首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Liu S  Tian J  Zhai J  Wang L  Lu W  Sun X 《The Analyst》2011,136(10):2037-2039
In this communication, we demonstrate for the first time that titanium silicalite-1 zeolite microparticles (TSZMs) can effectively catalyze the reduction of H(2)O(2), leading to an enzymeless H(2)O(2) sensor with a linear detection range from 100 μM to 40 mM (r = 0.994) and a detection limit of 0.5 μM at a signal-to-noise ratio of 3.  相似文献   

2.
C Xiong  Z Xiao  M Zhang  L Ling 《The Analyst》2012,137(19):4428-4434
A sensor for H(2)O(2) and H(2)O(2)-related reactant was constructed with oligonucleotides and Ru(bipy)(2)dppx(2+) (bipy = 2,2'-bipyridine, dppx = 7,8-dimethyl-dipyridophenazine), which was performed by converting the H(2)O(2)-induced DNA cleavage into the change of luminescence. The 'DNA light switch' Ru(bipy)(2)dppx(2+) could emit strong luminescence in the presence of dsDNA. DNA cleavage occurred upon addition of H(2)O(2) due to the Fenton reaction, which resulted in the decrease of the luminescence of Ru(bipy)(2)dppx(2+). Therefore, the luminescence intensity depended on the concentration of H(2)O(2) and H(2)O(2)-related reactants, and the detection limits for H(2)O(2), uric acid and cholesterol were 0.20 μM, 0.46 μM and 1.25 μM, respectively. The recovery varied between 94.0% and 105.0% when the assay was applied to the determination of uric acid and cholesterol in biological samples, which demonstrated the good practicability of the assay.  相似文献   

3.
Tang N  Zheng J  Sheng Q  Zhang H  Liu R 《The Analyst》2011,136(4):781-786
A novel H(2)O(2) sensor based on enzymatically induced deposition of electroactive polyaniline (PANI) at a horseradish peroxide (HRP)/aligned single-wall carbon nanotubes (SWCNTs) modified Au electrode is fabricated, and its electrochemical behaviors are investigated. Electrochemical impedance spectroscopy of the sensor confirmed the formation of PANI on SWCNTs through the HRP catalytic reaction. Cyclic voltammograms of PANI/HRP/SWCNTs modified Au electrodes showed a pair of well-defined redox peaks of PANI with reduction peak potentials of 0.211 and oxidation peak potentials of 0.293 V in 0.1 M HOAc-NaOAc (pH 4.3) solution. The oxidation peak current response of PANI is linearly related to H(2)O(2) concentration from 2.5 μM to 50.0 μM with a correlation coefficient of 0.9923 and a sensitivity of 200 μA mM(-1). The detection limit is determined to be 0.9 μM with a signal-to-noise ratio of 3. Thus, the synergistic performance of the enzyme, the highly efficient polymerization of PANI, and the templated deposition of SWCNTs provided an extensive platform for the design of novel electrochemical biosensors.  相似文献   

4.
Wang Z  Liu F  Teng X  Zhao C  Lu C 《The Analyst》2011,136(23):4986-4990
Using a green catalyst of luminol chemiluminescence (CL), Mg-Al-carbonate layered double hydroxides (denoted as Mg-Al-CO(3) LDHs), a novel, sensitive and rapid CL method was developed for the determination of hydrogen peroxide (H(2)O(2)). The corresponding linear regression equation was established in the range of 0.05-10 μM for H(2)O(2). The detection limit (S/N = 3) is 0.02 μM and the relative standard deviation (RSD) for nine repeated measurements of 1.0 μM H(2)O(2) was 2.9%. This proposed method has been successfully applied to detect H(2)O(2) in rainwater samples with good accuracy and precision. The novel methodology is expected to provide a general protocol for the determination of H(2)O(2) as well as for numerous other oxidase-based reactions giving H(2)O(2) as a product (e.g., glucose).  相似文献   

5.
Narang J  Chauhan N  Pundir CS 《The Analyst》2011,136(21):4460-4466
We describe the construction of a polyaniline (PANI), multiwalled carbon nanotubes (MWCNTs) and gold nanoparticles (AuNPs) modified Au electrode for determination of hydrogen peroxide without using peroxidase (HRP). The AuNPs/MWCNT/PANI composite film deposited on Au electrode was characterized by Scanning Electron Microscopy (SEM) and electrochemical methods. Cyclic voltammetric (CV) studies of the electrode at different stages of construction demonstrated that the modified electrode had enhanced electrochemical oxidation of H(2)O(2), which offers a number of attractive features to develop amperometric sensors based on split of H(2)O(2). The amperometric response to H(2)O(2) showed a linear relationship in the range from 3.0 μM to 600.0 μM with a detection limit of 0.3 μM (S/N = 3) and with high sensitivity of 3.3 mA μM(-1). The sensor gave accurate and satisfactory results, when employed for determination of H(2)O(2) in milk and urine.  相似文献   

6.
鲁晓明  刘顺诚  刘育  卜显和  洪少良 《化学学报》1997,55(10):1009-1018
为研究大环化合物对客体分子的选择性, 合成了通式为[NaL(Et2O)]2Na2Mo8O26的三种新型N-对R苯基氮杂15冠5八钼多酸钠超分子配合物(其中L分别为: N-苯基氮杂15冠5、N-对氯苯基氮杂15冠5和N-对甲苯基氮杂15冠5), 进行了元素分析, 红外光谱与核磁共振等结构参数的表征, 对R基为CH3的标题配合物作了X射线四圆衍射测定, 该晶体属单斜晶系, 空间群为P21/a,a=1.4590(4)nm, b=1.3817(3)nm, c=1.7639(5)nm, β=112.67(2)°, V=3.281(1)nm^3, Mr=2021.3, Dc=2.11g/cm^3,μ=2.37mm^-^1, F(000)=2048, R=0.045和Rw=0.057, 与[Na.(DB18C6)(CH3OH)M6O19和[Na(DB24C8)]2M6O19进行比较,结果表明: 大环化合物不仅对客体金属离子有分子识别性, 而且对与之抗衡的多酸阴离子也具有影响。  相似文献   

7.
Iron telluride nanorods (FeTe NRs, length 45 ± 11 nm) prepared from tellurium nanowires (Te NWs, length 785 ± 170) have been used to detect H(2)O(2) and glucose with a limit of detection (LOD) of 55 nM (linear range = 0.1-5 μM) and 0.38 μM (linear range = 1-100 μM) respectively.  相似文献   

8.
Two new mixed-metal sandwich complexes [M(II)2(H2O)2Fe(III)2(P2W15O56)2]14- (abbreviated [M2Fe2P4W30], M(II) = Co(II), Mn(II)) were obtained at pH 3 by addition of M2+ to [Na2(H2O)2Fe(III)2(P2W15O56)2]16- (abbreviated [Na2Fe2P4W30]) without substitution in the alpha-[P2W15O56]12- (abbreviated [P2W15]) units. Their X-ray structures are reported. At lower pH, back conversion to [Na2Fe2P4W30] was followed by 31P NMR, electrochemistry and UV-visible spectroscopy. The preparation and the characterization in solution of the lacunary intermediate [NaCo(II)(H2O)2Fe(III)2(P2W15O56)2]15- (abbreviated [NaCoFe2P4W30]) is also described.  相似文献   

9.
X Yang  J Bai  Y Wang  X Jiang  X He 《The Analyst》2012,137(18):4362-4367
Silver nanowires synthesized through a polyol process using polyvinylpyrrolidone as protection (PVP-AgNWs) were used as a new electrode material for constructing a sensor. Hydrogen peroxide (H(2)O(2)) and glucose were used as analytes to demonstrate the sensor performance of the PVP-AgNWs. It is found that the PVP-AgNWs-modified glassy carbon electrode (PVP-AgNWs/GCE) exhibits remarkable catalytic performance toward H(2)O(2) reduction. This sensor has a fast amperometric response time of less than 2 s and the catalytic current is linear over the concentration of H(2)O(2) ranging from 20 μM to 3.62 mM (R = 0.998) with a detection limit of 2.3 μM estimated on a signal-to-noise ratio of 3. A glucose biosensor was constructed by immobilizing glucose oxidase (GOD) onto the surface of the PVP-AgNWs/GCE. The resultant glucose biosensor can be used for glucose detection in human blood serum with a sensitivity of 15.86 μA mM(-1) cm(-2) and good selectivity and stability.  相似文献   

10.
A fast and robust analytical method for amperometric determination of hydrogen peroxide (H(2)O(2)) based on batch injection analysis (BIA) on an array of gold microelectrodes modified with platinum is proposed. The gold microelectrode array (n=14) was obtained from electronic chips developed for surface mounted device technology (SMD), whose size offers advantages to adapt them in batch cells. The effect of the dispensing rate, volume injected, distance between the platinum microelectrodes and the pipette tip, as well as the volume of solution in the cell on the analytical response were evaluated. The method allows the H(2)O(2) amperometric determination in the concentration range from 0.8 μmolL(-1) to 100 μmolL(-1). The analytical frequency can attain 300 determinations per hour and the detection limit was estimated in 0.34 μmolL(-1) (3σ). The anodic current peaks obtained after a series of 23 successive injections of 50 μL of 25 μmolL(-1) H(2)O(2) showed an RSD<0.9%. To ensure the good selectivity to detect H(2)O(2), its determination was performed in a differential mode, with selective destruction of the H(2)O(2) with catalase in 10 mmolL(-1) phosphate buffer solution. Practical application of the analytical procedure involved H(2)O(2) determination in rainwater of S?o Paulo City. A comparison of the results obtained by the proposed amperometric method with another one which combines flow injection analysis (FIA) with spectrophotometric detection showed good agreement.  相似文献   

11.
In this work, an amine-terminated poly (amidoamine) dendrimer containing Pt nanoparticles (PAMAM/Pt) nanocomposite was synthesized and a novel amperometric H(2)O(2) biosensor based on PAMAM/Pt and MWCNTs was developed. The resulting film of MWCNTs/PAMAM/Pt was characterized by transmission electron microscopy (TEM), linear sweep voltammetry (LSV) and amperometric i-t curve. It demonstrates excellent electrocatalytic responses toward the reduction of H(2)O(2) at -200 mV (vs.SCE) without HRP participation. Immobilized with glutamate oxidase (GlutaOx), an effective glutamate biosensor, was fabricated, and the in vivo detection for glutamate was realized combining with the on-line microdialysis system. The glutamate biosensor showed good linear range from 1.0 μM to 50.0 μM with the detection limit of 0.5 μM (S/N=3). The basal level of glutamate in the striatum of rat was detected continuously with this on-line system and was calculated to be 5.80±0.12 μM (n=3). This method was proved to be sensitive and selective and may be feasible in the further application of physiology and pathology.  相似文献   

12.
Li C  Zhang H  Wu P  Gong Z  Xu G  Cai C 《The Analyst》2011,136(6):1116-1123
A new method developed for the reliable determination of extracellular and intracellular H(2)O(2) is very useful for gaining a full understanding of the role that H(2)O(2) plays in pathology and physiology, and the relationship between H(2)O(2) and environmental stresses and lipid peroxidation. This work developed and validated an electrochemical approach for the determination of extracellular H(2)O(2) released from RAW 264.7 murine macrophage cells. This approach is based on the electrocatalytic reduction of the released H(2)O(2) at the biosensor of HRP-HAP/GC, which was fabricated by depositing the horseradish peroxidase-hydroxyapatite (HRP-HAP) nanohybrids on a glassy carbon (GC, 3 mm in diameter) electrode. The biosensor exhibited a rapid response (less than 2 s), a low detection limit (0.1±0.02 μM), a wide linear range (5 μM to 0.82 mM), as well as good stability and repeatability. In addition, the common interfering species, such as uric acid (UA), ascorbic acid (AA), glucose, and 3,4-dihydroxyphenylacetic acid (DOPAC), etc., did not cause any interference due to the use of a low operating potential (-400 mV, versus SCE). Therefore, this work has demonstrated a simple and effective sensing platform for the detection of extracellular H(2)O(2) released from cells such as RAW 264.7 cells, which has potential utility to bioelectroanalytical chemistry, cellular biology, and pathophysiology.  相似文献   

13.
Incorporation of palladium nanoparticles on the surface of multi-walled carbon nanotubes and modification of glassy carbon electrode with the prepared nano-hybrid material led to the fabrication of a novel electrode. The modified electrode showed attractive electrocatalytic activity and sensitizing effect on luminol-O(2) and luminol-H(2)O(2) electrochemiluminescence (ECL) reactions at neutral media. The sensitized luminol-O(2) and luminol-H(2)O(2) reactions were successfully applied for the ECL determination of dissolved O(2) and glucose, respectively. Under the optimal conditions for luminol-O(2) system, the ECL signal intensity of luminol was linear with the concentration of dissolved oxygen in the range between 0.08 and 0.94 mM (r=0.9996) and for luminol-H(2)O(2) system, the ECL signal intensity of luminol was linear with the concentration of glucose in the range between 0.1 and 1000 μM (r=0.9998). The limits of detection (S/N=3) for dissolved oxygen and glucose were 0.02 mM and 54 nM, respectively. The relative standard deviations (RSD) for repetitive measurements of 0.50 mM oxygen (n=10) and 10 μM glucose (n=30) were 3.5% and 0.3%, respectively. Also, under the optimal conditions for luminol-H(2)O(2) system, the ECL signal intensity of luminol was linear with the concentration of H(2)O(2) in the range between 1 nM and 0.45 mM (r=0.9997). The limit of detection (S/N=3) for H(2)O(2) detection was 0.5 nM and the relative standard deviation for repetitive measurements of 10 μM H(2)O(2) (n=10) was 0.8%.  相似文献   

14.
A new dinuclear copper salicylaldehyde-glycine Schiff-base complex [Cu(2)(Sal-Gly)(2)(H(2)O)(2)] was synthesized and structurally characterized. [Cu(2)(Sal-Gly)(2)(H(2)O)(2)] crystallized in the monoclinic system in the P2(1)/c space group. The molecule is a dinuclear complex, formed by two [Cu(Sal-Gly)(H(2)O)] units. The electropolymerization properties of the copper complex on a glass carbon electrode were studied at different potential ranges. The electropolymerization occurred when the high scan potential reached 1.4 V. The modified electrode exhibited good electrocatalytic oxidation properties to ascorbic acid and showed a sensitivity of 22.9 nA μM(-1) (r(2) = 0.9998) and detection limit of 0.39 μM (S/N = 3) in the amperometric determination of ascorbic acid. The designed determination method can be used to analyze vitamin C tablets.  相似文献   

15.
Qin X  Lu W  Luo Y  Chang G  Asiri AM  Al-Youbi AO  Sun X 《The Analyst》2012,137(4):939-943
The present paper reports on the first preparation of 2,4,6-tris(2-pyridyl)-1,3,5-triazine nanobelts (TPTNBs) by adjusting the pH value of the solution and the subsequent synthesis of Ag nanoparticle (AgNP)-decorated TPTNBs (AgNP-TPTNBs) by mixing an aqueous AgNO(3) solution with preformed TPTNBs without use of any external reducing agent. It is found that the resultant AgNP-TPTNBs exhibit notable catalytic performance for H(2)O(2) reduction. A glucose biosensor was fabricated by immobilizing glucose oxidase (GOD) onto a AgNP-TPTNBs-modified glassy carbon electrode (GCE) for glucose detection. The constructed glucose sensor has a wide linear response range from 3 mM to 20 mM (r: 0.999) with a detection limit of 190 μM. It is further shown that this glucose biosensor can be used for glucose detection in human blood serum.  相似文献   

16.
The dimer alpha-[{K(H2O)2}(Si2W18O66)]15- (1), synthesized by reacting K10A-alpha-[SiW9O34] with two equivalents of H+ in aqueous solution, has been characterized by polarography and 183W NMR spectroscopy. Nine resonance signals have been observed with the tetrabutylammonium salt in dimethylformamide/acetonitrile solution, in agreement with the crystal structure of the anion which consists of two A-alpha-[SiW9O34]10- associated through two W-O-W junctions. This anion derives from the Wells-Dawson structure by breaking four W-O-W junctions. The pocket between the two-half-anions can be filled by several metal cations. Reaction of transition-metal cations with 1 leads to the formation of [{M(H2O)}(mu-H2O)2K(Si2W18O66)]13- (1M) (M = Co, Ni, Cu) and [{M(H2O)}(mu-H2O)2K{M(H2O)4}(Si2W18O66)]11- (1M2) (M = Mn, Co, Ni) complexes. One potassium is always included in the pocket with one or two transition metals. Because of the shift of the potassium cation to one side of the anion, the coordination modes of the two transition metals are different. Crystals of 1, 1M, and 1Co2 potassium salts are triclinic (P-1, Z = 2) and crystals of 1M2 potassium salts are monoclinic (P2(1)/n, Z = 4). The symmetry of 1Mand 1M2 complexes is C1 and they are present in the crystal as racemate inversion pairs.  相似文献   

17.
Hu JY  Lin YP  Liao YC 《Analytical sciences》2012,28(2):135-140
An inkjet printing method is described to fabricate hydrogen peroxide (H(2)O(2)) sensors. Insoluble Prussian blue (PB) nanoparticles were dispersed in aqueous solvent, and were printed on screen printed carbon electrodes with a piezoelectric inkjet printer for H(2)O(2) detection. The electrochemical behavior of the printed sensors was studied by using cyclic voltammetry and chronoamperometry. The printed sensors showed great electrocatalytic activity toward H(2)O(2) and can be used for amperometric detection of H(2)O(2). The calibration curves for H(2)O(2) determination showed a linear range from 0.02 to 0.7 mM with a sensitivity of 164.82 μA M(-1) cm(-2) for the printed PB film. The results showed the feasibility of applying inkjet printing technology on surface modification; the results also provide an alternative way for manufacturing electrochemical sensors.  相似文献   

18.
赖晓芳  施大双 《结构化学》1992,11(6):476-481
标题化合物的晶体属P2_1/m空间群,α=13.821(2),b=15.355(3),c=11.597(2),β=107.50(2)°,V=2347.2~3,M_r=2091.46,Z=2,D_c=2.959 g·cm~(-3),μ(MoK_o)=30.77cm~(-1),F(000)=1992。用4049个独立可观测衍射精修结构,R=0.033。杂多酸阴离子[PMo_(10)V_2O_(40)]~(5-)具有准Keggin结构,12个金属原子呈无序分布,中心原子P与两个齿顶原子M(Mo/V)在对称面上。P—O平均键长1.541(2),M—O键长1.671(2)-2.432(2)。除一个Na—O配位多面体为畸变三方锥外,其余四个Na—O配位体均为六配位。讨论了Na~+离子呈无序分布的晶体结构特征并初步总结[PMo_(10)V_2O_(40)]~(5-)在不同晶相中的构型。  相似文献   

19.
Luo J  Dong M  Lin F  Liu M  Tang H  Li H  Zhang Y  Yao S 《The Analyst》2011,136(21):4500-4506
A three-dimensional network PAMAM-Au nanocomposite (3D-PAMAM-Au NC) was prepared by using the first generation polyamidoamine dendrimer (G1 PAMAM) as the dispersant agent. The resultant 3D-PAMAM-Au NC was successfully used as an immobilization matrix for the construction of a reagentless mediator-free horseradish peroxidase (HRP)-based H(2)O(2) biosensor on a multi-walled carbon nanotubes (MWCNTs) modified glassy carbon electrode. With the advantages of the three-dimensional network, the organic-inorganic hybrid materials dramatically facilitate the direct electron transfer of HRP, and good bioelectrocatalytic activity towards H(2)O(2) was demonstrated. Under optimum conditions, the current response of the enzyme modified electrode at -0.30 V was detected. The current response is linearly correlated to H(2)O(2) concentration within the range of 18.00 μM to 20.80 mM with a correlation coefficient of 0.9992 and a sensitivity of 377.78 μA mM(-1) cm(-2). The detection limit was down to 6.72 μM (S/N = 3). Furthermore, the biosensor exhibits some other excellent characteristics, such as high selectivity, short response time, and long-term stability. The 3D-PAMAM-Au NC has proved to be a promising biosensing platform for the construction of mediator-free biosensors, and may find wide potential applications in biosensors, biocatalysis, bioelectronics and biofuel cells.  相似文献   

20.
The synthesis and characterizations of a family of isomorphous [Mn(III)(2)M(III)(4)L(2)(μ(4)-O)(2)(N(3))(2)(CH(3)O)(2)(CH(3)OH)(4)(NO(3))(2)]·2H(2)O (M = Y(1), Gd(2), Tb(3), Dy(4)) are reported, where H(4)L = N,N'-dihydroxyethyl-N,N'-(2-hydroxy-4,5-dimethylbenzyl)ethylenediamine. They were obtained from the reactions of H(4)L with M(NO(3))(3)·6H(2)O, Mn(ClO(4))(2)·6H(2)O, NaN(3) and NEt(3) in a 1?:?1?:?1?:?2?:?2 molar ratio. The core structure consists of a Mn(2)M(4) unit. The four M(III) ions that are held together by two μ(4)-bridging oxygen atoms form a butterfly M(4) moiety. The M(4) core is further connected to the two five-coordinate trigonal-bipyramidal Mn(III) ions via one μ(4)-O(2-), two alkyloxo and one methoxo triple bridges. Magnetic susceptibility measurements indicate the presence of intramolecular antiferromagnetic interactions in complex 2, and overall intramolecular ferromagnetic interactions in complexes 3 and 4. The alternating current (AC) magnetic susceptibility studies revealed that complexes 3 and 4 showed frequency-dependent out-of-phase signals, which indicates that they exhibit slow relaxation of the magnetization.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号