results indicate that ultrasound has obvious augmentation effects on flow boiling heat transfer even though the intensification effects will be limited with the heat flux increases. The higher ultrasonic power, the lower ultrasonic frequency and the higher ultrasonic radiation angle, the better intensification efficiency. The maximum enhancement ratio of have in the saturated boiling section reaches 1.88 at 50 W, 23 kHz and 45° under the experimental conditions. This study will be beneficial for future applications of ultrasound on flow boiling heat transfer in micro/mini-channels. 相似文献
7.
8.
9.
为探究热泵供水温度对CO2空气源热泵系统性能的影响,保持室外环境温度15.5℃不变,调节热泵供水温度,测试冷却水流量、气冷器出水温度、压缩机排气温度、气冷器CO2进出口温差、压缩机排气压力、压缩机耗功量、系统制热量、气冷器热交换完善度、系统COP的变化情况。结果表明:供水温度由45℃升至85℃,气冷器出水温度、压缩机排气温度、气冷器CO2进出口温差、压缩机排气压力随之增加,冷却水流量随之减小。系统制热量增加了7.3%、气冷器热交换完善度下降了20.0%、系统COP下降了35%、压缩机功耗增加了65.1%。 相似文献
10.
11.
《等离子体物理论文集》2017,57(2):58-66
Plasma jets from conventional non‐transferred arc plasma devices are usually operated in turbulent flows at atmospheric pressure. In this paper, a novel non‐transferred arc plasma device with multiple cathodes is introduced to produce long, laminar plasma jets at atmospheric pressure. A pure helium atmosphere is used to produce a laminar plasma jet with a maximum length of >60 cm. The influence of gas components, arc currents, anode nozzle diameter, and gas flow rate on the jet characteristics is experimentally studied. The results reveal that the length of the plasma jet increases with increasing helium content and arc current but decreases with increasing nozzle diameter. As the gas flow rate increases, the length of the plasma jet initially increases and then decreases. Accordingly, the plasma jet is transformed from a laminar state to a transitional state and finally to a turbulent state. Furthermore, the anode arc root behaviours corresponding to different plasma jet flows are studied. In conclusion, the multiple stationary arc roots that exist on the anode just inside the nozzle entrance are favourable for the generation of a laminar plasma jet in this device. 相似文献
12.
在Ma=3.0的超声速风洞中, 分别对上游边界层为超声速层流和湍流, 压缩角度为25°和28°的压缩拐角流动进行了实验研究. 采用纳米粒子示踪平面激光散射(NPLS)技术获得了流场整体和局部区域的精细结构, 边界层、剪切层、分离激波、回流区和再附激波等典型结构清晰可见, 测量了超声速层流压缩拐角壁面的压力系数. 从时间平均的流场结构中测量出分离激波、再附激波的角度和再附后重新发展的边界层的增长情况, 通过分析时间相关的流场NPLS图像, 可以发现流场结构随时间的演化特性. 实验结果表明: 在25°的压缩角度下, 超声速层流压缩拐角流动发生了典型的分离, 边界层迅速增长失稳转捩, 并引起一道诱导激波, 流场中出现了K-H涡、剪切层和微弱压缩波结构, 而超声速湍流压缩拐角流动没有出现分离, 湍流边界层始终表现为附着状态; 在28° 的压缩角度下, 超声速层流压缩拐角流动进一步分离, 回流区范围明显扩大, 诱导激波、分离激波向上游移动, 再附激波向下游移动, 分离区流动结构复杂, 相比之下, 超声速湍流压缩拐角流动的回流区范围明显较小, 边界层增长缓慢, 流场中没有出现诱导激波、K-H涡和压缩波, 流动分离区域的结构也相对简单, 但分离激波的强度则明显更强.
关键词:
压缩拐角
层流
湍流
流动结构 相似文献
13.
In this study, steady-state laminar forced flow and heat transfer in a horizontal smooth trapezoidal duct having different corner angles were experimentally investigated in the Reynolds number range from 102 to 103. Flow is hydrodynamically fully developed and thermally developing under a uniform surface temperature condition. Based on the present experimental data of laminar flow in the thermal entrance region, new engineering correlations were presented for the heat transfer and friction coefficients for each corner angle. The results have shown that as the Reynolds number increases heat transfer coefficient increases but Darcy friction factor decreases. Also, it is observed that average Nusselt number increases while average Darcy friction factor decreases with increasing corner angle of the duct. 相似文献
14.
15.
16.
17.
18.
Liquid crystal thermography was used in a water-operated concentric tube-in-tube heat exchanger to determine local annular heat transfer coefficients at the inlet region. An annular diameter ratio of 0.54 was considered with the inlet and outlet orientated perpendicularly to the axial flow direction. Both heated and cooled cases were considered at annular Reynolds numbers ranging from 1,000 to 13,800. Wall temperature distributions were directly measured by means of a coating of thermo-chromic liquid crystals. Local heat transfer coefficients at the inlet were higher than those predicted by most correlations, but good agreement was obtained with some literature. 相似文献
19.
The CFD simulation of heat transfer characteristics of a nanofluid in a circular tube fitted with helical twist inserts under constant heat flux has been explained using Fluent version 6.3.26 in laminar flow. Al2O3 nanoparticles in water of 0.5%, 1.0% and 1.5% concentrations and helical twist inserts of twist ratios 2.93, 3.91 and 4.89 has been used for the simulation. All thermophysical properties of nanofluids are temperature dependent. The heat transfer enhancement increases with Reynolds number and decreases with twist ratio with maximum for the twist ratio 2.93. By comparing the heat transfer rates of water and nanofluids, the increase in Nusselt number is 5%–31% for different helical inserts and different volume concentrations. The maximum heat transfer enhancement is 31.29% for helical insert of twist ratio 2.93 and for the volume concentration of 1.5% corresponding to the Reynolds number of 2039. The data obtained by simulation match with the literature value of water with the discrepancy of less than ±10% for plain tube and tube fitted with helical tape inserts for Nusselt number. 相似文献
20.
Identification of bio-aerosol particles may be enhanced by size sorting before applying analytical techniques. In this paper, the use of ultrasonic acoustic radiation pressure to continuously size fractionate particles in a moving air stream is described. Separate particle-laden and clean air streams are introduced into a channel and merged under laminar flow conditions. An ultrasonic transducer, mounted flush to one wall of the channel, excites a standing ultrasonic wave perpendicular to the flow of the combined air stream. Acoustic radiation forces on the particles cause them to move transverse to the flow direction. Since the radiation force is dependent upon the particle size, larger particles move a greater transverse distance as they pass through the standing wave. The outlet flow is then separated into streams, each containing a range of particle sizes. Experiments were performed with air streams containing glass microspheres with a size distribution from 2-22 μm, using a centerline air stream velocity of approximately 20 cm/s. An electrostatic transducer operating at a nominal frequency of 50 kHz was used to drive an ultrasonic standing wave of 150 dB in pressure amplitude. The microsphere size distributions measured at the outlet were compared with the predictions of a theoretical model. Experiments and theory show reasonable correspondence. The theoretical model also indicates an optimal partitioning of the particle-laden and clean air inlet streams. 相似文献