共查询到20条相似文献,搜索用时 15 毫秒
1.
Qiong Wang Zhe Chen Dingwen Chen Shunbin Luo Lingping Xie 《Biomedical chromatography : BMC》2020,34(12):e4960
In this study, a specific and quick ultra-performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) method was fully developed and validated for simultaneous measurement of the rat plasma levels of vortioxetine (VOR), Lu AA34443 (the major metabolite of VOR), fluoxetine and its metabolite norfluoxetine with diazepam as the internal standard (IS). After a simple protein precipitation with acetonitrile for sample preparation, the separation of the analytes were performed on an Acquity UPLC BEH C18 (2.1 × 50 mm, 1.7 μm) column, with acetonitrile and 0.1% formic acid in water as mobile phase by gradient elution. The detection was achieved on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring mode via an electrospray ionization source. Good linearity was observed in the calibration curve for each analyte. The data of precision, accuracy, matrix effect, recovery and stability all conformed to the bioanalytical method validation of acceptance criteria of US Food and Drug Administration recommendations. The newly developed UPLC–MS/MS method allowed simultaneous quantification of VOR, fluoxetine and their metabolites for the first time and was successfully applied to a pharmacokinetic study in rats. 相似文献
2.
Fuyu Guan Cornelius E. Uboh Lawrence R. Soma Mary Robinson George A. Maylin Xiaoqing Li 《Analytical and bioanalytical chemistry》2013,405(14):4707-4717
Dermorphin is a unique opioid peptide that is 30–40 times more potent than morphine. It was misused and went undetected in horse racing until 2011 when intelligence obtained from a few North American race tracks suggested its use. To prevent such misuse, a reliable analytical method became necessary for detection and identification of dermorphin in post-race horse samples. This paper describes the first liquid chromatography–tandem mass spectrometry (LC–MS/MS) method for such a purpose. Equine plasma and urine samples were pre-treated with ethylenediamine tetra-acetic acid and urea prior to solid-phase extraction (SPE) on Oasis MCX cartridges. Resulting eluates were dried under vacuum and analyzed by LC–MS/MS for dermorphin. The matrix effect, SPE efficiency, intra-day and inter-day accuracy and precision, and stability of the analyte were assessed. The limit of detection was 10 pg/mL in plasma and 20 pg/mL in urine, and the limit of confirmation was 20 pg/mL in plasma and 50 pg/mL in urine. Dermorphin in plasma is stable at ambient temperature, but its diastereomer is unstable. With isotopically labeled dermorphin as an internal standard, the quantification range was 20–10,000 pg/mL in plasma and 50–20,000 pg/mL in urine. The intra-day and inter-day accuracy was from 91 % to 100 % for the low, intermediate, and high concentrations. The intra-day and inter-day coefficients of variation were less than 12 %. The method differentiates dermorphin from its diastereomer. This method is very specific for identification of dermorphin in equine plasma and urine, as assessed by BLAST search and targeted SEQUEST search, and by MS/MS spectrum library search. The method has been successfully applied to analysis of samples collected following dermorphin administration to research horses and of official post-race samples. Figure
? 相似文献
3.
Marco Fisichella Luca Morini Cristina Sempio Angelo Groppi 《Analytical and bioanalytical chemistry》2014,406(14):3497-3506
A multi-analyte method for the detection and quantification of 87 psychoactive drugs (antidepressants, antipsychotics, benzodiazepines, and z-drugs) in human hair has been developed and fully validated using the liquid chromatography–tandem mass spectrometry system. Due to the remarkable increase in requests of hair sample tests (such as for driver’s license renewals, child custody, DFA cases, and postmortem toxicology), we focused on the development of a rapid sample preparation. About 20 mg of hair samples, previously washed and cut into snippets, was ultrasonicated with 700 μl of methanol. Samples were then directly analyzed using a 4000 QTRAP (AB SCIEX, Foster City, CA, USA) with an electrospray ionization (ESI) Turbo VTM Ion Source. The validation criteria parameters were satisfactory and in accordance with the international guidelines. All the compounds tested were successfully detected. One important aspect is the LODs in the low picogram per milligram concentration which may suggest a potential use of this method in cases of detection of single drug exposure. However, the LC–MS/MS method has been successfully applied for the analysis of postmortem cases (n?=?9). 相似文献
4.
Schütz K Persike M Carle R Schieber A 《Analytical and bioanalytical chemistry》2006,384(7-8):1511-1517
The anthocyanin pattern of artichoke heads (Cynara scolymus L.) has been investigated by high-performance liquid chromatography–electrospray ionization mass spectrometry. For this purpose a suitable extraction and liquid chromatographic method was developed. Besides the main anthocyanins—cyanidin 3,5-diglucoside, cyanidin 3-glucoside, cyanidin 3,5-malonyldiglucoside, cyanidin 3-(3′′-malonyl)glucoside, and cyanidin 3-(6′′-malonyl)glucoside—several minor compounds were identified. Among these, two peonidin derivatives and one delphinidin derivative were characterized on the basis of their fragmentation patterns. To the best of our knowledge this is the first report on anthocyanins in artichoke heads consisting of aglycones other than those of cyanidin. Quantification of individual compounds was performed by external calibration. Cyanidin 3-(6′′-malonyl)glucoside was found to be the major anthocyanin in all the samples analyzed. Total anthocyanin content ranged from 8.4 to 1,705.4 mg kg−1 dry mass.
相似文献
5.
Viola L. Borova Niki C. Maragou Pablo Gago-Ferrero Constantinos Pistos Νikolaos S. Τhomaidis 《Analytical and bioanalytical chemistry》2014,406(17):4273-4285
The present work describes the development and validation of a highly sensitive analytical method for the simultaneous determination of 68 compounds, including illicit drugs (opiates, opioids, cocaine compounds, amphetamines, and hallucinogens), psychiatric drugs (benzodiazepines, barbiturates, anesthetics, antiepileptics, antipsychotics, antidepressants, and sympathomimetics), and selected human metabolites in influent and effluent wastewater (IWW and EWW) by liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS). The method involves a pre-concentration and cleanup step, carried out by solid-phase extraction (SPE) using the adsorbent Strata-XC, followed by the instrumental analysis performed by LC–MS/MS, using a Kinetex pentafluorophenyl (PFP) reversed-phase fused-core column and electrospray ionization (ESI) in both positive and negative modes. A systematic optimization of mobile phases was performed to cope with the wide range of physicochemical properties of the analytes. The PFP column was also compared with two reversed-phase columns: fused-core C18 and XB-C18 (with a cross-butyl C18 ligand). SPE optimization and critical aspects associated with the trace level determination of the target compounds (e.g., matrix effects) have been also considered and discussed. Fragmentation patterns for all the classes were proposed. The validated method provides absolute recoveries between 75 and 120 % for most compounds in IWW and EWW. Low method limits of detection were achieved (between 0.04 and 10.0 ng/L for 87 % of the compounds), allowing a reliable and accurate quantification of the analytes at trace level. The method was successfully applied to the analysis of these compounds in five wastewater treatment plants in Santorini, a touristic island of the Aegean Sea, Greece. Thirty-two out of 68 compounds were detected in all IWW samples in the range between 0.6 ng/L (for nordiazepam) and 6,822 ng/L (for carbamazepine) and 22 out of 68 in all EWW samples, with values between 0.4 ng/L (for 9-OH risperidone) and 2,200 ng/L (for carbamazepine). The novel methodology described herein maximizes the information on the environmental analysis of these substances and also provides a first profile of 68 drugs in a Greek touristic area. 相似文献
6.
Mohamed A. El Mubarak Charikleia Danika Charlyne Cachon Charalambia Korovila Korina Atsopardi Nikolaos Panagopoulos Marigoula Margarity Konstantinos Poulas Gregory B. Sivolapenko 《Biomedical chromatography : BMC》2020,34(2):e4752
A sensitive analytical method was developed and validated for the quantification of cotinine in mouse plasma after exposure to smoke of 0.5, 1.0, and 1.5 commercially available cigarettes, using liquid chromatography tandem mass spectrometry. The method was validated over a linear concentration range of 0.075–20.0 ng/mL with the R2 value being higher than 0.99. Both the precision (coefficient of variation; %) and accuracy (relative error; %) were within acceptable criteria of <15%. The lower limit of quantification (LLOQ) for cotinine was 0.075 ng/mL with sufficient specificity, accuracy, and precision. Following exposure to 0.5, 1.0, and 1.5 cigarette smoke, it was observed that the AUC and the Cmax increased linearly as the doses increased. The pharmacokinetics of cotinine was found linear for the range of 0.5–1.5 commercial cigarette smoke. The quantification of the concentration of cotinine in mouse plasma after smoke exposure will facilitate future behavioral and toxicological experiments in animals and may prove useful in predicting cotinine levels in humans during smoking. 相似文献
7.
8.
Martínez-Uroz MA Mezcua M Belmonte Valles N Fernández-Alba AR 《Analytical and bioanalytical chemistry》2012,402(3):1365-1372
A gas chromatography–mass spectrometry method in negative chemical ionization mode has been developed incorporating simultaneous
detection using a micro-electron capture detector (μ-ECD) for the determination of pesticides in fruits and vegetables. This
instrument configuration uses a three-way splitter device which divides the effluent from the analytical column between the
two detectors with the split ratio 1:0.1 (MSD/μ-ECD) in each run. The μ-ECD was used for confirmation purposes. Validation
of the method was performed on three matrices: tomato, apple, and orange. The ethyl acetate method was assayed; recovery studies
were performed at 10 and 100 μg/kg. Recoveries between 70% and 120% were achieved and relative standard deviations lower than
20% (n = 5) were obtained for all pesticides and matrices studied. Limits of quantification lower than 10 μg/kg were obtained for
100% of pesticides in all of the matrices. Limits of quantification lower than 2.5 μg/kg were achieved for 77.8% of pesticides
in the tomato and apple matrices, and for 72.2% of pesticides in the orange matrix. The method showed linear response in the
concentration range tested (2.5–500 μg/kg) with correlation coefficients >0.99. Good repeatability and reproducibility results
were obtained in all cases, with relative standard deviations lower than 16.7% and 20%, respectively. Finally, 20 incurred
samples were analyzed using the proposed method. The simultaneous use of the two detectors was satisfactory for the analysis
of these real samples. The total number of pesticides identified was 25. The number of samples which contained at least one
pesticide was 15—this represented 75% of the total number of samples studied. 相似文献
9.
Leendert Vergeynst Herman Van Langenhove Pieter Joos Kristof Demeestere 《Analytica chimica acta》2013
Uniform guidelines for the data processing and validation of qualitative and quantitative multi-residue analysis using full-spectrum high-resolution mass spectrometry are scarce. 相似文献
10.
O. Vendl F. Berthiller C. Crews R. Krska 《Analytical and bioanalytical chemistry》2009,395(5):1347-1354
Cereals and cereal-based food have often been found to be contaminated with the mycotoxins deoxynivalenol (DON) and zearalenone
(ZON), after infection of the grain with the pathogenic fungus Fusarium. Both the pathogen and the infected plants can chemically modify DON and ZON, including acetylation, glucosidation, and sulfation.
Analytical strategies for detection and quantification of DON and ZON are well known and established but often fail to recognize
the respective metabolites, which are, therefore, also referred to as “masked” mycotoxins. However, several masked forms are
also known to be harmful to mammals. Failure to detect these could lead to significant underestimation of the toxic potential
of a particular sample. To monitor the levels of DON and ZON metabolites in cereals and cereal-based food, we have developed
a LC–MS–MS method capable of simultaneous determination of DON, ZON, and eight of their masked metabolites, namely deoxynivalenol-3-glucoside
(D3G), 3-acetyl-deoxynivalenol (3ADON), zearalenone-4-glucoside (Z4G), α-zearalenol (α-ZOL), β-zearalenol (β-ZOL), α-zearalenol-4-glucoside
(α-ZG), β-zearalenol-4-glucoside (β-ZG), and zearalenone-4-sulfate (Z4S). The suitability of several cleanup strategies including
C18-SPE, primary and secondary amines (PSA), MycoSep push-through columns, and immunoaffinity columns was evaluated. The final
method used no sample cleanup and was successfully validated for four cereal-based food matrices, namely cornflour, porridge,
beer, and pasta, showing good recoveries and precision for all analytes. 相似文献
11.
During the past two decades, chiral capillary electrophoresis (CE) emerged as a promising, effective and economic approach for the enantioselective determination of drugs and their metabolites in body fluids, tissues and in vitro preparations. This review discusses the principles and important aspects of CE-based chiral bioassays, provides a survey of the assays developed during the past 10 years and presents an overview of the key achievements encountered in that time period. Applications discussed encompass the pharmacokinetics of drug enantiomers in vivo and in vitro, the elucidation of the stereoselectivity of drug metabolism in vivo and in vitro, and bioanalysis of drug enantiomers of toxicological, forensic and doping interest. Chiral CE was extensively employed for research purposes to investigate the stereoselectivity associated with hydroxylation, dealkylation, carboxylation, sulfoxidation, N-oxidation and ketoreduction of drugs and metabolites. Enantioselective CE played a pivotal role in many biomedical studies, thereby providing new insights into the stereoselective metabolism of drugs in different species which might eventually lead to new strategies for optimization of pharmacotherapy in clinical practice. 相似文献
12.
Xylazine is used in veterinary medicine for sedation, anesthesia, and analgesia. It has also been reported to be misused as a horse doping agent, a drug of abuse, a drug for attempted sexual assault, and as source of accidental or intended poisonings. So far, no data concerning human metabolism have been described. Such data are necessary for the development of toxicological detection methods for monitoring drug abuse, as in most cases the metabolites are the analytical targets. Therefore, the metabolism of xylazine was investigated in rat and human urine after several sample workup procedures. The metabolites were identified using gas chromatography (GC)–mass spectrometry (MS) and liquid chromatography (LC) coupled with linear ion trap high-resolution multistage MS (MS n ). Xylazine was N-dealkylated and S-dealkylated, oxidized, and/or hydroxylated to 12 phase I metabolites. The phenolic metabolites were partly excreted as glucuronides or sulfates. All phase I and phase II metabolites identified in rat urine were also detected in human urine. In rat urine after a low dose as well as in human urine after an overdose, mainly the hydroxy metabolites were detected using the authors’ standard urine screening approaches by GC–MS and LC–MS n . Thus, it should be possible to monitor application of xylazine assuming similar toxicokinetics in humans. Figure
Reconstructed high-resolution mass chromatograms indicating xylazine and its phase I metabolites as well as the mass spectra with structures of xylazine and one of its hydroxy metabolites 相似文献
13.
Séby F Gagean M Garraud H Castetbon A Donard OF 《Analytical and bioanalytical chemistry》2003,377(4):685-694
A European directive was recently adopted limiting the use of hazardous substances such as Pb, Hg, Cd, and Cr(VI) in vehicle manufacturing. From July 2003 a maximum of 2 g Cr(VI) will be authorised per vehicle in corrosion-preventing coatings of key components. As no standardised procedures are available to check if produced vehicles are in agreement with this directive, the objective of this work was to develop analytical procedures for total chromium and Cr(VI) determination in these materials. The first step of this study was to optimise digestion procedures for total chromium determination in plastic and metallic materials by inductively coupled plasma mass spectrometry (ICP–MS). High resolution (HR) ICP–MS was used to examine the influence of polyatomic interferences on the detection of the 52Cr+ and 53Cr+ isotopes. If there was strong interference with m/z 52 for plastic materials, it was possible to use quadrupole ICP–MS for m/z 53 if digestions were performed with HNO3+H2O2. This mixture was also necessary for digestion of chromium from metallic materials. Extraction procedures in alkaline medium (NH4+/NH3 buffer solution at pH 8.9) assisted by sonication were developed for determining Cr(VI) in four different corrosion-preventing coatings by HPLC–ICP–MS. After optimisation and validation with the only solid reference material certified for its Cr(VI) content (BCR 545; welding dusts), the efficiency of this extraction procedure for screw coatings was compared with that described in the EN ISO 3613 standard generally used in routine laboratories. For coatings comprising zinc and aluminium passivated in depth with chromium oxides the extraction procedure developed herein enabled determination of higher Cr(VI) concentrations. This was also observed for the screw covered with a chromium passivant layer on zinc–nickel. For coating comprising a chromium passivant layer on alkaline zinc the standardized extraction procedure was more efficient. In the case of painted metallic plate, because of a reactive matrix towards Cr(VI), its extraction without degradation was difficult to perform. 相似文献
14.
Ala A. Alhusban Alaa M. Hammad Lujain F. Alzaghari Aliaa I. Shallan Khaldoun Shnewer 《Biomedical chromatography : BMC》2023,37(1):e5513
Tobacco smoking is a preventable main cause of fatal diseases. Accurate measurements of the effects it has on neurotransmitters are essential in developing new strategies for smoking cessation. Moreover, measurements of neurotransmitter levels can aid in developing drugs that counteract the effects of smoking. The aim of this study is to develop and validate a fast, simultaneous and sensitive method for measuring the levels of neurotransmitters in rat brain after the exposure of tobacco cigarettes. The selected neurotransmitters include dopamine, GABA, serotonin, glutamine and glutamate. The method is based on high-performance liquid chromatography–tandem mass spectrometry. Chromatographic separation was achieved within 3 min using a Zorbax SB C18 column (3.0 × 100 mm, 1.8 μm particle size). The mobile phase consisted of HPLC-grade water and acetonitrile each containing 0.3% heptafluorobutyric acid and 0.5% formic acid at gradient conditions. The linear range was 0.015–0.07, 825–7,218, 140–520, 63.42–160.75 and 38.25 × 103 to 110.35 × 103 ng/ml for dopamine, GABA, serotonin, glutamine and glutamate, respectively. Inter- and intra-run accuracy were in the range 97.82–103.37% with a precision (CV%) of ≤0.90%. The results revealed that 4 weeks of cigarette exposure significantly increased neurotransmitter levels after exposure to tobacco cigarettes in various brain regions, including the hippocampus and the amygdala. This increase in neurotransmitters levels may in turn activate the nicotine dependence pathway. 相似文献
15.
A new doping control screening method for the analysis of diuretics and stimulants using ultra high pressure liquid chromatography–high resolution Orbitrap mass spectrometry has been developed. The screening was performed in full scan MS with scan-to-scan polarity switching which allowed to detect more than 120 target analytes. Sample preparation was limited to 10-fold dilution of the urine into the internal standard solution followed by injection. Total run time per sample was 10 min. Validation of the method yielded detection limits for diuretics between 25 and 250 ng mL−1 and for stimulants between 5 and 500 ng mL−1. The screening method has been implemented in routine doping control. 相似文献
16.
A method using on-line solid-phase microextraction (SPME) on a carbowax-templated fiber followed by liquid chromatography (LC) with ultraviolet (UV) detection was developed for the determination of triclosan in environmental water samples. Along with triclosan, other selected phenolic compounds, bisphenol A, and acidic pharmaceuticals were studied. Previous SPME/LC or stir-bar sorptive extraction/LC-UV for polar analytes showed lack of sensitivity. In this study, the calculated octanol–water distribution coefficient (log D) values of the target analytes at different pH values were used to estimate polarity of the analytes. The lack of sensitivity observed in earlier studies is identified as a lack of desorption by strong polar–polar interactions between analyte and solid-phase. Calculated log D values were useful to understand or predict the interaction between analyte and solid phase. Under the optimized conditions, the method detection limit of selected analytes by using on-line SPME-LC-UV method ranged from 5 to 33 ng?L?1, except for very polar 3-chlorophenol and 2,4-dichlorophenol which was obscured in wastewater samples by an interfering substance. This level of detection represented a remarkable improvement over the conventional existing methods. The on-line SPME-LC-UV method, which did not require derivatization of analytes, was applied to the determination of TCS including phenolic compounds and acidic pharmaceuticals in tap water and river water and municipal wastewater samples. Figure
Schematic diagram of the On-line solid-phase microextraction 相似文献
17.
18.
Kunjie Li Feng Qin Lijuan Jing Famei Li Xingjie Guo 《Analytical and bioanalytical chemistry》2013,405(8):2619-2634
Trantinterol is a novel β2-adrenoceptor agonist used for the treatment of asthma. The aim of this study is to identify the metabolites of trantinterol using liquid chromatography tandem mass spectrometry (LC-MS/MS), to isolate the main metabolites, and confirm their structures by nuclear magnetic resonance (NMR). Urine, feces, bile, and blood samples of rats were obtained and analyzed. Reference standards of six metabolites were achieved with the combination of chemical synthesis, microbial transformation, and the model systems of rats. Moreover, in order to investigate the phase I metabolism of trantinterol in humans and to study the species differences between rats and humans, incubations with liver microsomes were performed. The biotransformation by a microbial model Cunninghamella blakesleana AS 3.970 was also studied. A total of 18 metabolites were identified in vivo and in vitro together, 13 of which were newly detected. Three phase I metabolites were detected in vivo and in vitro as well as in the microbial model, including the arylhydroxylamine (M1), the tert-butyl hydroxylated trantinterol (M2) and the 1-carbonyltrantinterol (M3). Another important pathway in rats is glutathione conjugation and further catabolism and oxidation to form consecutive derivatives (M4 through M10). Other metabolites include glucuronide, glucoside, and sulfate conjugates. The results of in vitro experiments indicate no species difference exists among rats, humans, and C. blakesleana AS 3.970 on the phase I metabolism of trantinterol. Our study provided the most comprehensive picture for trantinterol in vivo and in vitro metabolism to this day, and may predict its metabolism in humans. 相似文献
19.
Deborah Montenarh Mathias P. Wernet Markus Hopf Hans H. Maurer Peter H. Schmidt Andreas H. Ewald 《Analytical and bioanalytical chemistry》2014,406(24):5939-5953
In the present study, a liquid chromatography–mass spectrometry (LC-MS/MS) multi-analyte approach based on a simple liquid–liquid extraction was developed for fast target screening and quantification of 33 antidepressants in whole blood, plasma, and serum. The method was validated with respect to selectivity, matrix effects, recovery, process efficiency, accuracy and precision, stabilities, and limits. In addition, cross-calibration between the three biosamples was done to assess the impact of the different matrices on the calibration. Whole blood, plasma, and serum (500 μL each) were extracted twice at pH 7.4 and at pH 10 with ether–ethyl acetate (1:1). Separation, detection, and quantification were performed using LC-MS/MS with electrospray ionization in positive mode. For accuracy and precision, full calibration was performed with ranges from subtherapeutic to toxic concentrations. The approach was sensitive and selective for 33 analytes in whole blood and 31 analytes in plasma and serum and accurate and precise for 30 of the 33 tested drugs in whole blood, 31 in plasma, and 28 in serum. Cross-calibration was successful only for 13 analytes in whole blood and 16 analytes in serum calculated over a calibration curve made in plasma, 12 analytes in whole blood and 15 analytes in plasma calculated over a calibration curve made in serum, and 10 analytes in plasma and 15 analytes in serum calculated over a calibration curve made in whole blood. 相似文献
20.
A universal and robust analytical method for the determination of Δ9-tetrahydrocannabinol (THC) and two of its metabolites
Δ9-(11-OH)-tetrahydrocannabinol (11-OH-THC) and 11-nor-Δ9-carboxy-tetrahydrocannabinol (THC-COOH) in human whole blood was
developed and validated for use in forensic toxicology. Protein precipitation, integrated solid phase extraction and on-line
enrichment followed by high-performance liquid chromatography separation and detection with a triple quadrupole mass spectrometer
were combined. The linear ranges used for the three cannabinoids were from 0.5 to 20 ng/mL for THC and 11-OH-THC and from
2.5 to 100 ng/mL for THC-COOH, therefore covering the requirements for forensic use. Correlation coefficients of 0.9980 or
better were achieved for all three analytes. No relevant hydrolysis was observed for THC-COOH glucuronide with this procedure
— in contrast to our previous GC-MS procedure, which obviously lead to an artificial increase of the THC-COOH concentration
due to the hydrolysis of the glucuronide-conjugate occurring at high pH during the phase-transfer catalyzed methylation step. 相似文献